-- -- FILE NAME = ED-5000.MIB ($Revision: 1.9 $) -- CONTENTS = MIB Definition for ED-5000 Fibre Channel Switch -- ED-5000-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; -- -- Enterprise Specific Object Identifiers -- mcData OBJECT IDENTIFIER ::= { enterprises 289 } -- Product lines or generic product information -- common OBJECT IDENTIFIER ::= { mcData 1 } commDev OBJECT IDENTIFIER ::= { mcData 2 } -- communication devices -- Fibre Channel product lines fibreChannel OBJECT IDENTIFIER ::= { commDev 1 } fcSwitch OBJECT IDENTIFIER ::= { fibreChannel 1 } ed-5000 OBJECT IDENTIFIER ::= { fcSwitch 1 } -- textual conventions DisplayString ::= OCTET STRING Ed5000SysOperStatus ::= INTEGER { operational (1), redundant-failure (2), minor-failure (3), major-failure (4), not-operational (5) } Ed5000SysState ::= INTEGER { online (1), coming-online (2), offline (3), going-offline (4) } Ed5000FruCode ::= INTEGER { fru-bkplane (1) , -- Backplane fru-ctp (2) , -- Control Processor card fru-mpc (3) , -- Message Path Controller card fru-cmm (4) , -- Central Memory Module card fru-fan (5) , -- Fan module fru-power (6) , -- Power supply module fru-panel (7) , -- Operator panel fru-gsm (8) , -- G_Port Module card: short wave, multimode (GSM) fru-gls (9) , -- G_Port Module card: long wave, single-mode (GLS) fru-glx (10), -- G_Port Module card: long wave, mixed-mode (GLX) fru-lsm (11), -- L_Port Module card: short wave, multimode (LSM) fru-gxx (12) -- G_Port Module card: combo GSM/GLS (GXX) } Ed5000FruPosition ::= INTEGER (0..255) Ed5000FruStatus ::= INTEGER { active (1), backup (2), update-busy (3), failed (4) } Ed5000PortIndex ::= INTEGER (0..2048) Ed5000PortPhyState ::= INTEGER { psNotInstalled (1), psAvailable (2), psBlocked (3), psUnavailable (4), psLinkFailure (5), psLinkFailLOL (6), psIntDiags (7), psExtLoop (8), psPortFail (9), psSR (10), psLR (11) } Ed5000PortStatus ::= INTEGER { online (1), offline (2), testing (3), faulty (4) } Ed5000PortAdmStatus ::= INTEGER { online (1), offline (2), testing (3) } -- Groups in ED-5000 MIB ed5000Sys OBJECT IDENTIFIER ::= { ed-5000 1 } ed5000Fru OBJECT IDENTIFIER ::= { ed-5000 2 } ed5000Port OBJECT IDENTIFIER ::= { ed-5000 3 } -- reserved OBJECT IDENTIFIER ::= { ed-5000 4 } -- reserved OBJECT IDENTIFIER ::= { ed-5000 5 } -- reserved OBJECT IDENTIFIER ::= { ed-5000 6 } -- reserved OBJECT IDENTIFIER ::= { ed-5000 7 } -- reserved OBJECT IDENTIFIER ::= { ed-5000 8 } -- reserved OBJECT IDENTIFIER ::= { ed-5000 9 } -- -- the System Group -- ed5000SysCurrentDate OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-only STATUS mandatory DESCRIPTION "The current date information." ::= { ed5000Sys 1 } ed5000SysBootDate OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-only STATUS mandatory DESCRIPTION "The date and time of the last IPL" ::= { ed5000Sys 2 } ed5000SysFirmwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (24)) ACCESS read-only STATUS mandatory DESCRIPTION "The current version of the firmware." ::= { ed5000Sys 3 } ed5000SysTypeNum OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies ASCII type number for the unit." ::= { ed5000Sys 4 } ed5000SysModelNum OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies ASCII model number for the unit." ::= { ed5000Sys 5 } ed5000SysMfg OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies ASCII manufacturer for the unit." ::= { ed5000Sys 6 } ed5000SysPlantOfMfg OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies ASCII plant of manufacturer for the unit." ::= { ed5000Sys 7 } ed5000SysSeqNum OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies ASCII sequence number for the unit." ::= { ed5000Sys 8 } ed5000SysEcLevel OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies ASCII EC level ID for the unit." ::= { ed5000Sys 9 } ed5000SysOemSerialNum OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies ASCII OEM serial number for the unit" ::= { ed5000Sys 10 } ed5000SysOperStatus OBJECT-TYPE SYNTAX Ed5000SysOperStatus ACCESS read-only STATUS mandatory DESCRIPTION "The current operational status of the switch. The values are defined as follow: operational (1), redundant-failure (2), minor-failure (3), major-failure (4), not-operational (5)." ::= { ed5000Sys 11 } ed5000SysState OBJECT-TYPE SYNTAX Ed5000SysState ACCESS read-only STATUS mandatory DESCRIPTION "If the edOperStatus of the switch is operational, the switch will be in one of the four states: online(1), coming-online(2), offline(3), and going-offline(4)." ::= { ed5000Sys 12 } ed5000SysAdmStatus OBJECT-TYPE SYNTAX INTEGER { online (1), offline (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The desired administrative status of the switch. A management station may place the switch in a desired state by setting this object accordingly. The desired administrative status are online(1) and offline(2). The online means setting the switch to be accessible by an external Fibre Channel port, and offline means setting the switch to be inaccessible." ::= { ed5000Sys 13 } -- -- End of System Group -- -- -- Fibre Channel FRU Group -- This group contains FRU information of each Fibre Channel Module. -- ed5000FruTable OBJECT-TYPE SYNTAX SEQUENCE OF Ed5000FruEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains one entry for each module." ::= { ed5000Fru 1 } ed5000FruEntry OBJECT-TYPE SYNTAX Ed5000FruEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing the service parameters of the module." INDEX { ed5000FruCode, ed5000FruPosition } ::= { ed5000FruTable 1 } Ed5000FruEntry ::= SEQUENCE { ed5000FruCode Ed5000FruCode, ed5000FruPosition Ed5000FruPosition, ed5000FruStatus Ed5000FruStatus, ed5000FruPartNumber DisplayString (SIZE (64)), ed5000FruSerialNumber DisplayString (SIZE (64)), ed5000FruPowerOnHours Counter, ed5000FruTestDate DisplayString (SIZE (64)) } ed5000FruCode OBJECT-TYPE SYNTAX Ed5000FruCode ACCESS read-only STATUS mandatory DESCRIPTION "Field Replaceable Unit. A hardware component of the product that is replaceable as an entire unit. Each module defined in this MIB has a fixed FRU code. The values are defined as follow: fru-none (0) , fru-bkplane (1), fru-ctp (2), fru-mpc (3), fru-cmm (4), fru-fan (5), fru-power (6), fru-panel (7), fru-gsm (8), fru-gls (9), fru-glx (10), fru-lsm (11), fru-gxx (12)." ::= { ed5000FruEntry 1 } ed5000FruPosition OBJECT-TYPE SYNTAX Ed5000FruPosition ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the position of the module. Port cards start from 1 to 8. All other cards start from 1 to 1 or 2." ::= { ed5000FruEntry 2 } ed5000FruStatus OBJECT-TYPE SYNTAX Ed5000FruStatus ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the operational status of the module. The active(1) state indicates that the current module is active. The backup(2) state indicates that the back up module is used. update-busy (3) state indicates that the module is in the updating process. The failed(4) state indicates that the current module is failed." ::= { ed5000FruEntry 3 } ed5000FruPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the part number of the module." ::= { ed5000FruEntry 4 } ed5000FruSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the serial number of the module." ::= { ed5000FruEntry 5 } ed5000FruPowerOnHours OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the number of the hours that the FRU has been in operation." ::= { ed5000FruEntry 6 } ed5000FruTestDate OBJECT-TYPE SYNTAX DisplayString (SIZE (64)) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates final test date of the module." ::= { ed5000FruEntry 7 } -- -- End of Fibre Channel FRU Group -- -- -- Fibre Channel Port Group -- This group contains information about each Fibre Channel port. -- ed5000PortTable OBJECT-TYPE SYNTAX SEQUENCE OF Ed5000PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that contains one entry for each switch port (stitch only)." ::= { ed5000Port 1 } ed5000PortEntry OBJECT-TYPE SYNTAX Ed5000PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing the information of the switch port." INDEX { ed5000PortIndex } ::= { ed5000PortTable 1 } Ed5000PortEntry ::= SEQUENCE { ed5000PortIndex Ed5000PortIndex, ed5000PortPhyState Ed5000PortPhyState, ed5000PortOpStatus Ed5000PortStatus, ed5000PortAdmStatus Ed5000PortAdmStatus, -- the rest is mapped to gstat_t ed5000PortTxWords Counter, ed5000PortRxWords Counter, ed5000PortTxFrames Counter, ed5000PortRxFrames Counter, ed5000PortRxC2Frames Counter, ed5000PortRxC3Frames Counter, ed5000PortRxLCs Counter, ed5000PortRxMcasts Counter, ed5000PortTooManyRdys Counter, ed5000PortNoTxCredits Counter, ed5000PortRxEncFrs Counter, ed5000PortRxCrcs Counter, ed5000PortRxTruncs Counter, ed5000PortRxTooLongs Counter, ed5000PortRxBadEofs Counter, ed5000PortRxBadOs Counter, ed5000PortC3Discards Counter, ed5000PortMcastTimedOuts Counter, ed5000PortTxMcasts Counter, ed5000PortTxThroughput Counter, ed5000PortRxThroughput Counter } ed5000PortIndex OBJECT-TYPE SYNTAX Ed5000PortIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the switch port." ::= { ed5000PortEntry 1 } ed5000PortPhyState OBJECT-TYPE SYNTAX Ed5000PortPhyState ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the physical state of the port." ::= { ed5000PortEntry 2 } ed5000PortOpStatus OBJECT-TYPE SYNTAX Ed5000PortStatus ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the operational status of the port. The online state indicates that user frames can be passed." ::= { ed5000PortEntry 3 } ed5000PortAdmStatus OBJECT-TYPE SYNTAX Ed5000PortAdmStatus ACCESS read-write STATUS mandatory DESCRIPTION "The desired state of the port. A management station may place the port in a desired state by setting this object accordingly. The testing(3) state indicates that no user frames can be passed. As the result of either explicit management action or per configuration information accessible by the switch, ed5000PortAdmStatus is then changed to either the online(1) or testing(3) states, or remains in the offline state." ::= { ed5000PortEntry 4 } ed5000PortTxWords OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Fibre Channel words that the port has transmitted." ::= { ed5000PortEntry 11 } ed5000PortRxWords OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Fibre Channel words that the port has received." ::= { ed5000PortEntry 12 } -- does this include primitive signals, primitive sequence or -- just words within frames? ed5000PortTxFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of (Fibre Channel) frames that the port has transmitted." ::= { ed5000PortEntry 13 } ed5000PortRxFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of (Fibre Channel) frames that the port has received." ::= { ed5000PortEntry 14 } ed5000PortRxC2Frames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Class 2 frames that the port has received." ::= { ed5000PortEntry 15 } ed5000PortRxC3Frames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Class 3 frames that the port has received." ::= { ed5000PortEntry 16 } ed5000PortRxLCs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Link Control frames that the port has received." ::= { ed5000PortEntry 17 } ed5000PortRxMcasts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Multicast frames that the port has received." ::= { ed5000PortEntry 18 } ed5000PortTooManyRdys OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of 2.26 micro second intervals where the transmission of RDYs has priority over the transmission of frame traffic. (In 2.x releases and below, this counter gets incremented continuously and therefore has no meaning. In release 3.0 and above, it is always 0.)" ::= { ed5000PortEntry 19 } ed5000PortNoTxCredits OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the amount of time that frame transmission is blocked by a transmit credit of zero. This is sampled once every 120 53.125 MHZ clocks, and the counter is incremented by 1 if the condition is true." ::= { ed5000PortEntry 20 } ed5000PortRxEncFrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of encoding error or disparity error inside or outside frames received." ::= { ed5000PortEntry 21 } ed5000PortRxCrcs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of CRC errors detected for frames received." ::= { ed5000PortEntry 22 } ed5000PortRxTruncs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of truncated frames that the port has received." ::= { ed5000PortEntry 23 } ed5000PortRxTooLongs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of received frames that are too long." ::= { ed5000PortEntry 24 } ed5000PortRxBadEofs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of received frames that have bad EOF delimiter." ::= { ed5000PortEntry 25 } ed5000PortRxBadOs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of invalid Ordered Sets received." ::= { ed5000PortEntry 26 } ed5000PortC3Discards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Class 3 frames that the port has discarded." ::= { ed5000PortEntry 27 } ed5000PortMcastTimedOuts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Multicast frames that has been timed out." ::= { ed5000PortEntry 28 } ed5000PortTxMcasts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of Multicast frames that has been transmitted." ::= { ed5000PortEntry 29 } ed5000PortTxThroughput OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object presents the Bps transmission rate." ::= { ed5000PortEntry 30 } ed5000PortRxThroughput OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object presents the Bps reception rate." ::= { ed5000PortEntry 31 } -- -- End of Fibre Channel Port Group -- -- -- ED-5000 Enterprise Specific Trap Definitions -- ed5000PortScn TRAP-TYPE ENTERPRISE mcData VARIABLES { ed5000PortOpStatus } DESCRIPTION "An ed5000PortScn(1) is generated whenever a Fc_Port changes its operational state. For instance, the Fc_Port goes from on-line to offline." ::= 1 ed5000FruScn TRAP-TYPE ENTERPRISE mcData VARIABLES { ed5000FruStatus } DESCRIPTION "An ed5000FruScn(2) is generated whenever a FRU status changes its operational state." ::= 2 END