-- -- Copyright 1999 by Fore Systems, Inc. -- Converted to SMIv2 rfc 2578,2579,2580 - STD 58 -- -- Copyright 1999 by Fore Systems, Inc. -- All Rights Reserved -- -- This mib implements management information for -- the PLCP convergence layer in an atm interface. -- Typically PLCP framing is used to encapsulate -- ATM cells for transmission over a DS3/E3 link. Fore-PLCP-MIB DEFINITIONS ::= BEGIN IMPORTS Counter32, OBJECT-TYPE, MODULE-IDENTITY, Integer32, NOTIFICATION-TYPE FROM SNMPv2-SMI asx FROM Fore-Common-MIB ifIndex,ifName FROM IF-MIB trapLogIndex FROM Fore-TrapLog-MIB; forePlcpMib MODULE-IDENTITY LAST-UPDATED "9911050000Z" ORGANIZATION "FORE" CONTACT-INFO " Postal: FORE Systems Inc. 1000 FORE Drive Warrendale, PA 15086-7502 Tel: +1 724 742 6900 Email: nm_mibs@fore.com Web: http://www.fore.com" DESCRIPTION " This mib implements management information for the PLCP convergence layer in an atm interface. Typically PLCP framing is used to encapsulate ATM cells for transmission over a DS3/E3 link." ::= { asx 13 } forePlcpConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF ForePlcpConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PLCP convergence layer information configuration parameters." ::= { forePlcpMib 1 } forePlcpConfigEntry OBJECT-TYPE SYNTAX ForePlcpConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table entry containing PLCP convergence layer configuration information for each atm interface using PLCP." INDEX { ifIndex } ::= { forePlcpConfigTable 1 } ForePlcpConfigEntry ::= SEQUENCE { forePlcpConfigFrameFormat INTEGER } forePlcpConfigFrameFormat OBJECT-TYPE SYNTAX INTEGER { forePlcpFrameFormatDs1(1), forePlcpFrameFormatE1(2), forePlcpFrameFormatDs3(3), forePlcpFrameFormatE3(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable controls the PLCP framing format used to carry ATM cells over this interface. Note that some interfaces may not support all formats and that this variable may be read-only for some interfaces." ::= { forePlcpConfigEntry 1 } forePlcpTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF ForePlcpTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PLCP convergence layer information and parameters." ::= { forePlcpMib 2 } forePlcpTotalEntry OBJECT-TYPE SYNTAX ForePlcpTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table entry containing PLCP convergence layer information for each atm interface using PLCP." INDEX { ifIndex } ::= { forePlcpTotalTable 1 } ForePlcpTotalEntry ::= SEQUENCE { forePlcpTotalFerrCount Counter32, forePlcpTotalLofSeconds Counter32, forePlcpTotalBip8Count Counter32, forePlcpTotalFebeCount Counter32, forePlcpTotalYellowAlarmSeconds Counter32 } forePlcpTotalFerrCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of framing errors detected since the interface was reset. A framing error is determined by errors in the A1 and A2 bytes of the PLCP frame." ::= { forePlcpTotalEntry 1 } forePlcpTotalLofSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds an out of frame condition persisted." ::= { forePlcpTotalEntry 2 } forePlcpTotalBip8Count OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Bit Interleaved Parity errors detected since the interface was reset. A BIP error is determined by using the parity carried in the B1 byte of the PLCP frame." ::= { forePlcpTotalEntry 3 } forePlcpTotalFebeCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End BIP Errors detected. This information is determined by examination of the G1 byte in the PLCP frame." ::= { forePlcpTotalEntry 4 } forePlcpTotalYellowAlarmSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that a far end yellow alarm condition has persisted. This information is determined by examiniation of the G1 byte of the PLCP frame." ::= { forePlcpTotalEntry 5 } -- Current table forePlcpCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF ForePlcpCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PLCP convergence layer information and parameters." ::= { forePlcpMib 3 } forePlcpCurrentEntry OBJECT-TYPE SYNTAX ForePlcpCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table entry containing PLCP convergence layer current statistics for each atm interface using PLCP." INDEX { ifIndex } ::= { forePlcpCurrentTable 1 } ForePlcpCurrentEntry ::= SEQUENCE { forePlcpCurrentFerrCount Counter32, forePlcpCurrentBip8Count Counter32, forePlcpCurrentFebeCount Counter32, forePlcpCurrentErrSeconds Counter32, forePlcpCurrentSevErrSeconds Counter32, forePlcpCurrentUnavailSeconds Counter32 } forePlcpCurrentFerrCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of framing errors detected in current interval. A framing error is determined by errors in the A1 and A2 bytes of the PLCP frame." ::= { forePlcpCurrentEntry 1 } forePlcpCurrentBip8Count OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Bit Interleaved Parity errors detected in the current interval. A BIP error is determined by using the parity carried in the B1 byte of the PLCP frame." ::= { forePlcpCurrentEntry 2 } forePlcpCurrentFebeCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End BIP Errors detected in the current interval. This information is determined by examination of the G1 byte in the PLCP frame." ::= { forePlcpCurrentEntry 3 } forePlcpCurrentErrSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Errored Seconds in current interval" ::= { forePlcpCurrentEntry 4 } forePlcpCurrentSevErrSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Severely Errored Seconds in current interval" ::= { forePlcpCurrentEntry 5 } forePlcpCurrentUnavailSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Unavailable Seconds in the current interval" ::= { forePlcpCurrentEntry 6 } -- Interval table forePlcpIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF ForePlcpIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval table of PLCP convergence layer information and parameters." ::= { forePlcpMib 4 } forePlcpIntervalEntry OBJECT-TYPE SYNTAX ForePlcpIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table entry containing PLCP convergence layer current statistics for each atm interface using PLCP." INDEX { ifIndex, forePlcpInterval } ::= { forePlcpIntervalTable 1 } ForePlcpIntervalEntry ::= SEQUENCE { forePlcpInterval Integer32, forePlcpIntervalFerrCount Counter32, forePlcpIntervalBip8Count Counter32, forePlcpIntervalFebeCount Counter32, forePlcpIntervalErrSeconds Counter32, forePlcpIntervalSevErrSeconds Counter32, forePlcpIntervalUnavailSeconds Counter32 } forePlcpInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Interval number" ::= { forePlcpIntervalEntry 1 } forePlcpIntervalFerrCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of framing errors detected in particular interval. A framing error is determined by errors in the A1 and A2 bytes of the PLCP frame." ::= { forePlcpIntervalEntry 2 } forePlcpIntervalBip8Count OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Bit Interleaved Parity errors detected in the particular interval. A BIP error is determined by using the parity carried in the B1 byte of the PLCP frame." ::= { forePlcpIntervalEntry 3 } forePlcpIntervalFebeCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End BIP Errors detected in the particular interval. This information is determined by examination of the G1 byte in the PLCP frame." ::= { forePlcpIntervalEntry 4 } forePlcpIntervalErrSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Errored Seconds in particular interval" ::= { forePlcpIntervalEntry 5 } forePlcpIntervalSevErrSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Severely Errored Seconds in particular interval" ::= { forePlcpIntervalEntry 6 } forePlcpIntervalUnavailSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Unavailable Seconds in the particular interval" ::= { forePlcpIntervalEntry 7 } -- Diagnostics Section -- forePlcpDiagnosticsTable OBJECT-TYPE -- SYNTAX SEQUENCE OF ForePlcpDiagnosticsEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "A table of PLCP convergence layer information -- and parameters." -- ::= { forePlcpMib 3 } -- -- The Diagnostics table is tentativly defined as below, however it -- is subject to change -- -- --forePlcpDiagnosticsEntry OBJECT-TYPE -- SYNTAX ForePlcpDiagnosticsEntry -- ACCESS not-accessible -- STATUS mandatory -- DESCRIPTION -- "A table entry containing PLCP convergence layer -- information for each atm interface using PLCP." -- INDEX { ifIndex } -- ::= { forePlcpDiagnosticsTable 1 } --ForePlcpDiagnosticsEntry ::= -- SEQUENCE { -- } -- Trap Section forePlcpYellowDetected NOTIFICATION-TYPE OBJECTS { ifIndex, ifName, trapLogIndex } STATUS current DESCRIPTION "This trap indicates that the specified DS3 port has detected incoming PLCP Yellow Alarm." ::= { forePlcpMib 0 1 } forePlcpYellowCleared NOTIFICATION-TYPE OBJECTS { ifIndex, ifName, trapLogIndex } STATUS current DESCRIPTION "This trap indicates that the specified DS3 port has detected clearance of incoming PLCP Yellow Alarm." ::= { forePlcpMib 0 2 } forePlcpLOFDetected NOTIFICATION-TYPE OBJECTS { ifIndex, ifName, trapLogIndex } STATUS current DESCRIPTION "This trap indicates that the specified DS3 port has detected incoming PLCP LOF Alarm." ::= { forePlcpMib 0 3 } forePlcpLOFCleared NOTIFICATION-TYPE OBJECTS { ifIndex, ifName, trapLogIndex } STATUS current DESCRIPTION "This trap indicates that the specified DS3 port has detected clearance of incoming PLCP LOF Alarm." ::= { forePlcpMib 0 4 } END