INTEL-SYS-MIB DEFINITIONS ::= BEGIN IMPORTS IpAddress FROM RFC1155-SMI products FROM Intel-Common-MIB DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212; snmp-agents OBJECT IDENTIFIER ::= { products 6 } agentConfiguration OBJECT IDENTIFIER ::= { snmp-agents 1 } agentVendorName OBJECT-TYPE SYNTAX DisplayString (SIZE (128)) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the SNMP agent's manufacturer name. " ::= { agentConfiguration 1 } agentProductName OBJECT-TYPE SYNTAX DisplayString (SIZE (128)) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the product name that contains the SNMP agent. " ::= { agentConfiguration 2 } agentChassisIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Displays which chassis contains the SNMP agent's module. " ::= { agentConfiguration 3 } agentModuleIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Displays which module in the chassis is the SNMP agent's module. The chassis number is in the object agentChassisIndex. " ::= { agentConfiguration 4 } mibversion OBJECT-TYPE SYNTAX DisplayString (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the version of the MIB supported by the SNMP agent. " ::= { agentConfiguration 5 } resetAgent OBJECT-TYPE SYNTAX INTEGER { reset(1), notreset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Performs a cold reset of the SNMP agent. If a new IP configuration was set, it will be used after the reset. " ::= { agentConfiguration 6 } ipConfiguration OBJECT IDENTIFIER ::= { snmp-agents 2 } ipAddressMethodInUse OBJECT-TYPE SYNTAX INTEGER { fixed(1), bootp(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays how the IP address in use was determined. For example, fixed means the IP address was assigned by the user and stored within the Management Module. BOOTP means the SNMP agent used a BOOTP server to get its IP configuration. " ::= { ipConfiguration 1 } ipAddressInUse OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Displays the IP address currently in use. " ::= { ipConfiguration 2 } gatewayorRouterAddrInUse OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Displays the default gateway address currently in use. This is the device that routes to a different network. Usually a router or a routing server. " ::= { ipConfiguration 3 } networkMaskInUse OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Displays the network (subnet) mask currently in use. This must match the masks of other devices on the same network. " ::= { ipConfiguration 4 } broadcastAddressInUse OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Displays the broadcast address currently in use. " ::= { ipConfiguration 5 } ipAddressMethodNextReset OBJECT-TYPE SYNTAX INTEGER { fixed(1), bootp(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Displays how the IP address will be determined after the SNMP agent is reset. For example, fixed means the IP address will be determined locally. BOOTP means the SNMP agent will search for a BOOTP server to get its IP configuration. " ::= { ipConfiguration 6 } ipAddressNextReset OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Displays the IP address the SNMP agent will use the next time it is reset. " ::= { ipConfiguration 7 } gatewayorRouterAddrNextReset OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Displays the default gateway the SNMP agent will use the next time it is reset. " ::= { ipConfiguration 8 } networkMaskNextReset OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Displays the netmask (subnet mask) the SNMP agent will use the next time it is reset. " ::= { ipConfiguration 9 } snmpConfiguration OBJECT IDENTIFIER ::= { snmp-agents 3 } snmpReadCommunityString OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS write-only STATUS mandatory DESCRIPTION "Sets the password for reads from the SNMP agent's MIB. " ::= { snmpConfiguration 1 } snmpWriteCommunityString OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS write-only STATUS mandatory DESCRIPTION "Sets the password for writes to the SNMP agent's MIB. " ::= { snmpConfiguration 2 } snmpTrapReceiverMAX OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Displays the maximum number of trap receiving stations. " ::= { snmpConfiguration 3 } snmpTrapReceiverNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Displays the current number of trap receiving stations. " ::= { snmpConfiguration 4 } snmpTrapAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpTrapAddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Contains information on individual trap receiving stations. " ::= { snmpConfiguration 5 } snmpTrapAddressEntry OBJECT-TYPE SYNTAX SnmpTrapAddressEntry ACCESS not-accessible STATUS mandatory INDEX { trapAddrIndex } ::= { snmpTrapAddressTable 1 } SnmpTrapAddressEntry ::= SEQUENCE { trapAddrIndex INTEGER, trapIPAddr IpAddress, trapCommunityString DisplayString, trapStatus INTEGER } trapAddrIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Displays the index number of the trap receiving station. " ::= { snmpTrapAddressEntry 1 } trapIPAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Sets the IP address for a trap receiving station. " ::= { snmpTrapAddressEntry 2 } trapCommunityString OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Sets the password for sending traps from the SNMP agent to the SNMP application on the trap receiving station. " ::= { snmpTrapAddressEntry 3 } trapStatus OBJECT-TYPE SYNTAX INTEGER { active(1), ignore(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Displays whether traps should be sent to this station (active) or whether traps should not be sent to this station (ignore). " ::= { snmpTrapAddressEntry 4 } END