-- $Header: K:/WanSuite/archives/include/pvcs/ds8200.mib,v 1.7 08 Mar 2000 19:28:58 richardm $ INTERFACES-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB; txport OBJECT IDENTIFIER ::= { enterprises 425} companyinfo OBJECT IDENTIFIER ::= { txport 1 } products OBJECT IDENTIFIER ::= { txport 2 } temporary OBJECT IDENTIFIER ::= { txport 3 } traps OBJECT IDENTIFIER ::= { txport 4 } revision OBJECT IDENTIFIER ::= { txport 5 } pdc OBJECT IDENTIFIER ::= { txport 6 } utilities OBJECT IDENTIFIER ::= { txport 7 } -- Above are pre-existing. That is, created prior to August 1998. -- Following were created after August 1998, and are intended to -- be generic in that they can be used across multiple products -- to define and manage technologies. Each generic group is optional, -- in that a given device need not support all technologies. tinterfaces OBJECT IDENTIFIER ::= { txport 8 } mgmtPorts OBJECT IDENTIFIER ::= { tinterfaces 1 } dbu OBJECT IDENTIFIER ::= { tinterfaces 2 } t1e1 OBJECT IDENTIFIER ::= { tinterfaces 3 } ddsNet OBJECT IDENTIFIER ::= { tinterfaces 4 } serialDte OBJECT IDENTIFIER ::= { tinterfaces 5 } analogDte OBJECT IDENTIFIER ::= { tinterfaces 6 } connection OBJECT IDENTIFIER ::= { tinterfaces 7 } maintenance OBJECT IDENTIFIER ::= { tinterfaces 8 } performance OBJECT IDENTIFIER ::= { tinterfaces 9 } itable OBJECT IDENTIFIER ::= { tinterfaces 10 } traplog OBJECT IDENTIFIER ::= { tinterfaces 11 } unitUtilities OBJECT IDENTIFIER ::= { tinterfaces 12 } -- mgmtPorts section -- this section contains the configuration settings for the management ports mgmtPortsTable OBJECT-TYPE SYNTAX SEQUENCE OF MgmtPortsTableEntry ACCESS not-accessible STATUS optional DESCRIPTION "The Management Ports table." ::= { mgmtPorts 1 } mgmtPortsTableEntry OBJECT-TYPE SYNTAX MgmtPortsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Management Ports table." INDEX { mgmtPortsTableIndex } ::= { mgmtPortsTable 1 } MgmtPortsTableEntry ::= SEQUENCE { mgmtPortsTableIndex INTEGER, mgmtPortsDescription DisplayString, mgmtPortsElementID DisplayString, mgmtPortsMode INTEGER, mgmtPortsDialPrefix DisplayString, mgmtPortsPrimaryDialString DisplayString, mgmtPortsSecondaryDialString DisplayString, mgmtPortsExtInitString DisplayString, mgmtPortsCompressedSlip INTEGER, mgmtPortsInternalModem INTEGER } mgmtPortsTableIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Management Ports table." ::= { mgmtPortsTableEntry 1 } mgmtPortsDescription OBJECT-TYPE SYNTAX DisplayString( SIZE(0..40) ) ACCESS read-only STATUS mandatory DESCRIPTION "Contains a textual description of the port." ::= { mgmtPortsTableEntry 2 } mgmtPortsElementID OBJECT-TYPE SYNTAX DisplayString( SIZE(0..27) ) ACCESS read-write STATUS mandatory DESCRIPTION "This object signifies the name of the device." ::= { mgmtPortsTableEntry 3 } mgmtPortsMode OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), coadial(3), coadirect(4), extAlarmOnOpen(5), extAlarmOnClosed(6), slipdial(7), slipdirect(8) } ACCESS read-write STATUS mandatory DESCRIPTION "This object signifies the method used by the port to report alarms." ::= { mgmtPortsTableEntry 4 } mgmtPortsDialPrefix OBJECT-TYPE SYNTAX DisplayString( SIZE(0..38) ) ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the dial string prefix for a modem connected to the port." ::= { mgmtPortsTableEntry 5 } mgmtPortsPrimaryDialString OBJECT-TYPE SYNTAX DisplayString( SIZE(0..30) ) ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the primary dial string for a modem connected to the port." ::= { mgmtPortsTableEntry 6 } mgmtPortsSecondaryDialString OBJECT-TYPE SYNTAX DisplayString( SIZE(0..30) ) ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the secondary dial string for a modem connected to the port." ::= { mgmtPortsTableEntry 7 } mgmtPortsExtInitString OBJECT-TYPE SYNTAX DisplayString( SIZE(0..38) ) ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the init string for a modem connected to the port." ::= { mgmtPortsTableEntry 8 } mgmtPortsCompressedSlip OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3), auto(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies if SLIP compression is to be used." ::= { mgmtPortsTableEntry 9 } mgmtPortsInternalModem OBJECT-TYPE SYNTAX INTEGER { other(1), notPresent(2), enabled(3), disabled(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object signifies if the internal modem (when present) is enabled." ::= { mgmtPortsTableEntry 10 } -- dbu section -- dial backup options for TxPort devices which have integrated or -- optional dial backup units dbuConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF DbuConfigTableEntry ACCESS not-accessible STATUS optional DESCRIPTION "The Dial Backup Configuration Table." ::= { dbu 1 } dbuConfigTableEntry OBJECT-TYPE SYNTAX DbuConfigTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Dial Backup Configuration table." INDEX { dbuNearIndex, dbuFarIndex, dbuConfigTableIndex } ::= { dbuConfigTable 1 } DbuConfigTableEntry ::= SEQUENCE { dbuNearIndex INTEGER, dbuFarIndex INTEGER, dbuConfigTableIndex INTEGER, dbuDescription DisplayString, dbuRate INTEGER, dbuMode INTEGER, dbuFormat INTEGER, dbuNumber DisplayString, dbuStatus INTEGER, dbuCommand INTEGER, dbuActivator1 INTEGER, dbuActivator2 INTEGER, dbuDialStr DisplayString, dbuInitStr DisplayString, dbuHangupStr DisplayString, dbuPasswordStr DisplayString, dbuSecurity INTEGER, dbuDtrDial INTEGER, dbuISDNSwitchType INTEGER, dbuISDNSwitchVersion INTEGER, dbuISDNTEI INTEGER, dbuISDNSPID DisplayString, dbuISDNDDNUM DisplayString } dbuNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { dbuConfigTableEntry 1 } dbuFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { dbuConfigTableEntry 2 } dbuConfigTableIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Dial Backup table." ::= { dbuConfigTableEntry 3 } dbuDescription OBJECT-TYPE SYNTAX DisplayString( SIZE(0..40) ) ACCESS read-only STATUS mandatory DESCRIPTION "Contains a textual description of the dbu." ::= { dbuConfigTableEntry 4 } dbuRate OBJECT-TYPE SYNTAX INTEGER { dbuRateOther(1), dbuRate2400(2), dbuRate4800(3), dbuRate9600(4), dbuRate19200(5), dbuRate38400(6), dbuRate56000(7), dbuRate57600(8), dbuRate64000(9) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is the identifier of the current DDS DBU rate. The values mean: dbuRate2400 the DBU interface is operating at 2400bps dbuRate4800 the DBU interface is operating at 4800bps dbuRate9600 the DBU interface is operating at 9600bps dbuRate19200 the DBU interface is operating at 19200bps dbuRate38400 the DBU interface is operating at 38400bps dbuRate56000 the DBU interface is operating at 56000bps dbuRate57600 the DBU interface is operating at 57600bps dbuRate64000 the DBU interface is operating at 64000bps" ::= { dbuConfigTableEntry 5 } dbuMode OBJECT-TYPE SYNTAX INTEGER { dbuModeOther(1), dbuModeOrig(2), dbuModeAnsw(3), dbuModeNotAvail(4), dbuModeCallbackOrig(5), dbuModeCallbackAnsw(6), dbuModeMaster(7), dbuModeSlave(8) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is the identifier of the current mode that the Dial Backup Unit is operating in. The values mean: dbuModeOrig The dial backup unit is operating in the originate mode dbuModeAnsw The dial backup unit is operating in the answer mode dbuModeNotAvail The dial backup unit's mode is not available dbuModeCallbackOrig The dial backup unit is operating in the callback originate mode dbuModeCallbackAnsw The dial backup unit is operating in the callback mode dbuModeMaster The dial backup unit is configured as a master unit dbuModeSlave The dial backup unit is configured as a slave unit" ::= { dbuConfigTableEntry 6 } dbuFormat OBJECT-TYPE SYNTAX INTEGER { dbuFormatOther(1), dbuFormatSync(2), dbuFormatAsync(3), dbuFormatNotAvail(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is the identifier of the current format that the Dial Backup Unit is operating in. The values mean: dbuFormatSync The dial backup unit is operating in the synchronous format dbuFormatAsync The dial backup unit is operating in the asynchronous format dbuFormatNotAvail The dial backup unit's format is not available" ::= { dbuConfigTableEntry 7 } dbuNumber OBJECT-TYPE SYNTAX DisplayString( SIZE(0..100) ) ACCESS read-write STATUS mandatory DESCRIPTION "This string is the currently programmed number for the dial backup unit to call" ::= { dbuConfigTableEntry 8 } dbuStatus OBJECT-TYPE SYNTAX INTEGER { dbuStatusOther(1), dbuStatusDisabled(2), dbuStatusEnabled(3), dbuStatusActive(4), dbuStatusLocked(5), dbuStatusConnecting(6), dbuStatusDisallowed(7), dbuStatusAwaitingCall(8), dbuStatusDialing(9), dbuStatusDisconnecting(10), dbuStatusTesting(11), dbuStatusTestPassed(12), dbuStatusTestFailed(13) } ACCESS read-only STATUS mandatory DESCRIPTION "This object is the identifier of the current Dial Backup Unit operating status. The values mean: dbuStatusDisabled The dial backup unit is either not installed or disabled dbuStatusEnabled The dial backup unit is installed and enabled dbuStatusActive The dial backup unit is currently active dbuStatusLocked The dial backup unit is in a locked state dbuStatusConnecting The dial backup unit is in the process of connecting dbuStatusDisallowed The dial backup unit is currently not allowed to activate due to the Time Of Day Enable settings dbuStatusAwaitingCall The dial backup unit is in the process of waiting for an incoming call dbuStatusDialing The dial backup unit is in the process of placing a call dbuStatusDisconnecting The dial backup unit is in the process of disconnecting dbuStatusTesting The dial backup unit is in the process of testing dbuStatusTestPassed The dial backup unit has passed a self-test dbuStatusTestFailed The dial backup unit has failed a self-test" ::= { dbuConfigTableEntry 9 } dbuCommand OBJECT-TYPE SYNTAX INTEGER { dbuCommandOther(1), dbuCommandDisable(2), dbuCommandEnable(3), dbuCommandActivate(4), dbuCommandLock(5), dbuCommandEnableDaily(6), dbuCommandTest(7) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is the identifier of the current setting that the Dial Backup Unit is operating in. The values mean: dbuCommandDisable The dial backup unit is not to operate dbuCommandEnable The dial backup unit is to operate, subject to Activator and line conditions only dbuCommandActivate The dial backup unit is to operate, irregardless of line conditions dbuCommandLock The dial backup unit is to continue operating, irregardless of line conditions dbuCommandEnableDaily The dial backup unit is to operate, subject to Activator, line conditions, and the Time Of Day Enable fields dbuCommandTest The dial backup unit is commanded to test the link." ::= { dbuConfigTableEntry 10 } dbuActivator1 OBJECT-TYPE SYNTAX INTEGER { dbuActivatorOther(1), dbuActivatorLOS(2), dbuActivatorOOS(3), dbuActivatorOOF(4), dbuActivatorAny(5), dbuActivatorES(6), dbuActivatorSES(7), dbuActivatorUAS(8), dbuActivatorLOF(9), dbuActivatorRAS(10), dbuActivatorAIS(11), dbuActivatorBPV(12) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is the identifier of the current trigger that will activate the Dial Backup Unit. The values mean: dbuActivatorLOS The dial backup unit is activated by a LOS alarm condition dbuActivatorOOS The dial backup unit is activated by an OOS alarm condition dbuActivatorOOF The dial backup unit is activated by an OOF alarm condition dbuActivatorAny The dial backup unit is activated by a LOS, OOS, or OOF alarm condition dbuActivatorES The dial backup unit is activated by an ES alarm condition dbuActivatorSES The dial backup unit is activated by an SES alarm condition dbuActivatorUAS The dial backup unit is activated by an UAS alarm condition dbuActivatorLOF The dial backup unit is activated by an LOF alarm condition dbuActivatorRAS The dial backup unit is activated by an RAS alarm condition dbuActivatorAIS The dial backup unit is activated by an AIS alarm condition dbuActivatorBPV The dial backup unit is activated by an BPV alarm condition" ::= { dbuConfigTableEntry 11 } dbuActivator2 OBJECT-TYPE SYNTAX INTEGER { dbuActivatorOther(1), dbuActivatorLOS(2), dbuActivatorOOS(3), dbuActivatorOOF(4), dbuActivatorAny(5), dbuActivatorES(6), dbuActivatorSES(7), dbuActivatorUAS(8), dbuActivatorLOF(9), dbuActivatorRAS(10), dbuActivatorAIS(11), dbuActivatorBPV(12) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is the identifier of the current trigger that will activate the Dial Backup Unit. The values mean: dbuActivatorLOS The dial backup unit is activated by a LOS alarm condition dbuActivatorOOS The dial backup unit is activated by a OOS alarm condition dbuActivatorOOF The dial backup unit is activated by a OOF alarm condition dbuActivatorAny The dial backup unit is activated by a LOS, OOS, or OOF alarm condition dbuActivatorES The dial backup unit is activated by an ES alarm condition dbuActivatorSES The dial backup unit is activated by an SES alarm condition dbuActivatorUAS The dial backup unit is activated by an UAS alarm condition dbuActivatorLOF The dial backup unit is activated by an LOF alarm condition dbuActivatorRAS The dial backup unit is activated by an RAS alarm condition dbuActivatorAIS The dial backup unit is activated by an AIS alarm condition dbuActivatorBPV The dial backup unit is activated by an BPV alarm condition" ::= { dbuConfigTableEntry 12 } dbuDialStr OBJECT-TYPE SYNTAX DisplayString( SIZE(0..50) ) ACCESS read-write STATUS mandatory DESCRIPTION "This string is the dial string sent to the dial backup unit during every connection attempt" ::= { dbuConfigTableEntry 13 } dbuInitStr OBJECT-TYPE SYNTAX DisplayString( SIZE(0..50) ) ACCESS read-write STATUS mandatory DESCRIPTION "This string is the initialization string sent to the dial backup unit before every connection attempt" ::= { dbuConfigTableEntry 14 } dbuHangupStr OBJECT-TYPE SYNTAX DisplayString( SIZE(0..50) ) ACCESS read-write STATUS mandatory DESCRIPTION "This string is the hangup command string sent to the dial backup unit after every successful call" ::= { dbuConfigTableEntry 15 } dbuPasswordStr OBJECT-TYPE SYNTAX DisplayString( SIZE(0..8) ) ACCESS read-write STATUS mandatory DESCRIPTION "This string is the prompt character and password string for the dial backup unit in Callback DBU" ::= { dbuConfigTableEntry 16 } dbuSecurity OBJECT-TYPE SYNTAX INTEGER { dbuSecurityOther(1), dbuSecurityDisable(2), dbuSecurityEnable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables security on dial backup unit." ::= { dbuConfigTableEntry 17 } dbuDtrDial OBJECT-TYPE SYNTAX INTEGER { dbuDtrDialOther(1), dbuDtrDialDisable(2), dbuDtrDialEnable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables DTR dial feature on dial backup unit." ::= { dbuConfigTableEntry 18 } dbuISDNSwitchType OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the switch type for the ISDN DBU." ::= { dbuConfigTableEntry 19 } dbuISDNSwitchVersion OBJECT-TYPE SYNTAX INTEGER { dbuISDNSwitchVersionOther(1), dbuISDNSwitchVersionNational1(2), dbuISDNSwitchVersionATTP2P(3), dbuISDNSwitchVersionATTMP(4), dbuISDNSwitchVersionDMS100PVCIC0(5), dbuISDNSwitchVersionDMS100PVCIC1(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the switch version for the ISDN DBU." ::= { dbuConfigTableEntry 20 } dbuISDNTEI OBJECT-TYPE SYNTAX INTEGER { dbuISDNTEIOther(1), dbuISDNTEIDisable(2), dbuISDNTEIAuto(3), dbuISDNTEI0(4), dbuISDNTEI1(5), dbuISDNTEI2(6), dbuISDNTEI3(7), dbuISDNTEI4(8), dbuISDNTEI5(9), dbuISDNTEI6(10), dbuISDNTEI7(11), dbuISDNTEI8(12), dbuISDNTEI9(13), dbuISDNTEI10(14), dbuISDNTEI11(15), dbuISDNTEI12(16), dbuISDNTEI13(17), dbuISDNTEI14(18), dbuISDNTEI15(19), dbuISDNTEI16(20), dbuISDNTEI17(21), dbuISDNTEI18(22), dbuISDNTEI19(23), dbuISDNTEI20(24), dbuISDNTEI21(25), dbuISDNTEI22(26), dbuISDNTEI23(27), dbuISDNTEI24(28), dbuISDNTEI25(29), dbuISDNTEI26(30), dbuISDNTEI27(31), dbuISDNTEI28(32), dbuISDNTEI29(33), dbuISDNTEI30(34), dbuISDNTEI31(35), dbuISDNTEI32(36), dbuISDNTEI33(37), dbuISDNTEI34(38), dbuISDNTEI35(39), dbuISDNTEI36(40), dbuISDNTEI37(41), dbuISDNTEI38(42), dbuISDNTEI39(43), dbuISDNTEI40(44), dbuISDNTEI41(45), dbuISDNTEI42(46), dbuISDNTEI43(47), dbuISDNTEI44(48), dbuISDNTEI45(49), dbuISDNTEI46(50), dbuISDNTEI47(51), dbuISDNTEI48(52), dbuISDNTEI49(53), dbuISDNTEI50(54), dbuISDNTEI51(55), dbuISDNTEI52(56), dbuISDNTEI53(57), dbuISDNTEI54(58), dbuISDNTEI55(59), dbuISDNTEI56(60), dbuISDNTEI57(61), dbuISDNTEI58(62), dbuISDNTEI59(63), dbuISDNTEI60(64), dbuISDNTEI61(65), dbuISDNTEI62(66), dbuISDNTEI63(67) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the ISDN DBU TEI." ::= { dbuConfigTableEntry 21 } dbuISDNSPID OBJECT-TYPE SYNTAX DisplayString(SIZE(0..20)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the SPID for the ISDN DBU." ::= { dbuConfigTableEntry 22 } dbuISDNDDNUM OBJECT-TYPE SYNTAX DisplayString(SIZE(0..20)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the Data Directory Number for the ISDN DBU." ::= { dbuConfigTableEntry 23 } dbuResetStringsTable OBJECT-TYPE SYNTAX SEQUENCE OF DbuResetStringsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of COLD START reprogramming strings for the dial backup unit." ::= { dbu 2 } dbuResetStringsEntry OBJECT-TYPE SYNTAX DbuResetStringsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the dbuResetStringsTable." INDEX { dbuResetNearIndex, dbuResetFarIndex, dbuResetConfigEntryIndex, dbuResetStringsIndex } ::= { dbuResetStringsTable 1 } DbuResetStringsEntry ::= SEQUENCE { dbuResetNearIndex INTEGER, dbuResetFarIndex INTEGER, dbuResetConfigEntryIndex INTEGER, dbuResetStringsIndex INTEGER, dbuResetString DisplayString } dbuResetNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { dbuResetStringsEntry 1 } dbuResetFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { dbuResetStringsEntry 2 } dbuResetConfigEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Dial Backup table." ::= { dbuResetStringsEntry 3 } dbuResetStringsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into the dbuResetStringsTable." ::= { dbuResetStringsEntry 4 } dbuResetString OBJECT-TYPE SYNTAX DisplayString( SIZE(0..50) ) ACCESS read-write STATUS mandatory DESCRIPTION "This string is one of the dial backup unit's COLD START reprogramming strings" ::= { dbuResetStringsEntry 5 } dbuStartStopTable OBJECT-TYPE SYNTAX SEQUENCE OF DbuStartStopTableEntry ACCESS not-accessible STATUS optional DESCRIPTION "The Dial Backup StartStop Table." ::= { dbu 3 } dbuStartStopTableEntry OBJECT-TYPE SYNTAX DbuStartStopTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Dial Backup Start Stop table." INDEX { dbuStartStopNearIndex, dbuStartStopFarIndex, dbuStartStopConfigEntryIndex, dbuStartStopDayOfWeek } ::= { dbuStartStopTable 1 } DbuStartStopTableEntry ::= SEQUENCE { dbuStartStopNearIndex INTEGER, dbuStartStopFarIndex INTEGER, dbuStartStopConfigEntryIndex INTEGER, dbuStartStopDayOfWeek INTEGER, dbuStart INTEGER, dbuStop INTEGER } dbuStartStopNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { dbuStartStopTableEntry 1 } dbuStartStopFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { dbuStartStopTableEntry 2 } dbuStartStopConfigEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Dial Backup table." ::= { dbuStartStopTableEntry 3 } dbuStartStopDayOfWeek OBJECT-TYPE SYNTAX INTEGER { dbuStartStopSunday(1), dbuStartStopMonday(2), dbuStartStopTuesday(3), dbuStartStopWednesday(4), dbuStartStopThursday(5), dbuStartStopFriday(6), dbuStartStopSaturday(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The index into the Dial Backup Start Stop times table." ::= { dbuStartStopTableEntry 4 } dbuStart OBJECT-TYPE SYNTAX INTEGER { dbuStartHour00(1), dbuStartHour01(2), dbuStartHour02(3), dbuStartHour03(4), dbuStartHour04(5), dbuStartHour05(6), dbuStartHour06(7), dbuStartHour07(8), dbuStartHour08(9), dbuStartHour09(10), dbuStartHour10(11), dbuStartHour11(12), dbuStartHour12(13), dbuStartHour13(14), dbuStartHour14(15), dbuStartHour15(16), dbuStartHour16(17), dbuStartHour17(18), dbuStartHour18(19), dbuStartHour19(20), dbuStartHour20(21), dbuStartHour21(22), dbuStartHour22(23), dbuStartHour23(24) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is the beginning of an allowable window for Dial Backup Activation." ::= { dbuStartStopTableEntry 5 } dbuStop OBJECT-TYPE SYNTAX INTEGER { dbuStopHour00(1), dbuStopHour01(2), dbuStopHour02(3), dbuStopHour03(4), dbuStopHour04(5), dbuStopHour05(6), dbuStopHour06(7), dbuStopHour07(8), dbuStopHour08(9), dbuStopHour09(10), dbuStopHour10(11), dbuStopHour11(12), dbuStopHour12(13), dbuStopHour13(14), dbuStopHour14(15), dbuStopHour15(16), dbuStopHour16(17), dbuStopHour17(18), dbuStopHour18(19), dbuStopHour19(20), dbuStopHour20(21), dbuStopHour21(22), dbuStopHour22(23), dbuStopHour23(24) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is the end of an allowable window for Dial Backup Activation." ::= { dbuStartStopTableEntry 6 } -- t1e1 section, contains T1 and E1 Network and DTE interface table t1e1ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF T1e1ConfigTableEntry ACCESS not-accessible STATUS optional DESCRIPTION "The T1 and E1 Configuration Table." ::= { t1e1 1 } t1e1ConfigTableEntry OBJECT-TYPE SYNTAX T1e1ConfigTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the t1e1Table." INDEX { t1e1ConfigNearIndex, t1e1ConfigFarIndex, t1e1ConfigIndex } ::= { t1e1ConfigTable 1 } T1e1ConfigTableEntry ::= SEQUENCE { t1e1ConfigNearIndex INTEGER, t1e1ConfigFarIndex INTEGER, t1e1ConfigIndex INTEGER, t1e1Description DisplayString, t1e1Mode INTEGER, t1e1FrameType INTEGER, t1e1LineCode INTEGER, t1e1LineBuildOut INTEGER, t1e1Timing INTEGER, t1e1StationInTiming INTEGER, t1e1StationTiming INTEGER, t1e1PRM INTEGER, t1e1ZeroSuppress INTEGER, t1e1NationalBit INTEGER, t1e1KeepAlive INTEGER, t1e1CRC4Mode INTEGER, t1e1DSXLevel INTEGER, t1e1CRC INTEGER, t1e1FDLPassThrough INTEGER, t1e1AudibleAlarm INTEGER } t1e1ConfigNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { t1e1ConfigTableEntry 1 } t1e1ConfigFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { t1e1ConfigTableEntry 2 } t1e1ConfigIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object is the index into the t1e1Table." ::= { t1e1ConfigTableEntry 3 } t1e1Description OBJECT-TYPE SYNTAX DisplayString( SIZE(0..40) ) ACCESS read-only STATUS mandatory DESCRIPTION "Contains a textual description of the port." ::= { t1e1ConfigTableEntry 4 } t1e1Mode OBJECT-TYPE SYNTAX INTEGER { t1e1ModeOther(1), t1e1ModeDTE(2), t1e1ModeNetwork(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object identifies the port as either a Network (long-haul) or DTE (short-haul) port." ::= { t1e1ConfigTableEntry 5 } t1e1FrameType OBJECT-TYPE SYNTAX INTEGER { t1e1FrameTypeOther(1), t1e1FrameTypeESF(2), t1e1FrameTypeD4(3), t1e1FrameTypeCCSCRC(4), t1e1FrameTypeCCS(5), t1e1FrameTypeCAS(6), t1e1FrameTypeCASCRC(7), t1e1FrameTypeUnframed(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the framing for the network side of the DSU/CSU." ::= { t1e1ConfigTableEntry 6 } t1e1LineCode OBJECT-TYPE SYNTAX INTEGER { t1e1LineCodeOther(1), t1e1LineCodeAMI(2), t1e1LineCodeB8ZS(3), t1e1LineCodeHDB3(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the network side line coding." ::= { t1e1ConfigTableEntry 7 } t1e1LineBuildOut OBJECT-TYPE SYNTAX INTEGER { t1e1LineBuildOutOther(1), t1e1LineBuildOut0db(2), t1e1LineBuildOut75db(3), t1e1LineBuildOut15db(4), t1e1LineBuildOut225db(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the line build out for the network interface. The options are: t1e1LineBuildOut0db indicates a line build out of 0db t1e1LineBuildOut75db indicates a line build out of -7.5db t1e1LineBuildOut15db indicates a line build out of -15db t1e1LineBuildOut225db indicates a line build out of -22.5db" ::= { t1e1ConfigTableEntry 8 } t1e1Timing OBJECT-TYPE SYNTAX INTEGER { t1e1TimingOther(1), t1e1TimingInternal(2), t1e1TimingNetwork(3), t1e1TimingT1DTE(4), t1e1TimingStation(5), t1e1TimingStaClock(6), t1e1TimingPort1(7), t1e1TimingPort2(8), t1e1TimingPort3(9), t1e1TimingPort4(10), t1e1TimingPort5(11), t1e1TimingPort6(12), t1e1TimingPort7(13), t1e1TimingPort8(14), t1e1TimingPort9(15), t1e1TimingPort10(16), t1e1TimingPort11(17), t1e1TimingPort12(18), t1e1TimingPort13(19), t1e1TimingPort14(20), t1e1TimingPort15(21), t1e1TimingPort16(22), t1e1TimingPort17(23), t1e1TimingPort18(24), t1e1TimingPort19(25), t1e1TimingPort20(26), t1e1TimingPort21(27), t1e1TimingPort22(28), t1e1TimingPort23(29), t1e1TimingPort24(30), t1e1TimingPort25(31), t1e1TimingPort26(32), t1e1TimingPort27(33), t1e1TimingPort28(34), t1e1TimingPort29(35), t1e1TimingPort30(36), t1e1TimingPort31(37), t1e1TimingPort32(38), t1e1TimingSlot2PortA(39), t1e1TimingSlot2PortB(40), t1e1TimingSlot3PortA(41), t1e1TimingSlot3PortB(42), t1e1TimingSlot4PortA(43), t1e1TimingSlot4PortB(44), t1e1TimingSlot5PortA(45), t1e1TimingSlot5PortB(46), t1e1TimingSlot6PortA(47), t1e1TimingSlot6PortB(48), t1e1TimingSlot2Dsu1PortA(49), t1e1TimingSlot2Dsu1PortB(50), t1e1TimingSlot2Dsu2PortA(51), t1e1TimingSlot2Dsu2PortB(52), t1e1TimingSlot2Dsu3PortA(53), t1e1TimingSlot2Dsu3PortB(54), t1e1TimingSlot2Dsu4PortA(55), t1e1TimingSlot2Dsu4PortB(56), t1e1TimingSlot2Dsu5PortA(57), t1e1TimingSlot2Dsu5PortB(58), t1e1TimingSlot2Dsu6PortA(59), t1e1TimingSlot2Dsu6PortB(60), t1e1TimingSlot3Dsu1PortA(61), t1e1TimingSlot3Dsu1PortB(62), t1e1TimingSlot3Dsu2PortA(63), t1e1TimingSlot3Dsu2PortB(64), t1e1TimingSlot3Dsu3PortA(65), t1e1TimingSlot3Dsu3PortB(66), t1e1TimingSlot3Dsu4PortA(67), t1e1TimingSlot3Dsu4PortB(68), t1e1TimingSlot3Dsu5PortA(69), t1e1TimingSlot3Dsu5PortB(70), t1e1TimingSlot3Dsu6PortA(71), t1e1TimingSlot3Dsu6PortB(72), t1e1TimingSlot4Dsu1PortA(73), t1e1TimingSlot4Dsu1PortB(74), t1e1TimingSlot4Dsu2PortA(75), t1e1TimingSlot4Dsu2PortB(76), t1e1TimingSlot4Dsu3PortA(77), t1e1TimingSlot4Dsu3PortB(78), t1e1TimingSlot4Dsu4PortA(79), t1e1TimingSlot4Dsu4PortB(80), t1e1TimingSlot4Dsu5PortA(81), t1e1TimingSlot4Dsu5PortB(82), t1e1TimingSlot4Dsu6PortA(83), t1e1TimingSlot4Dsu6PortB(84), t1e1TimingSlot5Dsu1PortA(85), t1e1TimingSlot5Dsu1PortB(86), t1e1TimingSlot5Dsu2PortA(87), t1e1TimingSlot5Dsu2PortB(88), t1e1TimingSlot5Dsu3PortA(89), t1e1TimingSlot5Dsu3PortB(90), t1e1TimingSlot5Dsu4PortA(91), t1e1TimingSlot5Dsu4PortB(92), t1e1TimingSlot5Dsu5PortA(93), t1e1TimingSlot5Dsu5PortB(94), t1e1TimingSlot5Dsu6PortA(95), t1e1TimingSlot5Dsu6PortB(96), t1e1TimingSlot6Dsu1PortA(97), t1e1TimingSlot6Dsu1PortB(98), t1e1TimingSlot6Dsu2PortA(99), t1e1TimingSlot6Dsu2PortB(100), t1e1TimingSlot6Dsu3PortA(101), t1e1TimingSlot6Dsu3PortB(102), t1e1TimingSlot6Dsu4PortA(103), t1e1TimingSlot6Dsu4PortB(104), t1e1TimingSlot6Dsu5PortA(105), t1e1TimingSlot6Dsu5PortB(106), t1e1TimingSlot6Dsu6PortA(107), t1e1TimingSlot6Dsu6PortB(108) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the timing source to synchronize the unit's internal timing generators." ::= { t1e1ConfigTableEntry 9 } t1e1StationInTiming OBJECT-TYPE SYNTAX INTEGER { t1e1StationInTimingOther(1), t1e1StationInTimingNX56(2), t1e1StationInTimingNX64(3), t1e1StationInTiming1544(4), t1e1StationInTiming2048(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the input timing if t1e1Timing is set to Station." ::= { t1e1ConfigTableEntry 10 } t1e1StationTiming OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Selects the N-multiple when Station Input Timing is set to either NX56 or NX65. The N range is 1..24" ::= { t1e1ConfigTableEntry 11 } t1e1PRM OBJECT-TYPE SYNTAX INTEGER { t1e1PRMOther(1), t1e1PRMDisable(2), t1e1PRMEnable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables the ANSI T1.403 Performance Report Message functions." ::= { t1e1ConfigTableEntry 12 } t1e1ZeroSuppress OBJECT-TYPE SYNTAX INTEGER { t1e1ZeroOther(1), t1e1ZeroDisable(2), t1e1ZeroEnable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines whether ones density insertion is activated after 15 zeros . To ensure compliance with TR54016, this field must be enabled." ::= { t1e1ConfigTableEntry 13 } t1e1NationalBit OBJECT-TYPE SYNTAX INTEGER { t1e1NationalOther(1), t1e1NationalNone(2), t1e1NationalSA4(3), t1e1NationalSA5(4), t1e1NationalSA6(5), t1e1NationalSA7(6), t1e1NationalSA8(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects a national bit to create a 4-kpbs datalink between the endpoint units." ::= { t1e1ConfigTableEntry 14 } t1e1KeepAlive OBJECT-TYPE SYNTAX INTEGER { t1e1KeepAliveOther(1), t1e1KeepAliveUnframedOnes(2), t1e1KeepAliveFramedOnes(3), t1e1KeepAliveLoop(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects keep alive framed and unframed ones when the unit detects LOS or OOF." ::= { t1e1ConfigTableEntry 15 } t1e1CRC4Mode OBJECT-TYPE SYNTAX INTEGER { t1e1CRC4Other(1), t1e1CRC4Disabled(2), t1e1CRC4Enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects whether CRC4 is enabled or disabled." ::= { t1e1ConfigTableEntry 16 } t1e1DSXLevel OBJECT-TYPE SYNTAX INTEGER { t1e1DSXOther(1), t1e1DSX0110(2), t1e1DSX111220(3), t1e1DSX221330(4), t1e1DSX331440(5), t1e1DSX441550(6), t1e1DSX551660(7), t1e1DSX661up(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the DSX1 interface output level." ::= { t1e1ConfigTableEntry 17 } t1e1CRC OBJECT-TYPE SYNTAX INTEGER { t1e1CRCOther(1), t1e1CRCPass(2), t1e1CRCRegenerate(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines whether received CRC data is passed through or regenerated." ::= { t1e1ConfigTableEntry 18 } t1e1FDLPassThrough OBJECT-TYPE SYNTAX INTEGER { t1e1FDLPassThroughOther(1), t1e1FDLPassThroughPass(2), t1e1FDLPassThroughTerminate(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines whether the ESF FDL passes through the CSU or terminates." ::= { t1e1ConfigTableEntry 19 } t1e1AudibleAlarm OBJECT-TYPE SYNTAX INTEGER { t1e1AudibleAlarmOther(1), t1e1AudibleAlarmDisabled(2), t1e1AudibleAlarmEnabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "If applicable, Enables or Disables the CSU's internal buzzer which alerts users of an alarm condition." ::= { t1e1ConfigTableEntry 20 } t1e1AlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF T1e1AlarmTableEntry ACCESS not-accessible STATUS optional DESCRIPTION "The T1 and E1 Alarm Table." ::= { t1e1 2 } t1e1AlarmTableEntry OBJECT-TYPE SYNTAX T1e1AlarmTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the t1e1Table." INDEX { t1e1AlarmNearIndex, t1e1AlarmFarIndex, t1e1AlarmIndex } ::= { t1e1AlarmTable 1 } T1e1AlarmTableEntry ::= SEQUENCE { t1e1AlarmNearIndex INTEGER, t1e1AlarmFarIndex INTEGER, t1e1AlarmIndex INTEGER, t1e1StatusSummary DisplayString, t1e1AlarmSummary DisplayString, t1e1ESStatus INTEGER, t1e1ESCount INTEGER, t1e1ESThreshold INTEGER, t1e1ESAlarm INTEGER, t1e1SESStatus INTEGER, t1e1SESCount INTEGER, t1e1SESThreshold INTEGER, t1e1SESAlarm INTEGER, t1e1LOSSStatus INTEGER, t1e1LOSSCount INTEGER, t1e1LOSSThreshold INTEGER, t1e1LOSSAlarm INTEGER, t1e1UASStatus INTEGER, t1e1UASCount INTEGER, t1e1UASThreshold INTEGER, t1e1UASAlarm INTEGER, t1e1CSSStatus INTEGER, t1e1CSSCount INTEGER, t1e1CSSThreshold INTEGER, t1e1CSSAlarm INTEGER, t1e1BPVSStatus INTEGER, t1e1BPVSCount INTEGER, t1e1BPVSThreshold INTEGER, t1e1BPVSAlarm INTEGER, t1e1OOFSStatus INTEGER, t1e1OOFSCount INTEGER, t1e1OOFSThreshold INTEGER, t1e1OOFSAlarm INTEGER, t1e1AISStatus INTEGER, t1e1AISCount INTEGER, t1e1AISThreshold INTEGER, t1e1AISAlarm INTEGER, t1e1RASStatus INTEGER, t1e1RASCount INTEGER, t1e1RASThreshold INTEGER, t1e1RASAlarm INTEGER, t1e1AlarmResetTimer INTEGER, t1e1AlarmReset INTEGER } t1e1AlarmNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { t1e1AlarmTableEntry 1 } t1e1AlarmFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { t1e1AlarmTableEntry 2 } t1e1AlarmIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object is the index into the t1e1Table." ::= { t1e1AlarmTableEntry 3 } t1e1StatusSummary OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides a summary of the port status." ::= { t1e1AlarmTableEntry 4 } t1e1AlarmSummary OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides a summary of the port alarms." ::= { t1e1AlarmTableEntry 5 } t1e1ESStatus OBJECT-TYPE SYNTAX INTEGER { t1e1StatusOther(1), t1e1StatusNoES(2), t1e1StatusES(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports if a Errorred Seconds condition exists." ::= { t1e1AlarmTableEntry 6 } t1e1ESCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This count contains the number of consecutive seconds an Errored Seconds condition has existed." ::= { t1e1AlarmTableEntry 7 } t1e1ESThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sets the Errored Seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900." ::= { t1e1AlarmTableEntry 8 } t1e1ESAlarm OBJECT-TYPE SYNTAX INTEGER { t1e1ESAlarmOther(1), t1e1ESAlarmNone(2), t1e1ESAlarmThresholdExceeded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This status indicates if the Errors Seconds threshold is exceeded." ::= { t1e1AlarmTableEntry 9 } t1e1SESStatus OBJECT-TYPE SYNTAX INTEGER { t1e1StatusOther(1), t1e1StatusNoSES(2), t1e1StatusSES(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports if a Severely Errorred condition exists." ::= { t1e1AlarmTableEntry 10 } t1e1SESCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This count contains the number of consecutive seconds a Severely Errored condition has existed." ::= { t1e1AlarmTableEntry 11 } t1e1SESThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sets the Severely Errored seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900." ::= { t1e1AlarmTableEntry 12 } t1e1SESAlarm OBJECT-TYPE SYNTAX INTEGER { t1e1SESAlarmOther(1), t1e1SESAlarmNone(2), t1e1SESAlarmThresholdExceeded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This status indicates if the Severely Errors Seconds threshold is exceeded." ::= { t1e1AlarmTableEntry 13 } t1e1LOSSStatus OBJECT-TYPE SYNTAX INTEGER { t1e1StatusOther(1), t1e1StatusNoLOSS(2), t1e1StatusLOSS(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports if a Loss of Signal condition exists." ::= { t1e1AlarmTableEntry 14 } t1e1LOSSCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This count contains the number of consecutive seconds a Loss of Signal condition has existed." ::= { t1e1AlarmTableEntry 15 } t1e1LOSSThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sets the Loss of Signal seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900." ::= { t1e1AlarmTableEntry 16 } t1e1LOSSAlarm OBJECT-TYPE SYNTAX INTEGER { t1e1LOSSAlarmOther(1), t1e1LOSSAlarmNone(2), t1e1LOSSAlarmThresholdExceeded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This status indicates if the Loss of Signal Seconds threshold is exceeded." ::= { t1e1AlarmTableEntry 17 } t1e1UASStatus OBJECT-TYPE SYNTAX INTEGER { t1e1StatusOther(1), t1e1StatusNoUAS(2), t1e1StatusUAS(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports if an Unavailable condition exists." ::= { t1e1AlarmTableEntry 18 } t1e1UASCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This count contains the number of consecutive seconds an Unavailable condition has existed." ::= { t1e1AlarmTableEntry 19 } t1e1UASThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sets the unavailable seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900." ::= { t1e1AlarmTableEntry 20 } t1e1UASAlarm OBJECT-TYPE SYNTAX INTEGER { t1e1UASAlarmOther(1), t1e1UASAlarmNone(2), t1e1UASAlarmThresholdExceeded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This status indicates if the Unavailable Seconds threshold is exceeded." ::= { t1e1AlarmTableEntry 21 } t1e1CSSStatus OBJECT-TYPE SYNTAX INTEGER { t1e1StatusOther(1), t1e1StatusNoCSS(2), t1e1StatusCSS(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports if a Controlled Slip condition exists." ::= { t1e1AlarmTableEntry 22 } t1e1CSSCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This count contains the number of consecutive seconds in which at least one Controlled Slip occurred." ::= { t1e1AlarmTableEntry 23 } t1e1CSSThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sets the Controlled Slip seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900." ::= { t1e1AlarmTableEntry 24 } t1e1CSSAlarm OBJECT-TYPE SYNTAX INTEGER { t1e1CSSAlarmOther(1), t1e1CSSAlarmNone(2), t1e1CSSAlarmThresholdExceeded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This status indicates if the Controlled Slip seconds threshold is exceeded." ::= { t1e1AlarmTableEntry 25 } t1e1BPVSStatus OBJECT-TYPE SYNTAX INTEGER { t1e1StatusOther(1), t1e1StatusNoBPVS(2), t1e1StatusBPVS(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports if a Bipolar Violation Error condition exists." ::= { t1e1AlarmTableEntry 26 } t1e1BPVSCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This count contains the number of consecutive seconds a Bipolar Violation Error condition has existed." ::= { t1e1AlarmTableEntry 27 } t1e1BPVSThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sets the Bipolar Violation Error seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900." ::= { t1e1AlarmTableEntry 28 } t1e1BPVSAlarm OBJECT-TYPE SYNTAX INTEGER { t1e1BPVSAlarmOther(1), t1e1BPVSAlarmNone(2), t1e1BPVSAlarmThresholdExceeded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This status indicates if the Bipolar Violation Error seconds threshold is exceeded." ::= { t1e1AlarmTableEntry 29 } t1e1OOFSStatus OBJECT-TYPE SYNTAX INTEGER { t1e1StatusOther(1), t1e1StatusNoOOF(2), t1e1StatusOOF(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates that the unit is unable to synchronize on the incoming framing pattern." ::= { t1e1AlarmTableEntry 30 } t1e1OOFSCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This count contains the number of consecutive seconds an OOF condition has existed." ::= { t1e1AlarmTableEntry 31 } t1e1OOFSThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sets the OOF seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900." ::= { t1e1AlarmTableEntry 32 } t1e1OOFSAlarm OBJECT-TYPE SYNTAX INTEGER { t1e1OOFSAlarmOther(1), t1e1OOFSAlarmNone(2), t1e1OOFSAlarmExists(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if an OOF seconds alarm condition exists." ::= { t1e1AlarmTableEntry 33 } t1e1AISStatus OBJECT-TYPE SYNTAX INTEGER { t1e1StatusOther(1), t1e1StatusNoAIS(2), t1e1StatusAIS(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates that the unit is receiving an unframed all ones pattern." ::= { t1e1AlarmTableEntry 34 } t1e1AISCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This count contains the number of consecutive seconds an Unframed All Ones condition has existed." ::= { t1e1AlarmTableEntry 35 } t1e1AISThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sets the AIS seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900." ::= { t1e1AlarmTableEntry 36 } t1e1AISAlarm OBJECT-TYPE SYNTAX INTEGER { t1e1AISAlarmOther(1), t1e1AISAlarmNone(2), t1e1AISAlarmExists(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if an Unframed All Ones alarm condition exists." ::= { t1e1AlarmTableEntry 37 } t1e1RASStatus OBJECT-TYPE SYNTAX INTEGER { t1e1RASStatusOther(1), t1e1RASStatusNoRAS(2), t1e1RASStatusRAS(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports if a Remote (Yellow) Alarm condition exists." ::= { t1e1AlarmTableEntry 38 } t1e1RASCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This count contains the number of consecutive seconds a Remote (Yellow) Alarm condition has existed." ::= { t1e1AlarmTableEntry 39 } t1e1RASThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sets the RAS seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900." ::= { t1e1AlarmTableEntry 40 } t1e1RASAlarm OBJECT-TYPE SYNTAX INTEGER { t1e1RASAlarmOther(1), t1e1RASAlarmNone(2), t1e1RASAlarmExists(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This status indicates if a Remote (Yellow) Alarm exists." ::= { t1e1AlarmTableEntry 41 } t1e1AlarmResetTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sets the Alarm Reset Timer, this field can be set to any value in the range 0 to 900." ::= { t1e1AlarmTableEntry 42 } t1e1AlarmReset OBJECT-TYPE SYNTAX INTEGER { t1e1AlarmResetOther(1), t1e1AlarmResetClearAlarms(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This is used to clear the current alarm counts." ::= { t1e1AlarmTableEntry 43 } -- ddsNet section, contains DDS Network interface table ddsNetConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF DdsNetConfigTableEntry ACCESS not-accessible STATUS optional DESCRIPTION "The dds Network Interface Configuration Table." ::= { ddsNet 1 } ddsNetConfigTableEntry OBJECT-TYPE SYNTAX DdsNetConfigTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Network Interface Table." INDEX { ddsNetConfigNearIndex, ddsNetConfigFarIndex, ddsNetConfigIndex } ::= { ddsNetConfigTable 1 } DdsNetConfigTableEntry ::= SEQUENCE { ddsNetConfigNearIndex INTEGER, ddsNetConfigFarIndex INTEGER, ddsNetConfigIndex INTEGER, ddsNetDescription DisplayString, ddsNetRate INTEGER, ddsNetMode INTEGER, ddsNetTimingSource INTEGER, ddsNetRemComm INTEGER, ddsNetCircuitAssur INTEGER, ddsNetAntiStrTimer INTEGER } ddsNetConfigNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { ddsNetConfigTableEntry 1 } ddsNetConfigFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { ddsNetConfigTableEntry 2 } ddsNetConfigIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index into the ddsNetConfigTable." ::= { ddsNetConfigTableEntry 3 } ddsNetDescription OBJECT-TYPE SYNTAX DisplayString( SIZE(0..40) ) ACCESS read-write STATUS mandatory DESCRIPTION "Contains a textual description of the port." ::= { ddsNetConfigTableEntry 4 } ddsNetRate OBJECT-TYPE SYNTAX INTEGER { ddsNetRate2400(1), ddsNetRate4800(2), ddsNetRate9600(3), ddsNetRate19200(4), ddsNetRate38400(5), ddsNetRate56000(6), ddsNetRate64000(7) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is the identifier of the current DDS network rate. The values mean: ddsNetRate2400 the DDS network interface is operating at 2400bps ddsNetRate4800 the DDS network interface is operating at 4800bps ddsNetRate9600 the DDS network interface is operating at 9600bps ddsNetRate19200 the DDS network interface is operating at 19200bps ddsNetRate38400 the DDS network interface is operating at 38400bps ddsNetRate56000 the DDS network interface is operating at 56000bps ddsNetRate64000 the DDS network interface is operating at 64000bps" ::= { ddsNetConfigTableEntry 5 } ddsNetMode OBJECT-TYPE SYNTAX INTEGER { ddsNetModeNormal(1), ddsNetModeProprietaryTXPI(2), ddsNetMode64KClearChannel(3), ddsNetMode64KCCProprietaryTXPII(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable describes mode in which data is being sent from the DDS unit back towards the network. Changing the value of this variable can cause a loss of remote communications. The values mean: ddsNetModeNormal (DDS-I) normal data mode of operation ddsNetModeProprietaryTXPI (DDS-I) data being sent out on the DDS network is in a proprietary mode to allow for remote communications, rate adaption, and SYNC to ASYNC modes ddsNetMode64KClearChannel (DDS-II) A special case of DDS-II, where the line rate is 72K, the data rate is 64K, and there is no secondary channel. ddsNetMode64KCCProprietaryTXPII (DDS-II) A special case of DDS-II, where the line rate is 72K, the data rate is 64K, and there is no secondary channel. In addition, the data being sent out on the DDS network is in a proprietary mode to allow for remote communications, rate adaption, SYNC to ASYNC, and/or TDM modes." ::= { ddsNetConfigTableEntry 6 } ddsNetTimingSource OBJECT-TYPE SYNTAX INTEGER { ddsNetTimingNet(1), ddsNetTimingInt(2), ddsNetTimingDTE(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable describes the current timing source for the DDS network interface. The values mean: ddsNetTimingNet unit dependant upon network for DDS network interface timing ddsNetTimingInt unit supplying timing for DDS network interface ddsNetTimingDTE unit dependant upon DTE device for network interface timing" ::= { ddsNetConfigTableEntry 7 } ddsNetRemComm OBJECT-TYPE SYNTAX INTEGER { ddsNetRemCommEnabled(1), ddsNetRemCommDisabled(2), ddsNetRemCommNotAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable describes the current setting for the remote communications link. The values mean: ddsNetRemCommEnabled remote communications can be carried out end to end ddsNetRemCommDisabled remote communications are not allowed ddsNetRemCommNotAvailable this unit does not support remote communications" ::= { ddsNetConfigTableEntry 8 } ddsNetCircuitAssur OBJECT-TYPE SYNTAX INTEGER { ddsNetCircuitAssurEnabled(1), ddsNetCircuitAssurDisabled(2), ddsNetCircuitAssurNotAvailable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable describes the current setting for the circuit assurance option. The values mean: ddsNetCircuitAssurEnabled Circuit Assurance is enabled and the integrity of the DDS loop will be maintained ddsNetCircuitAssurDisabled Circuit Assurance is disabled ddsNetCircuitAssurNotAvailable this unit does not support Circuit Assurance" ::= { ddsNetConfigTableEntry 9 } ddsNetAntiStrTimer OBJECT-TYPE SYNTAX INTEGER { ddsNetAntiStrTimerOff(1), ddsNetAntiStrTimer10(2), ddsNetAntiStrTimer30(3), ddsNetAntiStrTimer60(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable describes the current setting for the anti streaming timer. The values mean: ddsNetAntiStrTimerOff the AntiStreaming Timer is off ddsNetAntiStrTimer10 the AntiStreaming Timer is set to 10 seconds ddsNetAntiStrTimer30 the AntiStreaming Timer is set to 30 seconds ddsNetAntiStrTimer60 ths AntiStreaming Timer is set to 60 seconds" ::= { ddsNetConfigTableEntry 10 } ddsNetAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF DdsNetAlarmTableEntry ACCESS not-accessible STATUS optional DESCRIPTION "The dds Network Interface Alarm Table." ::= { ddsNet 2 } ddsNetAlarmTableEntry OBJECT-TYPE SYNTAX DdsNetAlarmTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the ddsNetAlarmTable." INDEX { ddsNetAlarmNearIndex, ddsNetAlarmFarIndex, ddsNetAlarmIndex } ::= { ddsNetAlarmTable 1 } DdsNetAlarmTableEntry ::= SEQUENCE { ddsNetAlarmNearIndex INTEGER, ddsNetAlarmFarIndex INTEGER, ddsNetAlarmIndex INTEGER, ddsNetStatusSummary DisplayString, ddsNetAlarmSummary DisplayString, ddsNetLOSStatus INTEGER, ddsNetLOSCount INTEGER, ddsNetLOSThreshold INTEGER, ddsNetLOSAlarm INTEGER, ddsNetOOFStatus INTEGER, ddsNetOOFCount INTEGER, ddsNetOOFThreshold INTEGER, ddsNetOOFAlarm INTEGER, ddsNetOOSStatus INTEGER, ddsNetOOSCount INTEGER, ddsNetOOSThreshold INTEGER, ddsNetOOSAlarm INTEGER, ddsNetFDLStatus INTEGER, ddsNetFDLCount INTEGER, ddsNetFDLThreshold INTEGER, ddsNetFDLAlarm INTEGER, ddsNetAlarmResetTimer INTEGER, ddsNetAlarmReset INTEGER } ddsNetAlarmNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { ddsNetAlarmTableEntry 1 } ddsNetAlarmFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { ddsNetAlarmTableEntry 2 } ddsNetAlarmIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index into the ddsNetAlarmTable." ::= { ddsNetAlarmTableEntry 3 } ddsNetStatusSummary OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides a summary of the port status." ::= { ddsNetAlarmTableEntry 4 } ddsNetAlarmSummary OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides a summary of the port alarms." ::= { ddsNetAlarmTableEntry 5 } ddsNetLOSStatus OBJECT-TYPE SYNTAX INTEGER { ddsNetStatusLOSOther(1), ddsNetStatusNoLOS(2), ddsNetStatusLOS(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports if a Loss of Signal condition exists." ::= { ddsNetAlarmTableEntry 6 } ddsNetLOSCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This count contains the number of consecutive seconds the unit received signal has been interrupted." ::= { ddsNetAlarmTableEntry 7 } ddsNetLOSThreshold OBJECT-TYPE SYNTAX INTEGER { ddsNetLOSThresholdOther(1), ddsNetLOSThresholdNone(2), ddsNetLOSThreshold1(3), ddsNetLOSThreshold2(4), ddsNetLOSThreshold3(5), ddsNetLOSThreshold4(6), ddsNetLOSThreshold5(7), ddsNetLOSThreshold10(8), ddsNetLOSThreshold20(9), ddsNetLOSThreshold30(10) } ACCESS read-write STATUS mandatory DESCRIPTION "A period, measured in seconds, in which the DDS received signal is interrupted." ::= { ddsNetAlarmTableEntry 8 } ddsNetLOSAlarm OBJECT-TYPE SYNTAX INTEGER { ddsNetLOSAlarmOther(1), ddsNetLOSAlarmNone(2), ddsNetLOSAlarmThresholdExceeded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This status indicates if the Loss of Signal Seconds threshold is exceeded." ::= { ddsNetAlarmTableEntry 9 } ddsNetOOFStatus OBJECT-TYPE SYNTAX INTEGER { ddsNetStatusOOFOther(1), ddsNetStatusNoOOF(2), ddsNetStatusOOF(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports if an Out of Frame condition exists." ::= { ddsNetAlarmTableEntry 10 } ddsNetOOFCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This count contains the number of consecutive seconds the unit has received the out of frame code." ::= { ddsNetAlarmTableEntry 11 } ddsNetOOFThreshold OBJECT-TYPE SYNTAX INTEGER { ddsNetOOFThresholdOther(1), ddsNetOOFThresholdNone(2), ddsNetOOFThreshold1(3), ddsNetOOFThreshold2(4), ddsNetOOFThreshold3(5), ddsNetOOFThreshold4(6), ddsNetOOFThreshold5(7), ddsNetOOFThreshold10(8), ddsNetOOFThreshold20(9), ddsNetOOFThreshold30(10) } ACCESS read-write STATUS mandatory DESCRIPTION "A period, measured in seconds, in which the Out Of Frame code is received or a frame sync loss occurred." ::= { ddsNetAlarmTableEntry 12 } ddsNetOOFAlarm OBJECT-TYPE SYNTAX INTEGER { ddsNetOOFSAlarmOther(1), ddsNetOOFSAlarmNone(2), ddsNetOOFSAlarmThresholdExceeded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This status indicates if the Out of Frame Seconds threshold is exceeded." ::= { ddsNetAlarmTableEntry 13 } ddsNetOOSStatus OBJECT-TYPE SYNTAX INTEGER { ddsNetStatusOOSOther(1), ddsNetStatusNoOOS(2), ddsNetStatusOOS(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports if Out of Service codes are received." ::= { ddsNetAlarmTableEntry 14 } ddsNetOOSCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This count contains the number of consecutive seconds the unit has received the out of service code." ::= { ddsNetAlarmTableEntry 15 } ddsNetOOSThreshold OBJECT-TYPE SYNTAX INTEGER { ddsNetOOSThresholdOther(1), ddsNetOOSThresholdNone(2), ddsNetOOSThreshold1(3), ddsNetOOSThreshold2(4), ddsNetOOSThreshold3(5), ddsNetOOSThreshold4(6), ddsNetOOSThreshold5(7), ddsNetOOSThreshold10(8), ddsNetOOSThreshold20(9), ddsNetOOSThreshold30(10) } ACCESS read-write STATUS mandatory DESCRIPTION "A period, measured in seconds, in which the Out Of Service code is received." ::= { ddsNetAlarmTableEntry 16 } ddsNetOOSAlarm OBJECT-TYPE SYNTAX INTEGER { ddsNetOOSAlarmOther(1), ddsNetOOSAlarmNone(2), ddsNetOOSAlarmThresholdExceeded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This status indicates if the Out of Service Seconds threshold is exceeded." ::= { ddsNetAlarmTableEntry 17 } ddsNetFDLStatus OBJECT-TYPE SYNTAX INTEGER { ddsNetStatusFDLOther(1), ddsNetStatusNoFDL(2), ddsNetStatusFDL(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports if Facility Data Link errors have occurred." ::= { ddsNetAlarmTableEntry 18 } ddsNetFDLCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This count contains the number of consecutive seconds in which FDL errors have occurred." ::= { ddsNetAlarmTableEntry 19 } ddsNetFDLThreshold OBJECT-TYPE SYNTAX INTEGER { ddsNetFDLThresholdOther(1), ddsNetFDLThresholdNone(2), ddsNetFDLThreshold1(3), ddsNetFDLThreshold2(4), ddsNetFDLThreshold3(5), ddsNetFDLThreshold4(6), ddsNetFDLThreshold5(7), ddsNetFDLThreshold10(8), ddsNetFDLThreshold20(9), ddsNetFDLThreshold30(10) } ACCESS read-write STATUS mandatory DESCRIPTION "A period, measured in seconds, in which FDL errors have occurred." ::= { ddsNetAlarmTableEntry 20 } ddsNetFDLAlarm OBJECT-TYPE SYNTAX INTEGER { ddsNetFDLAlarmOther(1), ddsNetFDLAlarmNone(2), ddsNetFDLAlarmThresholdExceeded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This status indicates if the Facility Data Link threshold is exceeded." ::= { ddsNetAlarmTableEntry 21 } ddsNetAlarmResetTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Sets the Alarm Reset Timer, this field can be set to any value in the range 0 to 900." ::= { ddsNetAlarmTableEntry 22 } ddsNetAlarmReset OBJECT-TYPE SYNTAX INTEGER { ddsNetAlarmResetOther(1), ddsNetAlarmResetClearAlarms(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This is used to clear the current alarm counts." ::= { ddsNetAlarmTableEntry 23 } -- serialDte section serialDteConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SerialDteConfigTableEntry ACCESS not-accessible STATUS optional DESCRIPTION "The Serial DTE Config Table." ::= { serialDte 1 } serialDteConfigTableEntry OBJECT-TYPE SYNTAX SerialDteConfigTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the serial DTE Config Table." INDEX { serialDteConfigNearIndex, serialDteConfigFarIndex, serialDteConfigIndex } ::= { serialDteConfigTable 1 } SerialDteConfigTableEntry ::= SEQUENCE { serialDteConfigNearIndex INTEGER, serialDteConfigFarIndex INTEGER, serialDteConfigIndex INTEGER, serialDteDescription DisplayString, serialDteType INTEGER, serialDteRate INTEGER, serialDteInvertData INTEGER, serialDteFormat INTEGER, serialDteParity INTEGER, serialDteStopBit INTEGER, serialDteMode INTEGER, serialDteDSR INTEGER, serialDteDCD INTEGER, serialDteRTS INTEGER, serialDteRTSDelay INTEGER, serialDteDTR INTEGER, serialDteCTS INTEGER, serialDteV54 INTEGER, serialDteLL INTEGER, serialDteRL INTEGER, serialDteStartChannel INTEGER, serialDteNumberOfChannels INTEGER, serialDteTxClock INTEGER, serialDteBundle INTEGER, serialDteChannelRate INTEGER, serialDteInvertClock INTEGER } serialDteConfigNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { serialDteConfigTableEntry 1 } serialDteConfigFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { serialDteConfigTableEntry 2 } serialDteConfigIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index into the DteTable." ::= { serialDteConfigTableEntry 3 } serialDteDescription OBJECT-TYPE SYNTAX DisplayString( SIZE(0..40) ) ACCESS read-only STATUS mandatory DESCRIPTION "Contains a textual description of the port." ::= { serialDteConfigTableEntry 4 } serialDteType OBJECT-TYPE SYNTAX INTEGER { serialDteTypeOther(1), serialDteTypeV35(2), serialDteTypeRS232(3), serialDteTypeEIA530(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the DTE port type if applicable." ::= { serialDteConfigTableEntry 5 } serialDteRate OBJECT-TYPE SYNTAX INTEGER { serialDteRateOther(1), serialDteRate2400(2), serialDteRate4800(3), serialDteRate9600(4), serialDteRate19200(5), serialDteRate38400(6), serialDteRate52000(7), serialDteRate56000(8), serialDteRate57600(9), serialDteRate60000(10), serialDteRate64000(11), serialDteRate112000(12), serialDteRate128000(13), serialDteRate168000(14), serialDteRate192000(15), serialDteRate224000(16), serialDteRate256000(17), serialDteRate280000(18), serialDteRate320000(19), serialDteRate336000(20), serialDteRate384000(21), serialDteRate392000(22), serialDteRate448000(23), serialDteRate504000(24), serialDteRate512000(25), serialDteRate560000(26), serialDteRate576000(27), serialDteRate616000(28), serialDteRate640000(29), serialDteRate672000(30), serialDteRate704000(31), serialDteRate728000(32), serialDteRate768000(33), serialDteRate784000(34), serialDteRate832000(35), serialDteRate840000(36), serialDteRate896000(37), serialDteRate952000(38), serialDteRate960000(39), serialDteRate1008000(40), serialDteRate1024000(41), serialDteRate1064000(42), serialDteRate1088000(43), serialDteRate1120000(44), serialDteRate1152000(45), serialDteRate1176000(46), serialDteRate1216000(47), serialDteRate1232000(48), serialDteRate1280000(49), serialDteRate1288000(50), serialDteRate1344000(51), serialDteRate1400000(52), serialDteRate1408000(53), serialDteRate1456000(54), serialDteRate1472000(55), serialDteRate1512000(56), serialDteRate1536000(57), serialDteRate1568000(58), serialDteRate1600000(59), serialDteRate1624000(60), serialDteRate1664000(61), serialDteRate1680000(62), serialDteRate1728000(63), serialDteRate1736000(64), serialDteRate1792000(65), serialDteRate1856000(66), serialDteRate1920000(67), serialDteRate1984000(68), serialDteRate2048000(69), serialDteRate1200(70), serialDteRate14400(71), serialDteRate28800(72), serialDteRate48000(73), serialDteRate31200(74), serialDteRate115200(75) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the DTE port bit." ::= { serialDteConfigTableEntry 6 } serialDteInvertData OBJECT-TYPE SYNTAX INTEGER { serialDteInvertDataOther(1), serialDteInvertDataDisabled(2), serialDteInvertDataEnabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether transmit and receive are inverted at the port." ::= { serialDteConfigTableEntry 7 } serialDteFormat OBJECT-TYPE SYNTAX INTEGER { serialDteFormatOther(1), serialDteFormatSync(2), serialDteFormatAsync(3), serialDteFormatNotAvail(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable describes the current operations format of the DTE interface. The values mean: serialDteFormatSync The DTE interface is currently set to operate in Syncronous clocking format serialDteFormatAsync The DTE interface is currently set to operate in the Asyncronous clocking format serialDteFormatNotAvail The DTE interface operating format is not available" ::= { serialDteConfigTableEntry 8 } -- The DTE Parity is only valid when the DTE Mode is set to ASYNC serialDteParity OBJECT-TYPE SYNTAX INTEGER { serialDteParityOther(1), serialDteParityNone(2), serialDteParityOdd(3), serialDteParityEven(4), serialDteParityMark(5), serialDteParitySpace(6), serialDteParityNotAvail(7) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable describes the current parity selected for the DTE interface. This variable is only valid when the DTE Mode is set to ASYNC. The values mean: serialDteParityNone The DTE interface is currently set for no parity bit checking or generation serialDteParityOdd The DTE interface is currently set for odd parity serialDteParityEven The DTE interface is currently set for even parity serialDteParityMark The DTE interface is currently set for mark parity serialDteParitySpace The DTE interface is currently set for space parity serialDteParityNotAvail The parity setting on the DTE interface is not available." ::= { serialDteConfigTableEntry 9 } -- The Stop bit setting is only valid when the DTE interface is set to -- ASYNC operation. serialDteStopBit OBJECT-TYPE SYNTAX INTEGER { serialDteStopBitOther(1), serialDteStopBit1(2), serialDteStopBit2(3), serialDteStopBitNotAvail(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable describes the stop bit setting for the DTE interface. This variable is only valid when the DTE interface is set to ASYNC. The values mean: serialDteStopBit1 The DTE interface is configured to operate in the ASYNC mode with 1 stop bit serialDteStopBit2 The DTE interface is configured to operate in the ASYNC mode with 2 stop bits serialDteStopBitNotAvail The stop bit information is not available. The DTE interface is probably configured for synchronous operation." ::= { serialDteConfigTableEntry 10 } serialDteMode OBJECT-TYPE SYNTAX INTEGER { serialDteModeOther(1), serialDteModeDDSI(2), serialDteModeDDSII(3), serialDteModeTxpINormal(4), serialDteModeTxpITDM(5), serialDteModeTxpIINormal(6), serialDteModeTxpIITDM(7) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable describes mode in which data is being sent from the DDS unit back towards the network. " ::= { serialDteConfigTableEntry 11 } serialDteDSR OBJECT-TYPE SYNTAX INTEGER { serialDteDSROther(1), serialDteDSRTestOff(2), serialDteDSRForcedOn(3), serialDteDSRForcedOff(4), serialDteDSRInternal(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects DSR behavior." ::= { serialDteConfigTableEntry 12 } serialDteDCD OBJECT-TYPE SYNTAX INTEGER { serialDteDCDOther(1), serialDteDCDIdleOff(2), serialDteDCDForcedOn(3), serialDteDCDForcedOff(4), serialDteDCDInternal(5), serialDteDCDFarRTS(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects DCD behavior." ::= { serialDteConfigTableEntry 13 } serialDteRTS OBJECT-TYPE SYNTAX INTEGER { serialDteRTSOther(1), serialDteRTSNormal(2), serialDteRTSForcedOn(3), serialDteRTSExternal(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects RTS behavior." ::= { serialDteConfigTableEntry 14 } serialDteRTSDelay OBJECT-TYPE SYNTAX INTEGER { serialDteRTSDelayOther(1), serialDteRTSDelayNormal(2), serialDteRTSDelayLong(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects RTS to CTS transition delay." ::= { serialDteConfigTableEntry 15 } serialDteDTR OBJECT-TYPE SYNTAX INTEGER { serialDteDTROther(1), serialDteDTRFalse(2), serialDteDTRTrue(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports if DTR from the DTE device is false." ::= { serialDteConfigTableEntry 16 } serialDteCTS OBJECT-TYPE SYNTAX INTEGER { serialDteCTSOther(1), serialDteCTSForceTrue(2), serialDteCTSForceFalse(3), serialDteCTSInternal(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the control of the CTS signal at the port." ::= { serialDteConfigTableEntry 17 } serialDteV54 OBJECT-TYPE SYNTAX INTEGER { serialDteV54Other(1), serialDteV54Disable(2), serialDteV54Enable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies if the unit should respond to inband V.54 loop commands." ::= { serialDteConfigTableEntry 18 } serialDteLL OBJECT-TYPE SYNTAX INTEGER { serialDteLLOther(1), serialDteLLDisable(2), serialDteLLEnable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies if the unit should respond to local loop activation by the local loopback signal (EIA530 or RS-232 pin 18)." ::= { serialDteConfigTableEntry 19 } serialDteRL OBJECT-TYPE SYNTAX INTEGER { serialDteRLOther(1), serialDteRLDisable(2), serialDteRLEnable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies if the unit should respond to remote loop activation by the remote loopback signal (EIA530 or RS-232 pin 21)." ::= { serialDteConfigTableEntry 20 } serialDteStartChannel OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the starting channel for the interface." ::= { serialDteConfigTableEntry 21 } serialDteNumberOfChannels OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the number of channels allocated to the interface." ::= { serialDteConfigTableEntry 22 } serialDteTxClock OBJECT-TYPE SYNTAX INTEGER { serialDteTxClockOther(1), serialDteTxClockInternal(2), serialDteTxClockExternal(3), serialDteTxClockOversample(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies how the interface derives its transmit clock." ::= { serialDteConfigTableEntry 23 } serialDteBundle OBJECT-TYPE SYNTAX INTEGER { other(1), contiguous(2), alternate(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the allocation pattern of channels assigned to the serial port." ::= { serialDteConfigTableEntry 24 } serialDteChannelRate OBJECT-TYPE SYNTAX INTEGER { other(1), nx56k(2), nx64k(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the rate of all channels assigned to the serial port." ::= { serialDteConfigTableEntry 25 } serialDteInvertClock OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), enabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies if an inverted clock is used to send data from the serial port." ::= { serialDteConfigTableEntry 26 } serialDteAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF SerialDteAlarmTableEntry ACCESS not-accessible STATUS optional DESCRIPTION "The Serial DTE Alarm Table." ::= { serialDte 2 } serialDteAlarmTableEntry OBJECT-TYPE SYNTAX SerialDteAlarmTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the serial DTE Alarm Table." INDEX { serialDteAlarmNearIndex, serialDteAlarmFarIndex, serialDteAlarmIndex } ::= { serialDteAlarmTable 1 } SerialDteAlarmTableEntry ::= SEQUENCE { serialDteAlarmNearIndex INTEGER, serialDteAlarmFarIndex INTEGER, serialDteAlarmIndex INTEGER, serialDteDTRAlarmControl INTEGER, serialDteDTRAlarmStatus INTEGER, serialDteStatusSummary DisplayString, serialDteAlarmSummary DisplayString, serialDteASCStatus INTEGER, serialDteASCCount INTEGER, serialDteASCThreshold INTEGER, serialDteASCAlarm INTEGER, serialDteFDLStatus INTEGER, serialDteFDLCount INTEGER, serialDteFDLThreshold INTEGER, serialDteFDLAlarm INTEGER, serialDteLOSStatus INTEGER, serialDteLOSCount INTEGER, serialDteLOSThreshold INTEGER, serialDteLOSAlarm INTEGER } serialDteAlarmNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { serialDteAlarmTableEntry 1 } serialDteAlarmFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { serialDteAlarmTableEntry 2 } serialDteAlarmIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index into the serialDteAlarmTable." ::= { serialDteAlarmTableEntry 3 } serialDteDTRAlarmControl OBJECT-TYPE SYNTAX INTEGER { serialDteDTRAlarmOther(1), serialDteDTRAlarmDisable(2), serialDteDTRAlarmEnable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies if the unit should alarm on loss of DTR." ::= { serialDteAlarmTableEntry 4 } serialDteDTRAlarmStatus OBJECT-TYPE SYNTAX INTEGER { serialDteDTRAlarmOther(1), serialDteDTRAlarmNone(2), serialDteDTRAlarmActive(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This status indicates a DTR Loss alarm is active." ::= { serialDteAlarmTableEntry 5 } serialDteStatusSummary OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides a summary of the port status." ::= { serialDteAlarmTableEntry 6 } serialDteAlarmSummary OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides a summary of the port alarms." ::= { serialDteAlarmTableEntry 7 } serialDteASCStatus OBJECT-TYPE SYNTAX INTEGER { serialDteStatusASCOther(1), serialDteStatusNoASC(2), serialDteStatusASC(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports if an ASC condition exists on the interface." ::= { serialDteAlarmTableEntry 8 } serialDteASCCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This count contains the number of ASC seconds received by the interface." ::= { serialDteAlarmTableEntry 9 } serialDteASCThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of ASC seconds that must be received before an alarm is declared." ::= { serialDteAlarmTableEntry 10 } serialDteASCAlarm OBJECT-TYPE SYNTAX INTEGER { serialDteASCAlarmOther(1), serialDteASCAlarmNone(2), serialDteASCAlarmThresholdExceeded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This status indicates if the ASC Seconds threshold is exceeded." ::= { serialDteAlarmTableEntry 11 } serialDteFDLStatus OBJECT-TYPE SYNTAX INTEGER { serialDteStatusFDLOther(1), serialDteStatusNoFDL(2), serialDteStatusFDL(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports if an FDL error condition exists on the interface." ::= { serialDteAlarmTableEntry 12 } serialDteFDLCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This count contains the number of FDL errored seconds received by the interface." ::= { serialDteAlarmTableEntry 13 } serialDteFDLThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of FDL errored seconds that must be received before an alarm is declared." ::= { serialDteAlarmTableEntry 14 } serialDteFDLAlarm OBJECT-TYPE SYNTAX INTEGER { serialDteFDLAlarmOther(1), serialDteFDLAlarmNone(2), serialDteFDLAlarmThresholdExceeded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This status indicates if the FDL Errored Seconds threshold is exceeded." ::= { serialDteAlarmTableEntry 15 } serialDteLOSStatus OBJECT-TYPE SYNTAX INTEGER { serialDteStatusLOSOther(1), serialDteStatusNoLOS(2), serialDteStatusLOS(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Reports if an LOS condition exists on the interface." ::= { serialDteAlarmTableEntry 16 } serialDteLOSCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This count contains the number of LOS seconds received by the interface." ::= { serialDteAlarmTableEntry 17 } serialDteLOSThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of LOS seconds that must be received before an alarm is declared." ::= { serialDteAlarmTableEntry 18 } serialDteLOSAlarm OBJECT-TYPE SYNTAX INTEGER { serialDteLOSAlarmOther(1), serialDteLOSAlarmNone(2), serialDteLOSAlarmThresholdExceeded(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This status indicates if the LOS Seconds threshold is exceeded." ::= { serialDteAlarmTableEntry 19 } -- analog DTE section analogDteTable OBJECT-TYPE SYNTAX SEQUENCE OF AnalogDteTableEntry ACCESS not-accessible STATUS optional DESCRIPTION "The Analog DTE Table." ::= { analogDte 1 } analogDteTableEntry OBJECT-TYPE SYNTAX AnalogDteTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Analog DTE Table." INDEX { analogDteNearIndex, analogDteFarIndex, analogDteIndex } ::= { analogDteTable 1 } AnalogDteTableEntry ::= SEQUENCE { analogDteNearIndex INTEGER, analogDteFarIndex INTEGER, analogDteIndex INTEGER, analogDteDescription DisplayString, analogDteCardType INTEGER, analogDteMode INTEGER, analogDteState INTEGER, analogDteElementID DisplayString, analogDteSignalling INTEGER, analogDteDNISDelay INTEGER, analogDteTxGain INTEGER, analogDteRxGain INTEGER } analogDteNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { analogDteTableEntry 1 } analogDteFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { analogDteTableEntry 2 } analogDteIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index into the analogDteTable." ::= { analogDteTableEntry 3 } analogDteDescription OBJECT-TYPE SYNTAX DisplayString( SIZE(0..40) ) ACCESS read-only STATUS mandatory DESCRIPTION "Contains a textual description of the port." ::= { analogDteTableEntry 4 } analogDteCardType OBJECT-TYPE SYNTAX INTEGER { analogDteCardTypeOther(1), analogDteCardTypeFXS(2), analogDteCardTypeFXO(3), analogDteCardType4WEM(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the analog DTE card type." ::= { analogDteTableEntry 5 } analogDteMode OBJECT-TYPE SYNTAX INTEGER { analogDteModeOther(1), analogDteModeSpare(2), analogDteModeActive(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects whether the port is actively assigned to a netowrk channel or not used." ::= { analogDteTableEntry 6 } analogDteState OBJECT-TYPE SYNTAX INTEGER { analogDteStateOther(1), analogDteStateIdle(2), analogDteStateBusy(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the port status as either in the Busy or Idle state." ::= { analogDteTableEntry 7 } analogDteElementID OBJECT-TYPE SYNTAX DisplayString( SIZE(0..20) ) ACCESS read-write STATUS mandatory DESCRIPTION "This object signifies the name of the device." ::= { analogDteTableEntry 8 } analogDteSignalling OBJECT-TYPE SYNTAX INTEGER { analogDteSignallingOther(1), analogDteSignallingFXSLS(2), analogDteSignallingFXSGS(3), analogDteSignallingUVG(4), analogDteSignallingMEGLS(5), analogDteSignallingMEGGS(6), analogDteSignallingMEGRLS(7), analogDteSignallingMEGRGS(8), analogDteSignallingPLAR(9), analogDteSignallingSLC96(10), analogDteSignallingDIDDNIS(11), analogDteSignallingDNISWLS(12), analogDteSignallingDNISDLS(13), analogDteSignallingDNISWRLS(14), analogDteSignallingDNISDRLS(15), analogDteSignallingDNISWGS(16), analogDteSignallingDNISDGS(17), analogDteSignallingDNISWRGS(18), analogDteSignallingDNISDRGS(19), analogDteSignallingFXOLS(20), analogDteSignallingFXOGS(21), analogDteSignallingFXOUVG(22), analogDteSignallingFXOUVGR(23), analogDteSignalling4WEMTYPE1(24), analogDteSignalling4WEMTYPE2(25), analogDteSignalling4WEMTYPE3(26), analogDteSignalling4WEMTYPE4(27), analogDteSignalling4WEMTYPE5(28), analogDteSignalling4WEMTO(29) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the supervisory operation of the port." ::= { analogDteTableEntry 9 } analogDteDNISDelay OBJECT-TYPE SYNTAX INTEGER { analogDteDNISDelayOther(1), analogDteDNISDelay1Second(2), analogDteDNISDelay2Seconds(3), analogDteDNISDelay3Seconds(4), analogDteDNISDelay4Seconds(5), analogDteDNISDelay5Seconds(6) } ACCESS read-write STATUS mandatory DESCRIPTION "If the signalling mode has a delay, it can be set from 1 to 5 seconds." ::= { analogDteTableEntry 10 } analogDteTxGain OBJECT-TYPE SYNTAX INTEGER { analogDteTxGainOther(1), analogDteTxGain3DB(2), analogDteTxGain2DB(3), analogDteTxGain1DB(4), analogDteTxGain0DB(5), analogDteTxGainm1DB(6), analogDteTxGainm2DB(7), analogDteTxGainm3DB(8), analogDteTxGainm4DB(9), analogDteTxGainm5DB(10), analogDteTxGainm6DB(11), analogDteTxGainm7DB(12), analogDteTxGainm8DB(13), analogDteTxGainm9DB(14), analogDteTxGainm10DB(15) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the transmit gain. Values prefixed with m are negative." ::= { analogDteTableEntry 11 } analogDteRxGain OBJECT-TYPE SYNTAX INTEGER { analogDteRxGainOther(1), analogDteRxGain2DB(2), analogDteRxGain1DB(3), analogDteRxGain0DB(4), analogDteRxGainm1DB(5), analogDteRxGainm2DB(6), analogDteRxGainm3DB(7), analogDteRxGainm4DB(8), analogDteRxGainm5DB(9), analogDteRxGainm6DB(10), analogDteRxGainm7DB(11), analogDteRxGainm8DB(12), analogDteRxGainm9DB(13), analogDteRxGainm10DB(14), analogDteRxGainm11DB(15), analogDteRxGainm12DB(16), analogDteRxGainm13DB(17), analogDteRxGainm14DB(18), analogDteRxGainm15DB(19), analogDteRxGainm16DB(20) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the receive gain. Values prefixed with m are negative." ::= { analogDteTableEntry 12 } -- connection table -- allows for configuration/connection of dte ports to network ports connectionTable OBJECT-TYPE SYNTAX SEQUENCE OF ConnectionTableEntry ACCESS not-accessible STATUS optional DESCRIPTION "The connection table." ::= { connection 1 } connectionTableEntry OBJECT-TYPE SYNTAX ConnectionTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the connection table." INDEX { connectionNearIndex, connectionFarIndex, connectionTableIndex } ::= { connectionTable 1 } ConnectionTableEntry ::= SEQUENCE { connectionNearIndex INTEGER, connectionFarIndex INTEGER, connectionTableIndex INTEGER, connectionTableDescription DisplayString } connectionNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { connectionTableEntry 1 } connectionFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { connectionTableEntry 2 } connectionTableIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into the connection table." ::= { connectionTableEntry 3 } connectionTableDescription OBJECT-TYPE SYNTAX DisplayString(SIZE(0..60)) ACCESS read-only STATUS mandatory DESCRIPTION "A description of the connection." ::= { connectionTableEntry 4 } connectionChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF ConnectionChannelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The channel-level connection table." ::= { connection 2 } connectionChannelEntry OBJECT-TYPE SYNTAX ConnectionChannelEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the connectionChannelTable." INDEX { connectionChannelNearIndex, connectionChannelFarIndex, connectionChannelLineIndex, connectionChannelIndex } ::= { connectionChannelTable 1 } ConnectionChannelEntry ::= SEQUENCE { connectionChannelNearIndex INTEGER, connectionChannelFarIndex INTEGER, connectionChannelLineIndex INTEGER, connectionChannelIndex INTEGER, channelInterfaceAssignment INTEGER, channelInterfaceDescription DisplayString, channelInterfaceChannel INTEGER, channelSignalling INTEGER } connectionChannelNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { connectionChannelEntry 1 } connectionChannelFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { connectionChannelEntry 2 } connectionChannelLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects instance of line." ::= { connectionChannelEntry 3 } connectionChannelIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into the connection table." ::= { connectionChannelEntry 4 } channelInterfaceAssignment OBJECT-TYPE SYNTAX INTEGER { other(1), unassigned(2), dTE(3), remComm(4), port1(5), port2(6), port3(7), port4(8), port5(9), port6(10), port7(11), port8(12), port9(13), port10(14), port11(15), port12(16), port13(17), port14(18), port15(19), port16(20), port17(21), port18(22), port19(23), port20(24), port21(25), port22(26), port23(27), port24(28), port25(29), port26(30), port27(31), port28(32), port29(33), port30(34), port31(35), port32(36), slot2PortA(37), slot2PortB(38), slot3PortA(39), slot3PortB(40), slot4PortA(41), slot4PortB(42), slot5PortA(43), slot5PortB(44), slot6PortA(45), slot6PortB(46), slot2Dsu1PortA(47), slot2Dsu1PortB(48), slot2Dsu2PortA(49), slot2Dsu2PortB(50), slot2Dsu3PortA(51), slot2Dsu3PortB(52), slot2Dsu4PortA(53), slot2Dsu4PortB(54), slot2Dsu5PortA(55), slot2Dsu5PortB(56), slot2Dsu6PortA(57), slot2Dsu6PortB(58), slot3Dsu1PortA(59), slot3Dsu1PortB(60), slot3Dsu2PortA(61), slot3Dsu2PortB(62), slot3Dsu3PortA(63), slot3Dsu3PortB(64), slot3Dsu4PortA(65), slot3Dsu4PortB(66), slot3Dsu5PortA(67), slot3Dsu5PortB(68), slot3Dsu6PortA(69), slot3Dsu6PortB(70), slot4Dsu1PortA(71), slot4Dsu1PortB(72), slot4Dsu2PortA(73), slot4Dsu2PortB(74), slot4Dsu3PortA(75), slot4Dsu3PortB(76), slot4Dsu4PortA(77), slot4Dsu4PortB(78), slot4Dsu5PortA(79), slot4Dsu5PortB(80), slot4Dsu6PortA(81), slot4Dsu6PortB(82), slot5Dsu1PortA(83), slot5Dsu1PortB(84), slot5Dsu2PortA(85), slot5Dsu2PortB(86), slot5Dsu3PortA(87), slot5Dsu3PortB(88), slot5Dsu4PortA(89), slot5Dsu4PortB(90), slot5Dsu5PortA(91), slot5Dsu5PortB(92), slot5Dsu6PortA(93), slot5Dsu6PortB(94), slot6Dsu1PortA(95), slot6Dsu1PortB(96), slot6Dsu2PortA(97), slot6Dsu2PortB(98), slot6Dsu3PortA(99), slot6Dsu3PortB(100), slot6Dsu4PortA(101), slot6Dsu4PortB(102), slot6Dsu5PortA(103), slot6Dsu5PortB(104), slot6Dsu6PortA(105), slot6Dsu6PortB(106) } ACCESS read-write STATUS mandatory DESCRIPTION "The channel assignment." ::= { connectionChannelEntry 5 } channelInterfaceDescription OBJECT-TYPE SYNTAX DisplayString(SIZE(0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Contains a description of the interface channel connection." ::= { connectionChannelEntry 6 } channelInterfaceChannel OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Displays the corresponding channel of the interface channel connection." ::= { connectionChannelEntry 7 } channelSignalling OBJECT-TYPE SYNTAX INTEGER { other(1), clearChannel(2), robbedBit(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Allows a selection of Clear Channel or Robbed Bit signalling for each DS0." ::= { connectionChannelEntry 8 } -- maintenance section -- controls tests -- -- BERT Table -- bertTable OBJECT-TYPE SYNTAX SEQUENCE OF BertTableEntry ACCESS not-accessible STATUS optional DESCRIPTION "BERT control table." ::= { maintenance 1 } bertTableEntry OBJECT-TYPE SYNTAX BertTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the BERT control table." INDEX { bertNearIndex, bertFarIndex, bertIndex } ::= { bertTable 1 } BertTableEntry ::= SEQUENCE { bertNearIndex INTEGER, bertFarIndex INTEGER, bertIndex INTEGER, bertPattern INTEGER, bertLength INTEGER, bertPatternSync INTEGER, bertElapsedTime INTEGER, bertBitErrors INTEGER, bertErroredSeconds INTEGER, bertPercentEFS INTEGER, bertCommand INTEGER } bertNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { bertTableEntry 1 } bertFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { bertTableEntry 2 } bertIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into the BERT control table. Selects which BERT chip to use." ::= { bertTableEntry 3 } bertPattern OBJECT-TYPE SYNTAX INTEGER { bertPatternOther(1), bertPatternQRSS(2), bertPattern63(3), bertPattern511(4), bertPattern2047(5), bertPattern215(6), bertPattern220(7), bertPattern223(8), bertPattern1in8(9), bertPattern3in24(10), bertPatternALT(11), bertPatternCLEAR(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the test pattern to be used." ::= { bertTableEntry 4 } bertLength OBJECT-TYPE SYNTAX INTEGER { bertLengthOther(1), bertLength15minutes(2), bertLength30minutes(3), bertLength60minutes(4), bertLength24hours(5), bertLengthContinuous(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies how long the test should run." ::= { bertTableEntry 5 } bertPatternSync OBJECT-TYPE SYNTAX INTEGER { bertPatternSyncOther(1), bertPatternSyncNoTest(2), bertPatternSyncNoSync(3), bertPatternSyncInsync(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the current state of pattern sync during a test." ::= { bertTableEntry 6 } bertElapsedTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Displays the amount of time elapsed since a timed test began in seconds." ::= { bertTableEntry 7 } bertBitErrors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Displays the total number of bit errors detected since the test began." ::= { bertTableEntry 8 } bertErroredSeconds OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Displays the number of asynchronous errored seconds that have been detected since the test began." ::= { bertTableEntry 9 } bertPercentEFS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Displays a ratio derived from the number of error free seconds divided by the number of seconds accumulated in elapsed time." ::= { bertTableEntry 10 } bertCommand OBJECT-TYPE SYNTAX INTEGER { bertCommandOther(1), bertCommandStart(2), bertCommandStop(3), bertCommandResetErrors(4), bertCommandInjectError(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Issues a test command for the interface." ::= { bertTableEntry 11 } bertInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF BertInterfaceTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "BERT control interface table." ::= { maintenance 2 } bertInterfaceTableEntry OBJECT-TYPE SYNTAX BertInterfaceTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the BERT control interface table." INDEX { bertInterfaceNearIndex, bertInterfaceFarIndex, bertChipIndex, bertInterfaceIndex } ::= { bertInterfaceTable 1 } BertInterfaceTableEntry ::= SEQUENCE { bertInterfaceNearIndex INTEGER, bertInterfaceFarIndex INTEGER, bertChipIndex INTEGER, bertInterfaceIndex INTEGER, bertInterfaceSetting INTEGER } bertInterfaceNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { bertInterfaceTableEntry 1 } bertInterfaceFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { bertInterfaceTableEntry 2 } bertChipIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects which BERT chip to use." ::= { bertInterfaceTableEntry 3 } bertInterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index into the MIB-II interfaces table; the interface for the BERT settings." ::= { bertInterfaceTableEntry 4 } bertInterfaceSetting OBJECT-TYPE SYNTAX INTEGER { bertInterfaceSettingOther(1), bertInterfaceSettingIdle(2), bertInterfaceSettingChannel1(3), bertInterfaceSettingChannel2(4), bertInterfaceSettingChannel3(5), bertInterfaceSettingChannel4(6), bertInterfaceSettingChannel5(7), bertInterfaceSettingChannel6(8), bertInterfaceSettingChannel7(9), bertInterfaceSettingChannel8(10), bertInterfaceSettingChannel9(11), bertInterfaceSettingChannel10(12), bertInterfaceSettingChannel11(13), bertInterfaceSettingChannel12(14), bertInterfaceSettingChannel13(15), bertInterfaceSettingChannel14(16), bertInterfaceSettingChannel15(17), bertInterfaceSettingChannel16(18), bertInterfaceSettingChannel17(19), bertInterfaceSettingChannel18(20), bertInterfaceSettingChannel19(21), bertInterfaceSettingChannel20(22), bertInterfaceSettingChannel21(23), bertInterfaceSettingChannel22(24), bertInterfaceSettingChannel23(25), bertInterfaceSettingChannel24(26), bertInterfaceSettingChannel25(27), bertInterfaceSettingChannel26(28), bertInterfaceSettingChannel27(29), bertInterfaceSettingChannel28(30), bertInterfaceSettingChannel29(31), bertInterfaceSettingChannel30(32), bertInterfaceSettingChannel31(33), bertInterfaceSettingChannel32(34), bertInterfaceSettingNet(35), bertInterfaceSettingDTE(36), bertInterfaceSettingNotEnabled(37) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the interface for the BERT chip." ::= { bertInterfaceTableEntry 5 } -- -- Test Table -- testTable OBJECT-TYPE SYNTAX SEQUENCE OF TestTableEntry ACCESS not-accessible STATUS optional DESCRIPTION "Test control table." ::= { maintenance 3 } testTableEntry OBJECT-TYPE SYNTAX TestTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the testTable." INDEX { testNearIndex, testFarIndex, testTableIndex } ::= { testTable 1 } TestTableEntry ::= SEQUENCE { testNearIndex INTEGER, testFarIndex INTEGER, testTableIndex INTEGER, testType INTEGER, testLoopDirection INTEGER, testFarLLBFraming INTEGER } testNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { testTableEntry 1 } testFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { testTableEntry 2 } testTableIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into the testTable, one entry for each interface." ::= { testTableEntry 3 } testType OBJECT-TYPE SYNTAX INTEGER { testTypeOther(1), testTypeNoTest(2), testTypePLB(3), testTypeLLB(4), testtypeMLB(5), testTypeFarPLB(6), testTypeFarLLB(7), testTypeFarMLB(8), testTypePortLoop(9), testTypeV54Loop(10), testTypeFarV54Loop(11) } ACCESS read-write STATUS mandatory DESCRIPTION "Identifies the test type for the interface." ::= { testTableEntry 4 } testLoopDirection OBJECT-TYPE SYNTAX INTEGER { testLoopOther(1), testLoopUnidirectional(2), testLoopBidirectional(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is the identifier of the current unit loop mode. The values mean: testLoopUnidirectional Line, Data, and V54 loops will be unidirectional Local loop will be bidirectional testLoopBidirectional All loops will be bidirectional" ::= { testTableEntry 5 } testFarLLBFraming OBJECT-TYPE SYNTAX INTEGER { testFarLLBFramingOther(1), testFarLLBFramingUnframed(2), testFarLLBFramingFramed(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This setting, for Far LLB tests on T1 lines, must match the far end unit loop code framing." ::= { testTableEntry 6 } -- performance section -- performance section performance24Table OBJECT-TYPE SYNTAX SEQUENCE OF Performance24TableEntry ACCESS not-accessible STATUS optional DESCRIPTION "Performance table, contains TR54016 standard and enhanced data." ::= { performance 1 } performance24TableEntry OBJECT-TYPE SYNTAX Performance24TableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the performance24Table." INDEX { performance24NearIndex, performance24FarIndex, performance24InterfaceIndex, performance24Index } ::= { performance24Table 1 } Performance24TableEntry ::= SEQUENCE { performance24NearIndex INTEGER, performance24FarIndex INTEGER, performance24InterfaceIndex INTEGER, performance24Index INTEGER, performance24ES INTEGER, performance24BES INTEGER, performance24SES INTEGER, performance24UAS INTEGER, performance24LOFC INTEGER, performance24CSS INTEGER, performance24CRCES INTEGER, performance24OOFS INTEGER, performance24LOSS INTEGER, performance24AISS INTEGER, performance24RAS INTEGER, performance24BPVS INTEGER } performance24NearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { performance24TableEntry 1 } performance24FarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { performance24TableEntry 2 } performance24InterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the interface." ::= { performance24TableEntry 3 } performance24Index OBJECT-TYPE SYNTAX INTEGER { performance24Summary(1), performance24Current(2), performance24period1(3), performance24period2(4), performance24period3(5), performance24period4(6), performance24period5(7), performance24period6(8), performance24period7(9), performance24period8(10), performance24period9(11), performance24period10(12), performance24period11(13), performance24period12(14), performance24period13(15), performance24period14(16), performance24period15(17), performance24period16(18), performance24period17(19), performance24period18(20), performance24period19(21), performance24period20(22), performance24period21(23), performance24period22(24), performance24period23(25), performance24period24(26), performance24period25(27), performance24period26(28), performance24period27(29), performance24period28(30), performance24period29(31), performance24period30(32), performance24period31(33), performance24period32(34), performance24period33(35), performance24period34(36), performance24period35(37), performance24period36(38), performance24period37(39), performance24period38(40), performance24period39(41), performance24period40(42), performance24period41(43), performance24period42(44), performance24period43(45), performance24period44(46), performance24period45(47), performance24period46(48), performance24period47(49), performance24period48(50), performance24period49(51), performance24period50(52), performance24period51(53), performance24period52(54), performance24period53(55), performance24period54(56), performance24period55(57), performance24period56(58), performance24period57(59), performance24period58(60), performance24period59(61), performance24period60(62), performance24period61(63), performance24period62(64), performance24period63(65), performance24period64(66), performance24period65(67), performance24period66(68), performance24period67(69), performance24period68(70), performance24period69(71), performance24period70(72), performance24period71(73), performance24period72(74), performance24period73(75), performance24period74(76), performance24period75(77), performance24period76(78), performance24period77(79), performance24period78(80), performance24period79(81), performance24period80(82), performance24period81(83), performance24period82(84), performance24period83(85), performance24period84(86), performance24period85(87), performance24period86(88), performance24period87(89), performance24period88(90), performance24period89(91), performance24period90(92), performance24period91(93), performance24period92(94), performance24period93(95), performance24period94(96), performance24period95(97), performance24period96(98) } ACCESS read-only STATUS mandatory DESCRIPTION "The index into the 24-hour performance table." ::= { performance24TableEntry 4 } performance24ES OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Errored Seconds for the 15-minute period." ::= { performance24TableEntry 5 } performance24BES OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bursty Errored Seconds for the 15-minute period." ::= { performance24TableEntry 6 } performance24SES OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Severely Errored Seconds for the 15-minute period." ::= { performance24TableEntry 7 } performance24UAS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Unavailable Seconds for the 15-minute period." ::= { performance24TableEntry 8 } performance24LOFC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Loss of Frame Counts for the 15-minute period." ::= { performance24TableEntry 9 } performance24CSS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Controlled Slip Seconds for the 15-minute period." ::= { performance24TableEntry 10 } performance24CRCES OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of CRC Errored Seconds for the 15-minute period." ::= { performance24TableEntry 11 } performance24OOFS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Out of Frame Seconds for the 15-minute period." ::= { performance24TableEntry 12 } performance24LOSS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Loss of Signal Seconds for the 15-minute period." ::= { performance24TableEntry 13 } performance24AISS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Alarm Indication Signal Seconds for the 15-minute period." ::= { performance24TableEntry 14 } performance24RAS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Remote Alarm (Yellow) Seconds for the 15-minute period." ::= { performance24TableEntry 15 } performance24BPVS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bipolar Violation Seconds for the 15-minute period." ::= { performance24TableEntry 16 } performance30Table OBJECT-TYPE SYNTAX SEQUENCE OF Performance30TableEntry ACCESS not-accessible STATUS optional DESCRIPTION "Performance table, contains TR54016 standard and enhanced 30-day data." ::= { performance 2 } performance30TableEntry OBJECT-TYPE SYNTAX Performance30TableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the performance30Table." INDEX { performance30NearIndex, performance30FarIndex, performance30InterfaceIndex, performance30Index } ::= { performance30Table 1 } Performance30TableEntry ::= SEQUENCE { performance30NearIndex INTEGER, performance30FarIndex INTEGER, performance30InterfaceIndex INTEGER, performance30Index INTEGER, performance30ES INTEGER, performance30BES INTEGER, performance30SES INTEGER, performance30UAS INTEGER, performance30LOFC INTEGER, performance30CSS INTEGER, performance30CRCES INTEGER, performance30OOFS INTEGER, performance30LOSS INTEGER, performance30AISS INTEGER, performance30RAS INTEGER, performance30BPVS INTEGER } performance30NearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { performance30TableEntry 1 } performance30FarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { performance30TableEntry 2 } performance30InterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the interface." ::= { performance30TableEntry 3 } performance30Index OBJECT-TYPE SYNTAX INTEGER { performance30Summary(1), performance30day1(2), performance30day2(3), performance30day3(4), performance30day4(5), performance30day5(6), performance30day6(7), performance30day7(8), performance30day8(9), performance30day9(10), performance30day10(11), performance30day11(12), performance30day12(13), performance30day13(14), performance30day14(15), performance30day15(16), performance30day16(17), performance30day17(18), performance30day18(19), performance30day19(20), performance30day20(21), performance30day21(22), performance30day22(23), performance30day23(24), performance30day24(25), performance30day25(26), performance30day26(27), performance30day27(28), performance30day28(29), performance30day29(30), performance30day30(31) } ACCESS read-only STATUS mandatory DESCRIPTION "The index into the 30-day performance table." ::= { performance30TableEntry 4 } performance30ES OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Errored Seconds for the 1-day period." ::= { performance30TableEntry 5 } performance30BES OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bursty Errored Seconds for the 1-day period." ::= { performance30TableEntry 6 } performance30SES OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Severely Errored Seconds for the 1-day period." ::= { performance30TableEntry 7 } performance30UAS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Unavailable Seconds for the 1-day period." ::= { performance30TableEntry 8 } performance30LOFC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Loss of Frame Counts for the 1-day period." ::= { performance30TableEntry 9 } performance30CSS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Controlled Slip Seconds for the 1-day period." ::= { performance30TableEntry 10 } performance30CRCES OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of CRC Errored Seconds for the 1-day period." ::= { performance30TableEntry 11 } performance30OOFS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Out of Frame Seconds for the 1-day period." ::= { performance30TableEntry 12 } performance30LOSS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Loss of Signal Seconds for the 1-day period." ::= { performance30TableEntry 13 } performance30AISS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Alarm Indication Signal Seconds for the 1-day period." ::= { performance30TableEntry 14 } performance30RAS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Remote Alarm (Yellow) Seconds for the 1-day period." ::= { performance30TableEntry 15 } performance30BPVS OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bipolar Violation Seconds for the 1-day period." ::= { performance30TableEntry 16 } -- itable -- requests a list of all interfaces on a device iTable OBJECT-TYPE SYNTAX SEQUENCE OF ITableEntry ACCESS not-accessible STATUS optional DESCRIPTION "The interface table." ::= { itable 1 } iTableEntry OBJECT-TYPE SYNTAX ITableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the interface table." INDEX { iTableNearIndex, iTableFarIndex, iTableIndex } ::= { iTable 1 } ITableEntry ::= SEQUENCE { iTableNearIndex INTEGER, iTableFarIndex INTEGER, iTableIndex INTEGER, iDescription DisplayString, iType INTEGER, iSlot INTEGER, iPort INTEGER, iStatus INTEGER } iTableNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { iTableEntry 1 } iTableFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { iTableEntry 2 } iTableIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into the interface table, used for addressing in above tables." ::= { iTableEntry 3 } iDescription OBJECT-TYPE SYNTAX DisplayString( SIZE(0..80) ) ACCESS read-only STATUS mandatory DESCRIPTION "Description of the interface." ::= { iTableEntry 4 } iType OBJECT-TYPE SYNTAX INTEGER { disabled(0), v35(1), eia530(2), rs232(3), voice(4), hsdata(5), dualt1dte(6), dualddsv1(7), hexdds(8), ocudp(9), x21(10), dualddsv2(11), rfdl(128), alt(129), t1dte(130), didte(131), t1ntw(132), e1ntw(133), ddsntw(134), ddsdte(135), ddsdbu(136), fxs(137), fxo(138), eandm(139), e1sig(192) } ACCESS read-only STATUS mandatory DESCRIPTION "Enumerated interface type." ::= { iTableEntry 5 } iSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device-dependent slot in which the interface resides." ::= { iTableEntry 6 } iPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device-dependent port in which the interface resides." ::= { iTableEntry 7 } iStatus OBJECT-TYPE SYNTAX INTEGER { iStatusOther(1), iStatusOK(2), iStatusErrored(3), iStatusAlarmed(4), iStatusTesting(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of the interface." ::= { iTableEntry 8 } -- traplog -- a table of the most recent snmp traps -- note that the near and far indicies are simply elements in the table, -- not indicies as in the above tables... traplogTable OBJECT-TYPE SYNTAX SEQUENCE OF TraplogEntry ACCESS not-accessible STATUS optional DESCRIPTION "The traplog table." ::= { traplog 1 } traplogEntry OBJECT-TYPE SYNTAX TraplogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the traplog table." INDEX { traplogIndex } ::= { traplogTable 1 } TraplogEntry ::= SEQUENCE { traplogIndex INTEGER, traplogNearIndex INTEGER, traplogFarIndex INTEGER, traplogInterfaceIndex INTEGER, traplogTrapNum INTEGER, traplogTimeStamp DisplayString, traplogDeviceType INTEGER } traplogIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into the traplog table." ::= { traplogEntry 1 } traplogNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the near device." ::= { traplogEntry 2 } traplogFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the far device." ::= { traplogEntry 3 } traplogInterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the interface." ::= { traplogEntry 4 } traplogTrapNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The SNMP trap id." ::= { traplogEntry 5 } traplogTimeStamp OBJECT-TYPE SYNTAX DisplayString(SIZE(0..40)) ACCESS read-only STATUS mandatory DESCRIPTION "Time the SNMP was generated." ::= { traplogEntry 6 } traplogDeviceType OBJECT-TYPE SYNTAX INTEGER { other(1), none(2), t12000(3), e12048(4), e13021(5), t13000(6), t13001(7), t13002(8), t13030(9), t13060(10), t13101(11), t13102(12), t13111(13), t13112(14), dds4001(15), dds4101(16), dds4051(17), dds4151(18), dds41TDM(19), generic54016(20) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the device type for the trap." ::= { traplogEntry 7 } traplogDeleteEntry OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Writing the index of a trap to this object will delete the trap entry. Writing an index value of 0 will delete all entries." ::= { traplog 2 } traplogSortOption OBJECT-TYPE SYNTAX INTEGER { other(1), ascendingtimestamp(2), ascendingunit(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the order in which traps are presented." ::= { traplog 3 } traplogLastTimeStamp OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The timestamp of the newest trap in the trap log." ::= { traplog 4 } -- unitUtilities -- a table of unit utilities options unitUtilitiesTable OBJECT-TYPE SYNTAX SEQUENCE OF UnitUtilitiesTableEntry ACCESS not-accessible STATUS optional DESCRIPTION "The unit utilities table." ::= { unitUtilities 1 } unitUtilitiesTableEntry OBJECT-TYPE SYNTAX UnitUtilitiesTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the unit utilities table." INDEX { unitUtilitiesNearIndex, unitUtilitiesFarIndex } ::= { unitUtilitiesTable 1 } UnitUtilitiesTableEntry ::= SEQUENCE { unitUtilitiesNearIndex INTEGER, unitUtilitiesFarIndex INTEGER, unitUtilitiesLocalPassword DisplayString, unitUtilitiesTime DisplayString, unitUtilitiesDate DisplayString, unitUtilitiesMaintenanceReset INTEGER, unitUtilitiesAlarmResetTimer INTEGER, unitUtilitiesAlarmClear INTEGER } unitUtilitiesNearIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the near device." ::= { unitUtilitiesTableEntry 1 } unitUtilitiesFarIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Selects the far device." ::= { unitUtilitiesTableEntry 2 } unitUtilitiesLocalPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The password for local access to a device (VT100, front panel)." ::= { unitUtilitiesTableEntry 3 } unitUtilitiesTime OBJECT-TYPE SYNTAX DisplayString( SIZE(0..6) ) ACCESS read-write STATUS mandatory DESCRIPTION "This string is the current time as known to the device. The current time may be entered in this field using the HHMMSS format. For example, 3:45AM is entered as 034500 and 3:45PM is entered as 154500." ::= { unitUtilitiesTableEntry 4 } unitUtilitiesDate OBJECT-TYPE SYNTAX DisplayString( SIZE(0..6) ) ACCESS read-write STATUS mandatory DESCRIPTION "This string is the current date as known to the device. The current date may be entered in this field using the MMDDYY format. For example, July 4, 1997 is entered as 070497." ::= { unitUtilitiesTableEntry 5 } unitUtilitiesMaintenanceReset OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2), restart(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This field allows resetting the device to default values by reloading the start-up default configuration parameters." ::= { unitUtilitiesTableEntry 6 } unitUtilitiesAlarmResetTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS optional DESCRIPTION "This field allows setting a timer which will cause all existing alarms on the device to be cleared upon expiration. The counter is in seconds." ::= { unitUtilitiesTableEntry 7 } unitUtilitiesAlarmClear OBJECT-TYPE SYNTAX INTEGER { utilitiesAlarmClearOther(1), utilitiesAlarmClearNow(2) } ACCESS read-write STATUS optional DESCRIPTION "Writing a 2 to this field causes all existing alarms to be cleared immediatedly." ::= { unitUtilitiesTableEntry 8 } END