GE-SINGLEUPS DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, OBJECT-IDENTITY, Counter32, Gauge32, Integer32,enterprises, IpAddress FROM SNMPv2-SMI DisplayString, TimeStamp, TimeInterval, TestAndIncr, AutonomousType, TEXTUAL-CONVENTION FROM SNMPv2-TC; PositiveInteger32 ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "This data type is a non-zero and non-negative value." SYNTAX Integer32 (1..2147483647) NonNegativeInteger32 ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "This data type is a non-negative value." SYNTAX Integer32 (0..2147483647) imv OBJECT IDENTIFIER ::= { enterprises 818 } geHardware OBJECT IDENTIFIER ::= { imv 1 } geSoftware OBJECT IDENTIFIER ::= { imv 2 } geAgent OBJECT IDENTIFIER ::= { imv 3 } geUPS OBJECT IDENTIFIER ::= { geHardware 1 } -- The following list is not really a table, but can be implemented as one in the software. -- The complete UPS section is simply too large to fit in a pre-defined table. -- The solution: -- * All objects are defined for geGenericUPS -- * All individual UPSs of parallel systems can be reached by their respective sequence -- number as reflected in below list in stead of the geGenericUPS objects. geGenericUPS OBJECT IDENTIFIER ::= { geUPS 10 } -- Generic UPS -- upsIdent-gen OBJECT IDENTIFIER ::= { geGenericUPS 1 } upsBattery-gen OBJECT IDENTIFIER ::= { geGenericUPS 2 } upsInput-gen OBJECT IDENTIFIER ::= { geGenericUPS 3 } upsOutput-gen OBJECT IDENTIFIER ::= { geGenericUPS 4 } upsBypass-gen OBJECT IDENTIFIER ::= { geGenericUPS 5 } upsAlarm-gen OBJECT IDENTIFIER ::= { geGenericUPS 6 } upsWellKnownAlarms-gen OBJECT IDENTIFIER ::= { upsAlarm-gen 3 } upsTest-gen OBJECT IDENTIFIER ::= { geGenericUPS 7 } upsWellKnownTests-gen OBJECT IDENTIFIER ::= { upsTest-gen 7 } upsControl-gen OBJECT IDENTIFIER ::= { geGenericUPS 8 } upsConfig-gen OBJECT IDENTIFIER ::= { geGenericUPS 9 } upsGetSet-gen OBJECT IDENTIFIER ::= { geGenericUPS 10 } geUPSTraps-gen OBJECT IDENTIFIER ::= { geGenericUPS 11 } ---- -- Environtmental card -- ---- geEnvironmental OBJECT IDENTIFIER ::= { geHardware 2 } ioInterface-First OBJECT IDENTIFIER ::= { geEnvironmental 1 } ioInterface-Second OBJECT IDENTIFIER ::= { geEnvironmental 2 } ioInterface-Third OBJECT IDENTIFIER ::= { geEnvironmental 3 } ioInterface-Fourth OBJECT IDENTIFIER ::= { geEnvironmental 4 } ioInterface-Fifth OBJECT IDENTIFIER ::= { geEnvironmental 5 } ioInterface-Sixth OBJECT IDENTIFIER ::= { geEnvironmental 6 } ioInterface-Seventh OBJECT IDENTIFIER ::= { geEnvironmental 7 } ioInterface-Eighth OBJECT IDENTIFIER ::= { geEnvironmental 8 } -- First Environmental card -- ioInterfaceInputLine-First OBJECT IDENTIFIER ::= { ioInterface-First 1 } ioInterfaceOutputLine-First OBJECT IDENTIFIER ::= { ioInterface-First 2 } ioInterfaceAnalogueLine-First OBJECT IDENTIFIER ::= { ioInterface-First 3 } ioInterfaceTraps-First OBJECT IDENTIFIER ::= { ioInterface-First 4 } -- Second Environmental card -- ioInterfaceInputLine-Second OBJECT IDENTIFIER ::= { ioInterface-Second 1 } ioInterfaceOutputLine-Second OBJECT IDENTIFIER ::= { ioInterface-Second 2 } ioInterfaceAnalogueLine-Second OBJECT IDENTIFIER ::= { ioInterface-Second 3 } ioInterfaceTraps-Second OBJECT IDENTIFIER ::= { ioInterface-Second 4 } -- Third Environmental card -- ioInterfaceInputLine-Third OBJECT IDENTIFIER ::= { ioInterface-Third 1 } ioInterfaceOutputLine-Third OBJECT IDENTIFIER ::= { ioInterface-Third 2 } ioInterfaceAnalogueLine-Third OBJECT IDENTIFIER ::= { ioInterface-Third 3 } ioInterfaceTraps-Third OBJECT IDENTIFIER ::= { ioInterface-Third 4 } -- Fourth Environmental card -- ioInterfaceInputLine-Fourth OBJECT IDENTIFIER ::= { ioInterface-Fourth 1 } ioInterfaceOutputLine-Fourth OBJECT IDENTIFIER ::= { ioInterface-Fourth 2 } ioInterfaceAnalogueLine-Fourth OBJECT IDENTIFIER ::= { ioInterface-Fourth 3 } ioInterfaceTraps-Fourth OBJECT IDENTIFIER ::= { ioInterface-Fourth 4 } -- Fifth Environmental card -- ioInterfaceInputLine-Fifth OBJECT IDENTIFIER ::= { ioInterface-Fifth 1 } ioInterfaceOutputLine-Fifth OBJECT IDENTIFIER ::= { ioInterface-Fifth 2 } ioInterfaceAnalogueLine-Fifth OBJECT IDENTIFIER ::= { ioInterface-Fifth 3 } ioInterfaceTraps-Fifth OBJECT IDENTIFIER ::= { ioInterface-Fifth 4 } -- Sixth Environmental card -- ioInterfaceInputLine-Sixth OBJECT IDENTIFIER ::= { ioInterface-Sixth 1 } ioInterfaceOutputLine-Sixth OBJECT IDENTIFIER ::= { ioInterface-Sixth 2 } ioInterfaceAnalogueLine-Sixth OBJECT IDENTIFIER ::= { ioInterface-Sixth 3 } ioInterfaceTraps-Sixth OBJECT IDENTIFIER ::= { ioInterface-Sixth 4 } -- Seventh Environmental card -- ioInterfaceInputLine-Seventh OBJECT IDENTIFIER ::= { ioInterface-Seventh 1 } ioInterfaceOutputLine-Seventh OBJECT IDENTIFIER ::= { ioInterface-Seventh 2 } ioInterfaceAnalogueLine-Seventh OBJECT IDENTIFIER ::= { ioInterface-Seventh 3 } ioInterfaceTraps-Seventh OBJECT IDENTIFIER ::= { ioInterface-Seventh 4 } -- Eighth Environmental card -- ioInterfaceInputLine-Eighth OBJECT IDENTIFIER ::= { ioInterface-Eighth 1 } ioInterfaceOutputLine-Eighth OBJECT IDENTIFIER ::= { ioInterface-Eighth 2 } ioInterfaceAnalogueLine-Eighth OBJECT IDENTIFIER ::= { ioInterface-Eighth 3 } ioInterfaceTraps-Eighth OBJECT IDENTIFIER ::= { ioInterface-Eighth 4 } -- -- Modem -- -- geModem OBJECT IDENTIFIER ::= { geHardware 3 } -- -- Device -- -- geDevices OBJECT IDENTIFIER ::= { geHardware 100 } geDevicesDescriptions OBJECT IDENTIFIER ::= { geDevices 1 } advSNMPWebIntCard OBJECT IDENTIFIER ::= { geDevicesDescriptions 1 } snmpWebIntCard OBJECT IDENTIFIER ::= { geDevicesDescriptions 2 } snmpWebIntBox OBJECT IDENTIFIER ::= { geDevicesDescriptions 3 } snmpSWPFAgent OBJECT IDENTIFIER ::= { geDevicesDescriptions 4 } snmpSWJUMPAgent OBJECT IDENTIFIER ::= { geDevicesDescriptions 5 } -- -- Client -- -- geClient OBJECT IDENTIFIER ::= { geSoftware 1 } -- -- Agent -- -- geAgentConfig OBJECT IDENTIFIER ::= { geAgent 1 } geAgentTraps OBJECT IDENTIFIER ::= { geAgent 2 } -- -- The GE UPS group -- geDiscoveredUPSsMask OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Reading this variable returns bit mask indicating which UPSs in a parallel system are alive. Management software should poll only these UPSs on their snmp branches 11-18 as follows: 1 FirstUPS alive 2 SecondUPS alive 4 ThirdUPS alive 8 FourthUPS alive 16 FifthUPS alive 32 SixthUPS alive 64 SeventhUPS alive 128 EigthUPS alive Since the management software should always monitor the GenericUPS branch (10), this value has no meaning for single upses (which provide values on that snmp branch), and should be set to zero in that case." ::= { geUPS 1 } geRequestPacket OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "Put the string, formatted as a IMV/CP4 packet, directly to internally RS485 bus. This OID could be used for accede directly to the internally RS485 bus from a remote place." ::= { geUPS 2 } geReplyPacket OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Contain the reply of the IMV/CP4 request packet sent using the OID geRequestPacket. Every time that a write command has be made at the OID ge RequestPacket, the value of this OID is erased." ::= { geUPS 3 } -- -- The Device Identification group. Generic -- All objects in this group except for upsIdentName and -- upsIdentAttachedDevices are set at device initialization -- and remain static. -- upsIdentManufacturer-gen OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the UPS manufacturer.(*)" ::= { upsIdent-gen 1 } upsIdentModel-gen OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The UPS Model designation.(*)" ::= { upsIdent-gen 2 } upsIdentUPSSoftwareVersion-gen OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The UPS firmware/software version(s). This variable may or may not have the same value as upsIdentAgentSoftwareVersion in some implementations.(*)" ::= { upsIdent-gen 3 } upsIdentAgentSoftwareVersion-gen OBJECT-TYPE SYNTAX DisplayString (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "The UPS agent software version. This variable may or may not have the same value as upsIdentUPSSoftwareVersion in some implementations.(*)" ::= { upsIdent-gen 4 } upsIdentName-gen OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "A string identifying the UPS. This object should be set by the administrator.(*)" ::= { upsIdent-gen 5 } upsIdentAttachedDevices-gen OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator.(*)" ::= { upsIdent-gen 6 } upsIdentUPSSerialNumber-gen OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-only STATUS current DESCRIPTION "The UPS serial number" ::= { upsIdent-gen 7 } upsIdentComProtVersion-gen OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "The IMV communication protocol version" ::= { upsIdent-gen 8 } upsIdentOperatingTime-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The present value of the operating time. total 'on' time since UPS manufactured" ::= { upsIdent-gen 9 } -- -- Battery Group Generic -- upsBatteryStatus-gen OBJECT-TYPE SYNTAX INTEGER { unknown(1), batteryNormal(2), batteryLow(3), batteryDepleted(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).(*)" ::= { upsBattery-gen 1 } upsSecondsOnBattery-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.(*)" ::= { upsBattery-gen 2 } upsEstimatedMinutesRemaining-gen OBJECT-TYPE SYNTAX PositiveInteger32 UNITS "minutes" MAX-ACCESS read-only STATUS current DESCRIPTION "An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.(*)" ::= { upsBattery-gen 3 } upsEstimatedChargeRemaining-gen OBJECT-TYPE SYNTAX Integer32 (0..100) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "An estimate of the battery charge remaining expressed as a percent of full charge.(*)" ::= { upsBattery-gen 4 } upsBatteryVoltage-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "0.1 Volt DC" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the present battery voltage.(*)" ::= { upsBattery-gen 5 } upsBatteryCurrent-gen OBJECT-TYPE SYNTAX Integer32 UNITS "0.1 Amp DC" MAX-ACCESS read-only STATUS current DESCRIPTION "The present battery current.(*)" ::= { upsBattery-gen 6 } upsBatteryTemperature-gen OBJECT-TYPE SYNTAX Integer32 UNITS "degrees Centigrade" MAX-ACCESS read-only STATUS current DESCRIPTION "The ambient temperature at or near the UPS Battery casing.(*)" ::= { upsBattery-gen 7 } -- -- Input Group -- upsInputLineBads-gen OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance.(*)" ::= { upsInput-gen 1 } upsInputNumLines-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of input lines utilized in this device. This variable indicates the number of rows in the input table.(*)" ::= { upsInput-gen 2 } upsInputTable-gen OBJECT-TYPE SYNTAX SEQUENCE OF UpsInputEntry-gen MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of input table entries. The number of entries is given by the value of upsInputNumLines.(*)" ::= { upsInput-gen 3 } upsInputEntry-gen OBJECT-TYPE SYNTAX UpsInputEntry-gen MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to a particular input line.(*)" INDEX { upsInputLineIndex-gen } ::= { upsInputTable-gen 1 } UpsInputEntry-gen ::= SEQUENCE { upsInputLineIndex-gen PositiveInteger32, upsInputFrequency-gen NonNegativeInteger32, upsInputVoltage-gen NonNegativeInteger32, upsInputCurrent-gen NonNegativeInteger32, upsInputTruePower-gen NonNegativeInteger32, upsInputVoltageMin-gen NonNegativeInteger32, upsInputVoltageMax-gen NonNegativeInteger32 } upsInputLineIndex-gen OBJECT-TYPE SYNTAX PositiveInteger32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The input line identifier.(*)" ::= { upsInputEntry-gen 1 } upsInputFrequency-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "0.1 Hertz" MAX-ACCESS read-only STATUS current DESCRIPTION "The present input frequency.(*)" ::= { upsInputEntry-gen 2 } upsInputVoltage-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "RMS Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the present input voltage.(*)" ::= { upsInputEntry-gen 3 } upsInputCurrent-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "0.1 RMS Amp" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the present input current.(*)" ::= { upsInputEntry-gen 4 } upsInputTruePower-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "Watts" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the present input true power.(*)" ::= { upsInputEntry-gen 5 } upsInputVoltageMin-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "RMS Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The lowest magnitude of the input voltage since last read out." ::= { upsInputEntry-gen 6 } upsInputVoltageMax-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "RMS Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The highest magnitude of the input voltage since last read out." ::= { upsInputEntry-gen 7 } -- -- The Output group. -- upsOutputSource-gen OBJECT-TYPE SYNTAX INTEGER { other(1), none(2), normal(3), bypass(4), battery(5), booster(6), reducer(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.(*)" ::= { upsOutput-gen 1 } upsOutputFrequency-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "0.1 Hertz" MAX-ACCESS read-only STATUS current DESCRIPTION "The present output frequency.(*)" ::= { upsOutput-gen 2 } upsOutputNumLines-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of output lines utilized in this device. This variable indicates the number of rows in the output table.(*)" ::= { upsOutput-gen 3 } upsOutputTable-gen OBJECT-TYPE SYNTAX SEQUENCE OF UpsOutputEntry-gen MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of output table entries. The number of entries is given by the value of upsOutputNumLines.(*)" ::= { upsOutput-gen 4 } upsOutputEntry-gen OBJECT-TYPE SYNTAX UpsOutputEntry-gen MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to a particular output line.(*)" INDEX { upsOutputLineIndex-gen } ::= { upsOutputTable-gen 1 } UpsOutputEntry-gen ::= SEQUENCE { upsOutputLineIndex-gen PositiveInteger32, upsOutputVoltage-gen NonNegativeInteger32, upsOutputCurrent-gen NonNegativeInteger32, upsOutputPower-gen NonNegativeInteger32, upsOutputPercentLoad-gen Integer32 } upsOutputLineIndex-gen OBJECT-TYPE SYNTAX PositiveInteger32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The output line identifier.(*)" ::= { upsOutputEntry-gen 1 } upsOutputVoltage-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "RMS Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The present output voltage.(*)" ::= { upsOutputEntry-gen 2 } upsOutputCurrent-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "0.1 RMS Amp" MAX-ACCESS read-only STATUS current DESCRIPTION "The present output current.(*)" ::= { upsOutputEntry-gen 3 } upsOutputPower-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "Watts" MAX-ACCESS read-only STATUS current DESCRIPTION "The present output true power.(*)" ::= { upsOutputEntry-gen 4 } upsOutputPercentLoad-gen OBJECT-TYPE SYNTAX Integer32 (0..200) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.(*)" ::= { upsOutputEntry-gen 5 } -- -- The Bypass group generic. -- upsBypassFrequency-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "0.1 Hertz" MAX-ACCESS read-only STATUS current DESCRIPTION "The present bypass frequency.(*)" ::= { upsBypass-gen 1 } upsBypassNumLines-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.(*)" ::= { upsBypass-gen 2 } upsBypassTable-gen OBJECT-TYPE SYNTAX SEQUENCE OF UpsBypassEntry-gen MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of bypass table entries. The number of entries is given by the value of upsBypassNumLines.(*)" ::= { upsBypass-gen 3 } upsBypassEntry-gen OBJECT-TYPE SYNTAX UpsBypassEntry-gen MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to a particular bypass input.(*)" INDEX { upsBypassLineIndex-gen } ::= { upsBypassTable-gen 1 } UpsBypassEntry-gen ::= SEQUENCE { upsBypassLineIndex-gen PositiveInteger32, upsBypassVoltage-gen NonNegativeInteger32, upsBypassCurrent-gen NonNegativeInteger32, upsBypassPower-gen NonNegativeInteger32 } upsBypassLineIndex-gen OBJECT-TYPE SYNTAX PositiveInteger32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The bypass line identifier.(*)" ::= { upsBypassEntry-gen 1 } upsBypassVoltage-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "RMS Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The present bypass voltage.(*)" ::= { upsBypassEntry-gen 2 } upsBypassCurrent-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "0.1 RMS Amp" MAX-ACCESS read-only STATUS current DESCRIPTION "The present bypass current.(*)" ::= { upsBypassEntry-gen 3 } upsBypassPower-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "Watts" MAX-ACCESS read-only STATUS current DESCRIPTION "The present true power conveyed by the bypass.(*)" ::= { upsBypassEntry-gen 4 } -- -- The Alarm group generic. -- upsAlarmsPresent-gen OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The present number of active alarm conditions.(*)" ::= { upsAlarm-gen 1 } upsAlarmTable-gen OBJECT-TYPE SYNTAX SEQUENCE OF UpsAlarmEntry-gen MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmId equal to 1, and increments the value of upsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of upsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because upsAlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), upsAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of upsAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of upsAlarmsPresent.(*)" ::= { upsAlarm-gen 2 } upsAlarmEntry-gen OBJECT-TYPE SYNTAX UpsAlarmEntry-gen MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to a particular alarm.(*)" INDEX { upsAlarmId-gen } ::= { upsAlarmTable-gen 1 } UpsAlarmEntry-gen ::= SEQUENCE { upsAlarmId-gen PositiveInteger32, upsAlarmDescr-gen AutonomousType, upsAlarmTime-gen TimeStamp } upsAlarmId-gen OBJECT-TYPE SYNTAX PositiveInteger32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique identifier for an alarm condition. This value must remain constant.(*)" ::= { upsAlarmEntry-gen 1 } upsAlarmDescr-gen OBJECT-TYPE SYNTAX AutonomousType MAX-ACCESS read-only STATUS current DESCRIPTION "A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.(*)" ::= { upsAlarmEntry-gen 2 } upsAlarmTime-gen OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0.(*)" ::= { upsAlarmEntry-gen 3 } -- -- Well known alarm conditions generic. -- upsAlarmBatteryBad-gen OBJECT-IDENTITY STATUS current DESCRIPTION "One or more batteries have been determined to require replacement.(*)" ::= { upsWellKnownAlarms-gen 1 } upsAlarmOnBattery-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS is drawing power from the batteries.(*)" ::= { upsWellKnownAlarms-gen 2 } upsAlarmLowBattery-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The remaining battery run-time is less than or equal to upsConfigLowBattTime.(*)" ::= { upsWellKnownAlarms-gen 3 } upsAlarmDepletedBattery-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS will be unable to sustain the present load when and if the utility power is lost.(*)" ::= { upsWellKnownAlarms-gen 4 } upsAlarmTempBad-gen OBJECT-IDENTITY STATUS current DESCRIPTION "A temperature is out of tolerance.(*)" ::= { upsWellKnownAlarms-gen 5 } upsAlarmInputBad-gen OBJECT-IDENTITY STATUS current DESCRIPTION "An input condition is out of tolerance.(*)" ::= { upsWellKnownAlarms-gen 6 } upsAlarmOutputBad-gen OBJECT-IDENTITY STATUS current DESCRIPTION "An output condition (other than OutputOverload) is out of tolerance.(*)" ::= { upsWellKnownAlarms-gen 7 } upsAlarmOutputOverload-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The output load exceeds the UPS output capacity.(*)" ::= { upsWellKnownAlarms-gen 8 } upsAlarmOnBypass-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The Bypass is presently engaged on the UPS.(*)" ::= { upsWellKnownAlarms-gen 9 } upsAlarmBypassBad-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The Bypass is out of tolerance.(*)" ::= { upsWellKnownAlarms-gen 10 } upsAlarmOutputOffAsRequested-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS has shutdown as requested, i.e., the output is off.(*)" ::= { upsWellKnownAlarms-gen 11 } upsAlarmUpsOffAsRequested-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The entire UPS has shutdown as commanded.(*)" ::= { upsWellKnownAlarms-gen 12 } upsAlarmChargerFailed-gen OBJECT-IDENTITY STATUS current DESCRIPTION "An uncorrected problem has been detected within the UPS charger subsystem.(*)" ::= { upsWellKnownAlarms-gen 13 } upsAlarmUpsOutputOff-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The output of the UPS is in the off state.(*)" ::= { upsWellKnownAlarms-gen 14 } upsAlarmUpsSystemOff-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS system is in the off state.(*)" ::= { upsWellKnownAlarms-gen 15 } upsAlarmFanFailure-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The failure of one or more fans in the UPS has been detected.(*)" ::= { upsWellKnownAlarms-gen 16 } upsAlarmFuseFailure-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The failure of one or more fuses has been detected.(*)" ::= { upsWellKnownAlarms-gen 17 } upsAlarmGeneralFault-gen OBJECT-IDENTITY STATUS current DESCRIPTION "A general fault in the UPS has been detected.(*)" ::= { upsWellKnownAlarms-gen 18 } upsAlarmDiagnosticTestFailed-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The result of the last diagnostic test indicates a failure.(*)" ::= { upsWellKnownAlarms-gen 19 } upsAlarmCommunicationsLost-gen OBJECT-IDENTITY STATUS current DESCRIPTION "A problem has been encountered in the communications between the agent and the UPS.(*)" ::= { upsWellKnownAlarms-gen 20 } upsAlarmAwaitingPower-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS output is off and the UPS is awaiting the return of input power.(*)" ::= { upsWellKnownAlarms-gen 21 } upsAlarmShutdownPending-gen OBJECT-IDENTITY STATUS current DESCRIPTION "A upsShutdownAfterDelay countdown is underway.(*)" ::= { upsWellKnownAlarms-gen 22 } upsAlarmShutdownImminent-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown.(*)" ::= { upsWellKnownAlarms-gen 23 } upsAlarmTestInProgress-gen OBJECT-IDENTITY STATUS current DESCRIPTION "A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY.(*)" ::= { upsWellKnownAlarms-gen 24 } upsAlarmReceptacleOff-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The receptacle are switch off " ::= { upsWellKnownAlarms-gen 25 } upsAlarmMaskA-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 MAX-ACCESS read-only STATUS current DESCRIPTION "Specifies which alarm can be handled by the UPS. The 'Mask' parameter is a Long Integer32. The meaning of every bit is the same as for the 'upsAlarmGroupA' command. A bit having value=1 indicates that the corresponding alarm is handled by the UPS." ::= { upsAlarm-gen 4 } -- -- The Test Group generic -- upsTestId-gen OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-write STATUS current DESCRIPTION "The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in upsTestResultsSummary. Tests in progress may be aborted by setting the upsTestId variable to upsTestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value upsTestNoTestsInitiated is returned.(*)" ::= { upsTest-gen 1 } -- see [6] for more information on the semantics of objects with -- syntax of TestAndIncr upsTestSpinLock-gen OBJECT-TYPE SYNTAX TestAndIncr MAX-ACCESS read-write STATUS current DESCRIPTION "A spin lock on the test subsystem. The spinlock is used as follows. Before starting a test, a manager-station should make sure that a test is not in progress as follows: try-again: get (upsTestSpinLock) while (upsTestResultsSummary == inProgress) { /* loop while a test is running for another manager */ short delay get (upsTestSpinLock) } lock-value = upsTestSpinLock /* no test in progress, start the test */ set (upsTestSpinLock = lock-value, upsTestId = requested-test) if (error-index == 1) { /* (upsTestSpinLock failed) */ /* if problem is not access control, then some other manager slipped in ahead of us */ goto try-again } if (error-index == 2) { /* (upsTestId) */ /* cannot perform the test */ give up } /* test started ok */ /* wait for test completion by polling upsTestResultsSummary */ get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) while (upsTestResultsSummary == inProgress) { short delay get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) } /* when test completes, retrieve any additional test results */ /* if upsTestSpinLock == lock-value + 1, then these are our test */ /* results (as opposed to another manager's */ The initial value of upsTestSpinLock at agent initialization shall be 1.(*)" ::= { upsTest-gen 2 } upsTestResultsSummary-gen OBJECT-TYPE SYNTAX INTEGER { donePass(1), doneWarning(2), doneError(3), aborted(4), inProgress(5), noTestsInitiated(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of upsTestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.(*)" ::= { upsTest-gen 3 } upsTestResultsDetail-gen OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Additional information about upsTestResultsSummary. If no additional information available, a zero length string is returned.(*)" ::= { upsTest-gen 4 } upsTestStartTime-gen OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestStartTime has the value 0.(*)" ::= { upsTest-gen 5 } upsTestElapsedTime-gen OBJECT-TYPE SYNTAX TimeInterval MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestElapsedTime has the value 0.(*)" ::= { upsTest-gen 6 } -- -- Well known tests generic. -- upsTestNoTestsInitiated-gen OBJECT-IDENTITY STATUS current DESCRIPTION "No tests have been initiated and no test is in progress.(*)" ::= { upsWellKnownTests-gen 1 } upsTestAbortTestInProgress-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The test in progress is to be aborted / the test in progress was aborted.(*)" ::= { upsWellKnownTests-gen 2 } upsTestGeneralSystemsTest-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The manufacturer's standard test of UPS device systems.(*)" ::= { upsWellKnownTests-gen 3 } upsTestQuickBatteryTest-gen OBJECT-IDENTITY STATUS current DESCRIPTION "A test that is sufficient to determine if the battery needs replacement.(*)" ::= { upsWellKnownTests-gen 4 } upsTestDeepBatteryCalibration-gen OBJECT-IDENTITY STATUS current DESCRIPTION "The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load.(*)" ::= { upsWellKnownTests-gen 5 } -- -- The Control group generic. -- upsShutdownType-gen OBJECT-TYPE SYNTAX INTEGER { output(1), system(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object determines the nature of the action to be taken at the time when the countdown of the upsShutdownAfterDelay and upsRebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.(*)" ::= { upsControl-gen 1 } upsShutdownAfterDelay-gen OBJECT-TYPE SYNTAX Integer32 (-1..2147483648) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if upsShutdownType = system and the system is already off. Similarly, there is no additional action at that time if upsShutdownType = output and the output is already off. When read, upsShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any upsShutdownAfterDelay already in effect.(*)" ::= { upsControl-gen 2 } upsStartupAfterDelay-gen OBJECT-TYPE SYNTAX Integer32 (-1..2147483648) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any upsStartupAfterDelay countdown or upsRebootWithDuration countdown in progress. When read, upsStartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.(*)" ::= { upsControl-gen 3 } upsRebootWithDuration-gen OBJECT-TYPE SYNTAX Integer32 (-1..300) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, upsRebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.(*)" ::= { upsControl-gen 4 } upsAutoRestart-gen OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this object to 'on' will cause the UPS system to restart after a shutdown if the shutdown occurred during a power loss as a result of either a upsShutdownAfterDelay or an internal battery depleted condition. Setting this object to 'off' will prevent the UPS system from restarting after a shutdown until an operator manually or remotely explicitly restarts it. If the UPS is in a startup or reboot countdown, then the UPS will not restart until that delay has been satisfied.(*)" ::= { upsControl-gen 5 } upsReceptaclesNum-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of receptacles utilized in this device. This entry indicates the number of rows in the receptacle table." ::= { upsControl-gen 6 } upsReceptacleTable-gen OBJECT-TYPE SYNTAX SEQUENCE OF UpsReceptacleEntry-gen MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of receptacle table entries. The number of entries is given by the value of upsReceptacleNum." ::= { upsControl-gen 7 } upsReceptacleEntry-gen OBJECT-TYPE SYNTAX UpsReceptacleEntry-gen MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information applicable to a particular receptacle." INDEX { upsReceptacleLineIndex-gen } ::= { upsReceptacleTable-gen 1 } UpsReceptacleEntry-gen ::= SEQUENCE { upsReceptacleLineIndex-gen PositiveInteger32, upsReceptacleOnOff-gen Integer32 } upsReceptacleLineIndex-gen OBJECT-TYPE SYNTAX PositiveInteger32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The receptacle line identifier." ::= { upsReceptacleEntry-gen 1 } upsReceptacleOnOff-gen OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The present state of the receptacle. Setting this object to 'on' will cause the receptacle to be turned on. Setting this object to 'off' will turn the receptacle off. If the receptacle is already in the desired state nothing will happen. After an autorestart (see upsAutoRestart) the receptacle will be on." ::= { upsReceptacleEntry-gen 2 } upsUPSMode-gen OBJECT-TYPE SYNTAX INTEGER { off-line(1), on-line(2), ecomode(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The operation mode off the UPS. Off-line indicates a mode in which the input power is transferred to the output directly or via a step-up or step-down transformer. On-line mode indicates a mode in which the output power is regenerated through some convertor. the operating mode of the UPS may be fixed, or may be selectable (e.g. an on-line UPS with ecomode)" ::= { upsControl-gen 8 } upsRectifierOnOff-gen OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The present state of the rectifier. Setting this object to 'on' will cause the rectifier to be turned on. Setting this object to 'off' will turn the rectifier off. If the rectifier is already in the desired state nothing will happen. " ::= { upsControl-gen 9 } upsBatteryChargeMethod-gen OBJECT-TYPE SYNTAX INTEGER { normal-charge(1), boost-charge(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The present state of the charge method. Setting this object to 'Normal charge' will cause the battery to be charged using the normal method. Setting this object to 'Boost charge' will charge the battery in boost mode. If the charge method is already in the desired state nothing will happen. " ::= { upsControl-gen 10 } upsInverterOnOff-gen OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The present state of the inverter. Setting this object to 'on' will cause the inverter to be turned on. Setting this object to 'off' will turn the inverter off. If the inverter is already in the desired state nothing will happen. " ::= { upsControl-gen 11 } upsBypassOnOff-gen OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The present state of the bypass. Setting this object to 'on' will cause the bypass to be activated. Setting this object to 'off' will deactivate the bypass. If the UPS is already in the desired state nothing will happen. " ::= { upsControl-gen 12 } upsLoadSource-gen OBJECT-TYPE SYNTAX INTEGER { on-bypass(1), on-Inverter(2), on-Detour(3), load-Off(4), other (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "The present source of the load. Setting this object to 'On bypass' will cause the load to be supplied by the bypass. Setting this object to 'On inverter' will cause the load to be supplied by the inverter. If the load is already supplied by the desired source nothing will happen. " ::= { upsControl-gen 13 } -- -- The Configuration group generic. -- upsConfigInputVoltage-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "RMS Volts" MAX-ACCESS read-write STATUS current DESCRIPTION "The magnitude of the nominal input voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*)" ::= { upsConfig-gen 1 } upsConfigInputFreq-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "0.1 Hertz" MAX-ACCESS read-write STATUS current DESCRIPTION "The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*)" ::= { upsConfig-gen 2 } upsConfigOutputVoltage-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "RMS Volts" MAX-ACCESS read-write STATUS current DESCRIPTION "The magnitude of the nominal output voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*)" ::= { upsConfig-gen 3 } upsConfigOutputFreq-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "0.1 Hertz" MAX-ACCESS read-write STATUS current DESCRIPTION "The nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.(*)" ::= { upsConfig-gen 4 } upsConfigOutputVA-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "Volt-Amps" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the nominal Volt-Amp rating.(*)" ::= { upsConfig-gen 5 } upsConfigOutputPower-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "Watts" MAX-ACCESS read-only STATUS current DESCRIPTION "The magnitude of the nominal true power rating.(*)" ::= { upsConfig-gen 6 } upsConfigLowBattTime-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "minutes" MAX-ACCESS read-write STATUS current DESCRIPTION "The value of upsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (discontinuous) values, then the agent shall round up to the next supported value. If the requested value is larger than the largest supported value, then the largest supported value shall be selected.(*)" ::= { upsConfig-gen 7 } upsConfigAudibleStatus-gen OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2), muted(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self-describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm. It will remain muted until it would normally stop sounding and the value returned for read operations during this period shall equal muted(3). At the end of this period, the value shall revert to enabled(2). Writes of the value muted(3) when the audible alarm is not sounding shall be accepted but otherwise shall have no effect.(*)" ::= { upsConfig-gen 8 } upsConfigLowVoltageTransferPoint-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "RMS Volts" MAX-ACCESS read-write STATUS current DESCRIPTION "The minimum input line voltage allowed before the UPS system transfers to battery backup.(*)" ::= { upsConfig-gen 9 } upsConfigHighVoltageTransferPoint-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "RMS Volts" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum line voltage allowed before the UPS system transfers to battery backup.(*)" ::= { upsConfig-gen 10 } upsConfigBatteryCapacity-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "Amps Hours" MAX-ACCESS read-write STATUS current DESCRIPTION "The installed battery capacity. This value is the 'factory'-value, not the value after calibration." ::= { upsConfig-gen 11 } upsConfigBatteryChargeCurrent-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "0.1 Amp DC" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum battery charge current, including external chargers." ::= { upsConfig-gen 12 } upsConfigNoLoadShutdown-gen OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Dis- or enable 'no load' shutdown from the contact interface." ::= { upsConfig-gen 13 } upsConfigStartDelay-gen OBJECT-TYPE SYNTAX PositiveInteger32 UNITS "minutes" MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum required autonomy time before the UPS may perform an autorestart." ::= { upsConfig-gen 14 } -- -- The GetSet group generic. -- upsEventGetNext-gen OBJECT-TYPE SYNTAX PositiveInteger32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventSetStartingTimeStamp will be used as the start value of the table with the lowest index number." ::= { upsGetSet-gen 1 } upsEventGetPrevious-gen OBJECT-TYPE SYNTAX PositiveInteger32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of events to retreive from the UPS event buffer. When this object is set the EventTable will be filled with the requested number of entries. The value upsEventLastTime will be used as the last value of the table with the highest index number. Returns SNMP-NOSUCHNAME for UPSs that don't support this command." ::= { upsGetSet-gen 2 } upsEventSetStartingTimeStamp-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 MAX-ACCESS read-write STATUS current DESCRIPTION "The timestamp which is used as starting point for downloading events from the UPS event buffer" ::= { upsGetSet-gen 3 } upsEventRetreiveCurrentTimeStamp-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current timestamp is retreived from the UPS" ::= { upsGetSet-gen 4 } upsEventTableSize-gen OBJECT-TYPE SYNTAX NonNegativeInteger32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of entries in the event table. This object indicates the number of rows in the event table." ::= { upsGetSet-gen 5 } upsEventTable-gen OBJECT-TYPE SYNTAX SEQUENCE OF UpsEventEntry-gen MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of event table entries. The number of entries is always 10, and the value of upsEventTableSize gives the number of valid entries from the begging of the table. Invalid entries return 0. To prevent problems with simultaneous queries from several agents, these values MUST be accessed using several PDUs in the same SNMP message ( is (1..10)): PDU-SET upsSetStartingTimeStamp