-- Version 2.15.1.1, modified 2001-05-31 17:28:06-04 ISO3201-OPT-MIB DEFINITIONS ::= BEGIN IMPORTS Counter, Gauge, enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- Codex MIB Group definitions codex OBJECT IDENTIFIER ::= { enterprises 449 } cdxProductSpecific OBJECT IDENTIFIER ::= { codex 2 } cdx6500 OBJECT IDENTIFIER ::= { cdxProductSpecific 1 } cdx6500Configuration OBJECT IDENTIFIER ::= { cdx6500 2 } cdx6500CfgProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 1 } cdx6500PCTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 1 } cdx6500PCTStationProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 3 } cdx6500Statistics OBJECT IDENTIFIER ::= { cdx6500 3 } cdx6500StatProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 1 } cdx6500PSTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 1 } cdx6500PSTStationProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 3 } cdx6500Controls OBJECT IDENTIFIER ::= { cdx6500 4 } -- Textual conventions DisplayString ::= OCTET STRING -- The Datapac 3201 Port Configuration Table -- This table contains Configuration parameters -- related to a 3201 port. cdx6500PPCT3201PortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPCT3201PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the 3201 Port configuration parameters." ::= { cdx6500PCTPortProtocolGroup 28 } cdx6500PPCT3201PortEntry OBJECT-TYPE SYNTAX Cdx6500PPCT3201PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the 3201 Port Configuration Table." INDEX { iso3201PCfgPortNum } ::= { cdx6500PPCT3201PortTable 1 } Cdx6500PPCT3201PortEntry ::= SEQUENCE { iso3201PCfgPortNum INTEGER, iso3201PCfgPortType INTEGER, iso3201PCfgPortSpeed INTEGER, iso3201PCfgNoOfControllers INTEGER, iso3201PCfgResponseTimeout INTEGER, iso3201PCfgInterChrTimeout INTEGER, iso3201PCfgNoOfRetries INTEGER, iso3201PCfgNoOfConsecRetries INTEGER, iso3201PCfgSlowPollWaitCycle INTEGER, iso3201PCfgElectricalInterfaceType INTEGER, iso3201PCfgV24ElectricalInterfaceOption INTEGER, iso3201PCfgHighSpeedElectricalInterfaceOption INTEGER } iso3201PCfgPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the 3201 port." ::= { cdx6500PPCT3201PortEntry 1 } iso3201PCfgPortType OBJECT-TYPE SYNTAX INTEGER { iso3201 (50) } ACCESS read-only STATUS mandatory DESCRIPTION "The Port Type of the port." ::= { cdx6500PPCT3201PortEntry 2 } iso3201PCfgPortSpeed OBJECT-TYPE SYNTAX INTEGER { speed300 (3), speed1200 (4), speed600 (5), speed1800 (8), speed2400 (13), speed4800 (14), speed9600 (15), speed19200 (16), speed7200 (99) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies port speed in bits per second speed300 : 300 bits per second speed600 : 600 bits per second speed1200 : 1200 bits per second speed1800 : 1800 bits per second speed2400 : 2400 bits per second speed4800 : 4800 bits per second speed7200 : 7200 bits per second speed9600 : 9600 bits per second speed19200 : 19200 bits per second ." ::= { cdx6500PPCT3201PortEntry 3} iso3201PCfgNoOfControllers OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of controllers on this line." ::= { cdx6500PPCT3201PortEntry 4 } iso3201PCfgResponseTimeout OBJECT-TYPE SYNTAX INTEGER (5..255) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the amount of time in 1/20th of a second that the PAD waits for a response from a controller. A value of 5 gives a response timeout of 250ms." ::= { cdx6500PPCT3201PortEntry 5 } iso3201PCfgInterChrTimeout OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the maximum amount of time in 1/20 of a second that the PAD waits between two characters when receiving data from the attatched devices before detecting a line problem. A value of 2 gives an intercharacter timeout of 100ms." ::= { cdx6500PPCT3201PortEntry 6 } iso3201PCfgNoOfRetries OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the retry limit for polls/selects sent, NAKs sent/received and ENQs sent/received. In case of polls and selects, the controller is placed in slow poll mode on reaching this limit." ::= { cdx6500PPCT3201PortEntry 7 } iso3201PCfgNoOfConsecRetries OBJECT-TYPE SYNTAX INTEGER (0..5) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of retries that will be made immediately in case of response timeout on Poll, response timeout on Select or NAK response to select. The next controller in the list will be polled/selected only after these many retries are made for the non-responding controller. All consecutive retries will be counted as one retry attempt." ::= { cdx6500PPCT3201PortEntry 8 } iso3201PCfgSlowPollWaitCycle OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of poll cycles to active controllers before a poll is sent to one controller in the slow poll list." ::= { cdx6500PPCT3201PortEntry 9 } iso3201PCfgElectricalInterfaceType OBJECT-TYPE SYNTAX INTEGER { v24 (1), v35 (2), v36 (3), x21 (4), none (5) } ACCESS read-only STATUS mandatory DESCRIPTION "Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled" ::= { cdx6500PPCT3201PortEntry 10 } iso3201PCfgV24ElectricalInterfaceOption OBJECT-TYPE SYNTAX INTEGER { ri (1), tm (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal" ::= { cdx6500PPCT3201PortEntry 11 } iso3201PCfgHighSpeedElectricalInterfaceOption OBJECT-TYPE SYNTAX INTEGER { none (1), xover (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable" ::= { cdx6500PPCT3201PortEntry 12 } -- 3201 Station Configuration Tables -- These tables contain configuration parameters -- for the 3201 station table cdx6500SPCT3201StnTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500SPCT3201StnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the 3201 Station Configuration parameters." ::= { cdx6500PCTStationProtocolGroup 7 } cdx6500SPCT3201StnEntry OBJECT-TYPE SYNTAX Cdx6500SPCT3201StnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the 3201 Station Configuration Table." INDEX { iso3201SCfgPortNum, iso3201SCfgStnNum } ::= { cdx6500SPCT3201StnTable 1 } Cdx6500SPCT3201StnEntry ::= SEQUENCE { iso3201SCfgPortNum INTEGER, iso3201SCfgStnNum INTEGER, iso3201SCfgControllerAddress DisplayString, iso3201SCfgAutocallMnemonic DisplayString, iso3201SCfgAutocallTimeout INTEGER, iso3201SCfgMaxNoAutocallAttempts INTEGER, iso3201SCfgX25Address DisplayString, iso3201SCfgBillingRecords INTEGER } iso3201SCfgPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the 3201 port." ::= { cdx6500SPCT3201StnEntry 1 } iso3201SCfgStnNum OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "Station number of the 3201 station." ::= { cdx6500SPCT3201StnEntry 2 } iso3201SCfgControllerAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the address of this controller The valid addresses are : 0x20, 0x21, 0x22, 0x23, 0x24, 0x25, 0x26, 0x27, 0x28, 0x29, 0x2A, 0x2B, 0x2C, 0x2D, 0x2E, 0x2F, 0x40, 0x41, 0x42, 0x43, 0x44, 0x45, 0x46, 0x47, 0x48, 0x49, 0x4A, 0x4B, 0x4C, 0x4D, 0x4E, 0x4F, 0x60, 0x61, 0x62, 0x63, 0x64, 0x65, 0x66, 0x67, 0x68, 0x69, 0x6A, 0x6B, 0x6C, 0x6D, 0x6E, 0x6F." ::= { cdx6500SPCT3201StnEntry 3 } iso3201SCfgAutocallMnemonic OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the mnemonic used by the PAD to place calls to the Host for this controller. Host initiated calls will be accepted only if this field is blank." ::= { cdx6500SPCT3201StnEntry 4 } iso3201SCfgAutocallTimeout OBJECT-TYPE SYNTAX INTEGER (5..255) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the time interval in seconds between call attempts." ::= { cdx6500SPCT3201StnEntry 5 } iso3201SCfgMaxNoAutocallAttempts OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of times autocall attempts will be made. A value of 0 will allow unlimited attempts." ::= { cdx6500SPCT3201StnEntry 6 } iso3201SCfgX25Address OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the X.25 address inserted in the calling address field of the call packet sent by the PAD to the Host. This address identifies the controller to the Host." ::= { cdx6500SPCT3201StnEntry 7 } iso3201SCfgBillingRecords OBJECT-TYPE SYNTAX INTEGER { billingDisabled (1), billingEnabled (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This controls whether billing(accounting) records will be created for calls on this station billingDisabled : billing is disabled billingEnabled : billing is enabled ." ::= { cdx6500SPCT3201StnEntry 8 } -- 3201 Port Statistics cdx6500PPST3201PStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPST3201PStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains 3201 Port Statistics parameters." ::= { cdx6500PSTPortProtocolGroup 29 } cdx6500PPST3201PStatsEntry OBJECT-TYPE SYNTAX Cdx6500PPST3201PStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the 3201 Port Statistics Table." INDEX { iso3201PStatsPortNum } ::= { cdx6500PPST3201PStatsTable 1 } Cdx6500PPST3201PStatsEntry ::= SEQUENCE { iso3201PStatsPortNum INTEGER, iso3201PStatsPortStatus INTEGER, iso3201PStatsPortType INTEGER, iso3201PStatsPortSpeed INTEGER, iso3201PStatsPortUtilIn INTEGER, iso3201PStatsPortUtilOut INTEGER, iso3201PStatsLineStatus INTEGER, iso3201PStatsTxChrs Counter, iso3201PStatsTxMsgs Counter, iso3201PStatsTxPolls Counter, iso3201PStatsTxSelects Counter, iso3201PStatsTxACKs Counter, iso3201PStatsTxNAKs Counter, iso3201PStatsTxENQs Counter, iso3201PStatsRxChrs Counter, iso3201PStatsRxMsgs Counter, iso3201PStatsRxACKs Counter, iso3201PStatsRxNAKs Counter, iso3201PStatsRxENQs Counter } iso3201PStatsPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "Port Number of the 3201 Port." ::= { cdx6500PPST3201PStatsEntry 1 } iso3201PStatsPortStatus OBJECT-TYPE SYNTAX INTEGER { disabled (1), up (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the operational status of the port up : port is enabled disabled : port is disabled ." ::= { cdx6500PPST3201PStatsEntry 2 } iso3201PStatsPortType OBJECT-TYPE SYNTAX INTEGER { iso3201 (50) } ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the type of access protocol for this port." ::= { cdx6500PPST3201PStatsEntry 3 } iso3201PStatsPortSpeed OBJECT-TYPE SYNTAX INTEGER { speed300 (3), speed1200 (4), speed600 (5), speed1800 (8), speed2400 (13), speed4800 (14), speed9600 (15), speed19200 (16), speed7200 (99) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies port speed in bits per second speed300 : 300 bits per second speed600 : 600 bits per second speed1200 : 1200 bits per second speed1800 : 1800 bits per second speed2400 : 2400 bits per second speed4800 : 4800 bits per second speed7200 : 7200 bits per second speed9600 : 9600 bits per second speed19200 : 19200 bits per second ." ::= { cdx6500PPST3201PStatsEntry 4 } iso3201PStatsPortUtilIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the port utilization for the line to port direction." ::= { cdx6500PPST3201PStatsEntry 5 } iso3201PStatsPortUtilOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the port utilization for the port to line direction." ::= { cdx6500PPST3201PStatsEntry 6 } iso3201PStatsLineStatus OBJECT-TYPE SYNTAX INTEGER { down (1), up (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the line status : up : if one or more controllers are responding to polls down : if no controllers are responding or garbage is being received." ::= { cdx6500PPST3201PStatsEntry 7 } iso3201PStatsTxChrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of characters transmitted." ::= { cdx6500PPST3201PStatsEntry 8 } iso3201PStatsTxMsgs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of data messages transmitted." ::= { cdx6500PPST3201PStatsEntry 9 } iso3201PStatsTxPolls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of polls transmitted." ::= { cdx6500PPST3201PStatsEntry 10 } iso3201PStatsTxSelects OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of selects transmitted." ::= { cdx6500PPST3201PStatsEntry 11 } iso3201PStatsTxACKs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of data messages for which ACKs were transmitted." ::= { cdx6500PPST3201PStatsEntry 12 } iso3201PStatsTxNAKs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of messages for which NAKs were transmitted." ::= { cdx6500PPST3201PStatsEntry 13 } iso3201PStatsTxENQs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of ENQs transmitted." ::= { cdx6500PPST3201PStatsEntry 14 } iso3201PStatsRxChrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of characters received." ::= { cdx6500PPST3201PStatsEntry 15 } iso3201PStatsRxMsgs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of data messages received." ::= { cdx6500PPST3201PStatsEntry 16 } iso3201PStatsRxACKs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of data messages for which ACKs were received." ::= { cdx6500PPST3201PStatsEntry 17 } iso3201PStatsRxNAKs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of messages for which NAKs were received." ::= { cdx6500PPST3201PStatsEntry 18 } iso3201PStatsRxENQs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of ENQs received." ::= { cdx6500PPST3201PStatsEntry 19 } -- These tables contain Statistics parameters -- for the 3201 Station table. cdx6500SPST3201StnTable OBJECT IDENTIFIER ::= { cdx6500PSTStationProtocolGroup 6 } cdx6500SPST3201SStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500SPST3201StnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains 3201 Station statistics parameters." ::= { cdx6500SPST3201StnTable 1 } cdx6500SPST3201StnEntry OBJECT-TYPE SYNTAX Cdx6500SPST3201StnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the 3201 Station statistics table." INDEX { iso3201SStatsPortNum, iso3201SStatsStnNum } ::= { cdx6500SPST3201SStatsTable 1 } Cdx6500SPST3201StnEntry ::= SEQUENCE { iso3201SStatsPortNum INTEGER, iso3201SStatsStnNum INTEGER, iso3201SStatsControllerAddress DisplayString, iso3201SStatsStnState INTEGER, iso3201SStatsCurrentStatus INTEGER, iso3201SStatsNoOfAutocallAttmpts Gauge, iso3201SStatsNxtAutocallAttmpt INTEGER, iso3201SStatsLastClearCauseCode DisplayString, iso3201SStatsLastClearDiagCode DisplayString, iso3201SStatsLastInCalledAddress DisplayString, iso3201SStatsLastInCallingAddress DisplayString, iso3201SStatsLastInCallFacilities DisplayString, iso3201SStatsLastInCallCUD DisplayString, iso3201SStatsLastOutCalledAddress DisplayString, iso3201SStatsLastOutCallingAddress DisplayString, iso3201SStatsLastOutCallFacilities DisplayString, iso3201SStatsLastOutCallCUD DisplayString } iso3201SStatsPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the 3201 port." ::= { cdx6500SPST3201StnEntry 1 } iso3201SStatsStnNum OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "Station number of the 3201 station." ::= { cdx6500SPST3201StnEntry 2 } iso3201SStatsControllerAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the address of this controller The valid addresses are : 0x20, 0x21, 0x22, 0x23, 0x24, 0x25, 0x26, 0x27, 0x28, 0x29, 0x2A, 0x2B, 0x2C, 0x2D, 0x2E, 0x2F, 0x40, 0x41, 0x42, 0x43, 0x44, 0x45, 0x46, 0x47, 0x48, 0x49, 0x4A, 0x4B, 0x4C, 0x4D, 0x4E, 0x4F, 0x60, 0x61, 0x62, 0x63, 0x64, 0x65, 0x66, 0x67, 0x68, 0x69, 0x6A, 0x6B, 0x6C, 0x6D, 0x6E, 0x6F." ::= { cdx6500SPST3201StnEntry 3 } iso3201SStatsStnState OBJECT-TYPE SYNTAX INTEGER { disabled (1), down (2), up (3), suspended (4), blocked (5) } ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the current state of the station up : when responding to polls down : when tries have expired and controller is in slow poll suspended : when polling has been stopped by host blocked : when polling has been stopped because the X.25 channel is blocked disabled : when station is disabled." ::= {cdx6500SPST3201StnEntry 4 } iso3201SStatsCurrentStatus OBJECT-TYPE SYNTAX INTEGER { idle (1), calling (2), connected (3) } ACCESS read-only STATUS mandatory DESCRIPTION "This gives information regarding the calls placed by this station on its host. calling : when it is waiting call accept from the host connected : when the connection to the host has been accepted idle : when connection attempts are not in progress (no data to send to the Host), or autocall attempts have been exhausted or when it is waiting for autocall timeout (to send call request again)." ::= {cdx6500SPST3201StnEntry 5 } iso3201SStatsNoOfAutocallAttmpts OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the number of attempts made to establish connection to the host. This is reset to 0 when a connection is established." ::= { cdx6500SPST3201StnEntry 6 } iso3201SStatsNxtAutocallAttmpt OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the time (in seconds ) after which the station will place autocall to the host." ::= { cdx6500SPST3201StnEntry 7 } iso3201SStatsLastClearCauseCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Last autocall clear cause code." ::= { cdx6500SPST3201StnEntry 8 } iso3201SStatsLastClearDiagCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Last clear diagnostic code." ::= { cdx6500SPST3201StnEntry 9 } iso3201SStatsLastInCalledAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the called address in the last inbound call request packet sent by this station. A value of 'Last Call Information not available' will be returned if the last incoming call packet is not present." ::= { cdx6500SPST3201StnEntry 10 } iso3201SStatsLastInCallingAddress OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the calling address in the last inbound request packet sent by this station. A value of 'Last Call Information not available' will be returned if the last incoming call packet is not present." ::= { cdx6500SPST3201StnEntry 11 } iso3201SStatsLastInCallFacilities OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the facilities in the last inbound request packet sent by this station. A value of 'Last Call Information not available' will be returned if the last incoming call packet is not present." ::= { cdx6500SPST3201StnEntry 12 } iso3201SStatsLastInCallCUD OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the data in the Call User Data field in the last inbound call request packet sent by this station. A value of 'Last Call Information not available' will be returned if the incoming call packet is not present." ::= { cdx6500SPST3201StnEntry 13 } iso3201SStatsLastOutCalledAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the called address in the last outbound call request packet sent by this station. A value of 'Last Call Information not available' will be returned if the last outgoing call packet is not present." ::= { cdx6500SPST3201StnEntry 14 } iso3201SStatsLastOutCallingAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the calling address in the last outbound call request packet sent by this station. A value of 'Last Call Information not available' will be returned if the last outgoing call packet is not present." ::= { cdx6500SPST3201StnEntry 15 } iso3201SStatsLastOutCallFacilities OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the facilities in the last outbound call request packet sent by this station. A value of 'Last Call Information not available' will be returned if the last outgoing call packet is not present." ::= { cdx6500SPST3201StnEntry 16 } iso3201SStatsLastOutCallCUD OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the data in the Call User Data field in the last outbound call request packet sent by this station. A value of 'Last Call Information not available' will be returned if the last call outgoing packet is not present." ::= { cdx6500SPST3201StnEntry 17 } cdx6500SPST3201PktSummTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500SPST3201PktSummEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the Packet Summary statistics parameters." ::= { cdx6500SPST3201StnTable 2 } cdx6500SPST3201PktSummEntry OBJECT-TYPE SYNTAX Cdx6500SPST3201PktSummEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the Packet Summary statistics table." INDEX { iso3201SStatsPktSummPortNum, iso3201SStatsPktSummStnNum } ::= { cdx6500SPST3201PktSummTable 1 } Cdx6500SPST3201PktSummEntry ::= SEQUENCE { iso3201SStatsPktSummPortNum INTEGER, iso3201SStatsPktSummStnNum INTEGER, iso3201SStatsTxData Counter, iso3201SStatsTxCallRequest Counter, iso3201SStatsTxCallAccept Counter, iso3201SStatsTxClearRequest Counter, iso3201SStatsTxClearConfirm Counter, iso3201SStatsTxResetRequest Counter, iso3201SStatsTxResetConfirm Counter, iso3201SStatsTxWindowClosed Gauge, iso3201SStatsRxData Counter, iso3201SStatsRxCallRequest Counter, iso3201SStatsRxCallAccept Counter, iso3201SStatsRxClearRequest Counter, iso3201SStatsRxClearConfirm Counter, iso3201SStatsRxResetRequest Counter, iso3201SStatsRxResetConfirm Counter, iso3201SStatsRxWindowClosed Gauge } iso3201SStatsPktSummPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the physical port number ." ::= { cdx6500SPST3201PktSummEntry 1 } iso3201SStatsPktSummStnNum OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the entry number of this station." ::= { cdx6500SPST3201PktSummEntry 2 } iso3201SStatsTxData OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the count of data packets transmitted." ::= { cdx6500SPST3201PktSummEntry 3 } iso3201SStatsTxCallRequest OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the count of call request packets transmitted." ::= { cdx6500SPST3201PktSummEntry 4 } iso3201SStatsTxCallAccept OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the count of call accept packets transmitted." ::= { cdx6500SPST3201PktSummEntry 5 } iso3201SStatsTxClearRequest OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the count of clear request packets transmitted." ::= { cdx6500SPST3201PktSummEntry 6 } iso3201SStatsTxClearConfirm OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the count of clear confirm packets transmitted." ::= { cdx6500SPST3201PktSummEntry 7 } iso3201SStatsTxResetRequest OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the count of reset request packets transmitted." ::= { cdx6500SPST3201PktSummEntry 8 } iso3201SStatsTxResetConfirm OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the count of reset confirm packets transmitted." ::= { cdx6500SPST3201PktSummEntry 9 } iso3201SStatsTxWindowClosed OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The 'Transmit Window Closed' counts the number of times the 3201 station could not send data to the adjacent channel because of flow control." ::= { cdx6500SPST3201PktSummEntry 10 } iso3201SStatsRxData OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the count of data packets received." ::= { cdx6500SPST3201PktSummEntry 11 } iso3201SStatsRxCallRequest OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the count of call request packets received." ::= { cdx6500SPST3201PktSummEntry 12 } iso3201SStatsRxCallAccept OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the count of call accept packets received." ::= { cdx6500SPST3201PktSummEntry 13 } iso3201SStatsRxClearRequest OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the count of clear request packets received." ::= { cdx6500SPST3201PktSummEntry 14 } iso3201SStatsRxClearConfirm OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the count of clear confirm packets received." ::= { cdx6500SPST3201PktSummEntry 15 } iso3201SStatsRxResetRequest OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the count of reset request packets received." ::= { cdx6500SPST3201PktSummEntry 16 } iso3201SStatsRxResetConfirm OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the count of reset confirm packets received." ::= { cdx6500SPST3201PktSummEntry 17 } iso3201SStatsRxWindowClosed OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The 'Receive Window Closed' is incremented every time the 3201 station removes data out of its queue towards the terminal and the number of messages queued is greater than 15." ::= { cdx6500SPST3201PktSummEntry 18 } cdx6500SPST3201SummTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500SPST3201SummEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the 3201 summary statistics parameters." ::= { cdx6500SPST3201StnTable 3 } cdx6500SPST3201SummEntry OBJECT-TYPE SYNTAX Cdx6500SPST3201SummEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the 3201 Summary statistics table." INDEX { iso3201SStatsSummPortNum, iso3201SStatsSummStnNum } ::= { cdx6500SPST3201SummTable 1 } Cdx6500SPST3201SummEntry ::= SEQUENCE { iso3201SStatsSummPortNum INTEGER, iso3201SStatsSummStnNum INTEGER, iso3201SStatsTxPolls Counter, iso3201SStatsTxSelects Counter, iso3201SStatsTxDataBytes Counter, iso3201SStatsTxDataMsgs Gauge, iso3201SStatsTxDataMsgsPerHour Counter, iso3201SStatsTxAvgMsgLength Counter, iso3201SStatsTxMsgsNAKed Gauge, iso3201SStatsTxSelectRetryExhausted Counter, iso3201SStatsTxNAKRetryExhausted Counter, iso3201SStatsTxENQs Gauge, iso3201SStatsTxENQRetryExhausted Counter, iso3201SStatsTxPollingSuspendedByHost Gauge, iso3201SStatsRxDataBytes Counter, iso3201SStatsRxDataMsgs Gauge, iso3201SStatsRxDataMsgsPerHour Counter, iso3201SStatsRxAvgMsgLength Counter, iso3201SStatsRxMsgsNAKed Gauge, iso3201SStatsRxMsgsAborted Gauge, iso3201SStatsRxSelectsNAKed Gauge, iso3201SStatsRxInvRespToSelect Counter, iso3201SStatsRxNAKRetryExhausted Counter, iso3201SStatsRxENQs Gauge, iso3201SStatsRxENQRetryExhausted Counter, iso3201SStatsRxInterChrTimeout Counter, iso3201SStatsRxPollTimeout Gauge, iso3201SStatsRxSelectTimeout Gauge, iso3201SStatsRxReceiveTimeout Counter, iso3201SStatsRxParityErrorsOnCntrl Gauge } iso3201SStatsSummPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the physical port number." ::= { cdx6500SPST3201SummEntry 1 } iso3201SStatsSummStnNum OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the entry number of this station." ::= { cdx6500SPST3201SummEntry 2 } iso3201SStatsTxPolls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the number of polls transmitted to this controller." ::= { cdx6500SPST3201SummEntry 3 } iso3201SStatsTxSelects OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the number of selects transmitted to this controller." ::= { cdx6500SPST3201SummEntry 4 } iso3201SStatsTxDataBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the number of data bytes transmitted." ::= { cdx6500SPST3201SummEntry 5 } iso3201SStatsTxDataMsgs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of data messages transmitted." ::= { cdx6500SPST3201SummEntry 6 } iso3201SStatsTxDataMsgsPerHour OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of data messages transmitted per hour." ::= { cdx6500SPST3201SummEntry 7 } iso3201SStatsTxAvgMsgLength OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the average length of data messages transmitted." ::= { cdx6500SPST3201SummEntry 8 } iso3201SStatsTxMsgsNAKed OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of data messages for which NAKs were transmitted." ::= { cdx6500SPST3201SummEntry 9 } iso3201SStatsTxSelectRetryExhausted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the number of selects to this controller for which all attempts failed." ::= { cdx6500SPST3201SummEntry 10 } iso3201SStatsTxNAKRetryExhausted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the number of times the NAK sent retry limit was crossed." ::= { cdx6500SPST3201SummEntry 11 } iso3201SStatsTxENQs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of ENQs transmitted." ::= { cdx6500SPST3201SummEntry 12 } iso3201SStatsTxENQRetryExhausted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of times the ENQ sent retry limit was crossed." ::= { cdx6500SPST3201SummEntry 13 } iso3201SStatsTxPollingSuspendedByHost OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of times polling was suspended on account of receiving an interrupt packet from the host." ::= { cdx6500SPST3201SummEntry 14 } iso3201SStatsRxDataBytes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the number of data bytes received." ::= { cdx6500SPST3201SummEntry 15 } iso3201SStatsRxDataMsgs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of data messages received." ::= { cdx6500SPST3201SummEntry 16 } iso3201SStatsRxDataMsgsPerHour OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of data messages received per hour." ::= { cdx6500SPST3201SummEntry 17 } iso3201SStatsRxAvgMsgLength OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the average length of data messages received." ::= { cdx6500SPST3201SummEntry 18 } iso3201SStatsRxMsgsNAKed OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of data messages for which NAKs were received." ::= { cdx6500SPST3201SummEntry 19 } iso3201SStatsRxMsgsAborted OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of data messages to the controller for which were aborted by the controller (by sending EOT)." ::= { cdx6500SPST3201SummEntry 20 } iso3201SStatsRxSelectsNAKed OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of selects for which NAKs were received by the controller." ::= { cdx6500SPST3201SummEntry 21 } iso3201SStatsRxInvRespToSelect OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the number of selects for which an invalid response was received." ::= { cdx6500SPST3201SummEntry 22 } iso3201SStatsRxNAKRetryExhausted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the number of times the NAK received retry limit was crossed." ::= { cdx6500SPST3201SummEntry 23 } iso3201SStatsRxENQs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the number of ENQs received." ::= { cdx6500SPST3201SummEntry 24 } iso3201SStatsRxENQRetryExhausted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the number of times the ENQ received retry limit was crossed." ::= { cdx6500SPST3201SummEntry 25 } iso3201SStatsRxInterChrTimeout OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the number of times intercharacter timeout occurred while receiving data from the controller ." ::= { cdx6500SPST3201SummEntry 26 } iso3201SStatsRxPollTimeout OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of times the controller did not respond to poll before response timeout ." ::= { cdx6500SPST3201SummEntry 27 } iso3201SStatsRxSelectTimeout OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the number of times the controller did not respond to select before response timeout." ::= { cdx6500SPST3201SummEntry 28 } iso3201SStatsRxReceiveTimeout OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the number of times the controller did not respond to a ACK before response timeout and the number of times the inter-character timer expired when receiving response to a NAK." ::= { cdx6500SPST3201SummEntry 29 } iso3201SStatsRxParityErrorsOnCntrl OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of times the PAD detected a parity error on the control characters ACK, DLE, NAK, ENQ, EOT, ETX, SOH, STX." ::= { cdx6500SPST3201SummEntry 30 } -- The 3201 Control Objects cdx6500Cont3201Table OBJECT IDENTIFIER ::= { cdx6500Controls 11 } -- The 3201 Port Control Table cdx6500Cont3201PortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500Cont3201PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the 3201 Port Control parameters." ::= { cdx6500Cont3201Table 1 } cdx6500Cont3201PortEntry OBJECT-TYPE SYNTAX Cdx6500Cont3201PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the 3201 Port control Table." INDEX { iso3201PContPortNum } ::= { cdx6500Cont3201PortTable 1 } Cdx6500Cont3201PortEntry ::= SEQUENCE { iso3201PContPortNum INTEGER, iso3201ContPortBoot INTEGER, iso3201ContPortEnable INTEGER, iso3201ContPortDisable INTEGER, iso3201ContPortResetStats INTEGER } iso3201PContPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS not-accessible STATUS mandatory DESCRIPTION "3201 port number ." ::= { cdx6500Cont3201PortEntry 1 } iso3201ContPortBoot OBJECT-TYPE SYNTAX INTEGER { boot (1), noBoot (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Boots the specified 3201 port. boot : Boot the port noBoot : Do not boot the port." ::= { cdx6500Cont3201PortEntry 2 } iso3201ContPortEnable OBJECT-TYPE SYNTAX INTEGER { enable (1), noEnable (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Enables the specified 3201 Port. enable : Enable the Port noEnable : Do not enable the port." ::= { cdx6500Cont3201PortEntry 3 } iso3201ContPortDisable OBJECT-TYPE SYNTAX INTEGER { disable (1), noDisable (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Disables the specified 3201 Port. disable : Disable Port noDisable : Do not disable Port." ::= { cdx6500Cont3201PortEntry 4 } iso3201ContPortResetStats OBJECT-TYPE SYNTAX INTEGER { reset (1), noreset (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Reset statistics for the specified 3201 Port reset : Reset port statistics noReset : Do not reset port statistics." ::= { cdx6500Cont3201PortEntry 5 } -- The 3201 Station Controls Table -- This table contains the station control parameters for -- 3201 station cdx6500Cont3201StnTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500Cont3201StnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the 3201 Station Control parameters." ::= { cdx6500Cont3201Table 2 } cdx6500Cont3201StnEntry OBJECT-TYPE SYNTAX Cdx6500Cont3201StnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the 3201 Station Control Table." INDEX { iso3201SContPortNum, iso3201ContStnNum } ::= { cdx6500Cont3201StnTable 1 } Cdx6500Cont3201StnEntry ::= SEQUENCE { iso3201SContPortNum INTEGER, iso3201ContStnNum INTEGER, iso3201ContStnBoot INTEGER, iso3201ContStnEnable INTEGER, iso3201ContStnDisable INTEGER, iso3201ContStnResetStats INTEGER } iso3201SContPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS not-accessible STATUS mandatory DESCRIPTION "3201 port number." ::= { cdx6500Cont3201StnEntry 1 } iso3201ContStnNum OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS not-accessible STATUS mandatory DESCRIPTION "3201 station number." ::= { cdx6500Cont3201StnEntry 2 } iso3201ContStnBoot OBJECT-TYPE SYNTAX INTEGER { boot (1), noBoot (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Boots the secified 3201 station. boot : Boot the station noBoot : Do not boot Station." ::= { cdx6500Cont3201StnEntry 3 } iso3201ContStnEnable OBJECT-TYPE SYNTAX INTEGER { enable (1), noEnable (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Enables the specified 3201 station enable : Enable station noEnable : Do not enable station." ::= { cdx6500Cont3201StnEntry 4 } iso3201ContStnDisable OBJECT-TYPE SYNTAX INTEGER { disable (1), noDisable (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Disables the specified 3201 Station disable : Disable Station noDisable : Do not disable Station." ::= { cdx6500Cont3201StnEntry 5 } iso3201ContStnResetStats OBJECT-TYPE SYNTAX INTEGER { reset (1), noReset (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Reset statistics for the specified 3201 station reset : Reset station statistics noReset : Do not reset station statistics." ::= { cdx6500Cont3201StnEntry 6 } END