-- ===================================================================== -- == DIGI-SERIAL-ALARM-TRAPS-MIB : == -- == DIGI Serial Alarm Traps Management Information Base == -- == == -- == Digi International Part Number: 40002411_A == -- == == -- == (c) Copyright 2001-2004 Digi International, Inc. == -- ===================================================================== DIGI-SERIAL-ALARM-TRAPS-MIB DEFINITIONS ::= BEGIN IMPORTS digiSerialAlarmTraps FROM DIGI-SMI TRAP-TYPE FROM RFC-1215 OBJECT-TYPE FROM RFC-1212; -- digiSerialAlarmTraps MODULE-IDENTITY -- LAST-UPDATED "0308120100Z" -- ORGANIZATION "Digi International Inc." -- CONTACT-INFO -- " -- Postal: Digi International Inc. -- 11001 Bren Road East -- Minnetonka, MN 55343 -- -- " -- DESCRIPTION -- "Serial Alarm Traps MIB" -- ::= { digiFeatures 19 } -- === + Textual Conventions + =========================================== DisplayString ::= OCTET STRING -- ======================================================================= -- ======================================================================= -- === + Variables + ===================================================== -- ======================================================================= -- ======================================================================= serialAlarmSubject OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A message describing the serial alarm" ::= { digiSerialAlarmTraps 11 } -- ======================================================================= -- ======================================================================= -- === + Traps + ========================================================= -- ======================================================================= -- ======================================================================= serialAlarmDataPattern TRAP-TYPE ENTERPRISE digiSerialAlarmTraps VARIABLES { serialAlarmSubject } DESCRIPTION "A serialAlarmDataPattern trap signifies that a data pattern match was made on a serial port on the Digi device." ::= 1 serialAlarmTransition TRAP-TYPE ENTERPRISE digiSerialAlarmTraps VARIABLES { serialAlarmSubject } DESCRIPTION "A serialAlarmTransition trap signifies that a set of GPIO pins has transitioned to an alarm defined state on the Digi device." ::= 2 serialAlarmReminder TRAP-TYPE ENTERPRISE digiSerialAlarmTraps VARIABLES { serialAlarmSubject } DESCRIPTION "A serialAlarmReminder trap signifies that a set of GPIO pins has continued to be in an alarm defined state for some defined amount of time on the Digi device." ::= 3 END