-- Version: V1.07 -- -- CREATED: November 19, 1999 -- -- Language: "en|US|iso8859-1" -- -- -- $Id$ -- DESKTRAP-MIB DEFINITIONS ::= BEGIN -- -- Title: MIB for DeskView Trap-Agent -- IMPORTS TRAP-TYPE FROM RFC-1215 OBJECT-TYPE FROM RFC-1212 mib-2, DisplayString FROM RFC1213-MIB TimeTicks, Counter, Gauge, enterprises FROM RFC1155-SMI; sni OBJECT IDENTIFIER ::= { enterprises 231 } sniProductMibs OBJECT IDENTIFIER ::= { sni 2 } sniExtensions OBJECT IDENTIFIER ::= { sniProductMibs 10 } sniDesktopMgmt OBJECT IDENTIFIER ::= { sniExtensions 3 } sniDeskTrap OBJECT IDENTIFIER ::= { sniDesktopMgmt 2 } -- GROUP: "SNI Desktop-Version" sniTrapAgentVersionInformation OBJECT IDENTIFIER ::= { sniDeskTrap 1 } -- Description: "" -- Class: "SNI DESKTRAP|VERION-INFORMATION|1.0 US" sniTrapAgentPurpose OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Purpose of the SNI Desktop-Trap-Agent" ::= { sniTrapAgentVersionInformation 1 } sniTrapAgentVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Version of the SNI Desktop-Trap-Agent" ::= { sniTrapAgentVersionInformation 2 } sniTrapAgentDeskInfoVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Version of SNI Deskinfo" ::= { sniTrapAgentVersionInformation 3 } -- GROUP: "SNI Desktop-Trap-Parameter" sniTrapAgentTrapParameter OBJECT IDENTIFIER ::= { sniDeskTrap 2 } -- Description: "" -- Class: "SNI DESKTRAP|TRAP-PARAMETER|1.0 US" sniTrapDesktop OBJECT-TYPE SYNTAX DisplayString ACCESS not-accessible STATUS mandatory DESCRIPTION "Desktopname" ::= {sniTrapAgentTrapParameter 1 } sniTrapTimeInt OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Systemtime as integer" ::= {sniTrapAgentTrapParameter 2 } sniTrapTimeStr OBJECT-TYPE SYNTAX DisplayString ACCESS not-accessible STATUS mandatory DESCRIPTION "Systemdate as string" ::= {sniTrapAgentTrapParameter 3 } sniTrapAgentStatus OBJECT-TYPE SYNTAX INTEGER { st-unknown ( 0 ), st-ok ( 1 ), st-warning ( 2 ), st-critical ( 3 ) } ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { sniTrapAgentTrapParameter 4 } sniTrapAgentType OBJECT-TYPE SYNTAX INTEGER { t-alert ( 1 ), t-event ( 2 ), t-info ( 3 ) } ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { sniTrapAgentTrapParameter 5 } sniTrapAgentEventName OBJECT-TYPE SYNTAX DisplayString ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { sniTrapAgentTrapParameter 6 } sniTrapAgentEventText OBJECT-TYPE SYNTAX DisplayString ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { sniTrapAgentTrapParameter 7 } sniTrapAgentTimeBIAS OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= {sniTrapAgentTrapParameter 8 } sniTrapAgentSystemStatus OBJECT-TYPE SYNTAX INTEGER { st-unknown ( 0 ), st-ok ( 1 ), st-warning ( 2 ), st-critical ( 3 ) } ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= {sniTrapAgentTrapParameter 9 } sniTrapAgentClassStatus OBJECT-TYPE SYNTAX INTEGER { st-unknown ( 0 ), st-ok ( 1 ), st-warning ( 2 ), st-critical ( 3 ) } ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= {sniTrapAgentTrapParameter 10 } -- Begin Trap Definition -- 1 = ErrorTrap sniTrapError TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "No Text found in DeskMon.ini" --#TYPE "No Text found in DeskMon.ini" --#SUMMARY "No Text found in DeskMon.ini on %s" --#ARGUMENTS { 0 } --#SEVERITY WARNING --#TIMEINDEX 1 ::= 1 -- 1xxx = SMART sniSmartOK TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "SMART hard disk reports OK." --#TYPE "SMART hard disk reports OK" --#SUMMARY "SMART hard disk reports OK on %s" --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 1001 sniSmartWarning TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "SMART hard disk reports Warning." --#TYPE "SMART hard disk reports Warning" --#SUMMARY "SMART hard disk reports Warning on %s" --#ARGUMENTS { 0 } --#SEVERITY WARNING --#TIMEINDEX 1 ::= 1002 sniSmartError TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "SMART hard disk reports Error." --#TYPE "SMART hard disk reports Error." --#SUMMARY "SMART hard disk reports Error on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 1003 -- 2xxx = Cover open/closed sniCoverClosed TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The cover is closed" --#TYPE "The cover is closed" --#SUMMARY "The cover is closed on %s" --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 2001 sniCoverOpened TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The cover has been opened." --#TYPE "The cover has been opened." --#SUMMARY "The cover has been opened on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 2003 -- 3xxx = Cover sensor sniCoverSensorincorporated TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The sensor for securing the cover is incorporated." --#TYPE "The sensor for securing the cover is incorporated." --#SUMMARY "The sensor for securing the cover is incorporated on %s" --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 3001 sniCoverSensorMissing TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The sensor for securing the cover is missing or defective" --#TYPE "The sensor for securing the cover is missing or defective" --#SUMMARY "The sensor for securing the cover is missing or defective on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 3003 -- 4xxx = Cover recognition sniCoverRecognition TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The cover type cannot be recognized." --#TYPE "The cover type cannot be recognized." --#SUMMARY "The cover type cannot be recognized on %s" --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 4001 sniCoverRecognitionMissing TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The sensor for recognizing the cover type is missing or defective." --#TYPE "The sensor for recognizing the cover type is missing or defective." --#SUMMARY "The sensor for recognizing the cover type is missing or defective on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 4003 -- 5xxx = Short circuit sniNoShortCurcuit TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "No short circuit in the mouse, keyboard or USB interface." --#TYPE "No short circuit in the mouse, keyboard or USB interface." --#SUMMARY "No short circuit in the mouse, keyboard or USB interface on %s" --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 5001 sniShortCurcuit TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Short circuit in the mouse, keyboard or USB interface." --#TYPE "Short circuit in the mouse, keyboard or USB interface." --#SUMMARY "Short circuit in the mouse, keyboard or USB interface on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 5003 -- 7xxx = Temperature sniTemperatureOK TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The temperature sensor is functioning" --#TYPE "The temperature sensor is functioning" --#SUMMARY "The temperature sensor is functioning on %s" --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 7001 sniTemperatureWarning TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The temperature is high" --#TYPE "The temperature is high" --#SUMMARY "The temperature is high on %s" --#ARGUMENTS { 0 } --#SEVERITY WARNING --#TIMEINDEX 1 ::= 7002 sniTemperatureCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The temperature sensor is defective or the temperature is too high" --#TYPE "The temperature sensor is defective or the temperature is too high" --#SUMMARY "The temperature sensor is defective or the temperature is too high on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 7003 -- 8xxx = Fan monitoring sniFanRunning TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The fan is running" --#TYPE "The fan is running" --#SUMMARY "The fan is running on %s" --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 8001 sniFanNotRunning TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The fan is not running" --#TYPE "The fan is not running" --#SUMMARY "The fan is not running on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 8003 -- 9xxx = Fan is getting worn sniFanWornOK TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The rotational speed of the fan is OK." --#TYPE "The rotational speed of the fan is OK." --#SUMMARY "The rotational speed of the fan is OK on %s" --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 9001 sniFanWornWarning TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The rotational speed of the fan is almost critical." --#TYPE "The rotational speed of the fan is almost critical." --#SUMMARY "The rotational speed of the fan is almost critical on %s" --#ARGUMENTS { 0 } --#SEVERITY WARNING --#TIMEINDEX 1 ::= 9002 sniFanWornCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The rotational speed of the fan is critical." --#TYPE "The rotational speed of the fan is critical." --#SUMMARY "The rotational speed of the fan is critical on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 9003 -- 11xxx = Voltage sniVoltageOk TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The voltage monitor is functioning." --#TYPE "The voltage monitor is functioning." --#SUMMARY "The voltage monitor is functioning on %s" --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 11001 sniVoltageWarning TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The voltage is almost critical." --#TYPE "The voltage is almost critical." --#SUMMARY "The voltage is almost critical on %s" --#ARGUMENTS { 0 } --#SEVERITY WARNING --#TIMEINDEX 1 ::= 11002 sniVoltageCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The voltage monitor is not functioning or the voltage is critical." --#TYPE "The voltage monitor is not functioning or the voltage is critical." --#SUMMARY "The voltage monitor is not functioning or the voltage is critical on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 11003 -- 12xxx = Watchdog sniWatchdogOk TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The functionality of the operating system watchdog is guaranteed." --#TYPE "The functionality of the operating system watchdog is guaranteed." --#SUMMARY "The functionality of the operating system watchdog is guaranteed on %s" --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 12001 sniWatchdogCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The operating system watchdog caused too many consecutive system reboots and will be deactivated." --#TYPE "The operating system watchdog caused too many consecutive system reboots and will be deactivated." --#SUMMARY "The operating system watchdog caused too many consecutive system reboots and will be deactivated on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 12003 -- 13xxx = Internal error sniInternalError TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Messages for system monitoring got lost because they could not be buffered!. The buffer has overrun or the harddisk was full." --#TYPE "Messages for system monitoring got lost because they could not be buffered!. The buffer has overrun or the harddisk was full." --#SUMMARY "Messages for system monitoring got lost because they could not be buffered!. The buffer has overrun or the harddisk was full on %s." --#ARGUMENTS { 0 } --#SEVERITY WARNING --#TIMEINDEX 1 ::= 13001 -- 14xxx = BIOSErrorLog sniBIOSErrorLogOK TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "BIOS error log contains no current entries" --#TYPE "BIOS error log contains no current entries" --#SUMMARY "BIOS error log contains no current entries on %s" --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 14001 sniBIOSErrorLogWarning TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "BIOS reported a non-critical problem" --#TYPE "BIOS reported a non-critical problem" --#SUMMARY "BIOS reported a non-critical problem on %s" --#ARGUMENTS { 0 } --#SEVERITY WARNING --#TIMEINDEX 1 ::= 14002 sniBIOSErrorLogCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "BIOS reported a critical error" --#TYPE "BIOS reported a critical error" --#SUMMARY "BIOS reported a critical error on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 14003 -- 15xxx = P.O.S.T. Error sniAOLPOSTCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Power On Self Test (POST) error." --#TYPE "Power On Self Test (POST) error." --#SUMMARY "Power On Self Test (POST) error on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 15003 -- 16xxx = Watchdog sniAOLWatchdogCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The operating system may be hung or the computer failed to boot." --#TYPE "The operating system may be hung or the computer failed to boot." --#SUMMARY "The operating system may be hung or the computer failed to boot on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 16003 -- 17xxx = Cover opening sniAOLCoverOpened TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The cover was opened." --#TYPE "The cover was opened." --#SUMMARY "The cover was opened on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 17003 -- 18xxx = CPU Missing sniAOLCPUMissingCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The processor was removed from the computer." --#TYPE "The processor was removed from the computer." --#SUMMARY "The processor was removed from the computer %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 18003 -- 20xxx = Heartbeat expired sniAOLHeartbeatCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The computer is no longer available. (Presence Heartbeat Expired)." --#TYPE "The computer is no longer available. (Presence Heartbeat Expired)." --#SUMMARY "The computer %s is no longer available. (Presence Heartbeat Expired)" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 20003 -- 21xxx = Free hard disk space sniFreeDiskSpaceOK TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Free hard disk space is sufficient." --#TYPE "Free hard disk space is sufficient." --#SUMMARY "Free hard disk space is sufficient on %s." --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 21001 sniFreeDiskSpaceWarning TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Free hard disk space is low." --#TYPE "Free hard disk space is low." --#SUMMARY "Free hard disk space is low on %s." --#ARGUMENTS { 0 } --#SEVERITY WARNING --#TIMEINDEX 1 ::= 21002 sniFreeDiskSpaceError TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Free hard disk space is extremely low." --#TYPE "Free hard disk space is extremely low." --#SUMMARY "Free hard disk space is extremely low on %s." --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 21003 -- 22xxx = Memory changes sniMemoryChangesOK TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The memory size has not changed." --#TYPE "The memory size has not changed." --#SUMMARY "The memory size has not changed on %s." --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 22001 sniMemoryChangesWarning TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The memory size increased." --#TYPE "The memory size increased." --#SUMMARY "The memory size increased on %s." --#ARGUMENTS { 0 } --#SEVERITY WARNING --#TIMEINDEX 1 ::= 22002 sniMemoryChangesError TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The memory size decreased low." --#TYPE "The memory size decreased." --#SUMMARY "The memory size decreased on %s." --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 22003 -- 23xxx = Device changes sniDeviceChangesOK TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "No changes in devices." --#TYPE "No changes in devices." --#SUMMARY "No changes in devices on %s." --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 23001 sniDeviceChangesWarning TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "A device was added to the system." --#TYPE "A device was added to the system." --#SUMMARY "A device was added to system %s." --#ARGUMENTS { 0 } --#SEVERITY WARNING --#TIMEINDEX 1 ::= 23002 sniDeviceChangesError TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "A device was removed from the system." --#TYPE "A device was removed from the system." --#SUMMARY "A device was removed from system %s." --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 23003 -- 24xxx = Voltage/Fan/Temperature sniAOLVoltage-Fan-TemperatureCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "A Voltage/Fan/Temperature is operating out of specification." --#TYPE "A Voltage/Fan/Temperature is operating out of specification." --#SUMMARY "A Voltage/Fan/Temperature is operating out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 24003 -- 25xxx = LAN Leash sniAOLLANLeashCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The computer was recently reconnected to the network." --#TYPE "The computer was recently reconnected to the network." --#SUMMARY "The computer was recently reconnected to the network on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 25003 -- 26xxx = Processor temperature sniAOLProcessorTemperatureCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The processor temperature is out of specification." --#TYPE "The processor temperature is out of specification." --#SUMMARY "The processor temperature is out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 26003 -- 28xxx = Processor 0 Missing sniAOLProcessor0MissingCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The processor P0 was removed from the computer." --#TYPE "The processor P0 was removed from the computer." --#SUMMARY "The processor P0 was removed from the computer on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 28003 -- 29xxx = Processor 1 Missing sniAOLProcessor1MissingCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The processor P1 was removed from the computer." --#TYPE "The processor P1 was removed from the computer." --#SUMMARY "The processor P1 was removed from the computer on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 29003 -- 30xxx = Voltage/Fan sniAOLVoltage-FanCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "A Voltage/Fan is operating out of specification." --#TYPE "A Voltage/Fan is operating out of specification." --#SUMMARY "A Voltage/Fan is operating out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 30003 -- 31xxx = Voltage sniAOLVoltageCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "A Voltage is operating out of specification." --#TYPE "A Voltage is operating out of specification." --#SUMMARY "A Voltage is operating out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 31003 -- 32xxx = Fan sniAOLFanCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "A Fan is operating out of specification." --#TYPE "A Fan is operating out of specification." --#SUMMARY "A Fan is operating out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 32003 -- 33xxx = Fan/Temperature sniAOLFan-TemperatureCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "A Fan/Temperature is operating out of specification." --#TYPE "A Fan/Temperature is operating out of specification." --#SUMMARY "A Fan/Temperature is operating out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 33003 -- 34xxx = Voltage/Temperature sniAOLVoltage-TemperatureCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "A Voltage/Temperature is operating out of specification." --#TYPE "A Voltage/Temperature is operating out of specification." --#SUMMARY "A Voltage/Temperature is operating out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 34003 -- 35xxx = NIC SMBus slot sniAOLNICSMBusSlotCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "NIC with Capelookout has been plugged into a PCI slot without SMBus connection." --#TYPE "NIC with Capelookout has been plugged into a PCI slot without SMBus connection." --#SUMMARY "NIC with Capelookout has been plugged into a PCI slot without SMBus connection on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 35003 -- 36xxx = Presence Pong sniAOLPresencePongCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Received a presence pong reply." --#TYPE "Received a presence pong reply." --#SUMMARY "Received a presence pong reply on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 36003 -- 37xxx = Hardware Monitor sniAOLHardwareMonitorCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Hardware Monitor has detected an external event." --#TYPE "Hardware Monitor has detected an external event." --#SUMMARY "Hardware Monitor has detected an external event on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 37003 -- 38xxx = +1.5V GTL Voltage sniAOL1-5VGTLVoltageCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "+1.5 GTL Voltage is out of specification." --#TYPE "+1.5 GTL Voltage is out of specification." --#SUMMARY "+1.5 GTL Voltage is out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 38003 -- 39xxx = CPU Core Voltage sniAOLCPUCoreVoltageCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "CPU Core Voltage is out of specification." --#TYPE "CPU Core Voltage is out of specification." --#SUMMARY "CPU Core Voltage is out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 39003 -- 40xxx = +3.3V Standby sniAOL3-3VStandbyCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "+3.3V Standby Voltage is out of specification." --#TYPE "+3.3V Standby Voltage is out of specification." --#SUMMARY "+3.3V Standby Voltage is out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 40003 -- 41xxx = +5 Voltage sniAOL5VoltageCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "+5V Voltage is out of specification." --#TYPE "+5V Voltage is out of specification." --#SUMMARY "+5V Voltage is out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 41003 -- 42xxx = Hardware Monitor Internal Temperature sniAOLHardwareMonitorInternalTemperatureCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Hardware Monitor Internal Temperature is out of specification." --#TYPE "Hardware Monitor Internal Temperature is out of specification." --#SUMMARY "Hardware Monitor Internal Temperature is out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 42003 -- 43xxx = CPU Diode Sensor sniAOLCPUDiodeSensorCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "CPU Diode Sensor is operating out of specification." --#TYPE "CPU Diode Sensor is operating out of specification." --#SUMMARY "CPU Diode Sensor is operating out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 43003 -- 44xxx = CPU Fan sniAOLCPUFanCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "CPU Fan is operating out of specification." --#TYPE "CPU Fan is operating out of specification." --#SUMMARY "CPU Fan is operating out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 44003 -- 45xxx = Chassis Fan sniAOLChassisFanCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Chassis Fan is operating out of specification." --#TYPE "Chassis Fan is operating out of specification." --#SUMMARY "Chassis Fan is operating out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 45003 -- 46xxx = +12 Voltage sniAOL12VoltageCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "+12V is operating out of specification." --#TYPE "+12V is operating out of specification." --#SUMMARY "+12V is operating out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 46003 -- 47xxx = +3.3 Voltage sniAOL3-3VoltageCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "+3.3V is operating out of specification." --#TYPE "+3.3V is operating out of specification." --#SUMMARY "+3.3V is operating out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 47003 -- 48xxx = CPU Diode sniAOLCPUDiodeCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Open/Short has occurred in the CPU Diode Sensor." --#TYPE "Open/Short has occurred in the CPU Diode Sensor." --#SUMMARY "Open/Short has occurred in the CPU Diode Sensor on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 48003 -- 49xxx = +2.5 Voltage sniAOL2-5VoltageCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "+2.5V is operating out of specification." --#TYPE "+2.5V is operating out of specification." --#SUMMARY "+2.5V is operating out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 49003 -- 50xxx = Ambient Temperature sniAOLAmbientTemperatureCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Ambient temperature is out of specification." --#TYPE "Ambient temperature is out of specification." --#SUMMARY "Ambient temperature is out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 50003 -- 51xxx = Remote Temperature sniAOLRemoteTemperatureCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Remote Temperature is out of specification." --#TYPE "Remote Temperature is out of specification." --#SUMMARY "Remote Temperature is out of specification on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 51003 -- 52xxx = Undock event sniAOLUndockEventCritical TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Surprised undock event (no information is available)." --#TYPE "Surprised undock event (no information is available)." --#SUMMARY "Surprised undock event (no information is available) on %s" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 52003 -- 56xxx = Free system disk space sniFreeSystemDiskSpaceOK TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Free hard disk space on system disk is sufficient." --#TYPE "Free hard disk space on system disk is sufficient." --#SUMMARY "Free hard disk space on system disk is sufficient on %s." --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 56001 sniFreeSystemDiskSpaceWarning TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Free hard disk space on system disk is low." --#TYPE "Free hard disk space on system disk is low." --#SUMMARY "Free hard disk space on system disk is low on %s." --#ARGUMENTS { 0 } --#SEVERITY WARNING --#TIMEINDEX 1 ::= 56002 sniFreeSystemDiskSpaceError TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "Free hard disk space on system disk is extremely low." --#TYPE "Free hard disk space on system disk is extremely low." --#SUMMARY "Free hard disk space on system disk is extremely low on %s." --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 56003 -- 57xxx = Lease expiration sniLeaseExpirationOK TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The lease contract has not yet expired or no expiration date has been set." --#TYPE "The lease contract has not yet expired or no expiration date has been set." --#SUMMARY "The lease contract has not yet expired or no expiration date has been set on %s." --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 57001 sniLeaseExpirationWarning TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The lease contract will expire soon." --#TYPE "The lease contract will expire soon." --#SUMMARY "The lease contract will expire soon on %s." --#ARGUMENTS { 0 } --#SEVERITY WARNING --#TIMEINDEX 1 ::= 57002 sniLeaseExpirationError TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "The lease contract has expired." --#TYPE "The lease contract has expired." --#SUMMARY "The lease contract has expired on %s." --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 57003 -- 58xxx = Processor change sniProcessorChangeOK TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "No processor change determined." --#TYPE "No processor change determined." --#SUMMARY "No processor change determined on %s." --#ARGUMENTS { 0 } --#SEVERITY NORMAL --#TIMEINDEX 1 ::= 58001 sniProcessorChangeWarning TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "A processor has also been installed or replaced." --#TYPE "A processor has also been installed or replaced." --#SUMMARY "A processor has also been installed or replaced on %s." --#ARGUMENTS { 0 } --#SEVERITY WARNING --#TIMEINDEX 1 ::= 58002 sniProcessorChangeError TRAP-TYPE ENTERPRISE sniDesktopMgmt VARIABLES { sniTrapDesktop, sniTrapTimeInt, sniTrapTimeStr, sniTrapAgentStatus, sniTrapAgentType, sniTrapAgentEventName,sniTrapAgentEventText, sniTrapAgentTimeBIAS, sniTrapAgentSystemStatus, sniTrapAgentClassStatus } DESCRIPTION "A processor has been removed." --#TYPE "A processor has been removed." --#SUMMARY "A processor has been removed on %s." --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 ::= 58003 END