-- ============================================================================ -- Copyright (C) 2003 by HUAWEI TECHNOLOGIES. All rights reserved. -- -- Description: -- Reference: -- Version: V3.00 -- History: -- liu chenglong 20030428 Added IPR Decriptions and updated all MIB version to V3.00 -- ============================================================================ HUAWEI-VPRING-MIB DEFINITIONS ::= BEGIN IMPORTS huaweiUtility FROM HUAWEI-MIB OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI RowStatus, DisplayString, TruthValue FROM SNMPv2-TC; hwVPRing MODULE-IDENTITY LAST-UPDATED "200304280900Z" ORGANIZATION "Fix-Net Dep, Huawei Technologies Co.,Ltd." CONTACT-INFO "Floot 5 ,Block 4, R&D Building, Huawei Longgang Production Base, Shenzhen, P.R.C. http://www.huawei.com Zip:518057 " DESCRIPTION "huawei ATM VPRING MIb " REVISION "200211290900Z" DESCRIPTION " Huawei VPRING MIB" ::= { huaweiUtility 20 } -- -- Node definitions -- hwAtmApsVpRingTable OBJECT-TYPE SYNTAX SEQUENCE OF HwAtmApsVpRingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { hwVPRing 1 } hwAtmApsVpRingEntry OBJECT-TYPE SYNTAX HwAtmApsVpRingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { hwAtmApsVpRingIndex } ::= { hwAtmApsVpRingTable 1 } HwAtmApsVpRingEntry ::= SEQUENCE { hwAtmApsVpRingIndex INTEGER, hwAtmApsVpRingPosition INTEGER, hwAtmApsVpRingFrameID1 INTEGER, hwAtmApsVpRingSlotID1 INTEGER, hwAtmApsVpRingPortID1 INTEGER, hwAtmApsVpRingFrameID2 INTEGER, hwAtmApsVpRingSlotID2 INTEGER, hwAtmApsVpRingPortID2 INTEGER, hwAtmApsVpRingRowStatus RowStatus } hwAtmApsVpRingIndex OBJECT-TYPE SYNTAX INTEGER (0..15) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { hwAtmApsVpRingEntry 1 } hwAtmApsVpRingPosition OBJECT-TYPE SYNTAX INTEGER (0..15) MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVpRingEntry 2 } hwAtmApsVpRingFrameID1 OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVpRingEntry 3 } hwAtmApsVpRingSlotID1 OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVpRingEntry 4 } hwAtmApsVpRingPortID1 OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVpRingEntry 5 } hwAtmApsVpRingFrameID2 OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVpRingEntry 6 } hwAtmApsVpRingSlotID2 OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVpRingEntry 7 } hwAtmApsVpRingPortID2 OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVpRingEntry 8 } hwAtmApsVpRingRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVpRingEntry 9 } -- hwAtmApsVPGConfigTable -- hwAtmApsVPGConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF HwAtmApsVPGConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { hwVPRing 2 } hwAtmApsVPGConfigEntry OBJECT-TYPE SYNTAX HwAtmApsVPGConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { hwAtmApsVPGIndex } ::= { hwAtmApsVPGConfigTable 1 } HwAtmApsVPGConfigEntry ::= SEQUENCE { hwAtmApsVPGIndex INTEGER, hwAtmApsVPGName DisplayString, hwAtmApsVPGWorkingFrameID INTEGER, hwAtmApsVPGWorkingSlotID INTEGER, hwAtmApsVPGWorkingPhyportID INTEGER, hwAtmApsVPGProtectionFrameID INTEGER, hwAtmApsVPGProtectionSlotID INTEGER, hwAtmApsVPGProtectionPhyportID INTEGER, hwAtmApsVPGMode INTEGER, hwAtmApsVPGWTRTime INTEGER, hwAtmApsVPGExternalCommands INTEGER, hwAtmApsVPGProtectK1K2Rcv INTEGER, hwAtmApsVPGProtectK1K2Trans INTEGER, hwAtmApsVPGWorkingEntityStatus BITS, hwAtmApsVPGProtectionEntityStatus BITS, hwAtmApsVPGCurrEntity INTEGER, hwAtmApsVPGApsStatus INTEGER, hwAtmApsVPGVplIsInUse TruthValue, hwAtmApsVPGVpRingIndex INTEGER, hwAtmApsVPGRevertive TruthValue, hwAtmApsVPGRowStatus RowStatus } hwAtmApsVPGIndex OBJECT-TYPE SYNTAX INTEGER (1..256) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " " ::= { hwAtmApsVPGConfigEntry 1 } hwAtmApsVPGName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..51)) MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= { hwAtmApsVPGConfigEntry 2 } hwAtmApsVPGWorkingFrameID OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVPGConfigEntry 3 } hwAtmApsVPGWorkingSlotID OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVPGConfigEntry 4 } hwAtmApsVPGWorkingPhyportID OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVPGConfigEntry 5 } hwAtmApsVPGProtectionFrameID OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVPGConfigEntry 6 } hwAtmApsVPGProtectionSlotID OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVPGConfigEntry 7 } hwAtmApsVPGProtectionPhyportID OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVPGConfigEntry 8 } hwAtmApsVPGMode OBJECT-TYPE SYNTAX INTEGER { onePlusOneUnidirection(1), onePlusOneBidirection(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= { hwAtmApsVPGConfigEntry 9 } hwAtmApsVPGWTRTime OBJECT-TYPE SYNTAX INTEGER (1..30) MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= { hwAtmApsVPGConfigEntry 10 } hwAtmApsVPGExternalCommands OBJECT-TYPE SYNTAX INTEGER { clear(1), freeze(2), lockoutOfProtection(3), forcedSwitchForWorking(4), manualSwitchForWorking(5), manualSwitchForProtection(6) } MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= { hwAtmApsVPGConfigEntry 11 } hwAtmApsVPGProtectK1K2Rcv OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { hwAtmApsVPGConfigEntry 12 } hwAtmApsVPGProtectK1K2Trans OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { hwAtmApsVPGConfigEntry 13 } hwAtmApsVPGWorkingEntityStatus OBJECT-TYPE SYNTAX BITS { lof(1), los(2), sd(3), rdi(4), ais(5), rsd(6) } MAX-ACCESS read-only STATUS current DESCRIPTION " 0x00000002-RSD 0x00000004-AIS, 0x00000008-RDI, 0x00000010-SD, 0x00000020-LOS, 0x00000040-LOF" ::= { hwAtmApsVPGConfigEntry 14 } hwAtmApsVPGProtectionEntityStatus OBJECT-TYPE SYNTAX BITS { lof(1), los(2), sd(3), rdi(4), ais(5), rsd(6) } MAX-ACCESS read-only STATUS current DESCRIPTION " 0x00000002-RSD 0x00000004-AIS, 0x00000008-RDI, 0x00000010-SD, 0x00000020-LOS, 0x00000040-LOF" ::= { hwAtmApsVPGConfigEntry 15 } hwAtmApsVPGCurrEntity OBJECT-TYPE SYNTAX INTEGER { work(1), protect(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { hwAtmApsVPGConfigEntry 16 } hwAtmApsVPGApsStatus OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " Bidirectional APSC: 0x00000080-DNR, 0x00000100-rsv1, 0x00000200-WTR, 0x00000400-rsv2, 0x00000800-MS-W, 0x00001000-MS-P, 0x00002000-rsv3, 0x00004000-SD-W, 0x00008000-SD-P, 0x00010000-rsv4, 0x00020000-SF-W, 0x00040000-rsv5, 0x00080000-FS-W, 0x00100000-SF-P, 0x00200000-LOP, 0x00400000-FREEZE, 0x00800000-CLEAR, Unidirectional APSC: 0x01000000-WTR, 0x02000000-MS-P, 0x04000000-MS-W, 0x08000000-SD, 0x10000000-SF, 0x20000000-FS, 0x40000000-LOP, 0x80000000-CLEAR " ::= { hwAtmApsVPGConfigEntry 17 } hwAtmApsVPGVplIsInUse OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION " enable(1), disable(2)" ::= { hwAtmApsVPGConfigEntry 18 } hwAtmApsVPGVpRingIndex OBJECT-TYPE SYNTAX INTEGER (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { hwAtmApsVPGConfigEntry 19 } hwAtmApsVPGRevertive OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION " revertible(1), non-revertible(2)" ::= { hwAtmApsVPGConfigEntry 20 } hwAtmApsVPGRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVPGConfigEntry 21 } -- hwAtmApsVPGVplTable -- hwAtmApsVPGVplTable OBJECT-TYPE SYNTAX SEQUENCE OF HwAtmApsVPGVplEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { hwVPRing 3 } hwAtmApsVPGVplEntry OBJECT-TYPE SYNTAX HwAtmApsVPGVplEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { hwAtmApsVPGIndex, hwAtmApsVPGVplWorkingVpi } ::= { hwAtmApsVPGVplTable 1 } HwAtmApsVPGVplEntry ::= SEQUENCE { hwAtmApsVPGVplWorkingVpi INTEGER, hwAtmApsVPGVplProtectionVpi INTEGER, hwAtmApsVPGVplServiceClass INTEGER, hwAtmApsVPGVplRowStaus RowStatus, hwAtmApsVPGVplTrafficTableIndex INTEGER } hwAtmApsVPGVplWorkingVpi OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { hwAtmApsVPGVplEntry 1 } hwAtmApsVPGVplProtectionVpi OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVPGVplEntry 2 } hwAtmApsVPGVplServiceClass OBJECT-TYPE SYNTAX INTEGER { cbr(1), rtvbr(2), nrtvbr(3), abr(4), ubr(5) } MAX-ACCESS read-create STATUS deprecated DESCRIPTION " " ::= { hwAtmApsVPGVplEntry 3 } hwAtmApsVPGVplRowStaus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVPGVplEntry 4 } hwAtmApsVPGVplTrafficTableIndex OBJECT-TYPE SYNTAX INTEGER (0..511) MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsVPGVplEntry 5 } -- hwAtmApsAPSChannelTable -- hwAtmApsAPSChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF HwAtmApsAPSChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { hwVPRing 4 } hwAtmApsAPSChannelEntry OBJECT-TYPE SYNTAX HwAtmApsAPSChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { hwAtmApsAPSChannelFrameID, hwAtmApsAPSChannelSlotID, hwAtmApsAPSChannelPhyport, hwAtmApsAPSChannelVpi } ::= { hwAtmApsAPSChannelTable 1 } HwAtmApsAPSChannelEntry ::= SEQUENCE { hwAtmApsAPSChannelFrameID INTEGER, hwAtmApsAPSChannelSlotID INTEGER, hwAtmApsAPSChannelPhyport INTEGER, hwAtmApsAPSChannelVpi INTEGER, hwAtmApsAPSChannelGroupIndex INTEGER, hwAtmApsAPSChannelVlType INTEGER, hwAtmApsAPSChannelRowStaus RowStatus } hwAtmApsAPSChannelFrameID OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { hwAtmApsAPSChannelEntry 1 } hwAtmApsAPSChannelSlotID OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { hwAtmApsAPSChannelEntry 2 } hwAtmApsAPSChannelPhyport OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { hwAtmApsAPSChannelEntry 3 } hwAtmApsAPSChannelVpi OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { hwAtmApsAPSChannelEntry 4 } hwAtmApsAPSChannelGroupIndex OBJECT-TYPE SYNTAX INTEGER (1..256) MAX-ACCESS read-create STATUS current DESCRIPTION " APS " ::= { hwAtmApsAPSChannelEntry 5 } hwAtmApsAPSChannelVlType OBJECT-TYPE SYNTAX INTEGER { p2p(1), w-leaf(2), p-leaf(3) } MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsAPSChannelEntry 6 } hwAtmApsAPSChannelRowStaus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION " " ::= { hwAtmApsAPSChannelEntry 7 } hwVPRingSnmpTrapDef OBJECT IDENTIFIER ::= { hwVPRing 5 } hwAtmApsTraps OBJECT IDENTIFIER ::= { hwVPRingSnmpTrapDef 0 } hwAtmApsVPGStatusTraps NOTIFICATION-TYPE OBJECTS { hwAtmApsVPGIndex, hwAtmApsVPGProtectK1K2Rcv, hwAtmApsVPGProtectK1K2Trans, hwAtmApsVPGWorkingEntityStatus, hwAtmApsVPGProtectionEntityStatus, hwAtmApsVPGCurrEntity, hwAtmApsVPGApsStatus } STATUS current DESCRIPTION "vp group dynamic status trap: 1:hwAtmApsVPGIndex, 2:hwAtmApsVPGProtectK1K2Rcv, 3:hwAtmApsVPGProtectK1K2Trans, 4:hwAtmApsVPGWorkingEntityStatus, 5:hwAtmApsVPGProtectionEntityStatus, 6:hwAtmApsVPGCurrEntity, 7:hwAtmApsVPGApsStatus " ::= { hwAtmApsTraps 1 } hwAtmApsVPGProtectionSwitching NOTIFICATION-TYPE OBJECTS { hwAtmApsVPGWorkingFrameID, hwAtmApsVPGWorkingSlotID, hwAtmApsVPGWorkingPhyportID, hwAtmApsVPGIndex, hwAtmApsVPGProtectionSwitchingReason } STATUS current DESCRIPTION "alarm description:VP Channel Protection Switching explain: 1.Loss of signal, 2.Deterioration of signal, 3.User operation, 4.Remote request causes switchover resolving method: 1.Check if the transmission optical fiber is broken, 2.Check if the transmission line quality is deteriorated, 3.If it is the above 3/4 reason,no need to proceed. " ::= { hwAtmApsTraps 2 } hwAtmApsVPGProtectionSwitchingFail NOTIFICATION-TYPE OBJECTS { hwAtmApsVPGWorkingFrameID, hwAtmApsVPGWorkingSlotID, hwAtmApsVPGWorkingPhyportID, hwAtmApsVPGIndex, hwAtmApsVPGProtectionSwitchingFailReason } STATUS current DESCRIPTION "alarm description:VP Channel Protection Switching fails explain: 1.Command execution time out, 2.VP group status abnormal caused by insufficient synchronization of active and standby boards resolving method: 1.Check if the interface board works normally, 2.There is no need to proceed. The VPRING data will be recovered within three minutes " ::= { hwAtmApsTraps 3 } hwAtmApsVPGProtectionSwitchingClear NOTIFICATION-TYPE OBJECTS { hwAtmApsVPGWorkingFrameID, hwAtmApsVPGWorkingSlotID, hwAtmApsVPGWorkingPhyportID, hwAtmApsVPGIndex, hwAtmApsVPGProtectionSwitchingClearReason } STATUS current DESCRIPTION "alarm description:VP Channel Protection Switching is cleared explain: 1.The local/remote working channel is recovered, or there is no switchover request at present, 2.Remote request causes switchover resolving method: 1.No need to proceed " ::= { hwAtmApsTraps 4 } hwAtmApsVPGProtectionSwitchingClearFail NOTIFICATION-TYPE OBJECTS { hwAtmApsVPGWorkingFrameID, hwAtmApsVPGWorkingSlotID, hwAtmApsVPGWorkingPhyportID, hwAtmApsVPGIndex, hwAtmApsVPGProtectionSwitchingClearFailReason } STATUS current DESCRIPTION "alarm description:fail to clear VP Channel Protection Switching explain: 1.Command execution time out, 2.VP group status abnormal caused by insufficient synchronization of active and standby boards resolving method: 1.Check if the interface board works normally, 2.There is no need to proceed. The VPRING data will be recovered within three minutes " ::= { hwAtmApsTraps 5 } hwAtmApsVPGKByteMismatch NOTIFICATION-TYPE OBJECTS { hwAtmApsVPGIndex, hwAtmApsVPGProtectK1K2Rcv, hwAtmApsVPGProtectK1K2Trans, hwAtmApsVPGKByteMismatchReason } STATUS current DESCRIPTION "alarm description:The received K2 byte are not the same as transmitted one explain: 1.Local and remote switchover status inconsistent, 2.Current status of the local protection switchover is frozen resolving method: 1.No need to proceed, 2.Disable the freezing of current status of the local protection switchover " ::= { hwAtmApsTraps 6 } hwAtmApsVPGStartPSFail NOTIFICATION-TYPE OBJECTS { hwAtmApsVPGWorkingFrameID, hwAtmApsVPGWorkingSlotID, hwAtmApsVPGWorkingPhyportID, hwAtmApsVPGIndex, hwAtmApsVPGStartPSFailReason } STATUS current DESCRIPTION "alarm description:fail to Start protection switching explain: 1.Command execution time out resolving method: 1.Check if the interface board works normally " ::= { hwAtmApsTraps 7 } hwAtmApsAlmBindReason OBJECT IDENTIFIER ::= { hwVPRingSnmpTrapDef 2 } hwAtmApsVPGProtectionSwitchingReason OBJECT-TYPE SYNTAX INTEGER { lossofsignal(1), signaldegrade(2), useroperation(3), farProtectionSwitching(4) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " alarm description:VP Channel Protection Switching explain: 1.Loss of signal, 2.Deterioration of signal, 3.User operation, 4.Remote request causes switchover resolving method: 1.Check if the transmission optical fiber is broken, 2.Check if the transmission line quality is deteriorated, 3.If it is the above 3/4 reason,no need to proceed. " ::= { hwAtmApsAlmBindReason 1 } hwAtmApsVPGProtectionSwitchingFailReason OBJECT-TYPE SYNTAX INTEGER { timeout(1), statusabnormal(2) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " alarm description:VP Channel Protection Switching fails explain: 1.Command execution time out, 2.VP group status abnormal caused by insufficient synchronization of active and standby boards resolving method: 1.Check if the interface board works normally, 2.There is no need to proceed. The VPRING data will be recovered within three minutes " ::= { hwAtmApsAlmBindReason 2 } hwAtmApsVPGProtectionSwitchingClearReason OBJECT-TYPE SYNTAX INTEGER { farandlocalNR(1), farrequest(2) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " alarm description:VP Channel Protection Switching is cleared explain: 1.The local/remote working channel is recovered, or there is no switchover request at present, 2.Remote request causes switchover resolving method: 1.No need to proceed " ::= { hwAtmApsAlmBindReason 3 } hwAtmApsVPGProtectionSwitchingClearFailReason OBJECT-TYPE SYNTAX INTEGER { timeout(1), statusabnormal(2) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " alarm description:fail to clear VP Channel Protection Switching explain: 1.Command execution time out, 2.VP group status abnormal caused by insufficient synchronization of active and standby boards resolving method: 1.Check if the interface board works normally, 2.There is no need to proceed. The VPRING data will be recovered within three minutes " ::= { hwAtmApsAlmBindReason 4 } hwAtmApsVPGKByteMismatchReason OBJECT-TYPE SYNTAX INTEGER { statuserror(1), freezelocalswitchingstatus(2) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " alarm description:The received K2 byte are not the same as transmitted one explain: 1.Local and remote switchover status inconsistent, 2.Current status of the local protection switchover is frozen resolving method: 1.No need to proceed, 2.Disable the freezing of current status of the local protection switchover " ::= { hwAtmApsAlmBindReason 5 } hwAtmApsVPGStartPSFailReason OBJECT-TYPE SYNTAX INTEGER { timeout(1) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " alarm description:fail to Start protection switching explain: 1.Command execution time out resolving method: 1.Check if the interface board works normally " ::= { hwAtmApsAlmBindReason 6 } END -- -- HUAWEI-VPRING-MIB.my --