INTEL-ES480-TRAP-MIB DEFINITIONS ::= BEGIN IMPORTS intel FROM INTEL-ES480-MIB sysUpTime, sysDescr, ifPhysAddress FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215; overheat TRAP-TYPE ENTERPRISE intel VARIABLES { sysUpTime, sysDescr } DESCRIPTION "A overheat trap indicates that the on board tempature sensor has reported a overheat condition. System will shutdown until unit has sufficiently cooled such that operation may begin again. A cold start trap will be issued when the unit has come back on line." ::= 1 fanfailed TRAP-TYPE ENTERPRISE intel VARIABLES { sysUpTime, sysDescr } DESCRIPTION "A fan failed trap indicates one or more of the cooling fans inside the device has failed. A fanOK trap will be sent once the fan has attained normal operation." ::= 2 fanOK TRAP-TYPE ENTERPRISE intel VARIABLES { sysUpTime, sysDescr } DESCRIPTION "A fan has transitioned out of a failure state and is now operating correctly." ::= 3 invalidLoginAttempt TRAP-TYPE ENTERPRISE intel VARIABLES { sysUpTime, sysDescr } DESCRIPTION "A user attempted to login to console or by telnet but was refused access due to incorrect username or password" ::= 4 powerSupplyFail TRAP-TYPE ENTERPRISE intel VARIABLES { sysUpTime, sysDescr } DESCRIPTION "One or more sources of power to this agent has failed. Presumably a redundant power-supply has taken over." ::= 5 powerSupplyGood TRAP-TYPE ENTERPRISE intel VARIABLES { sysUpTime, sysDescr } DESCRIPTION "One or more previously bad sources of power to this agent has come back to life without causing an agent restart." ::= 6 END