-- SECTION 1: Top Level Definitions HP-SN-SWITCH-GROUP-MIB DEFINITIONS ::= BEGIN -- Foundry SnSwitch Group MIB Release 2.0.0 -- Revision 0 08/18/96 -- Copyright 1996-97 Foundry Networks, Inc. -- All rights reserved. -- This Foundry Networks SNMP Management Information Base Specification -- (Specification) embodies Foundry Networks' confidential and -- proprietary intellectual property. Foundry Networks retains all -- title and ownership in the Specification, including any -- revisions. -- This Specification is supplied "AS IS," and Foundry Networks makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. -- Imports IMPORTS Counter, TimeTicks, IpAddress, Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 snSwitch FROM HP-SN-ROOT-MIB; -- textual conventions DisplayString ::= OCTET STRING -- This data type is used to model textual information taken -- from the NVT ASCII character set. By convention, objects -- with this syntax are declared as having -- -- SIZE (0..255) PhysAddress ::= OCTET STRING -- This data type is used to model media addresses. For many -- types of media, this will be in a binary representation. -- For example, an ethernet address would be represented as -- a string of 6 octets. MacAddress ::= OCTET STRING (SIZE(6)) -- This data type is used to model media addresses. For many -- types of media, this will be in a binary representation. -- For example, an ethernet address would be represented as -- a string of 6 octets. BridgeId ::= OCTET STRING (SIZE(8)) -- the Bridge-Identifier as used in the Spanning Tree Timeout ::= INTEGER -- a STP timer in units of 1/100 seconds PortMask ::= INTEGER -- This data type is used to model port bitmask. The -- maximum of ports are 32. -- Groups snSwInfo OBJECT IDENTIFIER ::= { snSwitch 1 } snVLanInfo OBJECT IDENTIFIER ::= { snSwitch 2 } snSwPortInfo OBJECT IDENTIFIER ::= { snSwitch 3 } snFdbInfo OBJECT IDENTIFIER ::= { snSwitch 4 } snPortStpInfo OBJECT IDENTIFIER ::= { snSwitch 5 } snTrunkInfo OBJECT IDENTIFIER ::= { snSwitch 6 } snSwSummary OBJECT IDENTIFIER ::= { snSwitch 7 } snDhcpGatewayListInfo OBJECT IDENTIFIER ::= { snSwitch 8 } snDnsInfo OBJECT IDENTIFIER ::= { snSwitch 9 } snMacFilter OBJECT IDENTIFIER ::= { snSwitch 10 } snNTP OBJECT IDENTIFIER ::= { snSwitch 11 } snRadius OBJECT IDENTIFIER ::= { snSwitch 12 } snTacacs OBJECT IDENTIFIER ::= { snSwitch 13 } snQos OBJECT IDENTIFIER ::= { snSwitch 14 } -- SECTION 2: Switch Group Configuration MIBs snSwGroupOperMode OBJECT-TYPE SYNTAX INTEGER { noVLan(1), vlanByPort(2) } ACCESS read-write STATUS mandatory DESCRIPTION "noVLan(1) represents all switch ports with no virtual LAN by port (no Port VLAN), and with no tag assigned. vlanByPort(2) represents all switch ports with Basic VLAN (layer2 Switch). " ::= { snSwInfo 1 } snSwGroupIpL3SwMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The Switch Group is configured with the Layer3 IP Switch mode either enabled or disabled and the default is disabled mode. enabled(1)...........activate Layer3 IP Switch disabled(0)..........disable Layer3 IP Switch" ::= { snSwInfo 2 } snSwGroupIpMcastMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The Switch Group is configured with the IP Multicast pruning mode either enabled or disabled and the default is disabled mode. enabled(1)...........activate IP Multicast pruning disabled(0)..........no IP Multicast pruning" ::= { snSwInfo 3 } snSwGroupDefaultCfgMode OBJECT-TYPE SYNTAX INTEGER { default(1), nonDefault(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The Switch Group is configured with the Default configuration. If the default configuration gets overwritten, the state will change to non-default. default(1)...........default configuration nonDefault(2)..........non default configuration" ::= { snSwInfo 4 } snSwGroupSwitchAgeTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Switch Age time is 180sec by default. The configured range is 10 to 10,000sec. The time represents the time span to age out an MAC Address entry." ::= { snSwInfo 5 } snVLanGroupVlanCurEntry OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current total entry number of VLANs are configured." ::= { snSwInfo 6 } snVLanGroupSetAllVLan OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the VLanIndex of a particalur entry in snVLanByPortTable (snVLanByPortVLanIndex). All the attributes of that row of table except PortMask will be used to set the same attributes for the entire VLan group. VLanId and PortMask must be set for that particular entry prior to setting this object. Switch software will base on that VLAN information to set the entire VLAN. Note: All the intended attributes of the given row of the table (given VLAN) must be set prior setting this object. When this object is set, Set-All-VLAN action will take place simultaneously. The previous setting will be overwritten by the new one." ::= { snSwInfo 7 } snSwPortSetAll OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the index number of the snSwPortInfoTable (snSwPortInfoPortIndex). snSwPortInfoMonitorMode, snSwPortInfoTagType, snSwPortInfoChnMode, snSwPortInfoSpeed, snSwPortInfoAdminStatus are all the read-write attributes of that row of table. They will be used to set the same attributes for all the ports in the system. Note: prior setting this object, all the intended attributes of the given row of the table must be set. Otherwise, the current data of the row will be used to set the entire port-table. The previous setting will be overwritten by the new one." ::= { snSwInfo 8 } snFdbTableCurEntry OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current total entry number of FDB are configured." ::= { snSwInfo 9 } snFdbTableStationFlush OBJECT-TYPE SYNTAX INTEGER { normal(1), error(2), flush(3), flushing(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The following values of the flush state can only be read: normal(1)... normal state error(2)... operation failed flushing(4)... in process The following value can be written: flush(3).....do flush The agent will return a response even before the flush is done. And the read value will be flushing until flush is done. And the flush request will be rejected until error or normal." ::= { snSwInfo 10 } snPortStpSetAll OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is 1 which means invoking Port STP Set-all command. The snPortStpPriority, snPortStpPathCost, the read-write STP related attributes of the first row of table will be used to set the same attributes for all the ports in the system. Note: prior setting this object, all the intended attributes of the given row of the table must be set. Otherwise, the current data of the row will be used to set the entire port-table. The previous setting will be overwritten by the new one." ::= { snSwInfo 11 } snSwProbePortNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A chassis switch probe port is operated as a traffic analyzer port and only one port can be assigned in the chassis. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number. A stackable switch is only assigned with one probe port as a traffic analyzer." ::= { snSwInfo 12 } snSw8021qTagMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The Switch Group is configured with the IEEE802.1q Tagging mode either enabled or disabled and the default is disabled mode. enabled(1)...........activate IEEE802.1q Tagging mode. disabled(0)..........no IEEE802.1q Tagging." ::= { snSwInfo 13 } snSwGlobalStpMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Spanning Tree System Global Mode in the Switch Group can be set either enabled or disabled and the default is enabled mode. enabled(1)...........activate Spanning Tree disabled(0)..........no Spanning Tree" ::= { snSwInfo 14 } snSwIpMcastQuerierMode OBJECT-TYPE SYNTAX INTEGER { querier(1), nonQuerier(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The IP Multicast pruning mode is configured either Non-Querier or Querier mode and the default is querier mode. querier(1)...........when prunning traffic locally within the VLAN. nonQuerier(2)........when running with a multicast capable router in the network." ::= { snSwInfo 15 } snSwViolatorPortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number of the switch or router that received a violator packet. It is included in the locked address violation trap. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number (slot for chassis only)." ::= { snSwInfo 17 } snSwViolatorMacAddress OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The source address of the violator packet received by the switch or router. It is included in the locked address violation trap." ::= { snSwInfo 18 } snVLanGroupVlanMaxEntry OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of VLAN entries are allowed to configure." ::= { snSwInfo 19 } snSwEosBufferSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A specific buffer size for all the different EOS buffers." ::= { snSwInfo 20 } snVLanByPortEntrySize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The size of each VLAN table entry." ::= { snSwInfo 21 } snSwPortEntrySize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The size of each port table entry." ::= { snSwInfo 22 } snFdbStationEntrySize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The size of each Fdb station table entry." ::= { snSwInfo 23 } snPortStpEntrySize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The size of each port stp table entry." ::= { snSwInfo 24 } snSwEnableBridgeNewRootTrap OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the SNMP agent process is permitted to generate bridge new root traps." DEFVAL { enabled } ::= { snSwInfo 25 } snSwEnableBridgeTopoChangeTrap OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the SNMP agent process is permitted to generate bridge topology change traps." DEFVAL { enabled } ::= { snSwInfo 26 } snSwEnableLockedAddrViolationTrap OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the SNMP agent process is permitted to generate locked address violation traps." DEFVAL { enabled } ::= { snSwInfo 27 } snSwIpxL3SwMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The Switch Group is configured with the Layer3 IPX Switch mode either enabled or disabled and the default is disabled mode. enabled(1)...........activate Layer3 Switch disabled(0)..........disable Layer3 Switch" ::= { snSwInfo 28 } snVLanByIpSubnetMaxSubnets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of subnets for each IP VLAN." ::= { snSwInfo 29 } snVLanByIpxNetMaxNetworks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of networks for each IPX VLAN." ::= { snSwInfo 30 } snSwProtocolVLanMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "disabled(0) - represents system with Protocol VLAN disabled. enabled(1) - represents system with Protocol VLAN enabled (Layer3 VLAN)." ::= { snSwInfo 31 } snMacStationVLanId OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-write STATUS mandatory DESCRIPTION "This MAC Station VLAN ID index to the standard Forwarding Database for Transparent Bridge Table. (dot1dTpFdbTable). Since the dot1dTpFdbTable index is the MAC Address assigned to one of the ports in the bridge(VLAN) and each MAC address can be re-assigned to a different ports belonging to different bridges(VLANs), the snMacStationVLanId can be used by users to specify which bridge(VLAN) MAC Station information of the dot1dTpFdbTable users want to retrieve. If users do not specify the VLan ID in this MIB, the default VLAN (bridge) ID will be used when dot1dTpFdbTable is retrieved." ::= { snSwInfo 32 } snSwClearCounters OBJECT-TYPE SYNTAX INTEGER { valid(0), clear(1) } ACCESS read-write STATUS mandatory DESCRIPTION "valid(0) - a SNMP-GET of this mib shows that it is valid command to use. clear(1) - represents clear counter command of the following counters: Dot3, MIB2, IP and IPX counters for all ports." ::= { snSwInfo 33 } snSw8021qTagType OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The IEEE802.1q tag type embedded in the length/type field of an Ethernet packet. It specifies that the 2 octets after the length/type field in an Ethernet packet is the tag value." DEFVAL { 33024 } ::= { snSwInfo 34 } snSwBroadcastLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Limit the number of broadcast packets to forward out of the switch ports. This object specifies the number of broadcast packets per second. Setting a value of 0 to this object disables the limitation check." DEFVAL { 0 } ::= { snSwInfo 35 } snSwMaxMacFilterPerSystem OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of MAC Filters per system in the MAC Filter table." ::= { snSwInfo 36 } snSwMaxMacFilterPerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of MAC Filters per port in the Port MAC Access Filter table." ::= { snSwInfo 37 } snSwDefaultVLanId OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-write STATUS mandatory DESCRIPTION "The VLAN ID of the DEFAULT PORT-VLAN." ::= { snSwInfo 38 } snSwGlobalAutoNegotiate OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1), negFullAuto(2), other(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This feature only applies to Gigabit Ethernet ports. If set to disable(0), all Gigabit Ethernet ports will be put to non- negotiation mode. If set to enable(1), all Gigabit Ethernet ports will start auto-negotiation indefinitely until succeed. If set to negFullAuto(2), all Gigabit Ethernet ports will start with auto-negotiation, if the negotiation failed, then they will automatically switch to non-negotiation mode. Stackable products (except TurboIron 8) Gigabit Ethernet ports do not support negFullAuto(2). If the snSwPortInfoAutoNegotiate value of a port was not set to global, this global value does not apply to the negotiation mode of that port." DEFVAL { negFullAuto } ::= { snSwInfo 39 } snSwQosMechanism OBJECT-TYPE SYNTAX INTEGER { strict(0), weighted(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the qos mechanism is strict or weighted." DEFVAL { weighted } ::= { snSwInfo 40 } snSwSingleStpMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Single Spanning Tree System Mode in the Switch Group can be set either enabled or disabled and the default is disabled mode. enabled(1)...........activate Single Spanning Tree disabled(0)..........no Single Spanning Tree" ::= { snSwInfo 41 } snSwFastStpMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Fast Spanning Tree System Mode in the Switch Group can be set either enabled or disabled and the default is enabled mode. enabled(1)...........activate Fast Spanning Tree disabled(0)..........no Fast Spanning Tree" ::= { snSwInfo 42 } -- VLAN Layer 2 Switch VLAN By Port Information Table snVLanByPortTable OBJECT-TYPE SYNTAX SEQUENCE OF SnVLanByPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "If snSwGroupOperMode is configured as basic mode which is VLAN by Port, Layer2 switching, then this table is valid. Each VLAN switch port could have a number of VLAN IDs." ::= { snVLanInfo 1 } snVLanByPortEntry OBJECT-TYPE SYNTAX SnVLanByPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the VLAN By Port Information table. snVLanByPortVLanIndex = 1 and with snVLanByPortVLanId = 1 together implies all attributes applying to the Global switch group i.e. noVLan. A SNMP SET PDU for a row of the snVLanByPortTable requires the entired sequence of the MIB Objects in each snVLanByPortEntry stored in one PDU. Otherwise, GENERR return-value will be returned." INDEX { snVLanByPortVLanIndex } ::= { snVLanByPortTable 1 } SnVLanByPortEntry ::= SEQUENCE { snVLanByPortVLanIndex INTEGER, snVLanByPortVLanId INTEGER, snVLanByPortPortMask PortMask, snVLanByPortQos INTEGER, snVLanByPortStpMode INTEGER, snVLanByPortStpPriority INTEGER, snVLanByPortStpGroupMaxAge INTEGER, snVLanByPortStpGroupHelloTime INTEGER, snVLanByPortStpGroupForwardDelay INTEGER, snVLanByPortRowStatus INTEGER, snVLanByPortOperState INTEGER, snVLanByPortBaseNumPorts INTEGER, snVLanByPortBaseType INTEGER, snVLanByPortStpProtocolSpecification INTEGER, snVLanByPortStpMaxAge Timeout, snVLanByPortStpHelloTime Timeout, snVLanByPortStpHoldTime INTEGER, snVLanByPortStpForwardDelay Timeout, snVLanByPortStpTimeSinceTopologyChange TimeTicks, snVLanByPortStpTopChanges Counter, snVLanByPortStpRootCost INTEGER, snVLanByPortStpRootPort INTEGER, snVLanByPortStpDesignatedRoot BridgeId, snVLanByPortBaseBridgeAddress MacAddress, snVLanByPortVLanName DisplayString, snVLanByPortRouterIntf INTEGER, snVLanByPortChassisPortMask OCTET STRING } snVLanByPortVLanIndex OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The VLAN ID index must not be greater than the snVLanGroupVlanMaxEntry. Each VLAN Identifier can have a membership of multiple ports." ::= { snVLanByPortEntry 1 } snVLanByPortVLanId OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-write STATUS mandatory DESCRIPTION "The VLAN ID index to the VLAN By Port Info Table. Each VLAN Identifier can have a membership of multiple ports." ::= { snVLanByPortEntry 2 } snVLanByPortPortMask OBJECT-TYPE SYNTAX PortMask ACCESS read-write STATUS mandatory DESCRIPTION "The Standand-alone switch VLAN port membership. (It is obsoleted for Chassis Product)" ::= { snVLanByPortEntry 3 } snVLanByPortQos OBJECT-TYPE SYNTAX INTEGER { level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The Stand alone stackable switch VLAN Priority values are: low(0) -- low prority high(1) -- high prority. The BigIron switch VLAN Priority values are: level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) " ::= { snVLanByPortEntry 4 } snVLanByPortStpMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Spanning Tree Mode in the Switch Group can be set either enabled or disabled and the default is enabled mode. enabled(1)...........activate Spanning Tree disabled(0)..........no Spanning Tree" ::= { snVLanByPortEntry 5 } snVLanByPortStpPriority OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "dot1dStpPriority : The value of the write-able portion of the Stp ID, i.e., the first two octets of the (8 octet long) Bridge ID. The other (last) 6 octets of the Bridge ID are given by the value of the base bridge address - dot1dBaseBridgeAddress." ::= { snVLanByPortEntry 6 } snVLanByPortStpGroupMaxAge OBJECT-TYPE SYNTAX INTEGER (6..40) ACCESS read-write STATUS mandatory DESCRIPTION "dot1dStpBridgeMaxAge: From RFC1493(Bridge MIB). The value that all bridges use for MaxAge when this bridge is acting as the root. Note that 802.1D-1990 specifies that the range for this parameter is related to the value of dot1dStpBridgeHelloTime. The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds." ::= { snVLanByPortEntry 7 } snVLanByPortStpGroupHelloTime OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "dot1dStpBridgeHelloTime: From RFC1493(Bridge MIB). The value that all bridges use for HelloTime when this bridge is acting as the root. The granularity of this timer is specified by 802.1D- 1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds." ::= { snVLanByPortEntry 8 } snVLanByPortStpGroupForwardDelay OBJECT-TYPE SYNTAX INTEGER (4..30) ACCESS read-write STATUS mandatory DESCRIPTION "dot1dStpBridgeForwardDelay : From RFC1493(Bridge MIB). The value that all bridges use for ForwardDelay when this bridge is acting as the root. Note that 802.1D-1990 specifies that the range for this parameter is related to the value of dot1dStpBridgeMaxAge. The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds." ::= { snVLanByPortEntry 9 } snVLanByPortRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4), modify(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid" ::= { snVLanByPortEntry 10 } snVLanByPortOperState OBJECT-TYPE SYNTAX INTEGER { notActivated(0), activated(1) } ACCESS read-only STATUS mandatory DESCRIPTION "By default, this mode is set to notActivated(0). notActivated(0)...the VLAN entry is not activated and not in running mode. activated(1)......the VLAN entry is activated and in running mode" ::= { snVLanByPortEntry 11 } snVLanByPortBaseNumPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of ports controlled by this bridging entity." ::= { snVLanByPortEntry 12 } snVLanByPortBaseType OBJECT-TYPE SYNTAX INTEGER { unknown(1), transparent-only(2), sourceroute-only(3), srt(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates what type of bridging this bridge can perform. If a bridge is actually performing a certain type of bridging this will be indicated by entries in the port table for the given type." ::= { snVLanByPortEntry 13 } snVLanByPortStpProtocolSpecification OBJECT-TYPE SYNTAX INTEGER { unknown(1), decLb100(2), ieee8021d(3) } ACCESS read-only STATUS mandatory DESCRIPTION "An indication of what version of the Spanning Tree Protocol is being run. The value 'decLb100(2)' indicates the DEC LANbridge 100 Spanning Tree protocol. IEEE 802.1d implementations will return 'ieee8021d(3)'. If future versions of the IEEE Spanning Tree Protocol are released that are incompatible with the current version a new value will be defined." ::= { snVLanByPortEntry 14 } snVLanByPortStpMaxAge OBJECT-TYPE SYNTAX Timeout ACCESS read-only STATUS mandatory DESCRIPTION "dot1dStpMaxAge: From RFC1493(Bridge MIB). The maximum age of Spanning Tree Protocol information learned from the network on any port before it is discarded, in units of hundredths of a second. This is the actual value that this bridge is currently using." ::= { snVLanByPortEntry 15 } snVLanByPortStpHelloTime OBJECT-TYPE SYNTAX Timeout ACCESS read-only STATUS mandatory DESCRIPTION "dot1dStpHelloTime: From RFC1493(Bridge MIB). The amount of time between the transmission of Configuration bridge PDUs by this node on any port when it is the root of the spanning tree or trying to become so, in units of hundredths of a second. This is the actual value that this bridge is currently using." ::= { snVLanByPortEntry 16 } snVLanByPortStpHoldTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "dot1dStpHoldTime: From RFC1493(Bridge MIB). This time value determines the interval length during which no more than two Configuration bridge PDUs shall be transmitted by this node, in units of hundredths of a second." ::= { snVLanByPortEntry 17 } snVLanByPortStpForwardDelay OBJECT-TYPE SYNTAX Timeout ACCESS read-only STATUS mandatory DESCRIPTION "dot1dStpForwardDelay: From RFC1493(Bridge MIB). This time value, measured in units of hundredths of a second, controls how fast a port changes its spanning state when moving towards the Forwarding state. The value determines how long the port stays in each of the Listening and Learning states, which precede the Forwarding state. This value is also used, when a topology change has been detected and is underway, to age all dynamic entries in the Forwarding Database. [Note that this value is the one that this bridge is currently using, in contrast to dot1dStpBridgeForwardDelay which is the value that this bridge and all others would start using if/when this bridge were to become the root.]" ::= { snVLanByPortEntry 18 } snVLanByPortStpTimeSinceTopologyChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time (in hundredths of a second) since the last time a topology change was detected by the bridge entity." ::= { snVLanByPortEntry 19 } snVLanByPortStpTopChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of topology changes detected by this bridge since the management entity was last reset or initialized." ::= { snVLanByPortEntry 20 } snVLanByPortStpRootCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "dot1dStpRootCost: From RFC1493(Bridge MIB). The cost of the path to the root as seen from this bridge." ::= { snVLanByPortEntry 21 } snVLanByPortStpRootPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "dot1dStpRootPort: From RFC1493(Bridge MIB). The port number of the port which offers the lowest cost path from this bridge to the root bridge." ::= { snVLanByPortEntry 22 } snVLanByPortStpDesignatedRoot OBJECT-TYPE SYNTAX BridgeId ACCESS read-only STATUS mandatory DESCRIPTION "dot1dStpDesignatedRoot: From RFC1493(Bridge MIB). The bridge identifier of the root of the spanning tree as determined by the Spanning Tree Protocol as executed by this node. This value is used as the Root Identifier parameter in all Configuration Bridge PDUs originated by this node." ::= { snVLanByPortEntry 23 } snVLanByPortBaseBridgeAddress OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address used by this bridge when it must be referred to in a unique fashion. It is recommended that this be the numerically smallest MAC address of all ports that belong to this bridge. However it is only required to be unique. When concatenated with dot1dStpPriority a unique BridgeIdentifier is formed which is used in the Spanning Tree Protocol." ::= { snVLanByPortEntry 24 } snVLanByPortVLanName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "VLAN Community Name string." ::= { snVLanByPortEntry 25 } snVLanByPortRouterIntf OBJECT-TYPE SYNTAX INTEGER (1..60) ACCESS read-write STATUS mandatory DESCRIPTION "Optional: A virtual interface for router to the VLAN -- applied to router only. If a SNMP-Get value is zero, that means this object was not configured." ::= { snVLanByPortEntry 26 } snVLanByPortChassisPortMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-write STATUS mandatory DESCRIPTION "The Chassis VLAN switch port membership." ::= { snVLanByPortEntry 27 } -- VLAN by Protocol Configuration Table snVLanByProtocolTable OBJECT-TYPE SYNTAX SEQUENCE OF SnVLanByProtocolEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "." ::= { snVLanInfo 2 } snVLanByProtocolEntry OBJECT-TYPE SYNTAX SnVLanByProtocolEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the VLAN By Protocol Configuration table. " INDEX { snVLanByProtocolVLanId, snVLanByProtocolIndex } ::= { snVLanByProtocolTable 1 } SnVLanByProtocolEntry ::= SEQUENCE { snVLanByProtocolVLanId INTEGER, snVLanByProtocolIndex INTEGER, snVLanByProtocolDynamic INTEGER, snVLanByProtocolStaticMask PortMask, snVLanByProtocolExcludeMask PortMask, snVLanByProtocolRouterIntf INTEGER, snVLanByProtocolRowStatus INTEGER, snVLanByProtocolDynamicMask PortMask, snVLanByProtocolChassisStaticMask OCTET STRING, snVLanByProtocolChassisExcludeMask OCTET STRING, snVLanByProtocolChassisDynamicMask OCTET STRING, snVLanByProtocolVLanName DisplayString } snVLanByProtocolVLanId OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The VLAN ID index to both of the VLAN By Port Info Table and this table." ::= { snVLanByProtocolEntry 1 } snVLanByProtocolIndex OBJECT-TYPE SYNTAX INTEGER { ip(1), ipx(2), appleTalk(3), decNet(4), netBios(5), others(6) } ACCESS read-only STATUS mandatory DESCRIPTION " The following IP/IPX protocol VLAN types are operated in Layer3 VLAN such as : ip(1), ipx(2) The following are operated in Layer2 bridging such as: appleTalk(3), decNet(4), netBios(5), others(6) -- other protocols which are defined here. " ::= { snVLanByProtocolEntry 2 } snVLanByProtocolDynamic OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION " disabled(0) : disabled dynamic port inclusion - applied to switch only. enabled(1) : enabled dynamic port inclusion - applied to switch only. " ::= { snVLanByProtocolEntry 3 } snVLanByProtocolStaticMask OBJECT-TYPE SYNTAX PortMask ACCESS read-write STATUS mandatory DESCRIPTION "The Standand-alone switch Protocol VLAN port membership applied in static mode. (It is obsoleted for Chassis Product)" ::= { snVLanByProtocolEntry 4 } snVLanByProtocolExcludeMask OBJECT-TYPE SYNTAX PortMask ACCESS read-write STATUS mandatory DESCRIPTION "The Standand-alone switch Protocol VLAN port membership applied in exclusive mode. (It is obsoleted for Chassis Product)" ::= { snVLanByProtocolEntry 5 } snVLanByProtocolRouterIntf OBJECT-TYPE SYNTAX INTEGER (1..60) ACCESS read-write STATUS mandatory DESCRIPTION "Optional: A virtual interface for router to the VLAN -- applied to router only. If a SNMP-Get value is zero, that means this object was not configured." ::= { snVLanByProtocolEntry 6 } snVLanByProtocolRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4), modify(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid" ::= { snVLanByProtocolEntry 7 } snVLanByProtocolDynamicMask OBJECT-TYPE SYNTAX PortMask ACCESS read-only STATUS mandatory DESCRIPTION "The Standand-alone switch Protocol VLAN active port membership. (It is obsoleted for Chassis Product)" ::= { snVLanByProtocolEntry 8 } snVLanByProtocolChassisStaticMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-write STATUS mandatory DESCRIPTION "The Chassis Protocol VLAN port membership applied in static mode." ::= { snVLanByProtocolEntry 9 } snVLanByProtocolChassisExcludeMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-write STATUS mandatory DESCRIPTION "The Chassis Protocol VLAN port membership applied in exclusive mode." ::= { snVLanByProtocolEntry 10 } snVLanByProtocolChassisDynamicMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-only STATUS mandatory DESCRIPTION "The Chassis Protocol VLAN active port membership." ::= { snVLanByProtocolEntry 11 } snVLanByProtocolVLanName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "VLAN Community Name string." ::= { snVLanByProtocolEntry 12 } -- VLAN By IP Subnet Configuration Table snVLanByIpSubnetTable OBJECT-TYPE SYNTAX SEQUENCE OF SnVLanByIpSubnetEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the VLAN By IPX Network Number Table." ::= { snVLanInfo 3 } snVLanByIpSubnetEntry OBJECT-TYPE SYNTAX SnVLanByIpSubnetEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the VLAN By IP Subnet Configuration table. " INDEX { snVLanByIpSubnetVLanId, snVLanByIpSubnetIpAddress, snVLanByIpSubnetSubnetMask } ::= { snVLanByIpSubnetTable 1 } SnVLanByIpSubnetEntry ::= SEQUENCE { snVLanByIpSubnetVLanId INTEGER, snVLanByIpSubnetIpAddress IpAddress, snVLanByIpSubnetSubnetMask IpAddress, snVLanByIpSubnetDynamic INTEGER, snVLanByIpSubnetStaticMask PortMask, snVLanByIpSubnetExcludeMask PortMask, snVLanByIpSubnetRouterIntf INTEGER, snVLanByIpSubnetRowStatus INTEGER, snVLanByIpSubnetDynamicMask PortMask, snVLanByIpSubnetChassisStaticMask OCTET STRING, snVLanByIpSubnetChassisExcludeMask OCTET STRING, snVLanByIpSubnetChassisDynamicMask OCTET STRING, snVLanByIpSubnetVLanName DisplayString } snVLanByIpSubnetVLanId OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The VLAN ID index to both of the VLAN By Port Info Table and this table." ::= { snVLanByIpSubnetEntry 1 } snVLanByIpSubnetIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Subnet IP address." ::= { snVLanByIpSubnetEntry 2 } snVLanByIpSubnetSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Subnet mask associated with the Subnet IP address." ::= { snVLanByIpSubnetEntry 3 } snVLanByIpSubnetDynamic OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION " disabled(0) : disabled dynamic port inclusion - applied to switch only. enabled(1) : enabled dynamic port inclusion - applied to switch only. " ::= { snVLanByIpSubnetEntry 4 } snVLanByIpSubnetStaticMask OBJECT-TYPE SYNTAX PortMask ACCESS read-write STATUS mandatory DESCRIPTION "The Standand-alone switch VLAN By Subnet port membership applied in static mode. (It is obsoleted for Chassis Product)" ::= { snVLanByIpSubnetEntry 5 } snVLanByIpSubnetExcludeMask OBJECT-TYPE SYNTAX PortMask ACCESS read-write STATUS mandatory DESCRIPTION "The Standand-alone switch VLAN By Subnet port membership applied in exclusive mode. (It is obsoleted for Chassis Product)" ::= { snVLanByIpSubnetEntry 6 } snVLanByIpSubnetRouterIntf OBJECT-TYPE SYNTAX INTEGER (1..60) ACCESS read-write STATUS mandatory DESCRIPTION "Optional: A virtual interface for router to the VLAN -- applied to router only. If a SNMP-Get value is zero, that means this object was not configured." ::= { snVLanByIpSubnetEntry 7 } snVLanByIpSubnetRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4), modify(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid" ::= { snVLanByIpSubnetEntry 8 } snVLanByIpSubnetDynamicMask OBJECT-TYPE SYNTAX PortMask ACCESS read-only STATUS mandatory DESCRIPTION "The Standand-alone switch VLAN By Subnet active port membership. (It is obsoleted for Chassis Product)" ::= { snVLanByIpSubnetEntry 9 } snVLanByIpSubnetChassisStaticMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-write STATUS mandatory DESCRIPTION "The Chassis VLAN By Subnet port membership applied in static mode." ::= { snVLanByIpSubnetEntry 10 } snVLanByIpSubnetChassisExcludeMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-write STATUS mandatory DESCRIPTION "The Chassis VLAN By Subnet port membership applied in exclusive mode." ::= { snVLanByIpSubnetEntry 11 } snVLanByIpSubnetChassisDynamicMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-only STATUS mandatory DESCRIPTION "The Chassis VLAN By Subnet active port membership." ::= { snVLanByIpSubnetEntry 12 } snVLanByIpSubnetVLanName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "VLAN Community Name string." ::= { snVLanByIpSubnetEntry 13 } -- VLAN By IPX Net Configuration Table snVLanByIpxNetTable OBJECT-TYPE SYNTAX SEQUENCE OF SnVLanByIpxNetEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the VLAN By IPX Network Number Table." ::= { snVLanInfo 4 } snVLanByIpxNetEntry OBJECT-TYPE SYNTAX SnVLanByIpxNetEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the VLAN By Ipx Network Number Configuration table. " INDEX { snVLanByIpxNetVLanId, snVLanByIpxNetNetworkNum, snVLanByIpxNetFrameType } ::= { snVLanByIpxNetTable 1 } SnVLanByIpxNetEntry ::= SEQUENCE { snVLanByIpxNetVLanId INTEGER, snVLanByIpxNetNetworkNum OCTET STRING, snVLanByIpxNetFrameType INTEGER, snVLanByIpxNetDynamic INTEGER, snVLanByIpxNetStaticMask PortMask, snVLanByIpxNetExcludeMask PortMask, snVLanByIpxNetRouterIntf INTEGER, snVLanByIpxNetRowStatus INTEGER, snVLanByIpxNetDynamicMask PortMask, snVLanByIpxNetChassisStaticMask OCTET STRING, snVLanByIpxNetChassisExcludeMask OCTET STRING, snVLanByIpxNetChassisDynamicMask OCTET STRING, snVLanByIpxNetVLanName DisplayString } snVLanByIpxNetVLanId OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The VLAN ID index to both of the VLAN By Port Info Table and this table." ::= { snVLanByIpxNetEntry 1 } snVLanByIpxNetNetworkNum OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "IPX Network Number." ::= { snVLanByIpxNetEntry 2 } snVLanByIpxNetFrameType OBJECT-TYPE SYNTAX INTEGER { notApplicable(0), ipxEthernet8022(1), ipxEthernet8023(2), ipxEthernetII(3), ipxEthernetSnap(4) } ACCESS read-only STATUS mandatory DESCRIPTION " The following IPX Frame types are operated in Layer3 VLAN such as : ipxEthernet8022(1), ipxEthernet8023(2), ipxEthernetII(3), ipxEthernetSnap(4). choose notApplicable(0) for other protocols. Note: Each Network Number can be assigned with one unique Frame type; Otherwise, a SNMP-SET error will be returned." ::= { snVLanByIpxNetEntry 3 } snVLanByIpxNetDynamic OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION " disabled(0) : disabled dynamic port inclusion - applied to switch only. enabled(1) : enabled dynamic port inclusion - applied to switch only. " ::= { snVLanByIpxNetEntry 4 } snVLanByIpxNetStaticMask OBJECT-TYPE SYNTAX PortMask ACCESS read-write STATUS mandatory DESCRIPTION "The VLAN By IPX network port membership applied in static mode." ::= { snVLanByIpxNetEntry 5 } snVLanByIpxNetExcludeMask OBJECT-TYPE SYNTAX PortMask ACCESS read-write STATUS mandatory DESCRIPTION "The VLAN By IPX network port membership applied in exclusive mode." ::= { snVLanByIpxNetEntry 6 } snVLanByIpxNetRouterIntf OBJECT-TYPE SYNTAX INTEGER (1..60) ACCESS read-write STATUS mandatory DESCRIPTION "Optional: A virtual interface for router to the VLAN -- applied to router only. If a SNMP-Get value is zero, that means this object was not configured." ::= { snVLanByIpxNetEntry 7 } snVLanByIpxNetRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4), modify(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid" ::= { snVLanByIpxNetEntry 8 } snVLanByIpxNetDynamicMask OBJECT-TYPE SYNTAX PortMask ACCESS read-only STATUS mandatory DESCRIPTION "The VLAN By IPX network active port membership." ::= { snVLanByIpxNetEntry 9 } snVLanByIpxNetChassisStaticMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-write STATUS mandatory DESCRIPTION "The Chassis VLAN By IPX network port membership applied in static mode." ::= { snVLanByIpxNetEntry 10 } snVLanByIpxNetChassisExcludeMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-write STATUS mandatory DESCRIPTION "The Chassis VLAN By IPX network port membership applied in exclusive mode." ::= { snVLanByIpxNetEntry 11 } snVLanByIpxNetChassisDynamicMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-only STATUS mandatory DESCRIPTION "The Chassis VLAN By IPX network active port membership." ::= { snVLanByIpxNetEntry 12 } snVLanByIpxNetVLanName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "VLAN Community Name string." ::= { snVLanByIpxNetEntry 13 } -- VLAN By AppleTalk Cable Configuration Table snVLanByATCableTable OBJECT-TYPE SYNTAX SEQUENCE OF SnVLanByATCableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A Table Of VLAN By AppleTalk Network Number." ::= { snVLanInfo 5 } snVLanByATCableEntry OBJECT-TYPE SYNTAX SnVLanByATCableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the AppleTalk Cable VLAN table." INDEX {snVLanByATCableVLanId, snVLanByATCableIndex} ::= { snVLanByATCableTable 1 } SnVLanByATCableEntry ::= SEQUENCE { snVLanByATCableVLanId INTEGER, snVLanByATCableIndex INTEGER, snVLanByATCableRouterIntf INTEGER, snVLanByATCableRowStatus INTEGER, snVLanByATCableChassisStaticMask OCTET STRING, snVLanByATCableVLanName DisplayString } snVLanByATCableVLanId OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The VLAN ID of a PORT VLAN of which the AppleTalk Cable VLAN was attaching to." ::= { snVLanByATCableEntry 1 } snVLanByATCableIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "AppleTalk Cable VLAN index number." ::= { snVLanByATCableEntry 2 } snVLanByATCableRouterIntf OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "A virtual router interface to the AppleTalk Cable VLAN, only router products accept the SNMP-SET operation. The value zero indicates that virtual router interface was not configured." ::= { snVLanByATCableEntry 3 } snVLanByATCableRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4), modify(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid" ::= { snVLanByATCableEntry 4 } snVLanByATCableChassisStaticMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) ACCESS read-write STATUS mandatory DESCRIPTION "A list of ports which are statically configured to become port members of a VLAN." ::= { snVLanByATCableEntry 5 } snVLanByATCableVLanName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "VLAN Name string." ::= { snVLanByATCableEntry 6 } -- Switch Port Information Group snSwPortInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SnSwPortInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A specific snSwPortInfo group consists of a number of switch ports. " ::= { snSwPortInfo 1 } snSwPortInfoEntry OBJECT-TYPE SYNTAX SnSwPortInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the snSwPortInfo table indicates the configuration on a specified port. A SNMP SET PDU for a row of the snSwPortInfoTable requires the entired sequence of the MIB Objects in each snSwPortInfoEntry stored in one PDU. Otherwise, GENERR return-value will be returned." INDEX { snSwPortInfoPortNum } ::= { snSwPortInfoTable 1 } SnSwPortInfoEntry ::= SEQUENCE { snSwPortInfoPortNum INTEGER, snSwPortInfoMonitorMode INTEGER, snSwPortInfoTagType INTEGER, snSwPortInfoChnMode INTEGER, snSwPortInfoSpeed INTEGER, snSwPortInfoMediaType INTEGER, snSwPortInfoConnectorType INTEGER, snSwPortInfoAdminStatus INTEGER, snSwPortInfoLinkStatus INTEGER, snSwPortInfoPortQos INTEGER, snSwPortInfoPhysAddress PhysAddress, snSwPortStatsInFrames Counter, snSwPortStatsOutFrames Counter, snSwPortStatsAlignErrors Counter, snSwPortStatsFCSErrors Counter, snSwPortStatsMultiColliFrames Counter, snSwPortStatsFrameTooLongs Counter, snSwPortStatsTxColliFrames Counter, snSwPortStatsRxColliFrames Counter, snSwPortStatsFrameTooShorts Counter, snSwPortLockAddressCount INTEGER, snSwPortStpPortEnable INTEGER, snSwPortDhcpGateListId INTEGER, snSwPortName DisplayString, snSwPortStatsInBcastFrames Counter, snSwPortStatsOutBcastFrames Counter, snSwPortStatsInMcastFrames Counter, snSwPortStatsOutMcastFrames Counter, snSwPortStatsInDiscard Counter, snSwPortStatsOutDiscard Counter, snSwPortStatsMacStations INTEGER, snSwPortCacheGroupId INTEGER, snSwPortTransGroupId INTEGER, snSwPortInfoAutoNegotiate INTEGER, snSwPortInfoFlowControl INTEGER, snSwPortInfoGigType INTEGER, snSwPortStatsLinkChange Counter, snSwPortIfIndex INTEGER, snSwPortDescr DisplayString, snSwPortInOctets OCTET STRING, snSwPortOutOctets OCTET STRING, snSwPortStatsInBitsPerSec Gauge, snSwPortStatsOutBitsPerSec Gauge, snSwPortStatsInPktsPerSec Gauge, snSwPortStatsOutPktsPerSec Gauge, snSwPortStatsInUtilization INTEGER (0..10000), snSwPortStatsOutUtilization INTEGER (0..10000), snSwPortFastSpanPortEnable INTEGER, snSwPortFastSpanUplinkEnable INTEGER, snSwPortVlanId INTEGER, snSwPortRouteOnly INTEGER } snSwPortInfoPortNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port index. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number (slot for chassis only)." ::= { snSwPortInfoEntry 1 } snSwPortInfoMonitorMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), input(1), output(2), both(3) } ACCESS read-write STATUS mandatory DESCRIPTION "A monitoring port is selected and its traffic will be analyzed if the mode is not disabled(0), which is the default mode. The values are: disabled(0) -- No traffic monitoring input(1) -- traffic monitoring is activated on packets received output(2) -- traffic monitoring is activated on packets transmitted both(3) -- traffic monitoring is activated on packets received and transmitted." ::= { snSwPortInfoEntry 2 } snSwPortInfoTagType OBJECT-TYPE SYNTAX INTEGER { tagged(1), untagged(2), auto(3), disabled(4) } ACCESS read-write STATUS mandatory DESCRIPTION "For tagged port, we could have multiple VLANs per port. For untagged port or auto port, there is only one VLAN ID per port." ::= { snSwPortInfoEntry 3 } snSwPortInfoChnMode OBJECT-TYPE SYNTAX INTEGER { none(0), halfDuplex(1), fullDuplex(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The port can be configured to operate in either half or full duplex mode. The values are: halfDuplex(1)...half duplex mode fullDuplex(2)...full duplex mode The read-back channel status from hardware are: none(0).........link down or port disabled. halfDuplex(1)...half duplex mode fullDuplex(2)...full duplex mode The port media type (expansion or regular) and port link type (trunk or feeder) determine value of this object. The port can not set to half duplex mode if the port connect mode is m200e(4). However, the value of this parameter may be automatically set whenever the expansion port is connected (e.g. cascade connecting device)." ::= { snSwPortInfoEntry 4 } snSwPortInfoSpeed OBJECT-TYPE SYNTAX INTEGER { none(0), sAutoSense(1), s10M(2), s100M(3), s1G(4), s45M(5), s155M(6) } ACCESS read-write STATUS mandatory DESCRIPTION "The speed configuration for a port. The values are: none(0)..........link down or no traffic. sAutoSense(1)....Auto-sensing 10 or 100Mbits. s10M(2)..........10Mbits per second. s100M(3).........100Mbits per second. s1G(4)...........1Gbits per second. s45M(5)..........45Mbits per second (T3) (for expansion board only). s155M(6).........155Mbits per second (ATM) (for expansion board only). The read-back hardware status are the following: none(0)..........link down or no traffic. s10M(2)..........10Mbits per second. s100M(3).........100Mbits per second. s1G(4)...........1Gbits per second. s45M(5)..........45Mbits per second (T3) (for expansion board only). s155M(6).........155Mbits per second (ATM) (for expansion board only). The port media type (expansion or regular) and port link type (trunk or feeder) determine whether this object can be written and the valid values. It is not allowed to change speed for trunks ports. For expansion ports, all of the above speed can be set. However, the value of this parameter may be automatically set whenever the expansion port is connected (e.g. cascade connecting device)." ::= { snSwPortInfoEntry 5 } snSwPortInfoMediaType OBJECT-TYPE SYNTAX INTEGER { other(1), m100BaseTX(2), m100BaseFX(3), m1000BaseFX(4), mT3(5), m155ATM(6), m1000BaseTX(7), m622ATM(8), m155POS(9), m622POS(10) } ACCESS read-only STATUS mandatory DESCRIPTION "The media type for the port. The values are: other(1).........other or unknown media. m100BaseTX(2)....100Mbits per second copper. m100BaseFX(3)....100Mbits per second fiber. m1000BaseFX(4)...1Gbits per second fiber. mT3(5)...........45Mbits per second (T3). m155ATM(6).......155Mbits per second (ATM). m1000BaseTX(7)...1Gbits per second copper. m622ATM(8).......622Mbits per second (ATM). m155POS(9).......155Mbits per second (POS). m622POS(10)......622Mbits per second (POS)." ::= { snSwPortInfoEntry 6 } snSwPortInfoConnectorType OBJECT-TYPE SYNTAX INTEGER { other(1), copper(2), fiber(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of connector that the port offers. The values are: other(1)...........other or unknown connector copper(2)..........Copper connector fiber(3)...........Fiber connector This describes the physical connector type" ::= { snSwPortInfoEntry 7 } snSwPortInfoAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- ready to pass packets down(2), testing(3) -- in some test mode } ACCESS read-write STATUS mandatory DESCRIPTION "The desired state of all ports. The testing(3) state indicates that no operational packets can be passed. (same as ifAdminStatus in MIB-II)" ::= { snSwPortInfoEntry 8 } snSwPortInfoLinkStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- ready to pass packets down(2), testing(3) -- in some test mode } ACCESS read-only STATUS mandatory DESCRIPTION "The current operational state of the interface. The testing(3) state indicates that no operational packets can be passed. (same as ifOperStatus in MIB-II)" ::= { snSwPortInfoEntry 9 } snSwPortInfoPortQos OBJECT-TYPE SYNTAX INTEGER { level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The Stand alone stackable switch Port Qos Priority values are: low(0) -- low prority high(1) -- high prority. The BigIron Port Qos Priority values are: level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) " ::= { snSwPortInfoEntry 10 } snSwPortInfoPhysAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The port physical address. The physical address represents the switch port." ::= { snSwPortInfoEntry 11 } snSwPortStatsInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets received on the interface." ::= { snSwPortInfoEntry 12 } snSwPortStatsOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of packets transmitted out of the interface." ::= { snSwPortInfoEntry 13 } snSwPortStatsAlignErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "dot3StatsAlignmentErrors : A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check. The count represented by an instance of this object is incremented when the alignmentError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC." ::= { snSwPortInfoEntry 14 } snSwPortStatsFCSErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "dot3StatsFCSErrors : A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check. The count represented by an instance of this object is incremented when the frameCheckError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC." ::= { snSwPortInfoEntry 15 } snSwPortStatsMultiColliFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "dot3StatsMultipleCollisionFrames : A count of successfully transmitted frames on a particular interface for which transmission is inhibited by more than one collision. A frame that is counted by an instance of this object is also counted by the corresponding instance of either the ifOutUcastPkts, ifOutMulticastPkts, or ifOutBroadcastPkts, and is not counted by the corresponding instance of the dot3StatsSingleCollisionFrames object." ::= { snSwPortInfoEntry 16 } snSwPortStatsFrameTooLongs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "dot3StatsFrameTooLongs : A count of frames received on a particular interface that exceed the maximum permitted frame size. The count represented by an instance of this object is incremented when the frameTooLong status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtain are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC." ::= { snSwPortInfoEntry 17 } snSwPortStatsTxColliFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of successfully transmitted frames on a particular interface for which transmission is inhibited by more than one collision. A frame that is counted by a combination of both dot3StatsSingleCollisionFrames and dot3StatsMultipleCollisionFrames objects." ::= { snSwPortInfoEntry 18 } snSwPortStatsRxColliFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of successfully received frames on a particular interface for which transmission is inhibited by more than one collision. This object is not specified in dot3 but it has the same functionarity as snSwPortStatsTxColliFrames." ::= { snSwPortInfoEntry 19 } snSwPortStatsFrameTooShorts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION " A count of frames received on a particular interface that below the minimum permitted frame size." ::= { snSwPortInfoEntry 20 } snSwPortLockAddressCount OBJECT-TYPE SYNTAX INTEGER (0..2048) ACCESS read-write STATUS mandatory DESCRIPTION "The number of source MAC addresses are allowed for a port. Writing 0 to this object will allow any number of addresses." DEFVAL { 8 } ::= { snSwPortInfoEntry 21 } snSwPortStpPortEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The enabled/disabled status of the port." REFERENCE "IEEE 802.1D-1990: Section 4.5.5.2, dot1dStpPortEnable" ::= { snSwPortInfoEntry 22 } snSwPortDhcpGateListId OBJECT-TYPE SYNTAX INTEGER (0..32) ACCESS read-write STATUS mandatory DESCRIPTION "The ID for a DHCP gateway list entry relative to this switch port. 0 = unset or no assigned ID" ::= { snSwPortInfoEntry 23 } snSwPortName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "Port Name string." ::= { snSwPortInfoEntry 24 } snSwPortStatsInBcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of broadcast packets received on the interface." ::= { snSwPortInfoEntry 25 } snSwPortStatsOutBcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of broadcast packets transmitted out of the interface." ::= { snSwPortInfoEntry 26 } snSwPortStatsInMcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of multicast packets received on the interface." ::= { snSwPortInfoEntry 27 } snSwPortStatsOutMcastFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of multicast packets transmitted out of the interface." ::= { snSwPortInfoEntry 28 } snSwPortStatsInDiscard OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space." ::= { snSwPortInfoEntry 29 } snSwPortStatsOutDiscard OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space." ::= { snSwPortInfoEntry 30 } snSwPortStatsMacStations OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of MAC Stations connected to the interface." ::= { snSwPortInfoEntry 31 } snSwPortCacheGroupId OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Cache Group ID for the interface." ::= { snSwPortInfoEntry 32 } snSwPortTransGroupId OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Transparent Group ID for the interface." ::= { snSwPortInfoEntry 33 } snSwPortInfoAutoNegotiate OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1), negFullAuto(2), global(3), other(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This feature only applies to Gigabit Ethernet ports. If set to disable(0), port will be put to non-negotiation mode. If set to enable(1), port will start auto-negotiation indefinitely until succeed. If set to negFullAuto(2), the port will start with auto- negotiation, if the negotiation failed, then it will automatically switch to non-negotiation mode. Stackable products (except TurboIron 8) Gigabit Ethernet ports do not support negFullAuto(2). If set to global(3), port negotiation mode follows the value of snSwGlobalAutoNegotiate. Non-Gigabit Ethernet port returns the value other(4)." DEFVAL { global } ::= { snSwPortInfoEntry 34 } snSwPortInfoFlowControl OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disbale port flow control." DEFVAL { enabled } ::= { snSwPortInfoEntry 35 } snSwPortInfoGigType OBJECT-TYPE SYNTAX INTEGER { m1000BaseSX(0), m1000BaseLX(1), m1000BaseLH(2), notApplicable(255) } ACCESS read-only STATUS mandatory DESCRIPTION "The media type for the port. The values are: m1000BaseSX(0)....1Gbits per second fiber, with a short wavelength transceiver. m1000BaseLX(1)....1Gbits per second fiber, with a long wavelength transceiver (3km). m1000BaseLH(2)....1Gbits per second fiber, with a special wavelength transceiver (50km). notApplicable(255)....a non-gigabit port." ::= { snSwPortInfoEntry 36 } snSwPortStatsLinkChange OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of link state change of the interface." ::= { snSwPortInfoEntry 37 } snSwPortIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "In order to identify a particular interface, this object shall identify the instance of the ifIndex object, defined in RFC 1213 and RFC 1573." ::= { snSwPortInfoEntry 38 } snSwPortDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A textual string containing the slot/port information about the interface." ::= { snSwPortInfoEntry 39 } snSwPortInOctets OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets received on the interface, including framing characters. This object is a 64-bit counter of the ifInOctets object, defined in RFC 1213. The octet string is in big-endian byte order." ::= { snSwPortInfoEntry 40 } snSwPortOutOctets OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit counter of the ifOutOctets object, defined in RFC 1213. The octet string is in big-endian byte order." ::= { snSwPortInfoEntry 41 } snSwPortStatsInBitsPerSec OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of bits per second received on the interface over a 5 minutes interval." ::= { snSwPortInfoEntry 42 } snSwPortStatsOutBitsPerSec OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of bits per second transmitted out of the interface over a 5 minutes interval." ::= { snSwPortInfoEntry 43 } snSwPortStatsInPktsPerSec OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets per second received on the interface over a 5 minutes interval." ::= { snSwPortInfoEntry 44 } snSwPortStatsOutPktsPerSec OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets per second transmitted out of the interface over a 5 minutes interval." ::= { snSwPortInfoEntry 45 } snSwPortStatsInUtilization OBJECT-TYPE SYNTAX INTEGER (0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The input network utilization in hundredths of a percent over a 5 minutes interval." ::= { snSwPortInfoEntry 46 } snSwPortStatsOutUtilization OBJECT-TYPE SYNTAX INTEGER (0..10000) ACCESS read-only STATUS mandatory DESCRIPTION "The output network utilization in hundredths of a percent over a 5 minutes interval." ::= { snSwPortInfoEntry 47 } snSwPortFastSpanPortEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The enabled/disabled fast span port status of the port." ::= { snSwPortInfoEntry 48 } snSwPortFastSpanUplinkEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The enabled/disabled fast span uplink status of the port." ::= { snSwPortInfoEntry 49 } snSwPortVlanId OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The ID of a VLAN of which this port is a member. Port must be untagged. For tagged port which belongs to multiple VLANs, this object return 0 which is an invalid VLAN ID value." ::= { snSwPortInfoEntry 50 } snSwPortRouteOnly OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable L2 switching of a routing switch port. By default, the routing switch performs routing first. If routing failed, it performs switching. Enable route only instrcuts the routing switch to perform routing only. For a L2 switching only product, reading this object always return 'disabled', writing 'enabled' to this object takes no effect." DEFVAL { disabled } ::= { snSwPortInfoEntry 51 } -- Forwarding Database Group -- -- This group contains information relevant to -- the forwarding database in the system. -- The Forward Database Static Table Information -- -- This table contains all MAC addresses in the system. Static -- stations may be configured. snFdbTable OBJECT-TYPE SYNTAX SEQUENCE OF SnFdbEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains snFdb information for each station known to the system, one entry per station." ::= { snFdbInfo 1 } snFdbEntry OBJECT-TYPE SYNTAX SnFdbEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry represents the information of a static MAC station." INDEX { snFdbStationIndex } ::= { snFdbTable 1 } SnFdbEntry ::= SEQUENCE { snFdbStationIndex INTEGER, snFdbStationAddr PhysAddress, snFdbStationPort INTEGER, snFdbVLanId INTEGER, snFdbStationQos INTEGER, snFdbStationType INTEGER, snFdbRowStatus INTEGER } snFdbStationIndex OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-only STATUS mandatory DESCRIPTION "The FDB Station index to the Fdb Station Table." ::= { snFdbEntry 1 } snFdbStationAddr OBJECT-TYPE SYNTAX PhysAddress ACCESS read-write STATUS mandatory DESCRIPTION "The snFdbs physical address. The physical address represents a MAC Station." ::= { snFdbEntry 2 } snFdbStationPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Station slot/port number. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number (slot for chassis only)." ::= { snFdbEntry 3 } snFdbVLanId OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The Station VLan ID." ::= { snFdbEntry 4 } snFdbStationQos OBJECT-TYPE SYNTAX INTEGER { level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The Stand alone stackable station Qos Priority values are: low(0) -- low prority high(1) -- high prority. The BigIron switch station Priority values are: level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) " ::= { snFdbEntry 5 } snFdbStationType OBJECT-TYPE SYNTAX INTEGER { notSupported(0), host(1), router(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The station type values are: notSupported -- a read value only : this product does not support MultiLayer Switching. host -- any MAC station. router -- a router-typed station." ::= { snFdbEntry 6 } snFdbRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid" ::= { snFdbEntry 7 } -- Port STP Configuration Group snPortStpTable OBJECT-TYPE SYNTAX SEQUENCE OF SnPortStpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A specific snPortStpTable consists of a number of switch ports. This table only exists if only if snVLanByPortTable exists and snVLanByPortStpMode is enabled for each VLAN." ::= { snPortStpInfo 1 } snPortStpEntry OBJECT-TYPE SYNTAX SnPortStpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the snPortStpTable indicates the configuration on a specified port. A SNMP SET PDU for a row of the snPortStpTable requires the entired sequence of the MIB Objects in each snPortStpEntry stored in one PDU. Otherwise, GENERR return-value will be returned." INDEX { snPortStpVLanId, snPortStpPortNum } ::= { snPortStpTable 1 } SnPortStpEntry ::= SEQUENCE { snPortStpVLanId INTEGER, snPortStpPortNum INTEGER, snPortStpPortPriority INTEGER, snPortStpPathCost INTEGER, snPortStpOperState INTEGER, snPortStpPortEnable INTEGER, snPortStpPortForwardTransitions Counter, snPortStpPortState INTEGER, snPortStpPortDesignatedCost INTEGER, snPortStpPortDesignatedRoot BridgeId, snPortStpPortDesignatedBridge BridgeId, snPortStpPortDesignatedPort OCTET STRING } snPortStpVLanId OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The VLAN ID of the VLAN switch community." ::= { snPortStpEntry 1 } snPortStpPortNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number of the Switch. The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number (slot for chassis only)." ::= { snPortStpEntry 2 } snPortStpPortPriority OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The value of the priority field which is contained in the first (in network byte order) octet of the (2 octet long) Port ID. The other octet of the Port ID is given by the value of dot1dStpPort." ::= { snPortStpEntry 3 } snPortStpPathCost OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "dot1dStpPortPathCost : The contribution of this port to the path cost of paths towards the spanning tree root which include this port. 802.1D-1990 recommends that the default value of this parameter be in inverse proportion to the speed of the attached LAN. Writing value zero to this object sets path cost to a default value which automatically changes according to port speed. Reading value zero indicates an unknown path cost value because port speed cannot be determined due to speed auto sense in progress." ::= { snPortStpEntry 4 } snPortStpOperState OBJECT-TYPE SYNTAX INTEGER { notActivated(0), activated(1) } ACCESS read-only STATUS mandatory DESCRIPTION "By default, this mode is set to notActivated(0). notActivated(0)...the Port STP entry is not activated and not in running mode. activated(1)......the Port STP entry is activated and in running mode" ::= { snPortStpEntry 5 } snPortStpPortEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS not-accessible STATUS mandatory DESCRIPTION "The enabled/disabled status of the port." ::= { snPortStpEntry 6 } snPortStpPortForwardTransitions OBJECT-TYPE SYNTAX Counter ACCESS not-accessible STATUS mandatory DESCRIPTION "The number of times this port has transitioned from the Learning state to the Forwarding state." ::= { snPortStpEntry 7 } snPortStpPortState OBJECT-TYPE SYNTAX INTEGER { disabled(1), blocking(2), listening(3), learning(4), forwarding(5), broken(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The port's current state as defined by application of the Spanning Tree Protocol. This state controls what action a port takes on reception of a frame. If the bridge has detected a port that is malfunctioning it will place that port into the broken(6) state. For ports which are disabled (see dot1dStpPortEnable), this object will have a value of disabled(1)." ::= { snPortStpEntry 8 } snPortStpPortDesignatedCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The path cost of the Designated Port of the segment connected to this port. This value is compared to the Root Path Cost field in received bridge PDUs." ::= { snPortStpEntry 9 } snPortStpPortDesignatedRoot OBJECT-TYPE SYNTAX BridgeId ACCESS read-only STATUS mandatory DESCRIPTION "The unique Bridge Identifier of the Bridge recorded as the Root in the Configuration BPDUs transmitted by the Designated Bridge for the segment to which the port is attached." ::= { snPortStpEntry 10 } snPortStpPortDesignatedBridge OBJECT-TYPE SYNTAX BridgeId ACCESS read-only STATUS mandatory DESCRIPTION "The Bridge Identifier of the bridge which this port considers to be the Designated Bridge for this port's segment." ::= { snPortStpEntry 11 } snPortStpPortDesignatedPort OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "The Port Identifier of the port on the Designated Bridge for this port's segment." ::= { snPortStpEntry 12 } -- Trunk Port Configuration Group snTrunkTable OBJECT-TYPE SYNTAX SEQUENCE OF SnTrunkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A specific snTrunkTable consists of a number of Trunk port-mask." ::= { snTrunkInfo 1 } snTrunkEntry OBJECT-TYPE SYNTAX SnTrunkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the snTrunkTable indicates the configuration on a specified Trunk port membership." INDEX { snTrunkIndex } ::= { snTrunkTable 1 } SnTrunkEntry ::= SEQUENCE { snTrunkIndex INTEGER, snTrunkPortMask PortMask, snTrunkType INTEGER } snTrunkIndex OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-only STATUS mandatory DESCRIPTION "The number of the trunk entries can be configured." ::= { snTrunkEntry 1 } snTrunkPortMask OBJECT-TYPE SYNTAX PortMask ACCESS read-write STATUS mandatory DESCRIPTION "Trunk membership of the Switch." ::= { snTrunkEntry 2 } snTrunkType OBJECT-TYPE SYNTAX INTEGER { switch(1), server(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The trunk connection type which specifies what device the trunk ports are connected to." ::= { snTrunkEntry 3 } -- Multi-slot Trunk Port Configuration Group snMSTrunkTable OBJECT-TYPE SYNTAX SEQUENCE OF SnMSTrunkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table contains the configuration of port members of multi-slot trunk groups." ::= { snTrunkInfo 2 } snMSTrunkEntry OBJECT-TYPE SYNTAX SnMSTrunkEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the snMSTrunkTable." INDEX {snMSTrunkPortIndex} ::= { snMSTrunkTable 1 } SnMSTrunkEntry ::= SEQUENCE { snMSTrunkPortIndex INTEGER, snMSTrunkPortList OCTET STRING, snMSTrunkType INTEGER, snMSTrunkRowStatus INTEGER } snMSTrunkPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The primary port of a trunk group. For module with Gig ports, primary port is port 1, 3, 5, 7. For module with 10/100 ports, primary port is port 1, 5, 9, 13, 17, 21." ::= { snMSTrunkEntry 1 } snMSTrunkPortList OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A list of port indices which are the port membership of a trunk group. Each port index is a 16-bit integer in big endian order. The first port index must be the primary port index." ::= { snMSTrunkEntry 2 } snMSTrunkType OBJECT-TYPE SYNTAX INTEGER { switch(1), server(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The trunk connection type which specifies what device the trunk ports are connected to." ::= { snMSTrunkEntry 3 } snMSTrunkRowStatus OBJECT-TYPE SYNTAX INTEGER { invalid(1), valid(2), delete(3), create(4), modify(5) } ACCESS read-write STATUS mandatory DESCRIPTION "To create or delete a table entry." ::= { snMSTrunkEntry 4 } -- Switch Configuration Summary Group snSwSummaryMode OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The Switch Group Configuration Summary is configured either enabled or disabled and the default is disabled mode. enabled(1)...........activate Switch Configuration Summary. disabled(0)..........no Switch Configuration Summary." ::= { snSwSummary 1 } --- Encoded Octet Strings for the VLAN Configuration Table (Obsolete in Chassis Product) snVLanByPortEosTable OBJECT-TYPE SYNTAX SEQUENCE OF SnVLanByPortEosEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of encoded octet strings of entries in snVLanByPortTable. The number of entries is determined by packing of rows from snVLanByPortTable. If snSwSummaryMode is disabled(0), the GET-RESPONSE of this object is NO-SUCH." ::= { snSwSummary 2 } snVLanByPortEosEntry OBJECT-TYPE SYNTAX SnVLanByPortEosEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An EOS row in the table of encoded octet strings for table snVLanByPortTable. Instance returned in Response PDU, On GETs, instance specified is the instance returned. On GET-NEXTs, instance returned is the instance of the last record contained in the octet string. Entries in the table can not be created or deleted via SNMP." INDEX { snVLanByPortVLanEosIndex } ::= { snVLanByPortEosTable 1 } SnVLanByPortEosEntry ::= SEQUENCE { snVLanByPortCfgEos OCTET STRING } snVLanByPortCfgEos OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1400)) ACCESS read-only STATUS mandatory DESCRIPTION "An encoded octet string. On reads it contains an integral number of rows from table snVLanByPortTable. The size of each encoded octet string is less than or equal to 1400 bytes." ::= { snVLanByPortEosEntry 1 } snVLanByPortVLanEosIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Each VLAN EOS Buffer Identifier have a multiple VLAN table entries." ::= { snVLanByPortEosEntry 2 } --- Encoded Octet Strings for the Switch Port Information Table (Obsolete in Chassis Product) snSwPortEosTable OBJECT-TYPE SYNTAX SEQUENCE OF SnSwPortEosEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of encoded octet strings of entries in snSwPortInfoTable. The number of entries is determined by packing of rows from snSwPortInfoTable. If snSwSummaryMode is disabled(0), the GET-RESPONSE of this object is NO-SUCH." ::= { snSwSummary 3 } snSwPortEosEntry OBJECT-TYPE SYNTAX SnSwPortEosEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An EOS row in the table of encoded octet strings for table snSwPortInfoTable. Instance returned in Response PDU, On GETs, instance specified is the instance returned. On GET-NEXTs, instance returned is the instance of the last record contained in the octet string. Entries in the table can not be created or deleted via SNMP." INDEX { snSwPortEosPortNum } ::= { snSwPortEosTable 1 } SnSwPortEosEntry ::= SEQUENCE { snSwPortCfgEos OCTET STRING } snSwPortCfgEos OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1400)) ACCESS read-only STATUS mandatory DESCRIPTION "An encoded octet string. On reads it contains an integral number of rows from table snSwPortInfoTable. The size of each encoded octet string is less than or equal to 1400 bytes." ::= { snSwPortEosEntry 1 } snSwPortEosPortNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port EOS buffer index." ::= { snSwPortEosEntry 2 } --- Encoded Octet Strings for the Forward Database Static Table (Obsolete in Chassis Product) snFdbEosTable OBJECT-TYPE SYNTAX SEQUENCE OF SnFdbEosEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of encoded octet strings of entries in snFdbTable. The number of entries is determined by packing of rows from snFdbTable. If snSwSummaryMode is disabled(0), the GET-RESPONSE of this object is NO-SUCH." ::= { snSwSummary 4 } snFdbEosEntry OBJECT-TYPE SYNTAX SnFdbEosEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An EOS row in the table of encoded octet strings for table snFdbTable. Instance returned in Response PDU, On GETs, instance specified is the instance returned. On GET-NEXTs, instance returned is the instance of the last record contained in the octet string. Entries in the table can not be created or deleted via SNMP." INDEX { snFdbStationEosIndex } ::= { snFdbEosTable 1 } SnFdbEosEntry ::= SEQUENCE { snFdbCfgEos OCTET STRING } snFdbCfgEos OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1400)) ACCESS read-only STATUS mandatory DESCRIPTION "An encoded octet string. On reads it contains an integral number of rows from table snFdbTable. The size of each encoded octet string is less than or equal to 1400 bytes." ::= { snFdbEosEntry 1 } snFdbStationEosIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The FDB Station Eos index to the Fdb Station Eos Buffer." ::= { snFdbEosEntry 2 } --- Encoded Octet Strings for the Port STP Configuration Table (Obsolete in Chassis Product) snPortStpEosTable OBJECT-TYPE SYNTAX SEQUENCE OF SnPortStpEosEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of encoded octet strings of entries in snPortStpTable. The number of entries is determined by packing of rows from snPortStpTable. If snSwSummaryMode is disabled(0), the GET-RESPONSE of this object is NO-SUCH." ::= { snSwSummary 5 } snPortStpEosEntry OBJECT-TYPE SYNTAX SnPortStpEosEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An EOS row in the table of encoded octet strings for table snPortStpTable. Instance returned in Response PDU, On GETs, instance specified is the instance returned. On GET-NEXTs, instance returned is the instance of the last record contained in the octet string. Entries in the table can not be created or deleted via SNMP." INDEX { snPortStpVLanId, snPortStpPortNum } ::= { snPortStpEosTable 1 } SnPortStpEosEntry ::= SEQUENCE { snPortStpCfgEos OCTET STRING } snPortStpCfgEos OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1400)) ACCESS read-only STATUS mandatory DESCRIPTION "An encoded octet string. On reads it contains an integral number of rows from table snPortStpTable. The size of each encoded octet string is less than or equal to 1400 bytes." ::= { snPortStpEosEntry 1 } --- DHCP Gateway List Table snDhcpGatewayListTable OBJECT-TYPE SYNTAX SEQUENCE OF SnDhcpGatewayListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of DHCP gateway list of addresses." ::= { snDhcpGatewayListInfo 1 } snDhcpGatewayListEntry OBJECT-TYPE SYNTAX SnDhcpGatewayListEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the IP Port Address table." INDEX { snDhcpGatewayListId } ::= { snDhcpGatewayListTable 1 } SnDhcpGatewayListEntry ::= SEQUENCE { snDhcpGatewayListId INTEGER, snDhcpGatewayListAddrList OCTET STRING, snDhcpGatewayListRowStatus INTEGER } snDhcpGatewayListId OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "The ID for a DHCP gateway list entry." ::= { snDhcpGatewayListEntry 1 } snDhcpGatewayListAddrList OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4..32)) ACCESS read-write STATUS mandatory DESCRIPTION "The DHCP gateway address list for each DHCP gateway list ID. This list contains 1 to 8 IP addresses represented by octet string." ::= { snDhcpGatewayListEntry 2 } snDhcpGatewayListRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row or modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row other(1)....some other case valid(2)....the row exists and is valid" ::= { snDhcpGatewayListEntry 3 } -- DNS MIB Group snDnsDomainName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) ACCESS read-write STATUS mandatory DESCRIPTION "DNS Domain Name string." ::= { snDnsInfo 1 } snDnsGatewayIpAddrList OBJECT-TYPE SYNTAX OCTET STRING (SIZE(16)) ACCESS read-write STATUS mandatory DESCRIPTION "The DNS Gateway IP address list. This list contains 4 IP addresses represented by octet string." ::= { snDnsInfo 2 } -- MAC filter table snMacFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF SnMacFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "MAC filter table." ::= { snMacFilter 1 } snMacFilterEntry OBJECT-TYPE SYNTAX SnMacFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the MAC filter table." INDEX { snMacFilterIndex } ::= { snMacFilterTable 1 } SnMacFilterEntry ::= SEQUENCE { snMacFilterIndex INTEGER, snMacFilterAction INTEGER, snMacFilterSourceMac MacAddress, snMacFilterSourceMask MacAddress, snMacFilterDestMac MacAddress, snMacFilterDestMask MacAddress, snMacFilterOperator INTEGER, snMacFilterFrameType INTEGER, snMacFilterFrameTypeNum INTEGER, snMacFilterRowStatus INTEGER } snMacFilterIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The table index for a filter entry." ::= { snMacFilterEntry 1 } snMacFilterAction OBJECT-TYPE SYNTAX INTEGER { deny(0), permit(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Action to take if the Mac packet match with this filter." ::= { snMacFilterEntry 2 } snMacFilterSourceMac OBJECT-TYPE SYNTAX MacAddress ACCESS read-write STATUS mandatory DESCRIPTION "Source MAC address." ::= { snMacFilterEntry 3 } snMacFilterSourceMask OBJECT-TYPE SYNTAX MacAddress ACCESS read-write STATUS mandatory DESCRIPTION "Source MAC subnet mask." ::= { snMacFilterEntry 4 } snMacFilterDestMac OBJECT-TYPE SYNTAX MacAddress ACCESS read-write STATUS mandatory DESCRIPTION "Destination MAC address." ::= { snMacFilterEntry 5 } snMacFilterDestMask OBJECT-TYPE SYNTAX MacAddress ACCESS read-write STATUS mandatory DESCRIPTION "Destination MAC subnet mask." ::= { snMacFilterEntry 6 } snMacFilterOperator OBJECT-TYPE SYNTAX INTEGER { equal(0), notEqual(1), less(2), greater(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of comparison to perform." ::= { snMacFilterEntry 7 } snMacFilterFrameType OBJECT-TYPE SYNTAX INTEGER{ notUsed(0), ethernet(1), llc(2), snap(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Frame Type: ethernet-type, LLC and SNAP types" ::= { snMacFilterEntry 8 } snMacFilterFrameTypeNum OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Frame Type Number. 0 means NA" ::= { snMacFilterEntry 9 } snMacFilterRowStatus OBJECT-TYPE SYNTAX INTEGER { invalid(1), valid(2), delete(3), create(4), modify(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row modify(5)...modifies an exsisting row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row invalid(1)...Setting it to 'invalid' has the effect of rendering it inoperative.. valid(2)....the row exists and is valid" ::= { snMacFilterEntry 10 } -- MAC Filter Port access table snMacFilterPortAccessTable OBJECT-TYPE SYNTAX SEQUENCE OF SnMacFilterPortAccessEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "MAC Filter port access table." ::= { snMacFilter 2 } snMacFilterPortAccessEntry OBJECT-TYPE SYNTAX SnMacFilterPortAccessEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the MAC Filter Port access table." INDEX { snMacFilterPortAccessPortIndex } ::= { snMacFilterPortAccessTable 1 } SnMacFilterPortAccessEntry ::= SEQUENCE { snMacFilterPortAccessPortIndex INTEGER, snMacFilterPortAccessFilters OCTET STRING, snMacFilterPortAccessRowStatus INTEGER } snMacFilterPortAccessPortIndex OBJECT-TYPE SYNTAX INTEGER (1..3900) ACCESS read-only STATUS mandatory DESCRIPTION "The port index. For FastIron/NetIron products, port index value is from 1 to 42 For BigIron products, port index is an encoded number: The bit 0 to bit 7: port number. The bit 8 to bit 11: slot number. For virtual router interface, slot number is 15, port number is the virtual router port from 1 to 60. Therefore, port index value for BigIron is from 257 to 3900." ::= { snMacFilterPortAccessEntry 1 } snMacFilterPortAccessFilters OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "1st octet correspond to 1st filter number and so on." ::= { snMacFilterPortAccessEntry 2 } snMacFilterPortAccessRowStatus OBJECT-TYPE SYNTAX INTEGER { invalid(1), valid(2), delete(3), create(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete row in the table and control if they are used. The values that can be written are: delete(3)...deletes the row create(4)...creates a new row If the row exists, then a SET with value of create(4) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: noSuch(0)...no such row invalid(1)...Setting it to 'invalid' has the effect of rendering it inoperative.. valid(2)....the row exists and is valid" ::= { snMacFilterPortAccessEntry 3 } -- NTP general group snNTPGeneral OBJECT IDENTIFIER ::= { snNTP 1 } snNTPPollInterval OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Interval specifies how often to poll the NTP server. Each unit is one second." DEFVAL { 1800 } ::= { snNTPGeneral 1 } snNTPTimeZone OBJECT-TYPE SYNTAX INTEGER { alaska(0), aleutian(1), arizona(2), central(3), eastIndiana(4), eastern(5), hawaii(6), michigan(7), mountain(8), pacific(9), samoa(10), gmtPlus12(11), gmtPlus11(12), gmtPlus10(13), gmtPlus9(14), gmtPlus8(15), gmtPlus7(16), gmtPlus6(17), gmtPlus5(18), gmtPlus4(19), gmtPlus3(20), gmtPlus2(21), gmtPlus1(22), gmt(23), gmtMinus1(24), gmtMinus2(25), gmtMinus3(26), gmtMinus4(27), gmtMinus5(28), gmtMinus6(29), gmtMinus7(30), gmtMinus8(31), gmtMinus9(32), gmtMinus10(33), gmtMinus11(34), gmtMinus12(35) } ACCESS read-write STATUS mandatory DESCRIPTION "Time zone." DEFVAL { gmt } ::= { snNTPGeneral 2 } snNTPSummerTimeEnable OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled (1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable daylight saving time. This enables daylight saving time for time/date starting 02:00:00 of first Sunday in April and ending 02:00:00 of last Sunday in October every year." DEFVAL { disabled } ::= { snNTPGeneral 3 } snNTPSystemClock OBJECT-TYPE SYNTAX OCTET STRING (SIZE (7)) ACCESS read-write STATUS mandatory DESCRIPTION "System clock, in the following format: octet 0: seconds after the minute [0-60] octet 1: minutes after the hour [0-59] octet 2: hours since midnight [0-23] octet 3: day of the month [1-31] octet 4: months since January [0-11] octet 5: years since 1900 octet 6: days since Sunday [0-6] Setting this object requires valid value in octets 0 to 5, and zero in octet 6. System clock can be disabled by setting zero to all octets." ::= { snNTPGeneral 4 } snNTPSync OBJECT-TYPE SYNTAX INTEGER { other(1), synchronize(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Initiate time synchronization to the NTP servers. For set operation, only 'synchronize(2)' is accepted. For get operation, always return 'other(1)'." ::= { snNTPGeneral 5 } -- NTP server table snNTPServerTable OBJECT-TYPE SYNTAX SEQUENCE OF SnNTPServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "NTP (Network Time Protocol) server table." ::= { snNTP 2 } snNTPServerEntry OBJECT-TYPE SYNTAX SnNTPServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the NTP server table." INDEX { snNTPServerIp } ::= { snNTPServerTable 1 } SnNTPServerEntry ::= SEQUENCE { snNTPServerIp IpAddress, snNTPServerVersion INTEGER, snNTPServerRowStatus INTEGER } snNTPServerIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "NTP server IP address." ::= { snNTPServerEntry 1 } snNTPServerVersion OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-write STATUS mandatory DESCRIPTION "NTP server version." DEFVAL { 1 } ::= { snNTPServerEntry 2 } snNTPServerRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4) } ACCESS read-write STATUS mandatory DESCRIPTION "To create or delete a NTP server table entry." ::= { snNTPServerEntry 3 } -- Radius general group snRadiusGeneral OBJECT IDENTIFIER ::= { snRadius 1 } snRadiusSNMPAccess OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicate whether Radius group MIB obejcts can be accessed by SNMP manager. If value is disabled, all Radius group MIB objects return 'general error'." DEFVAL { disabled } ::= { snRadiusGeneral 1 } snRadiusEnableTelnetAuth OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable telnet authentication specified by 'snRadiusLoginMethod'." DEFVAL { disabled } ::= { snRadiusGeneral 2 } snRadiusRetransmit OBJECT-TYPE SYNTAX INTEGER (0..5) ACCESS read-write STATUS mandatory DESCRIPTION "The number of authentication query retransmissions to the Radius server." DEFVAL { 3 } ::= { snRadiusGeneral 3 } snRadiusTimeOut OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-write STATUS mandatory DESCRIPTION "Interval specifies how long to wait for authentication reply from the Radius server, each unit is one second." DEFVAL { 3 } ::= { snRadiusGeneral 4 } snRadiusDeadTime OBJECT-TYPE SYNTAX INTEGER (1..5) ACCESS read-write STATUS mandatory DESCRIPTION "Interval specifies Radius server dead time, each unit is one minute." DEFVAL { 3 } ::= { snRadiusGeneral 5 } snRadiusKey OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "Authentication key." ::= { snRadiusGeneral 6 } snRadiusLoginMethod OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..7)) ACCESS read-write STATUS mandatory DESCRIPTION "A sequence of authentication methods. Each octet represents a method to authenticate the user login process. Each octet has the following enumeration value: enable(1) - authenticate by command line interface enable password radius(2) - authenticate by requesting radius server local(3) - authenticate by local user account table line(4) - authenticate by telnet password tacplus(5) - authenticate by requesting tacplus server none(6) - do not authenticate tacacs(7) - authenticate by requesting tacacs server Setting a zero length octet string invalidates all previous authentication methods." ::= { snRadiusGeneral 7 } snRadiusEnableMethod OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..7)) ACCESS read-write STATUS mandatory DESCRIPTION "A sequence of authentication methods. Each octet represents a method to authenticate the user entering priviledge mode of the command line interface. Each octet has the following enumeration value: enable(1) - authenticate by command line interface enable password radius(2) - authenticate by requesting radius server local(3) - authenticate by local user account table line(4) - authenticate by telnet password tacplus(5) - authenticate by requesting tacplus server none(6) - do not authenticate tacacs(7) - authenticate by requesting tacacs server Setting a zero length octet string invalidates all previous authentication methods." ::= { snRadiusGeneral 8 } snRadiusWebServerMethod OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..7)) ACCESS read-write STATUS mandatory DESCRIPTION "A sequence of authentication methods. Each octet represents a method to authenticate the user accessing the web-server. Each octet has the following enumeration value: enable(1) - authenticate by command line interface enable password radius(2) - authenticate by requesting radius server local(3) - authenticate by local user account table line(4) - authenticate by telnet password tacplus(5) - authenticate by requesting tacplus server none(6) - do not authenticate tacacs(7) - authenticate by requesting tacacs server Setting a zero length octet string invalidates all previous authentication methods." ::= { snRadiusGeneral 9 } snRadiusSNMPServerMethod OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..7)) ACCESS read-write STATUS mandatory DESCRIPTION "A sequence of authentication methods. Each octet represents a method to authenticate the user accessing the snmp-server. Each octet has the following enumeration value: enable(1) - authenticate by command line interface enable password radius(2) - authenticate by requesting radius server local(3) - authenticate by local user account table line(4) - authenticate by telnet password tacplus(5) - authenticate by requesting tacplus server none(6) - do not authenticate tacacs(7) - authenticate by requesting tacacs server Setting a zero length octet string invalidates all previous authentication methods." ::= { snRadiusGeneral 10 } -- Radius server table snRadiusServerTable OBJECT-TYPE SYNTAX SEQUENCE OF SnRadiusServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Radius server table." ::= { snRadius 2 } snRadiusServerEntry OBJECT-TYPE SYNTAX SnRadiusServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Radius server table." INDEX { snRadiusServerIp } ::= { snRadiusServerTable 1 } SnRadiusServerEntry ::= SEQUENCE { snRadiusServerIp IpAddress, snRadiusServerAuthPort INTEGER, snRadiusServerAcctPort INTEGER, snRadiusServerRowStatus INTEGER } snRadiusServerIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Radius server IP address." ::= { snRadiusServerEntry 1 } snRadiusServerAuthPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Authentication UDP port number." DEFVAL { 1645 } ::= { snRadiusServerEntry 2 } snRadiusServerAcctPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Account UDP port number." DEFVAL { 1646 } ::= { snRadiusServerEntry 3 } snRadiusServerRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4) } ACCESS read-write STATUS mandatory DESCRIPTION "To create or delete a Radius server table entry." ::= { snRadiusServerEntry 4 } --- Tacacs General MIBs snTacacsGeneral OBJECT IDENTIFIER ::= { snTacacs 1 } snTacacsRetransmit OBJECT-TYPE SYNTAX INTEGER (0..5) ACCESS read-write STATUS mandatory DESCRIPTION "The number of authentication query retransmissions to the Tacacs server." DEFVAL { 3 } ::= { snTacacsGeneral 1 } snTacacsTimeOut OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-write STATUS mandatory DESCRIPTION "Interval specifies how long to wait for authentication reply from the Tacacs server, each unit is one second." DEFVAL { 3 } ::= { snTacacsGeneral 2 } snTacacsDeadTime OBJECT-TYPE SYNTAX INTEGER (1..5) ACCESS read-write STATUS mandatory DESCRIPTION "Interval specifies Tacacs server dead time, each unit is one minute." DEFVAL { 3 } ::= { snTacacsGeneral 3 } snTacacsKey OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "Authentication key." ::= { snTacacsGeneral 4 } snTacacsSNMPAccess OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicate whether Tacacs group MIB obejcts can be accessed by SNMP manager. If value is disabled, all Tacacs group MIB objects return 'general error'." DEFVAL { disabled } ::= { snTacacsGeneral 5 } -- Tacacs server table snTacacsServerTable OBJECT-TYPE SYNTAX SEQUENCE OF SnTacacsServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Tacacs server table." ::= { snTacacs 2 } snTacacsServerEntry OBJECT-TYPE SYNTAX SnTacacsServerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Tacacs server table." INDEX { snTacacsServerIp } ::= { snTacacsServerTable 1 } SnTacacsServerEntry ::= SEQUENCE { snTacacsServerIp IpAddress, snTacacsServerAuthPort INTEGER, snTacacsServerRowStatus INTEGER } snTacacsServerIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Tacacs server IP address." ::= { snTacacsServerEntry 1 } snTacacsServerAuthPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Authentication UDP port number." DEFVAL { 49 } ::= { snTacacsServerEntry 2 } snTacacsServerRowStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), delete(3), create(4) } ACCESS read-write STATUS mandatory DESCRIPTION "To create or delete a Tacacs server table entry." ::= { snTacacsServerEntry 3 } -- QOS Profile Group snQosProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF SnQosProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table contains the configuration of qos profile groups." ::= { snQos 1 } snQosProfileEntry OBJECT-TYPE SYNTAX SnQosProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the snQosProfileTable." INDEX {snQosProfileIndex} ::= { snQosProfileTable 1 } SnQosProfileEntry ::= SEQUENCE { snQosProfileIndex INTEGER, snQosProfileName DisplayString, snQosProfileRequestedBandwidth INTEGER, snQosProfileCalculatedBandwidth INTEGER } snQosProfileIndex OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "The table index of QOS Profile." ::= { snQosProfileEntry 1 } snQosProfileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Qos Profile Name string." ::= { snQosProfileEntry 2 } snQosProfileRequestedBandwidth OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "Qos Profile Requested Bandwidth." ::= { snQosProfileEntry 3 } snQosProfileCalculatedBandwidth OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Qos Profile Calculated Bandwidth." ::= { snQosProfileEntry 4 } -- QOS Bind Group snQosBindTable OBJECT-TYPE SYNTAX SEQUENCE OF SnQosBindEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table contains the configuration of 802.1p to qos profile binding groups." ::= { snQos 2 } snQosBindEntry OBJECT-TYPE SYNTAX SnQosBindEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of the snQosBindTable." INDEX {snQosBindIndex} ::= { snQosBindTable 1 } SnQosBindEntry ::= SEQUENCE { snQosBindIndex INTEGER, snQosBindPriority INTEGER, snQosBindProfileIndex INTEGER } snQosBindIndex OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "The table index of QOS Bind." ::= { snQosBindEntry 1 } snQosBindPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "QOS bind priority." ::= { snQosBindEntry 2 } snQosBindProfileIndex OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-write STATUS mandatory DESCRIPTION "QOS Bind Profile Index. This is pointer to the index of snQosProfile Table." ::= { snQosBindEntry 3 } END