-- -- Copyright 1997 ADC Telecommunications, Inc. All rights reserved. -- -- ADC Telecommunications, Inc. Confidential and Proprietary -- This work contains valuable confidential and proprietary information. -- Disclosure, use or reproduction without the written authorization of ADC -- Telecommunications, Inc. is prohibited. This unpublished work by ADC -- Telecommunications, Inc. is protected by the laws of the United States and -- other countries. -- FRAMEVISIONFPING-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress, Counter, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- Internal Datatypes -- Valid DLCIs are 0..1023 and OTHER (2^31-1 is "other" VC) FribDLCI ::= INTEGER (0..2147483646) -- From SNMPv2-SMI (SimpleTest can't compile if mix v1 & v2) Counter32 ::= Counter -------------------------------------------------------------------------- -- The ADC Kentrox FrameVision Fping Enterprise MIB Module. -------------------------------------------------------------------------- -- internet(1).private(4).enterprises(1).adcKentrox(181).miblets(100).2 -- -- NOTE: The following line must say "OBJECT IDENTIFIER" to compile -- for HP OpenView and Sun Net Manager. However, it must say "OBJECT-TYPE" -- to compile with Epilogue. -- framevisionfping OBJECT IDENTIFIER ::= { enterprises adcKentrox(181) miblets(100) 2 } -------------------------------------------------------------------------- -- Groups in the ADC Kentrox FrameVision Enterprise MIB Module. -------------------------------------------------------------------------- fpingMib OBJECT IDENTIFIER ::= { framevisionfping 1 } fpingAuto OBJECT IDENTIFIER ::= { framevisionfping 2 } fpingManual OBJECT IDENTIFIER ::= { framevisionfping 3 } -------------------------------------------------------------------- -- BEGIN - framevision fping MIB variables -------------------------------------------------------------------- fpingMibVersion OBJECT-TYPE SYNTAX INTEGER { version1 (1) } ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingMib 1 } fpingMibLastChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingMib 2 } -------------------------------------------------------------------- -- BEGIN - framevision fping auto fping config MIB variables -------------------------------------------------------------------- fpingAutoCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF FpingAutoCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "." ::= { fpingAuto 1 } fpingAutoCfgEntry OBJECT-TYPE SYNTAX FpingAutoCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "." INDEX { fpingAutoCfgIfIndex } ::= { fpingAutoCfgTable 1 } FpingAutoCfgEntry ::= SEQUENCE { fpingAutoCfgIfIndex INTEGER, fpingAutoCfgLastChange TimeTicks, fpingAutoCfgGen INTEGER, fpingAutoCfgThresh INTEGER, fpingAutoCfgReset INTEGER } fpingAutoCfgIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoCfgEntry 1 } fpingAutoCfgLastChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoCfgEntry 2 } fpingAutoCfgGen OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "." ::= { fpingAutoCfgEntry 3 } fpingAutoCfgThresh OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "." ::= { fpingAutoCfgEntry 4 } fpingAutoCfgReset OBJECT-TYPE SYNTAX INTEGER { fpingResetIdle (1), fpingResetStart (2) } ACCESS read-write STATUS mandatory DESCRIPTION "." ::= { fpingAutoCfgEntry 5 } fpingAutoDuration OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAuto 2 } fpingAutoClearData OBJECT-TYPE SYNTAX INTEGER { clearDataIdle (1), clearDataStart (2) } ACCESS read-write STATUS mandatory DESCRIPTION "." ::= { fpingAuto 3 } fpingAutoTable OBJECT-TYPE SYNTAX SEQUENCE OF FpingAutoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "." ::= { fpingAuto 4 } fpingAutoEntry OBJECT-TYPE SYNTAX FpingAutoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "." INDEX { fpingAutoIfIndex, fpingAutoDLCI } ::= { fpingAutoTable 1 } FpingAutoEntry ::= SEQUENCE { fpingAutoIfIndex INTEGER, fpingAutoDLCI FribDLCI, fpingAutoDelayMin INTEGER, fpingAutoDelayMax INTEGER, fpingAutoDelayAvg INTEGER, fpingAutoLost Counter32, fpingAutoTotal Counter32, fpingAutoThreshExceeded Counter32, fpingAutoRmtDLCI FribDLCI, fpingAutoRmtIpaddr IpAddress, fpingAutoTotalPktsLocalTx Counter32, fpingAutoTotalPktsLocalRx Counter32, fpingAutoTotalPktsRmtTx Counter32, fpingAutoTotalPktsRmtRx Counter32, fpingAutoStatus INTEGER, fpingAutoFailedEvents Counter32 } fpingAutoIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoEntry 1 } fpingAutoDLCI OBJECT-TYPE SYNTAX FribDLCI ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoEntry 2 } fpingAutoDelayMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoEntry 3 } fpingAutoDelayMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoEntry 4 } fpingAutoDelayAvg OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoEntry 5 } fpingAutoLost OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoEntry 6 } fpingAutoTotal OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoEntry 7 } fpingAutoThreshExceeded OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoEntry 8 } fpingAutoRmtDLCI OBJECT-TYPE SYNTAX FribDLCI ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoEntry 9 } fpingAutoRmtIpaddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoEntry 10 } fpingAutoTotalPktsLocalTx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoEntry 11 } fpingAutoTotalPktsLocalRx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoEntry 12 } fpingAutoTotalPktsRmtTx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoEntry 13 } fpingAutoTotalPktsRmtRx OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoEntry 14 } fpingAutoStatus OBJECT-TYPE SYNTAX INTEGER { fpingDisabled (1), lastFpingSucceeded (2), lastFpingFailed (3), notMonitoringFping (4), waitingToStartFping (5) } ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoEntry 15 } fpingAutoFailedEvents OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingAutoEntry 16 } -------------------------------------------------------------------- -- BEGIN - framevision fping manual fping MIB variables -------------------------------------------------------------------- fpingManualTable OBJECT-TYPE SYNTAX SEQUENCE OF FpingManualEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "." ::= { fpingManual 1 } fpingManualEntry OBJECT-TYPE SYNTAX FpingManualEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "." INDEX { fpingManualIfIndex, fpingManualDLCI } ::= { fpingManualTable 1 } FpingManualEntry ::= SEQUENCE { fpingManualIfIndex INTEGER, fpingManualDLCI FribDLCI, fpingManualAction INTEGER, fpingManualState INTEGER, fpingManualFreq INTEGER, fpingManualLen INTEGER, fpingManualCur INTEGER, fpingManualMin INTEGER, fpingManualMax INTEGER, fpingManualAvg INTEGER, fpingManualLost INTEGER, fpingManualTotal INTEGER, fpingManualRmtDLCI FribDLCI, fpingManualRmtIpaddr IpAddress } fpingManualIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingManualEntry 1 } fpingManualDLCI OBJECT-TYPE SYNTAX FribDLCI ACCESS read-write STATUS mandatory DESCRIPTION "." ::= { fpingManualEntry 2 } fpingManualAction OBJECT-TYPE SYNTAX INTEGER { fpingManualActionStart (1), fpingManualActionStop (2) } ACCESS read-write STATUS mandatory DESCRIPTION "." ::= { fpingManualEntry 3 } fpingManualState OBJECT-TYPE SYNTAX INTEGER { fpingManualStateIdle (1), fpingManualStateOtherStart (2), fpingManualStarteRunning (3) } ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingManualEntry 4 } fpingManualFreq OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "." ::= { fpingManualEntry 5 } fpingManualLen OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "." ::= { fpingManualEntry 6 } fpingManualCur OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingManualEntry 7 } fpingManualMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingManualEntry 8 } fpingManualMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingManualEntry 9 } fpingManualAvg OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingManualEntry 10 } fpingManualLost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingManualEntry 11 } fpingManualTotal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingManualEntry 12 } fpingManualRmtDLCI OBJECT-TYPE SYNTAX FribDLCI ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingManualEntry 13 } fpingManualRmtIpaddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "." ::= { fpingManualEntry 14 } END