CXV34-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB cxV34, SapIndex, Alias FROM CXProduct-SMI; -- Configuration Table -- The table describing: -- parameters used to configure each V34 slot and its associated hardware -- port. v34SlotTable OBJECT-TYPE SYNTAX SEQUENCE OF V34SlotEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Describes a table that contains configuration information about each V34 modem and its associated hardware port." ::= { cxV34 1 } v34SlotEntry OBJECT-TYPE SYNTAX V34SlotEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Describes the configuration information applied to a specific V34 modem and its associated hardware port." INDEX { v34SlotNumber } ::= { v34SlotTable 1 } V34SlotEntry ::= SEQUENCE { v34SlotNumber SapIndex, v34SlotAlias Alias, v34SlotRowStatus INTEGER, v34SlotStatus INTEGER, v34SlotAnswerMode INTEGER, v34SlotModemString DisplayString(SIZE (0..32)), v34SlotDialNumber DisplayString, v34SlotSpeedStatus INTEGER, v34SlotRetrainStatus INTEGER, v34SlotHookStatus INTEGER, v34SlotRingStatus INTEGER, v34SlotDsrStatus INTEGER, v34SlotDtrStatus INTEGER, v34SlotModel INTEGER, v34SlotRevision INTEGER, v34SlotEco INTEGER } v34SlotNumber OBJECT-TYPE SYNTAX SapIndex ACCESS read-only STATUS mandatory DESCRIPTION "Identifies a numerical value applied to the modem. Each device has a unique number." ::= { v34SlotEntry 1 } v34SlotAlias OBJECT-TYPE SYNTAX Alias ACCESS read-write STATUS mandatory DESCRIPTION "Assigns a name used for the alias. Each modem requires a unique name. You may not assign the same name twice. Default Value: none Range of Values: Up to twelve alphanumeric characters, the first character must be alphabetic. Configuration Changed: operative" ::= { v34SlotEntry 2 } v34SlotRowStatus OBJECT-TYPE SYNTAX INTEGER { invalid (1), valid (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the status of the objects in in a table row. Default Value: none Options: invalid (1): row is flagged, after next reset the values will be disabled and the row will be deleted from the table. valid (2): values are enabled Configuration Changed: administrative" ::= { v34SlotEntry 3 } v34SlotStatus OBJECT-TYPE SYNTAX INTEGER { v34-not-present (1), v34-present (2), v34-present-failed (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the presence or absence of a V.34 modem in the slot and if present, whether it has failed initialization. Default Value: none Options: v34-not-present (1) v34-present (2) v34-present-failed (3)" ::= { v34SlotEntry 4 } v34SlotModemString OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Determines a string to be sent to the modem upon initialization. Default Value: none Range of Values: 0-32 alphanumberic characters Configuration Changed: administrative" ::= { v34SlotEntry 5 } v34SlotDialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the number used to dial the remote modem. Default Value: none Range of Values: An octet string of 12 numeric characters Configuration Changed: administrative" ::= { v34SlotEntry 6 } v34SlotAnswerMode OBJECT-TYPE SYNTAX INTEGER { answer-disabled (1), answer-enabled (2), test-mode (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines whether the device will answer an incoming call. Default Value: answer-enabled (2) Options: answer-disabled (1) answer-enabled (2) test-mode (3) Configuration Changed: operative" DEFVAL { answer-enabled } ::= { v34SlotEntry 7 } v34SlotSpeedStatus OBJECT-TYPE SYNTAX INTEGER { speed-0-300 (1), speed-600 (2), speed-1200 (3), speed-2400 (4), speed-4800 (5), speed-7200 (6), speed-9600 (7), speed-12000 (8), speed-14400 (9), speed-16800 (10), speed-19200 (11), speed-21600 (12), speed-24000 (13), speed-26400 (14), speed-28800 (15) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the connection rate operative during the current dial call only. Default Value: none Options: speed-0-300 (1) speed-600 (2) speed-1200 (3) speed-2400 (4) speed-4800 (5) speed-7200 (6) speed-9600 (7) speed-12000 (8) speed-14400 (9) speed-16800 (10) speed-19200 (11) speed-21600 (12) speed-24000 (13) speed-26400 (14) speed-28800 (15) " ::= { v34SlotEntry 8 } v34SlotRetrainStatus OBJECT-TYPE SYNTAX INTEGER { no-retraining (1), retraining (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies whether the modem is retraining or not. It is only applicable while the modem is on-line. Default Value: none Options: no-retraining (1) retraining (2)" ::= { v34SlotEntry 9 } v34SlotHookStatus OBJECT-TYPE SYNTAX INTEGER { on-hook (1), off-hook (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies whether the modem is 'off-hook' (connected to the telephone line), or 'on-hook' (disconnected). Default Value: none Options: on-hook (1) off-hook (2)" ::= { v34SlotEntry 10 } v34SlotRingStatus OBJECT-TYPE SYNTAX INTEGER { no-ring (1), ring (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies when the modem detects a ring signal from the telephone line. Default Value: none Options: no-ring (1) ring (2)" ::= { v34SlotEntry 11 } v34SlotDsrStatus OBJECT-TYPE SYNTAX INTEGER { dsr-deasserted (1), dsr-asserted (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the data transfer state of the modem by the status of the Data Set Ready (DSR) signal . Default Value: none Options dsr-deasserted (1): data transfer inactive dsr-asserted (2): data transfer active" ::= { v34SlotEntry 12 } v34SlotDtrStatus OBJECT-TYPE SYNTAX INTEGER { dtr-deasserted (1), dtr-asserted (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the status of the Data Terminal Ready (DTR) signal that the motherboard uses to dial the pre-stored phone number (if in originate mode) or to enable auto answer (if in answer mode). Default Value: none Options: dtr-deasserted (1) dtr-asserted (2)" ::= { v34SlotEntry 13 } v34SlotModel OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the model number of the Printed Circuit Board (PCB) as an integer value from 0 to 7. Default Value: none Range of Values: 0-7" ::= { v34SlotEntry 14 } v34SlotRevision OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the revision number of the PCB as an integer value from 0 to 15. Default Value: none Range of Values: 0-15" ::= { v34SlotEntry 15 } v34SlotEco OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the Engineering Change Order (ECO) level of the PCB as an integer value from 0 to 15. Default Value: none Range of Values: 0-15" ::= { v34SlotEntry 16 } END