--****************************************************************** --* --* Copyright (c) 1993, 1999 by 3Com Corporation --* All Rights Reserved --* --* $Revision: 7.1 $ --* $Date: Aug 06 1999 17:30:04 $ --* --* 3COM IDT1 MIB --* --****************************************************************** IDT1-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, experimental, IpAddress, TimeTicks, Gauge, Counter FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212; usr OBJECT IDENTIFIER ::= { enterprises 429 } nas OBJECT IDENTIFIER ::= { usr 1 } idt1 OBJECT IDENTIFIER ::= { nas 15 } -- The T1-PRI ISDN Card Configuration Group. idt1Cfg OBJECT IDENTIFIER ::= { idt1 1 } idt1CfgTable OBJECT-TYPE SYNTAX SEQUENCE OF Idt1CfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each of the manageable T1-PRI ISDN Cards in the chassis. It contains objects that reflect the current configuration of parameters that affect the operation of all the entities that reside on the given card." ::= { idt1Cfg 1 } idt1CfgEntry OBJECT-TYPE SYNTAX Idt1CfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There is one Configuration table entry per T1-PRI ISDN Card in the chassis." INDEX { idt1CfgIndex } ::= { idt1CfgTable 1 } Idt1CfgEntry ::= SEQUENCE { idt1CfgIndex INTEGER, idt1CfgAssgndISDNGateway INTEGER, idt1CfgMdmCallsAllowedEna INTEGER, idt1CfgMdmRoutingMethod INTEGER, idt1CfgProjectSelectionR2 INTEGER, idt1CfgInfoMsgTimeOut INTEGER, idt1CfgInbDNISLength INTEGER, idt1CfgSelectCompanding INTEGER, idt1CfgAniNumberEnable INTEGER, idt1CfgNoBptyMethod INTEGER, idt1CfgMaxISDNGwyCalls INTEGER } idt1CfgIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each card in the chassis. The value of idt1CfgIndex matches the value of the index for the corresponding card entity in the entity table of the chassis MIB." ::= { idt1CfgEntry 1 } idt1CfgAssgndISDNGateway OBJECT-TYPE SYNTAX INTEGER (0..16) ACCESS read-write STATUS mandatory DESCRIPTION "Identifies the NAS chassis slot of the Gateway Card assigned to this T1-PRI ISDN card. Range 0-16. Default=0(none)." ::= { idt1CfgEntry 2 } idt1CfgMdmCallsAllowedEna OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates if modem calls are disabled/enabled for this T1-PRI ISDN Card. Default = enable(1)." ::= { idt1CfgEntry 3 } idt1CfgMdmRoutingMethod OBJECT-TYPE SYNTAX INTEGER{ notSupported(1), roundRobin(2), firstAvailable(3), fixedAssignment(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines the mechanism used for modem call routing for this T1-PRI ISDN Card. Default = roundRobin(2)." ::= { idt1CfgEntry 4 } idt1CfgProjectSelectionR2 OBJECT-TYPE SYNTAX INTEGER{ q421(1), r2(2), r2Korea(3), p7(4), r2Malaysia(5), r2Brazil(6), r2Mexico(7), r2China(8), r2LME(9), r2Venezuela(10), notApplicable(255) } ACCESS read-write STATUS mandatory DESCRIPTION "This object lets user select E1 CAS project options. Default = mfcBkR2(3)." ::= { idt1CfgEntry 5 } idt1CfgInfoMsgTimeOut OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the time out delay in seconds between INFO messages. This parameter is effective if overlap rx mode is enabled. Default = 12 " ::= { idt1CfgEntry 6 } idt1CfgInbDNISLength OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-write STATUS mandatory DESCRIPTION "This objects sets the total number of digits expected in the inbound phone number. In the E1-PRI this only is effective when overlap rx mode is enabled. Default = 15" ::= { idt1CfgEntry 7 } idt1CfgSelectCompanding OBJECT-TYPE SYNTAX INTEGER{ alaw(1), ulaw(2), useCountryCode(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Select companding (alaw or ulaw) for use with PCM encoded data. Default = alaw(1)." ::= { idt1CfgEntry 8 } idt1CfgAniNumberEnable OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Allow the collection of A calling party phone number. This takes additional time, and is not allowed for all switches. Default = disable(2)." ::= { idt1CfgEntry 9 } idt1CfgNoBptyMethod OBJECT-TYPE SYNTAX INTEGER{ analog(1), digital(2), unAllocatedNum(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the method for handling an incoming call when the B-party (Called Number) is not found within the table." ::= { idt1CfgEntry 10 } idt1CfgMaxISDNGwyCalls OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object sets the maximum number of ISDN calls that can be terminated by the Gateway card. Default = 0." ::= { idt1CfgEntry 11 } -- The T1-PRI ISDN Card Call Routing Group. idt1Cr OBJECT IDENTIFIER ::= { idt1 2 } idt1CrTable OBJECT-TYPE SYNTAX SEQUENCE OF Idt1CrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each of the manageable T1-PRI ISDN Cards in the chassis. It contains objects that reflect the current call routing configuration of the card." ::= { idt1Cr 1 } idt1CrEntry OBJECT-TYPE SYNTAX Idt1CrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There is one Call Routing Table entry per T1-PRI ISDN Card in the chassis." INDEX { idt1CrIndex, idt1CrPhNumIndex } ::= { idt1CrTable 1 } Idt1CrEntry ::= SEQUENCE { idt1CrIndex INTEGER, idt1CrPhNumIndex INTEGER, idt1CrInboundPhNum DisplayString, idt1CrInboundCallType INTEGER } idt1CrIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each card in the chassis. The value of idt1CrIndex matches the value of the index for the corresponding card's entry in the entity table of the chassis MIB." ::= { idt1CrEntry 1 } idt1CrPhNumIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object is the index for one of the 48 inbound call routing objects for this card." ::= { idt1CrEntry 2 } idt1CrInboundPhNum OBJECT-TYPE SYNTAX DisplayString (SIZE(0..36)) ACCESS read-write STATUS mandatory DESCRIPTION "This is one of the 48 inbound call routing phone numbers." ::= { idt1CrEntry 3 } idt1CrInboundCallType OBJECT-TYPE SYNTAX INTEGER{ analog(1), digital(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This is one of the 48 inbound call routing call types. Default = analog(1)." ::= { idt1CrEntry 4 } -- The T1-PRI ISDN Reserved Resource Pool to DNIS Mapping table. idt1Pl OBJECT IDENTIFIER ::= { idt1 3 } idt1PlTable OBJECT-TYPE SYNTAX SEQUENCE OF Idt1PlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each of the manageable T1-PRI ISDN Cards in the chassis. It contains objects that reflect the current reserved resource pool to DNIS mapping." ::= { idt1Pl 1 } idt1PlEntry OBJECT-TYPE SYNTAX Idt1PlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There is one Reserved Resuorce Pool ID to DNIS Mapping Table entry per T1-PRI ISDN Card in the chassis." INDEX { idt1PlIndex, idt1PlIDIndex } ::= { idt1PlTable 1 } Idt1PlEntry ::= SEQUENCE { idt1PlIndex INTEGER, idt1PlIDIndex INTEGER, idt1PlDNIS DisplayString, idt1PlType INTEGER } idt1PlIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each card in the chassis. The value of idt1PlIndex matches the value of the index for the corresponding card's entry in the entity table of the chassis MIB." ::= { idt1PlEntry 1 } idt1PlIDIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object is the index for one of the 12 pool IDs for this card." ::= { idt1PlEntry 2 } idt1PlDNIS OBJECT-TYPE SYNTAX DisplayString (SIZE(0..36)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the DNIS number associated with the POOL ID." ::= { idt1PlEntry 3 } idt1PlType OBJECT-TYPE SYNTAX INTEGER{ none(1), analog(2), digital(3), both(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is the pool type associated with the pool ID." ::= { idt1PlEntry 4 } -- The T1-PRI ISDN Reserved Resource Pool Assignment table. idt1MdmRPA OBJECT IDENTIFIER ::= { idt1 4 } idt1MdmRPATable OBJECT-TYPE SYNTAX SEQUENCE OF Idt1MdmRPAEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each of the manageable T1-PRI ISDN Cards in the chassis. It contains objects that reflect the current Pool Assignment of the Pool Id to the modem device." ::= { idt1MdmRPA 1 } idt1MdmRPAEntry OBJECT-TYPE SYNTAX Idt1MdmRPAEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There is one Reserved Pool Assignment to modem device Table entry per T1-PRI ISDN Card in the chassis." INDEX { idt1MdmRPAIndex, idt1MdmRPAIDIndex } ::= { idt1MdmRPATable 1 } Idt1MdmRPAEntry ::= SEQUENCE { idt1MdmRPAIndex INTEGER, idt1MdmRPAIDIndex INTEGER, idt1MdmRPASlot INTEGER, idt1MdmRPAChan INTEGER, idt1MdmRPAPoolID INTEGER } idt1MdmRPAIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each card in the chassis. The value of idt1MdmRPA Index matches the value of the index for the corresponding card's entry in the entity table of the chassis MIB." ::= { idt1MdmRPAEntry 1 } idt1MdmRPAIDIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object is the index for one of the 64 channel IDs for this card." ::= { idt1MdmRPAEntry 2 } idt1MdmRPASlot OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "The channel associated with the Id of Modem device Reserved resource Pool Assignment table." ::= { idt1MdmRPAEntry 3 } idt1MdmRPAChan OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "The slot associated with the Id of Modem device Reserved resource Pool Assignment table." ::= { idt1MdmRPAEntry 4 } idt1MdmRPAPoolID OBJECT-TYPE SYNTAX INTEGER (0..12) ACCESS read-write STATUS mandatory DESCRIPTION "The Pool Id assigned in the Modem device Reserved resource Pool Assignment table (1/2/3/4 <-> none/A/B/C/D)." ::= { idt1MdmRPAEntry 5 } -- The T1-PRI ISDN-Gateway to Reserved Resource Pool Assignment table. idt1GwyRPA OBJECT IDENTIFIER ::= { idt1 5 } idt1GwyRPATable OBJECT-TYPE SYNTAX SEQUENCE OF Idt1GwyRPAEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains an entry for each of the manageable T1-PRI ISDN Cards in the chassis. It contains objects that reflect the current Pool Assignment of the Pool Id to the ISDN-Gateway(s)." ::= { idt1GwyRPA 1 } idt1GwyRPAEntry OBJECT-TYPE SYNTAX Idt1GwyRPAEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There is one Reserved Pool Assignment to slot device Table entry per T1-PRI ISDN Card in the chassis." INDEX { idt1GwyRPAIndex, idt1GwyRPASlotIndex } ::= { idt1GwyRPATable 1 } Idt1GwyRPAEntry ::= SEQUENCE { idt1GwyRPAIndex INTEGER, idt1GwyRPASlotIndex INTEGER, idt1GwyRPAPoolID INTEGER } idt1GwyRPAIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each card in the chassis. The value of idt1GwyRPA Index matches the value of the index for the corresponding card's entry in the entity table of the chassis MIB." ::= { idt1GwyRPAEntry 1 } idt1GwyRPASlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object is the index for one of the 16 Slots in the chassis." ::= { idt1GwyRPAEntry 2 } idt1GwyRPAPoolID OBJECT-TYPE SYNTAX INTEGER (0..12) ACCESS read-write STATUS mandatory DESCRIPTION "The Pool Id assigned in the ISDN-Gateway device Reserved resource Pool Assignment table (1/2/3/4 <-> none/A/B/C/D)." ::= { idt1GwyRPAEntry 3 } END