-- ------------------------------------------------------------------ -- Description HWMUSA-SHDSL-CPE-MIB -- Author -- Create Date 2002-04 -- Modify Date 2002-07-20 -- Version 1.02 -- Copyright 1985 - 2004 HuaWei Tech, Inc. -- ALL RIGHTS RESERVED -- ------------------------------------------------------------------ HWMUSA-SHDSL-CPE-MIB DEFINITIONS ::= BEGIN IMPORTS hwProducts FROM HUAWEI-MIB ifIndex FROM IF-MIB DisplayString FROM RFC1213-MIB IpAddress, Unsigned32, Gauge32, OBJECT-TYPE FROM SNMPv2-SMI TruthValue FROM SNMPv2-TC; musa OBJECT IDENTIFIER ::= { hwProducts 6 } ias OBJECT IDENTIFIER ::= { musa 7 } hwIasService OBJECT IDENTIFIER ::= { ias 4 } hwMusaShdsl OBJECT IDENTIFIER ::= { hwIasService 4 } hwShdslCPE OBJECT IDENTIFIER ::= { hwMusaShdsl 2 } hwShdslCPECommon OBJECT IDENTIFIER ::= { hwShdslCPE 1 } umCommonInventoryTable OBJECT-TYPE SYNTAX SEQUENCE OF UmCommonInventoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing common inventory information." ::= { hwShdslCPECommon 1 } umCommonInventoryEntry OBJECT-TYPE SYNTAX UmCommonInventoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in umCommonInventoryTable." INDEX { ifIndex } ::= { umCommonInventoryTable 1 } UmCommonInventoryEntry ::= SEQUENCE { umCommonInventoryModel INTEGER, umCommonInventorySwVer DisplayString, umCommonInventoryHwVer DisplayString, umCommonInventoryDevName DisplayString } umCommonInventoryModel OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " This variable indicates the model number. " ::= { umCommonInventoryEntry 1 } umCommonInventorySwVer OBJECT-TYPE SYNTAX DisplayString (SIZE (5)) MAX-ACCESS read-only STATUS current DESCRIPTION " This variable indicates the software version. format: a.bcd (a, b, c, d: 0 ~ 9) " ::= { umCommonInventoryEntry 2 } umCommonInventoryHwVer OBJECT-TYPE SYNTAX DisplayString (SIZE (5)) MAX-ACCESS read-only STATUS current DESCRIPTION " This variable indicates the hardware version. format: a.bcd (a, b, c, d: 0 ~ 9) " ::= { umCommonInventoryEntry 3 } umCommonInventoryDevName OBJECT-TYPE SYNTAX DisplayString (SIZE (8)) MAX-ACCESS read-write STATUS current DESCRIPTION " This variable indicates the device name. " ::= { umCommonInventoryEntry 4 } umCommonConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF UmCommonConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing common config information." ::= { hwShdslCPECommon 2 } umCommonConfigEntry OBJECT-TYPE SYNTAX UmCommonConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in umCommonConfigTable." INDEX { ifIndex } ::= { umCommonConfigTable 1 } UmCommonConfigEntry ::= SEQUENCE { umCommonConfigDate DisplayString, umCommonConfigTime DisplayString } umCommonConfigDate OBJECT-TYPE SYNTAX DisplayString (SIZE (10)) MAX-ACCESS read-write STATUS current DESCRIPTION " This variable is used to define date information of the device. The format is MM/DD/YYYY. MM means month, DD is day, and YYYY stands for year. The range is from 01/01/1990 to 12/31/2100. " ::= { umCommonConfigEntry 1 } umCommonConfigTime OBJECT-TYPE SYNTAX DisplayString (SIZE (8)) MAX-ACCESS read-write STATUS current DESCRIPTION " This variable is used to define time information of the device. The format is HH:MM:SS. HH means hour, MM is to indicate minute and SS is for second. " ::= { umCommonConfigEntry 2 } umCommonActionTable OBJECT-TYPE SYNTAX SEQUENCE OF UmCommonActionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing actions to CPE." ::= { hwShdslCPECommon 3 } umCommonActionEntry OBJECT-TYPE SYNTAX UmCommonActionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in umCommonActionTable." INDEX { ifIndex } ::= { umCommonActionTable 1 } UmCommonActionEntry ::= SEQUENCE { umCommonActionDbSave INTEGER, umCommonActionWarmStart INTEGER } umCommonActionDbSave OBJECT-TYPE SYNTAX INTEGER { save(1) } MAX-ACCESS read-write STATUS current DESCRIPTION " This variable is to initiate the VCDB command. 1: save " ::= { umCommonActionEntry 1 } umCommonActionWarmStart OBJECT-TYPE SYNTAX INTEGER { restart(1) } MAX-ACCESS read-write STATUS current DESCRIPTION " This value is to restart the device. TRUE (1): warm start " ::= { umCommonActionEntry 2 } umCommonSnmpConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF UmCommonSnmpConfigEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A table containing SNMP configuration information." ::= { hwShdslCPECommon 4 } umCommonSnmpConfigEntry OBJECT-TYPE SYNTAX UmCommonSnmpConfigEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "An entry in umCommonSnmpConfigTable." INDEX { ifIndex } ::= { umCommonSnmpConfigTable 1 } UmCommonSnmpConfigEntry ::= SEQUENCE { umCommonSnmpConfigIpAddress IpAddress, umCommonSnmpConfigIpSubnetMask IpAddress, umCommonSnmpConfigIpGatewayIp IpAddress, umCommonSnmpConfigTrapIpAddress1 IpAddress, umCommonSnmpConfigTrapIpPortNum1 INTEGER, umCommonSnmpConfigTrapIpAddress2 IpAddress, umCommonSnmpConfigTrapIpPortNum2 INTEGER } umCommonSnmpConfigIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS deprecated DESCRIPTION " This variable is to indicate IP address of the device. " ::= { umCommonSnmpConfigEntry 1 } umCommonSnmpConfigIpSubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS deprecated DESCRIPTION " This variable is to define the subnet mask of the IP address of the device. " ::= { umCommonSnmpConfigEntry 2 } umCommonSnmpConfigIpGatewayIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS deprecated DESCRIPTION " This variable is to define the gateway IP address of the device. " ::= { umCommonSnmpConfigEntry 3 } umCommonSnmpConfigTrapIpAddress1 OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS deprecated DESCRIPTION " This variable is to define the IP address where the manager receives trap. " ::= { umCommonSnmpConfigEntry 4 } umCommonSnmpConfigTrapIpPortNum1 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS deprecated DESCRIPTION " This variable is to define the UDP port number where the manager receives trap. The possible values are: 162 (default) 62000 62001 62002 " ::= { umCommonSnmpConfigEntry 5 } umCommonSnmpConfigTrapIpAddress2 OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS deprecated DESCRIPTION " This variable is to define the IP address where the manager receives trap. " ::= { umCommonSnmpConfigEntry 6 } umCommonSnmpConfigTrapIpPortNum2 OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS deprecated DESCRIPTION " This variable is to define the UDP port number where the manager receives trap. The possible values are: 162 (default) 62000 62001 62002 " ::= { umCommonSnmpConfigEntry 7 } hwShdslCPESdsl OBJECT IDENTIFIER ::= { hwShdslCPE 2 } umSdslConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF UmSdslConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing Sdsl configuration information." ::= { hwShdslCPESdsl 1 } umSdslConfigEntry OBJECT-TYPE SYNTAX UmSdslConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in umSdslConfigTable." INDEX { ifIndex } ::= { umSdslConfigTable 1 } UmSdslConfigEntry ::= SEQUENCE { umSdslConfigNEType INTEGER, umSdslConfigRateAdaptive INTEGER, umSdslConfigDataRate INTEGER, umSdslResetPerformance INTEGER, umSdslTimeElapsed INTEGER, umSdslValidIntervals INTEGER } umSdslConfigNEType OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS deprecated DESCRIPTION " This variable is to set this STU-C or STU-R configuration. (0): STU-C (LT mode) (1): STU-R (NT mode) " ::= { umSdslConfigEntry 1 } umSdslConfigRateAdaptive OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " This variable is to enable/disable the rate adaptive configuration. (0): Fixed (1): Adaptive " ::= { umSdslConfigEntry 2 } umSdslConfigDataRate OBJECT-TYPE SYNTAX INTEGER (3..32) MAX-ACCESS read-only STATUS current DESCRIPTION " This variable is to set data rate (N*64k) of Sdsl. If Rate Adaptive is TRUE, the value is invalid till Rate Adaptive is FALSE. " ::= { umSdslConfigEntry 3 } umSdslResetPerformance OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " This value is to reset performance register. 1: reset all current performance data 2: reset current ES 3: reset current SES 4: reset current UAS 5: reset all history performance data 6: reset history ES 7: reset history SES 8: reset history UAS " ::= { umSdslConfigEntry 4 } umSdslTimeElapsed OBJECT-TYPE SYNTAX INTEGER (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION " The number of seconds that have elapsed since the beginning of the current error-measurement period." ::= { umSdslConfigEntry 5 } umSdslValidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION " The number of previous intervals for which valid data was collected. The value will be 96 unless the interface was brought on-line within the last 24 hours, in which case the value will be the number of complete 15 minute intervals the since interface has been online. " ::= { umSdslConfigEntry 6 } umSdslThresholdTable OBJECT-TYPE SYNTAX SEQUENCE OF UmSdslThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing MSDSL configuration information." ::= { hwShdslCPESdsl 2 } umSdslThresholdEntry OBJECT-TYPE SYNTAX UmSdslThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in umSdslThresholdTable." INDEX { ifIndex } ::= { umSdslThresholdTable 1 } UmSdslThresholdEntry ::= SEQUENCE { umSdslThreshold15mES Gauge32, umSdslThreshold15mSES Gauge32, umSdslThreshold15mUAS Gauge32, umSdslThreshold24hES Gauge32, umSdslThreshold24hSES Gauge32, umSdslThreshold24hUAS Gauge32, umSdslThresholdSNRMargin Gauge32, umSdslThresholdLoopAttenuation Gauge32 } umSdslThreshold15mES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the 15-minute threshold of ES. " ::= { umSdslThresholdEntry 1 } umSdslThreshold15mSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the 15-minute threshold of SES. " ::= { umSdslThresholdEntry 2 } umSdslThreshold15mUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the 15-minute threshold of UAS. " ::= { umSdslThresholdEntry 3 } umSdslThreshold24hES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the 24-hour threshold of ES. " ::= { umSdslThresholdEntry 4 } umSdslThreshold24hSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the 24-hour threshold of SES. " ::= { umSdslThresholdEntry 5 } umSdslThreshold24hUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the 24-hour threshold of UAS. " ::= { umSdslThresholdEntry 6 } umSdslThresholdSNRMargin OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION " This variable indicates the SNR margin threshold of the Sdsl line. 1~15: valid value " ::= { umSdslThresholdEntry 7 } umSdslThresholdLoopAttenuation OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION " This variable indicates the Loop Attenuation threshold of the Sdsl line. 1~127: " ::= { umSdslThresholdEntry 8 } umSdslPmCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF UmSdslPmCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Sdsl PM Current table." ::= { hwShdslCPESdsl 3 } umSdslPmCurrentEntry OBJECT-TYPE SYNTAX UmSdslPmCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Sdsl Pm Current table." INDEX { ifIndex } ::= { umSdslPmCurrentTable 1 } UmSdslPmCurrentEntry ::= SEQUENCE { umSdslPmCurrentES Gauge32, umSdslPmCurrentSES Gauge32, umSdslPmCurrentUAS Gauge32 } umSdslPmCurrentES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds encountered by an Sdsl during the current interval." ::= { umSdslPmCurrentEntry 1 } umSdslPmCurrentSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Seconds encountered by an Sdsl during the current interval." ::= { umSdslPmCurrentEntry 2 } umSdslPmCurrentUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds encountered by an Sdsl during the current interval." ::= { umSdslPmCurrentEntry 3 } umSdslPmIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF UmSdslPmIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Sdsl Interval table." ::= { hwShdslCPESdsl 4 } umSdslPmIntervalEntry OBJECT-TYPE SYNTAX UmSdslPmIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Sdsl Interval table." INDEX { ifIndex, umSdslPmIntervalIndex } ::= { umSdslPmIntervalTable 1 } UmSdslPmIntervalEntry ::= SEQUENCE { umSdslPmIntervalIndex INTEGER, umSdslPmIntervalES Gauge32, umSdslPmIntervalSES Gauge32, umSdslPmIntervalUAS Gauge32 } umSdslPmIntervalIndex OBJECT-TYPE SYNTAX INTEGER (1..96) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval. " ::= { umSdslPmIntervalEntry 1 } umSdslPmIntervalES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds encountered by an Sdsl in one interval." ::= { umSdslPmIntervalEntry 2 } umSdslPmIntervalSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Seconds encountered by an Sdsl in one interval." ::= { umSdslPmIntervalEntry 3 } umSdslPmIntervalUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds encountered by an Sdsl in one interval." ::= { umSdslPmIntervalEntry 4 } umSdslPmCurrentDayTable OBJECT-TYPE SYNTAX SEQUENCE OF UmSdslPmCurrentDayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Sdsl PM Current Day table. (0:00AM ~ the last completed quarter)" ::= { hwShdslCPESdsl 5 } umSdslPmCurrentDayEntry OBJECT-TYPE SYNTAX UmSdslPmCurrentDayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Sdsl Pm Current Day table." INDEX { ifIndex } ::= { umSdslPmCurrentDayTable 1 } UmSdslPmCurrentDayEntry ::= SEQUENCE { umSdslPmCurrentDayES Gauge32, umSdslPmCurrentDaySES Gauge32, umSdslPmCurrentDayUAS Gauge32 } umSdslPmCurrentDayES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds encountered by an Sdsl during the Current Day." ::= { umSdslPmCurrentDayEntry 1 } umSdslPmCurrentDaySES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Seconds encountered by an Sdsl during the Current Day." ::= { umSdslPmCurrentDayEntry 2 } umSdslPmCurrentDayUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds encountered by an Sdsl during the Current Day." ::= { umSdslPmCurrentDayEntry 3 } umSdslPmDayTable OBJECT-TYPE SYNTAX SEQUENCE OF UmSdslPmDayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SDSL Pm Day table." ::= { hwShdslCPESdsl 6 } umSdslPmDayEntry OBJECT-TYPE SYNTAX UmSdslPmDayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Sdsl Pm Day table." INDEX { ifIndex, umSdslPmDayIndex } ::= { umSdslPmDayTable 1 } UmSdslPmDayEntry ::= SEQUENCE { umSdslPmDayIndex INTEGER, umSdslPmDayES Gauge32, umSdslPmDaySES Gauge32, umSdslPmDayUAS Gauge32 } umSdslPmDayIndex OBJECT-TYPE SYNTAX INTEGER (1..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A number between 1 and 7, where 1 is the most recently completed day and 7 is the least recently completed day. " ::= { umSdslPmDayEntry 1 } umSdslPmDayES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds encountered by an Sdsl in one day. " ::= { umSdslPmDayEntry 2 } umSdslPmDaySES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Seconds encountered by an Sdsl in one day." ::= { umSdslPmDayEntry 3 } umSdslPmDayUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds encountered by an Sdsl in one day." ::= { umSdslPmDayEntry 4 } umSdslTestTable OBJECT-TYPE SYNTAX SEQUENCE OF UmSdslTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing SHDSL testing function." ::= { hwShdslCPESdsl 7 } umSdslTestEntry OBJECT-TYPE SYNTAX UmSdslTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in umSdslTestTable." INDEX { ifIndex } ::= { umSdslTestTable 1 } UmSdslTestEntry ::= SEQUENCE { umSdslTestLoopback INTEGER, umSdslTestPattern INTEGER, umSdslTestPeriod INTEGER, umSdslTestStart TruthValue, umSdslTestInsertOneBitError TruthValue, umSdslTestElapsedTime INTEGER, umSdslTestErrCount DisplayString, umSdslTestErrRate DisplayString } umSdslTestLoopback OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " This value is to set loopback. 0: Release 2: Loopback toward Network " ::= { umSdslTestEntry 1 } umSdslTestPattern OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " This variable is used to set test pattern. 1: 511 2: 2047 3: PRBS Support Eoc Version 1.02 (23/04/2002) " ::= { umSdslTestEntry 2 } umSdslTestPeriod OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " This variable is used to get/set test period in second. A value of 0 means non-stop testing. " ::= { umSdslTestEntry 3 } umSdslTestStart OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION " This value is to start or stop testing(only local). TRUE (1): Start FALSE (2): Stop " ::= { umSdslTestEntry 4 } umSdslTestInsertOneBitError OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION " This variable is used to initiate pause test pattern. This is used in error insertion application. (1) Insert error rate(rate= 10E-1) " ::= { umSdslTestEntry 5 } umSdslTestElapsedTime OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " This variable is to indicate elapsed time of testing in second." ::= { umSdslTestEntry 6 } umSdslTestErrCount OBJECT-TYPE SYNTAX DisplayString (SIZE (1..11)) MAX-ACCESS read-only STATUS current DESCRIPTION " This variable is to indicate error count of testing. " ::= { umSdslTestEntry 7 } umSdslTestErrRate OBJECT-TYPE SYNTAX DisplayString (SIZE (12)) MAX-ACCESS read-only STATUS current DESCRIPTION " This variable is to indicate error rate of testing, which is 'a.bcx10E(-d)', a, b, c: 0..9, d: 1..9." ::= { umSdslTestEntry 8 } hwShdslCPEV35 OBJECT IDENTIFIER ::= { hwShdslCPE 3 } umSdslV35ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF UmSdslV35ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The config table contains Ne config items. " ::= { hwShdslCPEV35 1 } umSdslV35ConfigEntry OBJECT-TYPE SYNTAX UmSdslV35ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the config table " INDEX { ifIndex } ::= { umSdslV35ConfigTable 1 } UmSdslV35ConfigEntry ::= SEQUENCE { umSdslV35ConfigCurrentDataRate INTEGER, umSdslV35ConfigCurrentTimingSrc INTEGER, umSdslV35ConfigTimingSrc INTEGER } umSdslV35ConfigCurrentDataRate OBJECT-TYPE SYNTAX INTEGER (3..32) MAX-ACCESS read-only STATUS current DESCRIPTION " This variable is to get current data rate (N*64k) of Sdsl V35. " ::= { umSdslV35ConfigEntry 1 } umSdslV35ConfigCurrentTimingSrc OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS deprecated DESCRIPTION " This variable is to get the current timing source of the system. 0: internal 1: from loop (SDSL) 2: from DTE (V.35) " ::= { umSdslV35ConfigEntry 2 } umSdslV35ConfigTimingSrc OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS deprecated DESCRIPTION " This variable is to get/set the setted timing source of the system. 0: internal 1: from loop (SDSL) 2: from DTE (V.35) " ::= { umSdslV35ConfigEntry 3 } umSdslV35DTETable OBJECT-TYPE SYNTAX SEQUENCE OF UmSdslV35DTEEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The alarm table contains DTE. " ::= { hwShdslCPEV35 2 } umSdslV35DTEEntry OBJECT-TYPE SYNTAX UmSdslV35DTEEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the alarm table " INDEX { ifIndex } ::= { umSdslV35DTETable 1 } UmSdslV35DTEEntry ::= SEQUENCE { umSdslV35DTEStatus INTEGER, umSdslV35DTERTS INTEGER, umSdslV35TailFunc INTEGER } umSdslV35DTEStatus OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " The variable represents which port reports the DTE Status. (bit) 0 : RTS 1 : CTS 2 : DCD 3 : DSR " ::= { umSdslV35DTEEntry 1 } umSdslV35DTERTS OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " The variable represents which port reports the RTS Config Status. 0 : RTS from DTE 1 : RTS Permanent On " ::= { umSdslV35DTEEntry 2 } umSdslV35TailFunc OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " The variable represents tail function switch. 0 : Tail off 1 : Tail on " ::= { umSdslV35DTEEntry 3 } umSdslV35LoopbackTable OBJECT-TYPE SYNTAX SEQUENCE OF UmSdslV35LoopbackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The V35 Loopback Table." ::= { hwShdslCPEV35 3 } umSdslV35LoopbackEntry OBJECT-TYPE SYNTAX UmSdslV35LoopbackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the Sdsl Testing table." INDEX { ifIndex } ::= { umSdslV35LoopbackTable 1 } UmSdslV35LoopbackEntry ::= SEQUENCE { umSdslV35Loopback INTEGER } umSdslV35Loopback OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " This value is to set loopback. 0: Release 1: Toward DTE Loop 2: Toward Network Loop 3: Initial in-band Loop (V.54) " ::= { umSdslV35LoopbackEntry 1 } umSdslV35AlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF UmSdslV35AlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The alarm table contains alarm event history. " ::= { hwShdslCPEV35 4 } umSdslV35AlarmEntry OBJECT-TYPE SYNTAX UmSdslV35AlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the alarm table " INDEX { ifIndex } ::= { umSdslV35AlarmTable 1 } UmSdslV35AlarmEntry ::= SEQUENCE { umSdslV35ClearAlarmHistory TruthValue, umSdslV35AlarmStatus INTEGER } umSdslV35ClearAlarmHistory OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION " The variable initiate the clear alarm history action(Set 1). " ::= { umSdslV35AlarmEntry 1 } umSdslV35AlarmStatus OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " The variable initiate the current alarm status. (bit) bit0: Loss of SDSL synchronization word (LOSW) bit1: (SDSL) ES exceed day threshold bit2: (SDSL) ES exceed quarter threshold bit3: (SDSL) SES exceed day threshold bit4: (SDSL) SES exceed quarter threshold bit5: (SDSL) UAS exceed day threshold bit6: (SDSL) UAS exceed quarter threshold bit7: (SDSL) SNR exceed threshold bit8: (SDSL) Loop Attuattion exceed threshold bit9~31: Reserved DataType = 72 " ::= { umSdslV35AlarmEntry 2 } hwCPET1E1 OBJECT IDENTIFIER ::= { hwShdslCPE 4 } umLiuTable OBJECT-TYPE SYNTAX SEQUENCE OF UMLiuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The LIU table. The LIU attributes regarding configuration and performance are defined in RFC1406." ::= { hwCPET1E1 1 } umLiuEntry OBJECT-TYPE SYNTAX UMLiuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the LIU table." INDEX { ifIndex } ::= { umLiuTable 1 } UMLiuEntry ::= SEQUENCE { umLiuE1Transparent INTEGER, umLiuLineDrive INTEGER, umLiuIdleCodeword INTEGER, umLiuE1SlotMap INTEGER, umLiuResetPerformance INTEGER } umLiuE1Transparent OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " This value gets/sets the E1 Transparency. Disable(0), Enable (1) " ::= { umLiuEntry 1 } umLiuLineDrive OBJECT-TYPE SYNTAX INTEGER { drive-75-Ohm(0), drive-120-Ohm(1) } MAX-ACCESS read-write STATUS current DESCRIPTION " This variable is to define the value of line drive. 75_Ohm(0), 120_Ohm(1) " ::= { umLiuEntry 2 } umLiuIdleCodeword OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION " This variable represents the value of idle code word. But the write-operation is preserved for future use. If you take write-operation, will be returned. " ::= { umLiuEntry 3 } umLiuE1SlotMap OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " This table defines the corresponding customer equipment interface for each time slot of network interface. Each bit represents one time slot. '1' stands for occupied. The leftmost bit represents time slot 31, and rightmost bit represents time slot 0. " ::= { umLiuEntry 4 } umLiuResetPerformance OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " This value is to reset performance register for this port. 1: reset all current performance data 2: reset current LCV 3: reset current PCV 4: reset current ES 5: reset current SES 6: reset current SEFS 7: reset current UAS 8: reset current CSS 9: reset current DM 10: reset current CS 11: reset current FBE 51: reset all history performance data 52: reset history LCV 53: reset history PCV 54: reset history ES 55: reset history SES 56: reset history SEFS 57: reset history UAS 58: reset history CSS 59: reset history DM 60: reset history CS 61: reset history FBE " ::= { umLiuEntry 5 } umLiuTestTable OBJECT-TYPE SYNTAX SEQUENCE OF UMLiuTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The LIU table. The LIU attributes regarding configuration and performance are defined in RFC1406." ::= { hwCPET1E1 2 } umLiuTestEntry OBJECT-TYPE SYNTAX UMLiuTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in the LIU Test table." INDEX { ifIndex } ::= { umLiuTestTable 1 } UMLiuTestEntry ::= SEQUENCE { umLiuLoopbackConfig INTEGER, umLiuLoopbackStatus INTEGER, umLiuTestPattern INTEGER, umLiuTestPeriod INTEGER, umLiuTestStart TruthValue, umLiuInsertedErrorRate INTEGER, umLiuElapsedTime INTEGER, umLiuTestErrCount DisplayString, umLiuTestErrRate DisplayString } umLiuLoopbackConfig OBJECT-TYPE SYNTAX INTEGER { release(0), payload-loopback(1), line-loopback(2), local-loopback(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " This value is to set LIU loopback. 0: release 1: payload loopback 2: line loopback 3: local loopback " ::= { umLiuTestEntry 1 } umLiuLoopbackStatus OBJECT-TYPE SYNTAX INTEGER { release(0), payload-loopback(1), line-loopback(2), local-loopback(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " This value is to indicate the LIU loopback status. 0: released 1: payload loopback 2: line loopback 3: local loopback " ::= { umLiuTestEntry 2 } umLiuTestPattern OBJECT-TYPE SYNTAX INTEGER { pattern-2E15-1-PRBS(1), pattern-2047(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " This variable is used to set test pattern. 1: 2E15-1_PRBS 3: 2047 " ::= { umLiuTestEntry 3 } umLiuTestPeriod OBJECT-TYPE SYNTAX INTEGER (0..359999) MAX-ACCESS read-write STATUS current DESCRIPTION " This variable is used to set test period in second. A value of 0 means non-stop testing. " ::= { umLiuTestEntry 4 } umLiuTestStart OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION " This value is to start or stop testing. 1: Start 2: Stop " ::= { umLiuTestEntry 5 } umLiuInsertedErrorRate OBJECT-TYPE SYNTAX INTEGER (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION " This value is used to set inserted error rate. Inserted error rate = 1*10E(-n), where n is the set value. Set 0 to stop insertting errors. " ::= { umLiuTestEntry 6 } umLiuElapsedTime OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This variable is to indicate elapsed time of testing. " ::= { umLiuTestEntry 7 } umLiuTestErrCount OBJECT-TYPE SYNTAX DisplayString (SIZE (1..13)) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable is to indicate error count of testing. " ::= { umLiuTestEntry 8 } umLiuTestErrRate OBJECT-TYPE SYNTAX DisplayString (SIZE (13)) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable is to indicate error rate of testing, which is 'a.bcx10E(-d)', a, b, c: 0..9, d: 1..9." ::= { umLiuTestEntry 9 } umLiuThresholdTable OBJECT-TYPE SYNTAX SEQUENCE OF UMLiuThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Performance threshold table." ::= { hwCPET1E1 3 } umLiuThresholdEntry OBJECT-TYPE SYNTAX UMLiuThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry in Performance threshold table." INDEX { ifIndex } ::= { umLiuThresholdTable 1 } UMLiuThresholdEntry ::= SEQUENCE { umLiuThreshold15mLCV Gauge32, umLiuThreshold15mPCV Gauge32, umLiuThreshold15mES Gauge32, umLiuThreshold15mSES Gauge32, umLiuThreshold15mSEFS Gauge32, umLiuThreshold15mUAS Gauge32, umLiuThreshold15mCSS Gauge32, umLiuThreshold15mDM Gauge32, umLiuThreshold24hLCV Gauge32, umLiuThreshold24hPCV Gauge32, umLiuThreshold24hES Gauge32, umLiuThreshold24hSES Gauge32, umLiuThreshold24hSEFS Gauge32, umLiuThreshold24hUAS Gauge32, umLiuThreshold24hCSS Gauge32, umLiuThreshold24hDM Gauge32 } umLiuThreshold15mLCV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the threshold of LCV. This variable is valid for near end UM." ::= { umLiuThresholdEntry 1 } umLiuThreshold15mPCV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the threshold of PCV. " ::= { umLiuThresholdEntry 2 } umLiuThreshold15mES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the threshold of ES. " ::= { umLiuThresholdEntry 3 } umLiuThreshold15mSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the threshold of SES. " ::= { umLiuThresholdEntry 4 } umLiuThreshold15mSEFS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the threshold of SEFS. " ::= { umLiuThresholdEntry 5 } umLiuThreshold15mUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the threshold of UAS. " ::= { umLiuThresholdEntry 6 } umLiuThreshold15mCSS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the threshold of CSS. " ::= { umLiuThresholdEntry 7 } umLiuThreshold15mDM OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the threshold of DM. " ::= { umLiuThresholdEntry 8 } umLiuThreshold24hLCV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the threshold of LCV. This variable is valid for near end UM." ::= { umLiuThresholdEntry 9 } umLiuThreshold24hPCV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the threshold of PCV. " ::= { umLiuThresholdEntry 10 } umLiuThreshold24hES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the threshold of ES. " ::= { umLiuThresholdEntry 11 } umLiuThreshold24hSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the threshold of SES. " ::= { umLiuThresholdEntry 12 } umLiuThreshold24hSEFS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the threshold of SEFS. " ::= { umLiuThresholdEntry 13 } umLiuThreshold24hUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the threshold of UAS. " ::= { umLiuThresholdEntry 14 } umLiuThreshold24hCSS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the threshold of CSS. " ::= { umLiuThresholdEntry 15 } umLiuThreshold24hDM OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-write STATUS current DESCRIPTION "This variable defines the threshold of DM. " ::= { umLiuThresholdEntry 16 } umLiuPmData OBJECT IDENTIFIER ::= { hwCPET1E1 4 } umLiuPmCurrent15mTable OBJECT-TYPE SYNTAX SEQUENCE OF UMLiuPmCurrent15mEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Liu PM Current table." ::= { umLiuPmData 1 } umLiuPmCurrent15mEntry OBJECT-TYPE SYNTAX UMLiuPmCurrent15mEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Liu Pm Current 15 minutes table." INDEX { ifIndex } ::= { umLiuPmCurrent15mTable 1 } UMLiuPmCurrent15mEntry ::= SEQUENCE { umLiuPmCurrent15mLCV Gauge32, umLiuPmCurrent15mPCV Gauge32, umLiuPmCurrent15mES Gauge32, umLiuPmCurrent15mSES Gauge32, umLiuPmCurrent15mSEFS Gauge32, umLiuPmCurrent15mUAS Gauge32, umLiuPmCurrent15mCSS Gauge32, umLiuPmCurrent15mDM Gauge32, umLiuPmCurrent15mCS Gauge32, umLiuPmCurrent15mFBE Gauge32 } umLiuPmCurrent15mLCV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Line Code Violations encountered by an LIU interface in the current quarter." ::= { umLiuPmCurrent15mEntry 1 } umLiuPmCurrent15mPCV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Path Coding Violations encountered by an LIU interface in the current quarter." ::= { umLiuPmCurrent15mEntry 2 } umLiuPmCurrent15mES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds encountered by an LIU interface in the current quarter." ::= { umLiuPmCurrent15mEntry 3 } umLiuPmCurrent15mSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Seconds encountered by an LIU interface in the current quarter." ::= { umLiuPmCurrent15mEntry 4 } umLiuPmCurrent15mSEFS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Framing Seconds encountered by an LIU interface in the current quarter." ::= { umLiuPmCurrent15mEntry 5 } umLiuPmCurrent15mUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds encountered by an LIU interface in the current quarter." ::= { umLiuPmCurrent15mEntry 6 } umLiuPmCurrent15mCSS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Controlled Slip Seconds encountered by an LIU interface in the current quarter." ::= { umLiuPmCurrent15mEntry 7 } umLiuPmCurrent15mDM OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Degraded Minutes encountered by an LIU interface in the current quarter." ::= { umLiuPmCurrent15mEntry 8 } umLiuPmCurrent15mCS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Controlled Slip encountered by an LIU interface in the current quarter." ::= { umLiuPmCurrent15mEntry 9 } umLiuPmCurrent15mFBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Loss Of Frame encountered by an LIU interface in current quarter." ::= { umLiuPmCurrent15mEntry 10 } umLiuPm15mTable OBJECT-TYPE SYNTAX SEQUENCE OF UMLiuPm15mEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Liu PM 15 minutes Interval table." ::= { umLiuPmData 2 } umLiuPm15mEntry OBJECT-TYPE SYNTAX UMLiuPm15mEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Liu Pm Interval table." INDEX { ifIndex, umLiuPm15mIndex } ::= { umLiuPm15mTable 1 } UMLiuPm15mEntry ::= SEQUENCE { umLiuPm15mIndex INTEGER, umLiuPm15mLCV Gauge32, umLiuPm15mPCV Gauge32, umLiuPm15mES Gauge32, umLiuPm15mSES Gauge32, umLiuPm15mSEFS Gauge32, umLiuPm15mUAS Gauge32, umLiuPm15mCSS Gauge32, umLiuPm15mDM Gauge32, umLiuPm15mCS Gauge32, umLiuPm15mFBE Gauge32 } umLiuPm15mIndex OBJECT-TYPE SYNTAX INTEGER (1..96) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { umLiuPm15mEntry 1 } umLiuPm15mLCV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Line Code Violations encountered by a LIU interface in one of the previous 96, individual 15 minute, intervals. " ::= { umLiuPm15mEntry 2 } umLiuPm15mPCV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Path Coding Violations encountered by a LIU interface in one of the previous 96, individual 15 minute, intervals. " ::= { umLiuPm15mEntry 3 } umLiuPm15mES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds encountered by a LIU interface in one of the previous 96, individual 15 minute, intervals. " ::= { umLiuPm15mEntry 4 } umLiuPm15mSES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Seconds encountered by a LIU interface in one of the previous 96, individual 15 minute, intervals. " ::= { umLiuPm15mEntry 5 } umLiuPm15mSEFS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Framing Seconds encountered by a LIU interface in one of the previous 96, individual 15 minute, intervals. " ::= { umLiuPm15mEntry 6 } umLiuPm15mUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds encountered by a LIU interface in one of the previous 96, individual 15 minute, intervals. " ::= { umLiuPm15mEntry 7 } umLiuPm15mCSS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Controlled Slip Seconds encountered by a LIU interface in one of the previous 96, individual 15 minute, intervals. " ::= { umLiuPm15mEntry 8 } umLiuPm15mDM OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Degraded Minutes encountered by a LIU interface in one of the previous 96, individual 15 minute, intervals. " ::= { umLiuPm15mEntry 9 } umLiuPm15mCS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Controlled Slip encountered by a LIU interface in one of the previous 96, individual 15 minute, intervals. " ::= { umLiuPm15mEntry 10 } umLiuPm15mFBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Loss Of Frame encountered by a LIU interface in one of the previous 96, individual 15 minute, intervals. " ::= { umLiuPm15mEntry 11 } umLiuPmCurrentDayTable OBJECT-TYPE SYNTAX SEQUENCE OF UMLiuPmCurrentDayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Liu PM Current Day table." ::= { umLiuPmData 3 } umLiuPmCurrentDayEntry OBJECT-TYPE SYNTAX UMLiuPmCurrentDayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Liu Pm Current Day table." INDEX { ifIndex } ::= { umLiuPmCurrentDayTable 1 } UMLiuPmCurrentDayEntry ::= SEQUENCE { umLiuPmCurrentDayLCV Gauge32, umLiuPmCurrentDayPCV Gauge32, umLiuPmCurrentDayES Gauge32, umLiuPmCurrentDaySES Gauge32, umLiuPmCurrentDaySEFS Gauge32, umLiuPmCurrentDayUAS Gauge32, umLiuPmCurrentDayCSS Gauge32, umLiuPmCurrentDayDM Gauge32, umLiuPmCurrentDayCS Gauge32, umLiuPmCurrentDayFBE Gauge32 } umLiuPmCurrentDayLCV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Line Code Violations encountered by an LIU interface in current day." ::= { umLiuPmCurrentDayEntry 1 } umLiuPmCurrentDayPCV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Path Coding Violations encountered by an LIU interface in current day." ::= { umLiuPmCurrentDayEntry 2 } umLiuPmCurrentDayES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds encountered by an LIU interface in current day." ::= { umLiuPmCurrentDayEntry 3 } umLiuPmCurrentDaySES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Seconds encountered by an LIU interface in current day." ::= { umLiuPmCurrentDayEntry 4 } umLiuPmCurrentDaySEFS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Framing Seconds encountered by an LIU interface in current day." ::= { umLiuPmCurrentDayEntry 5 } umLiuPmCurrentDayUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds encountered by an LIU interface in current day." ::= { umLiuPmCurrentDayEntry 6 } umLiuPmCurrentDayCSS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Controlled Slip Seconds encountered by an LIU interface in current day." ::= { umLiuPmCurrentDayEntry 7 } umLiuPmCurrentDayDM OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Degraded Minutes encountered by an LIU interface in current day." ::= { umLiuPmCurrentDayEntry 8 } umLiuPmCurrentDayCS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Controlled Slip encountered by an LIU interface in current day." ::= { umLiuPmCurrentDayEntry 9 } umLiuPmCurrentDayFBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Loss Of Frame encountered by an LIU interface in current day." ::= { umLiuPmCurrentDayEntry 10 } umLiuPmDayTable OBJECT-TYPE SYNTAX SEQUENCE OF UMLiuPmDayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Liu PM Day table." ::= { umLiuPmData 4 } umLiuPmDayEntry OBJECT-TYPE SYNTAX UMLiuPmDayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Liu Pm Day table." INDEX { ifIndex, umLiuPmDayIndex } ::= { umLiuPmDayTable 1 } UMLiuPmDayEntry ::= SEQUENCE { umLiuPmDayIndex INTEGER, umLiuPmDayLCV Gauge32, umLiuPmDayPCV Gauge32, umLiuPmDayES Gauge32, umLiuPmDaySES Gauge32, umLiuPmDaySEFS Gauge32, umLiuPmDayUAS Gauge32, umLiuPmDayCSS Gauge32, umLiuPmDayDM Gauge32, umLiuPmDayCS Gauge32, umLiuPmDayFBE Gauge32 } umLiuPmDayIndex OBJECT-TYPE SYNTAX INTEGER (1..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A number between 1 and 7, where 1 is PM data of the most recently completed day and 7 is PM data of the least completed recently day. " ::= { umLiuPmDayEntry 1 } umLiuPmDayLCV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Line Code Violations encountered by an LIU interface in one day." ::= { umLiuPmDayEntry 2 } umLiuPmDayPCV OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Path Coding Violations encountered by an LIU interface in one day." ::= { umLiuPmDayEntry 3 } umLiuPmDayES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds encountered by an LIU interface in one day." ::= { umLiuPmDayEntry 4 } umLiuPmDaySES OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Seconds encountered by an LIU interface in one day." ::= { umLiuPmDayEntry 5 } umLiuPmDaySEFS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Framing Seconds encountered by an LIU interface in one day." ::= { umLiuPmDayEntry 6 } umLiuPmDayUAS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds encountered by an LIU interface in one day." ::= { umLiuPmDayEntry 7 } umLiuPmDayCSS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Controlled Slip Seconds encountered by an LIU interface in one day." ::= { umLiuPmDayEntry 8 } umLiuPmDayDM OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Degraded Minutes encountered by an LIU interface in one day." ::= { umLiuPmDayEntry 9 } umLiuPmDayCS OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Controlled Slip encountered by an LIU interface in one day." ::= { umLiuPmDayEntry 10 } umLiuPmDayFBE OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Loss Of Frame by an LIU interface in one day." ::= { umLiuPmDayEntry 11 } umSdslE1T1AlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF UMSdslE1T1AlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SDSL E1T1 alarm table." ::= { hwCPET1E1 5 } umSdslE1T1AlarmEntry OBJECT-TYPE SYNTAX UMSdslE1T1AlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the SDSL alarm table." INDEX { ifIndex } ::= { umSdslE1T1AlarmTable 1 } UMSdslE1T1AlarmEntry ::= SEQUENCE { umSdslE1T1ClearAlarmHistory TruthValue, umSdslE1T1LocalAlarmStatus Unsigned32, umSdslE1T1SdslAlarmStatus Unsigned32 } umSdslE1T1ClearAlarmHistory OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION " The variable initiate the clear alarm history action(Set 1). " ::= { umSdslE1T1AlarmEntry 1 } umSdslE1T1LocalAlarmStatus OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION " The variable initiate the local current alarm status. (bit) 0: (E1T1) E1 LOS Failure (Loss of signal) 1: (E1T1) Loss of Frame Alignment 2: (E1T1) Loss of E1T1 Multiframe Alignment 3: (E1T1) AIS received 4: (E1T1) AIS received in TS16 5: (E1T1) RAI received 6: (E1T1) RAI received in TS16 7: (E1T1) Bit errors exceed error ratio 8: (E1T1) LCV exceed day threshold 9: (E1T1) LCV exceed quarter threshold 10: (E1T1) PCV exceed day threshold 11: (E1T1) PCV exceed quarter threshold 12: (E1T1) ES exceed day threshold 13: (E1T1) ES exceed quarter threshold 14: (E1T1) SES exceed day threshold 15: (E1T1) SES exceed quarter threshold 16: (E1T1) SEFS exceed day threshold 17: (E1T1) SEFS exceed quarter threshold 18: (E1T1) UAS exceed day threshold 19: (E1T1) UAS exceed quarter threshold 20: (E1T1) CSS exceed day threshold 21: (E1T1) CSS exceed quarter threshold 22: (E1T1) DM exceed day threshold 23: (E1T1) DM exceed quarter threshold 24~31 Reserved DataType 103 " ::= { umSdslE1T1AlarmEntry 2 } umSdslE1T1SdslAlarmStatus OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION " The variable initiate the E1T1 SHDSL current alarm status. (bit) 0: (SDSL) LOSW Failure (Loss of SDSL synchronization word) 1: (SDSL) ES exceed day threshold 2: (SDSL) ES exceed quarter threshold 3: (SDSL) SES exceed day threshold 4: (SDSL) SES exceed quarter threshold 5: (SDSL) UAS exceed day threshold 6: (SDSL) UAS exceed quarter threshold 7: (SDSL) SNR exceed threshold 8: (SDSL) Loop Attuattion exceed threshold 9~31 Reserved DataType 103 " ::= { umSdslE1T1AlarmEntry 3 } END