CXMCVOX-MIB DEFINITIONS ::= BEGIN -- -- -- -- -- cxMcVox VOICE CORE MIB -- -- starting point: MIB rev.1.4 -- includes: All options already implemented in the MIB rev.1.4 -- All configuration objects in "private mode" -- note: This MIB is shared by all voice products (AC600, CX900, -- DI600, AI600, ....). -- -- --#CURRENT-VERSION 11 IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString FROM RFC1213-MIB cxMc600 FROM CXProduct-SMI cxModuleHwPhysSlot FROM CXModuleHardware-MIB; cxMcVox OBJECT IDENTIFIER ::= { cxMc600 2 } -- ================================================================== -- cxMcVox GLOBAL CONFIGURATION GROUP. cxMcVoxGlobal OBJECT IDENTIFIER ::= {cxMcVox 1 } -- obsolete: The Administrative Path Length commands -- are now in the Administrative Path table. cxMcVoxGlobalAdmPathLng OBJECT-TYPE SYNTAX INTEGER (2..4) ACCESS read-write STATUS obsolete DESCRIPTION "obsolete. The ReinitNet/ReinitPath commands have been replaced by ReinitRouting." DEFVAL { 3 } ::= { cxMcVoxGlobal 1 } -- obsolete: The ReinitNet/ReinitPath commands -- have been replaced by ReinitRouting cxMcVoxGlobalReinitPath OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS obsolete DESCRIPTION "The ReinitNet/ReinitPath commands have been replaced by ReinitRouting. " DEFVAL { no } ::= { cxMcVoxGlobal 2 } cxMcVoxGlobalClearPath OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS deprecated DESCRIPTION "Path ID no longer exists with the new voice routing scheme Determines whether to restore all administrative Path IDs to the default factory settings. The setting of this object is dynamic. When set to 'yes' all administrative Path IDs will immediately change to the factory defaults. Options: no (1) yes (2) Default Value: no (1) Configuration Change: administrative (Voice Routing or VR)." DEFVAL { no } --#ENDING-VERSION 1 ::= { cxMcVoxGlobal 3 } -- obsolete: The ReinitNet/ReinitPath commands -- have been replaced by ReinitRouting cxMcVoxGlobalReinitNet OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS obsolete DESCRIPTION "The ReinitNet/ReinitPath commands have been replaced by ReinitRouting." DEFVAL { no } ::= { cxMcVoxGlobal 4 } cxMcVoxGlobalClearNet OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS deprecated DESCRIPTION "Network ID no longer exists in the new voice routing scheme (Voice Routing or VR). Determines whether to restore all administrative routing entries (i.e. network routing entries, Path IDs and Group IDs) to the default factory settings. The setting of this object is dynamic. When set to 'yes' all administrative routing entries will immediately change to the factory defaults. Options: no (1) yes (2) Default Value: no (1) Configuration Changed: administrative" DEFVAL { no } --#ENDING-VERSION 1 ::= { cxMcVoxGlobal 5 } cxMcVoxGlobalAdmLocalId OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-write STATUS optional DESCRIPTION "Determines the administrative ID (name) for the local voice station. Note: This object must be defined in order to obtain a successful voice connection. Range of Values: a maximum of 10 alphanumeric characters in upper-case only. You can use any combination of letters and numbers; however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none Configuration Changed: administrative" DEFVAL { " " } ::= { cxMcVoxGlobal 6 } cxMcVoxGlobalOpeLocalId OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only STATUS optional DESCRIPTION "Displays the operative ID (name) for the local voice station. Note: This object must be defined in order to obtain a successful voice connection. You cannot modify this object. If you want to change the ID you must modify the object cxMcVoxGlobalAdmLocalId (of this table). Range of Values: a maximum of 10 alphanumeric characters in upper-case only. You can use any combination of letters and numbers; however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none" ::= { cxMcVoxGlobal 7 } cxMcVoxGlobalTensionRing OBJECT-TYPE SYNTAX INTEGER { down (1), up (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the state of the ring generator power supply. The power supply resides on the ring generator card located on the voice I/O card. You cannot modify this object. Options: down (1) up (2) Default Value: none" ::= { cxMcVoxGlobal 8 } cxMcVoxGlobalTensionDc OBJECT-TYPE SYNTAX INTEGER { down (1), up (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the state of the DC power supply on the voice I/O card. Options: down (1): The DC power supply on the voice I/O card is down. up (2):The DC power supply on the voice I/O card is up. Default Value: none" ::= { cxMcVoxGlobal 9 } cxMcVoxGlobalTrapRing OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines if the ring generator power supply trap is generated. The setting of this object is dynamic. When set to 'enable', the SNMP agent immediately begins to monitor the ring generator power supply. Options: disable (1): No trap is generated. enable (2): Causes a trap message to be sent to the network management console each time a change occurs in the functional state (i.e., up or down) of the ring generator power supply. Default Value: disable (1) Configuration Changed: operative" DEFVAL { disable } --#STARTING-VERSION 5 ::= { cxMcVoxGlobal 10 } cxMcVoxGlobalTrapDc OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines if the DC power supply trap is generated. The setting of this object is dynamic. When set to 'enable', the SNMP agent immediately begins to monitor the DC power supply. Options: disable (1): No trap is generated. enable (2): Causes a trap message to be sent to the network management consoleto each time a change occurs in the functional state (i.e., up or down) of the voice I/O card DC power supply. Default Value: disable (1) Configuration Changed: operative" DEFVAL { disable } --#STARTING-VERSION 5 ::= { cxMcVoxGlobal 11 } cxMcVoxGlobalAdmGrpNbPoll OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-write STATUS deprecated DESCRIPTION "The maximum number of remote voice station(s) that the the local voice station polls within a single call request has been moved from the Global Parameters group to the Group ID Entries group. Determines the maximum number of remote voice stations that the local voice station polls with a single call request. Note: This object is only relevant if at least one Group ID has been defined using the objects in the cxMcVox Administrative Grp Group. Range of Values: 1 to 20 Default Value: 4 Configuration Changed: administrative" DEFVAL { 4 } --#ENDING-VERSION 1 ::= { cxMcVoxGlobal 12 } cxMcVoxGlobalOpeGrpNbPoll OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-only STATUS deprecated DESCRIPTION "The the maximum number of remote voice stations the local voice station polls with a single call request. has been moved from the Global Parameters group to the Group ID Entries group. Displays the maximum number of remote voice stations the local voice station polls with a single call request. Note: This object is only relevant if at least one Group ID has been defined with the objects in the cxMcVox Administrative Grp Group Table. You cannot modify this object. If you want to change this value you must modify the object cxMcVoxGlobalAdmNbPoll (of this table). Range of Values: 1 to 20 Default Value: 4" --#ENDING-VERSION 1 ::= { cxMcVoxGlobal 13 } cxMcVoxGlobalClearGrp OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS optional DESCRIPTION "Determines whether to restore all administrative Group IDs to the default factory settings. The setting of this object is dynamic. When set to 'yes' all administrative Group IDs will immediately change to the factory defaults. Options: no (1) yes (2) Default Value: no Configuration Changed: administrative" DEFVAL { no } ::= { cxMcVoxGlobal 14 } -- obsolete: The Operational Path Length commands -- are now in the Operational Path table. cxMcVoxGlobalOpePathLng OBJECT-TYPE SYNTAX INTEGER (2..4) ACCESS read-only STATUS obsolete DESCRIPTION "The Operational Path Length commands are now in the Operational Path table." DEFVAL { 3 } ::= { cxMcVoxGlobal 15 } cxMcVoxGlobalReinitRouting OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS optional DESCRIPTION "Triggers the reinitialization of the operative routing table. The setting of this object is dynamic. When set to 'yes', all administrative routing, path and group entries will be written to the operative routing table (i.e. will be in the active global configuration). Options: no (1) yes (2) Default Value: no (1) Configuration Changed: operative" DEFVAL { no } ::= { cxMcVoxGlobal 16 } cxMcVoxGlobalForceDefConfig OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS optional DESCRIPTION "Determines whether the default factory configuration will replace both the administrative and operative configurations. The setting of this object is dynamic. When set to 'yes', this object triggers the immediate reconfiguration of all objects to the default factory settings. Options: no (1) yes (2) Default Value: no (1) Configuration Changed: administrative" DEFVAL { no } ::= { cxMcVoxGlobal 17 } cxMcVoxGlobalReinitPinTable OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS optional DESCRIPTION "Saves the PIN table configuration in non-volatile memory, but only enables it if the object cxMcVoxGlobalAdmEnablePinTable is set to 'yes'. Options: no (1) yes (2) Default Value: no (1)" DEFVAL { no } --#STARTING-VERSION 4 ::= { cxMcVoxGlobal 18 } cxMcVoxGlobalAdmEnablePinTable OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS optional DESCRIPTION "Specifies whether the voice station verifies PIN (Personal Identification Numbers) codes before allowing a connection to be established. Options: no (1) yes (2) Default Value: no (1)" DEFVAL { no } --#STARTING-VERSION 4 ::= { cxMcVoxGlobal 19 } cxMcVoxGlobalOpeEnablePinTable OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-only STATUS optional DESCRIPTION "Displays the operational state of PIN verification. Options: no (1) yes (2) Default Value: no (1)" DEFVAL { no } --#STARTING-VERSION 4 ::= { cxMcVoxGlobal 20 } cxMcVoxGlobalReinitCodesTable OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS optional DESCRIPTION "Copy the planned zone code configuration table into active zone code table (non-volatile memory). Options: no (1) yes (2) Default Value: no (1)" DEFVAL { no } --#STARTING-VERSION 3 ::= { cxMcVoxGlobal 21 } cxMcVoxGlobalAdmEnableCodesTable OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS optional DESCRIPTION "The CX900 does not currently support this object. Specifies whether the voice station verifies incoming telephone codes against its internal remote translation table. Options: no (1) yes (2) Default Value: no (1)" DEFVAL { no } ::= { cxMcVoxGlobal 22 } cxMcVoxGlobalOpeEnableCodesTable OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-only STATUS optional DESCRIPTION "The CX900 does not currently support this object. Displays the operational state of the remote translation table. Options: no (1) yes (2) Default Value: none" ::= { cxMcVoxGlobal 23 } cxMcVoxGlobalSoftRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-only STATUS optional DESCRIPTION "Displays the software revision of the local voice station . You cannot modify this object. It is a display that the software provides. Range of Values: a maximum of 30 alphanumeric characters Default Value: none" ::= { cxMcVoxGlobal 24 } --(!!!13 - cxMcVoxGlobalAcelpRev REMOVED and replaced by -- 2 new objects in the cxMcVoxCfgTable; see entries 14 and 15) -- DO NOT INSERT ANY OBJECT HERE ***************** -- ADVANCED MODE OBJECTS (index from 100) cxMcVoxGlobalGlmInBetwReqTime OBJECT-TYPE SYNTAX INTEGER (10..2000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 2000 Default Value: 500" DEFVAL { 500 } ::= { cxMcVoxGlobal 100 } cxMcVoxGlobalGlmMaxTimeToTxReq OBJECT-TYPE SYNTAX INTEGER (10..20000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 20000 Default Value: 1500" DEFVAL { 1500 } ::= { cxMcVoxGlobal 101 } cxMcVoxGlobalGlmInBetwRespTime OBJECT-TYPE SYNTAX INTEGER (10..2000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 20000 Default Value: 500" DEFVAL { 500 } ::= { cxMcVoxGlobal 102 } cxMcVoxGlobalGlmMaxTimeToTxResp OBJECT-TYPE SYNTAX INTEGER (10..20000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 20000 Default Value: 1500" DEFVAL { 1500 } ::= { cxMcVoxGlobal 103 } cxMcVoxGlobalGlmVoiceSilenceTime OBJECT-TYPE SYNTAX INTEGER (100..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 100 to 60000 Default Value: 3000" DEFVAL { 3000 } ::= { cxMcVoxGlobal 104 } cxMcVoxGlobalGlmSupervSilenceTime OBJECT-TYPE SYNTAX INTEGER (1000..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 1000 to 60000 Default Value: 3000" DEFVAL { 3000 } ::= { cxMcVoxGlobal 105 } cxMcVoxGlobalGsdAutoCnctDelay OBJECT-TYPE SYNTAX INTEGER (1..20000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 1 to 20000 Default Value: 1" DEFVAL { 1 } ::= { cxMcVoxGlobal 106 } cxMcVoxGlobalClearLclExt OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS optional DESCRIPTION "Clears Local Extensions after the next Reset. Planned Local Extensions are cleared immediately. Options: no (1): Local Extensions are not cleared. yes (2): Local Extensions are cleared. Default Value: no (1) Configuration Change: administrative" DEFVAL { no } --#STARTING-VERSION 1 ::= { cxMcVoxGlobal 107 } cxMcVoxGlobalClearRmtExt OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS optional DESCRIPTION "Clears Remote Extensions after the next Reset. Planned Remote Extensions are cleared immediately. Options: no (1): Remote Extensions are not cleared. yes (2): Remote Extensions are cleared Default Value: no (1) Configuration Change: administrative" DEFVAL { no } --#STARTING-VERSION 1 ::= { cxMcVoxGlobal 108 } cxMcVoxGlobalWanSlot OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the slot number of the FR600 card that is performing Voice Routing with the new Voice Routing scheme. Range of Values: 1 to 16 Default Value: 1" DEFVAL { 1 } --#STARTING-VERSION 1 ::= { cxMcVoxGlobal 109 } cxMcVoxGlobalNetNbDigits OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the number of digits used to represent Local Extensions, Remote Extensions and Remote Extension group IDs. Range of Values: 1 to 4 Default Value: 3" DEFVAL { 3 } --#STARTING-VERSION 1 ::= { cxMcVoxGlobal 110 } cxMcVoxMibLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Used to determine current MIB module release supported by the agent. Object is in decimal." DEFVAL { 0 } --#STARTING-VERSION 1 ::= { cxMcVoxGlobal 111 } cxMcVoxGlobalRecogAcc OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This specifies whether to recognize the defined Access Code. With the option enabled, if the Access Code is recognized, it is stripped from the dialing digit flow and then the remaining digits are interpreted as the code that has been really dialed." DEFVAL { disabled } --#STARTING-VERSION 3 ::= { cxMcVoxGlobal 112 } cxMcVoxGlobalAccCode OBJECT-TYPE SYNTAX DisplayString (SIZE (1..5)) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the numeric code to access the international network. Range of Values: 1 to 5 numeric digits Default Value: 011 Configuration Changed: operational" DEFVAL { "011" } --#STARTING-VERSION 3 ::= { cxMcVoxGlobal 113 } cxMcVoxGlobalAccCodeLng OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Determines the number of digits in the configured Access Code." DEFVAL { 3 } --#STARTING-VERSION 3 ::= { cxMcVoxGlobal 114 } cxMcVoxGlobalAdmPinCodeLng OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Determines the administrative number of digits in all Personal Identification Numbers (PINs)." DEFVAL { 4 } --#STARTING-VERSION 4 ::= { cxMcVoxGlobal 115 } cxMcVoxGlobalOpePinCodeLng OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Determines the operational number of digits in all Personal Identification Numbers (PINs)." DEFVAL { 4 } --#STARTING-VERSION 4 ::= { cxMcVoxGlobal 116 } cxMcVoxGlobalClearHistoryTable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines whether to clear ALL logging information from the history table. Options: disable(1): No action enable(2): Clear history table completely" --#STARTING-VERSION 5 ::= { cxMcVoxGlobal 117 } cxMcVoxGlobalHistoryMaxNumberOfEntries OBJECT-TYPE SYNTAX INTEGER (20..256) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of entries in the history table." DEFVAL { 256 } --#STARTING-VERSION 5 ::= { cxMcVoxGlobal 118 } cxMcVoxGlobalHistoryPercentageFull OBJECT-TYPE SYNTAX INTEGER (0..95) ACCESS read-write STATUS mandatory DESCRIPTION "The percentage of the history table that must be filled before a trap is sent to the management station." DEFVAL { 70 } --#STARTING-VERSION 5 ::= { cxMcVoxGlobal 119 } cxMcVoxGlobalTrapHistory OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines if the call history trap is generated. The setting of this object is dynamic. When set to 'enable', the SNMP agent immediately begins to monitor the call history trap. Options: disable (1): No trap is generated. enable (2): Causes a trap message to be sent to the network management console each time a change occurs in the functional state (i.e., up or down) of the ring generator power supply. Default Value: disable (1) Configuration Changed: operative" DEFVAL { disable } --#STARTING-VERSION 5 ::= { cxMcVoxGlobal 120 } cxMcVoxGlobalLseTimerT2 OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65535 Default Value: 500" DEFVAL { 500 } --#STARTING-VERSION 9 ::= { cxMcVoxGlobal 121 } cxMcVoxGlobalLseTimerT3 OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65535 Default Value: 550" DEFVAL { 550 } --#STARTING-VERSION 9 ::= { cxMcVoxGlobal 122 } cxMcVoxGlobalExtBitMask OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object is a bitmap that selects up to cxMcVoxGlobalNetNbDigits, which can be set up to 4 digits, corresponding to a bit that is set. The default value corresponds to 7 (or 00000111 in binary). Range of Values: 0 to 255 Default Value: 7" DEFVAL { 7 } --#STARTING-VERSION 11 ::= { cxMcVoxGlobal 123 } -- =================================================================== -- cxMcVox CONFIGURATION GROUP cxMcVoxCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Voice station configuration Table." ::= { cxMcVox 2 } cxMcVoxCfgEntry OBJECT-TYPE SYNTAX CxMcVoxCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Voice station configuration row definition." INDEX { cxMcVoxCfgCardIndex, cxMcVoxCfgPortIndex } ::= { cxMcVoxCfgTable 1 } CxMcVoxCfgEntry ::= SEQUENCE { cxMcVoxCfgCardIndex INTEGER, cxMcVoxCfgPortIndex INTEGER, cxMcVoxCfgDriverAdmUsed INTEGER, cxMcVoxCfgDriverOpeUsed INTEGER, cxMcVoxCfgTrapOnLine INTEGER, cxMcVoxCfgTrapOffLine INTEGER, cxMcVoxCfgTrapStatus INTEGER, cxMcVoxCfgTrapState INTEGER, cxMcVoxCfgTestPort INTEGER, cxMcVoxCfgToneTest INTEGER, cxMcVoxCfgReinitPort INTEGER, cxMcVoxCfgClearPort INTEGER, cxMcVoxCfgOpeAcelpRev DisplayString, cxMcVoxCfgCmdImmTest INTEGER, cxMcVoxCfgCmdTest INTEGER, cxMcVoxCfgMaxPktFrame INTEGER, cxMcVoxCfgMaxSkew INTEGER } cxMcVoxCfgCardIndex OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default Value: none" ::= { cxMcVoxCfgEntry 1 } cxMcVoxCfgPortIndex OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the number of the voice port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card only has 1 port. CX1000: up to 15 for the DI600 Default Value: none" ::= { cxMcVoxCfgEntry 2 } cxMcVoxCfgDriverAdmUsed OBJECT-TYPE SYNTAX INTEGER { em(1), fxs(2), fxo(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the administrative driver of the port. The driver controls which signals the port supports. A port can only support one type of driver at any one time. Depending on the type of driver you choose, you must perform further configuration using one of the following tables: - cxMcVoxEmAdmtable (for E&M drivers) - cxMcVoxFxsAdmTable (for FXS drivers) - cxMcVoxFxoAdmTable (for FXO drivers) Options: em (1): Recommended for a PBX connection. Provides RJ-12 and PB-45 port connectors. fxs (2): Recommended for a standard telephone connection, where the Memotec device simulates a Telco. The device provides the ring and dial tone. FXS can also be used for a PBX connection, and provides an RJ-12 port connector. fxo (3): Recommended for a standard telephone connection, where the Memotec device simulates a telephone. FXO can also be used for a PBX connection, and provides an RJ-12 port connector. Default Value: fxs (2) Configuration Changed: administrative" DEFVAL { fxs } ::= { cxMcVoxCfgEntry 3 } cxMcVoxCfgDriverOpeUsed OBJECT-TYPE SYNTAX INTEGER { em(1), fxs(2), fxo(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the operative driver currently running on the port. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxCfgDriverAdmUsed (of this table). Options: em (1) fxs (2) fxo (3) Default Value: fxs (2)" ::= { cxMcVoxCfgEntry 4 } cxMcVoxCfgTrapOnLine OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS deprecated DESCRIPTION "Determines the state of the port's online trap. When set to 'enable', every time a fax or phone call begins (i.e. the port switches from online to offline), the SNMP agent generates a trap and sends it to the network management console. The setting of this object is dynamic. When set to'enable' the SNMP agent immediately begins to monitor the port. Options: disable (1) enable (2) Default Value: disable (1) Configuration Changed: operative" DEFVAL { disable } ::= { cxMcVoxCfgEntry 5 } cxMcVoxCfgTrapOffLine OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS deprecated DESCRIPTION "Determines the state of the port's offline trap. When set to 'enable', every time a fax or phone call ends ( i.e. the port switches from offline to online) the SNMP agent generates a trap and sends it to the network management console. The setting of this object is dynamic. When set to'enable' the SNMP agent immediately begins to monitor the port. Options: disable (1) enable (2) Default Value: disable (1) Configuration Changed: operative" DEFVAL { disable } ::= { cxMcVoxCfgEntry 6 } cxMcVoxCfgTrapStatus OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the state of the port's status trap. When set to 'enable', every time the functional state of the voice channel changes (i.e. up or down) the SNMP agent generates a trap and sends it to the network management console. The setting of this object is dynamic. When set to'enable' the SNMP agent immediately begins to monitor the voice channel. Options: disable (1) enable (2) Default Value: disable (1) Configuration Changed: operative" DEFVAL { disable } --#STARTING-VERSION 5 ::= { cxMcVoxCfgEntry 7 } cxMcVoxCfgTrapState OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS deprecated DESCRIPTION "Determines the state of the port's outgoing calls trap. When set to 'enable', every time an outgoing call request is in process the SNMP agent generates a trap and sends it to the network management console. The setting of this object is dynamic. When set to'enable' the SNMP agent immediately begins to monitor the port. Options: disable (1) enable (2) Default Value: disable (1) Configuration Changed: operative" DEFVAL { disable } ::= { cxMcVoxCfgEntry 8 } cxMcVoxCfgTestPort OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS optional DESCRIPTION "Determines the state of the port's self test. When set to 'yes', this object triggers the port to intiate a self-test. The port examines various hardware components, for example the RAM, DPRAM and I/O access. Each test runs for less than 2 seconds. You can perform the test on either an open (call in progress) or closed channel. If you perform the test on an open channel the call that is in progress is disconnected. The user must place the call again after the test is complete. Note: The port must be set to 'enable' (using the object cxMcVoxEmAdmPortStatus, cxMcVoxFxoAdmstatus or cxMcVoxFxsAdmStatus) to be able to perform the self-test. You can view the results of the test in the cxMcVoxStatusTable. While the port is running a self-test, it is not functional. It will return to normal when the test is complete. The setting of this object is dynamic. When set to'yes' the port immediately begins to monitor itself. Options: no (1) yes (2) Default Value: no (1) Configuration Changed: operative " DEFVAL { no } ::= { cxMcVoxCfgEntry 9 } cxMcVoxCfgToneTest OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the state of the port's standard tone test (1004Hz). When set to 'enable', this object triggers the port to perform a tone test. The port tests its voice sound quality by transmitting a 1004Hz tone. You can perform the test on either an open (call in progress) or closed channel. However, if you initiate the test on an open channel, the connection is not disrupted, but the local user will not be able to hear the remote user. The local user will only hear the tone the test generates. You must set this object to 'disable' to stop the test. It does not stop on its own. The setting of this object is dynamic. When set to'enable' the tone test begins immediately. Options: disable (1) enable (2) Default Value: disable (1) Configuration Changed: operative" DEFVAL { disable } ::= { cxMcVoxCfgEntry 10 } cxMcVoxCfgReinitPort OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS optional DESCRIPTION "Determines the port's reinitialization state. The setting of this object is dynamic. When set to 'yes', this object triggers the port to write all administrative port configuration entries to the operative port configuration table (i.e. they will be in the active port configuration). Options: no (1) yes (2) Default Value: no (1) Configuration Changed: administrative" DEFVAL { no } ::= { cxMcVoxCfgEntry 11 } cxMcVoxCfgClearPort OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS optional DESCRIPTION "Determines whether to restore all administrative voice port configurations to the default factory settings. The setting of this object is dynamic. When set to 'yes' the configuration of the administrative voice port (as displays in the objects cxMcVoxCfgCardIndex and cxMcVoxCfgPortIndex) will immediately change to the factory defaults. Options: no (1) yes (2) Default Value: no (1) Configuration Changed: administrative" DEFVAL { no } ::= { cxMcVoxCfgEntry 12 } cxMcVoxCfgOpeAcelpRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) ACCESS read-only STATUS optional DESCRIPTION "Displays the ACELP software revision currently running on the operative voice channel. Range of Values: 0 to 12 alphanumeric characters. You can use any combination of letters and numbers, however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: ACELP-2.BIN" ::= { cxMcVoxCfgEntry 14 } cxMcVoxCfgCmdImmTest OBJECT-TYPE SYNTAX INTEGER (0..4294967295) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 4294967295 Default Value: 0" ::= { cxMcVoxCfgEntry 15 } cxMcVoxCfgCmdTest OBJECT-TYPE SYNTAX INTEGER (0..4294967295) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 4294967295 Default Value: 0" ::= { cxMcVoxCfgEntry 16 } cxMcVoxCfgMaxPktFrame OBJECT-TYPE SYNTAX INTEGER (1..3) ACCESS read-write STATUS mandatory DESCRIPTION "The number of voice packet included in a voice frame. Less voice packet there is in a frame, bigger is the bandwitdh overhead on the WAN link, but better is the voice path end-to-end delay. The best compromise is a size of two (2) voice packets per voice frame, which correpsond to the default value." DEFVAL { 2 } --#STARTING-VERSION 5 ::= { cxMcVoxCfgEntry 17 } cxMcVoxCfgMaxSkew OBJECT-TYPE SYNTAX INTEGER (25..125) ACCESS read-write STATUS mandatory DESCRIPTION "The number of msec of skew that the end-to-end synchronization algorithm must compensate." DEFVAL { 50 } --#STARTING-VERSION 5 ::= { cxMcVoxCfgEntry 18 } -- =================================================================== -- cxMcVox STATISTICS & LOG HISTORY GROUP cxMcVoxStatAndLog OBJECT IDENTIFIER ::= { cxMcVox 3} -- cxMcVox STATUS GROUP TABLE cxMcVoxStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Voice station status table." ::= { cxMcVoxStatAndLog 1 } cxMcVoxStatusEntry OBJECT-TYPE SYNTAX CxMcVoxStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Voice station status row definition." INDEX { cxMcVoxStatusCardNumber, cxMcVoxStatusPortNumber } ::= { cxMcVoxStatusTable 1 } CxMcVoxStatusEntry ::= SEQUENCE { cxMcVoxStatusCardNumber INTEGER, cxMcVoxStatusPortNumber INTEGER, cxMcVoxStatusPortStatus INTEGER, cxMcVoxStatusHookLocal INTEGER, cxMcVoxStatusHookRem INTEGER, cxMcVoxStatusIoAccess INTEGER, cxMcVoxStatusChannelAccess INTEGER, cxMcVoxStatusDspRam INTEGER, cxMcVoxStatusDspDpram INTEGER, cxMcVoxStatusSamplingTime INTEGER, cxMcVoxStatusWatchdog INTEGER, cxMcVoxStatusRemPortStatus INTEGER, cxMcVoxStatusInputDbmLevel INTEGER, cxMcVoxStatusDspUtilization INTEGER, cxMcVoxStatusPhyIfType INTEGER, cxMcVoxStatusIOResetState INTEGER } cxMcVoxStatusCardNumber OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the slot number of the voice I/O card. You cannot modify this object. It is a display that the software provides. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default Value: none" ::= { cxMcVoxStatusEntry 1 } cxMcVoxStatusPortNumber OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the number of the voice I/O port. You cannot modify this object. It is a display that the software provides. Options: CX900: 1 is the only acceptable value. Each I/O card only has 1 port. CX1000: up to 15 for the DI600 Default Value: none" ::= { cxMcVoxStatusEntry 2 } cxMcVoxStatusPortStatus OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), no-voice-io (3), boot-err-1 (31), boot-err-2 (32), boot-err-3 (33), boot-err-4 (34), appl-err-1 (41), appl-err-2 (42), appl-err-3 (43), appl-err-4 (44) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the functional status of the port. You cannot modify this object. It is a display that the software provides. Options: disable (1): port is not functional enable (2): port is up and active no-voice-io (3): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-1 (31): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-2 (32): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-3 (33): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-4 (34): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-1 (41): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-2 (42): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-3 (43): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-4 (44): Memotec use only. Contact Memotec service personnel if this value displays. Default Value: none" ::= { cxMcVoxStatusEntry 3 } cxMcVoxStatusHookLocal OBJECT-TYPE SYNTAX INTEGER { on (1), off (2), unknown (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the state of the local port's ability to establish a connection. When the status shows 'on', the port is idle and ready to transmit. You cannot modify this object. It is a display that the software provides. Options: on (1): port is in the on-hook state and is able to establish a connection. off (2): port is in the off-hook state and cannot establish a connection. " ::= { cxMcVoxStatusEntry 4 } cxMcVoxStatusHookRem OBJECT-TYPE SYNTAX INTEGER { on (1), off (2), unknown (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the state of the remote port's ability to establish a connection. When the status shows 'on', the remote port is idle and ready to transmit. You cannot modify this object. It is a display that the software provides. Options: on (1): port is in the on-hook state and is able to establish a connection. off (2): port is in the off-hook state and cannot establish a connection. unknown (3) " ::= { cxMcVoxStatusEntry 5 } cxMcVoxStatusIoAccess OBJECT-TYPE SYNTAX INTEGER { fault (1), passed (2), inapplicable (3), running (4) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the results of the test that the CPU performs on the accessibility of the voice channel control registers residing on the voice I/O card. This object displays results from the self-test which you initiate using the object cxMcVoxCfgtestPort (of the cxMcVox Configuration Group table). You cannot modify this object. Options: fault (1): CPU cannot access the voice channel registers on the voice I/O card. Contact Memotec service personnel. passed (2): CPU is able to access the voice channel registers on the voice I/O card. inapplicable (3): self-test has not been run since last system reset. running (4): self-test is currently running. Results are not yet available. Default Value: none" ::= { cxMcVoxStatusEntry 6 } cxMcVoxStatusChannelAccess OBJECT-TYPE SYNTAX INTEGER { fault (1), passed (2), inapplicable (3), running (4) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the results of the test the CPU performs on the DPRAM. This object displays results from the self-test which you initiate using the object cxMcVoxCfgtestPort (of the cxMcVox Configuration Group table). You cannot modify this object. Options: fault (1): CPU cannot access the DPRAM. Contact Memotec service personnel. passed (2): CPU is able to access DPRAM. inapplicable (3): self-test has not been run since last system reset. running (4): self-test is currently running. Results are not yet available. Default Value: none" ::= { cxMcVoxStatusEntry 7 } cxMcVoxStatusDspRam OBJECT-TYPE SYNTAX INTEGER { fault (1), passed (2), inapplicable (3), running (4) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the results of the test the DSP performs on the accessibility of the RAM memory on the voice I/O card. This object displays results from the self-test which you initiate using the object cxMcVoxCfgtestPort (of the cxMcVox Configuration Group table). You cannot modify this object. Options: fault (1): DSP cannot access the RAM memory on the voice I/O card. Contact Memotec service personnel. passed (2): DSP is able to access RAM memory. inapplicable (3): self-test has not been run since last system reset. running (4): self-test is currently running. Results are not yet available. Default Value: none" ::= { cxMcVoxStatusEntry 8 } cxMcVoxStatusDspDpram OBJECT-TYPE SYNTAX INTEGER { fault (1), passed (2), inapplicable (3), running (4) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the results of the test the DSP performs on the voice I/O card's DPRAM memory. This object displays results from the self-test which you initiate using the object cxMcVoxCfgtestPort (of the cxMcVox Configuration Group table). You cannot modify this object. Options: fault (1): DSP cannot access the DPRAM memory on the voice I/O card. Contact Memotec service personnel. passed (2): DSP is able to access DPRAM memory on the voice I/O card. inapplicable (3): self-test has not been run since last system reset. running (4): self-test is currently running. Results are not yet available. Default Value: none" ::= { cxMcVoxStatusEntry 9 } cxMcVoxStatusSamplingTime OBJECT-TYPE SYNTAX INTEGER { fault (1), passed (2), inapplicable (3), running (4) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the results of the test the DSP performs on the sampling rate of a voice stream. The DSP tests that the sampling rate is done at 8KHz. This object displays results from the self-test which you initiate using the object cxMcVoxCfgtestPort (of the cxMcVox Configuration Group table). You cannot modify this object. Options: fault (1): DSP cannot test sampling rate. Contact Memotec service personnel. passed (2): DSP is able to test sampling rate and it is at 8KHz. inapplicable (3): self-test has not been run since last system reset. running (4): self-test is currently running. Results are not yet available. Default Value: none" ::= { cxMcVoxStatusEntry 10 } cxMcVoxStatusWatchdog OBJECT-TYPE SYNTAX INTEGER { fault (1), passed (2), inapplicable (3), running (4) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the results of the test the CPU performs on the watchdog timer which resides on the voice I/O card. This object displays results from the self-test which you initiate using the object cxMcVoxCfgtestPort (of the cxMcVox Configuration Group table). You cannot modify this object. Options: fault (1): CPU cannot access the watchdog timer. Contact Memotec service personnel. passed (2): CPU is able to access watchdog timer and it is performing properly. inapplicable (3): self-test has not been run since last system reset. running (4): self-test is currently running. Results are not yet available. Default Value: none" ::= { cxMcVoxStatusEntry 11 } cxMcVoxStatusRemPortStatus OBJECT-TYPE SYNTAX INTEGER (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the channel number of the attached remote port. You cannot modify this object. Range of Values: 0-4294967295" ::= { cxMcVoxStatusEntry 12 } cxMcVoxStatusInputDbmLevel OBJECT-TYPE SYNTAX INTEGER (700..1050) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the current Dbm level of the input analog voice signal. You cannot modify this object. . Range of Values: 700 to 1050 (-30dBm to 5dBm) Default Value: none" ::= { cxMcVoxStatusEntry 13 } cxMcVoxStatusPhyIfType OBJECT-TYPE SYNTAX INTEGER { if-em (1), if-fxs (2), if-fxo (3), if-absent (4), if-unknown (5) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cxMcVoxStatusEntry 14 } -- ADVANCED MODE OBJECTS: (start at index 100) cxMcVoxStatusDspUtilization OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-only STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 1000 Default Value: none" ::= { cxMcVoxStatusEntry 100 } cxMcVoxStatusIOResetState OBJECT-TYPE SYNTAX INTEGER { in-reset (1), normal (2), unknown (3) } ACCESS read-only STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Options: in-reset (1) normal (2) unknown (3)" ::= { cxMcVoxStatusEntry 101 } -- ................................................................... -- cxMcVox EVENTS GROUP TABLE cxMcVoxEventTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxEventEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "OnLine/OffLine events table for incoming/outgoing calls." --#ENDING-VERSION 5 ::= { cxMcVoxStatAndLog 2 } cxMcVoxEventEntry OBJECT-TYPE SYNTAX CxMcVoxEventEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Online/Offline events row definition." INDEX { cxMcVoxEventCardNumber, cxMcVoxEventPortNumber, cxMcVoxEventLogIndex } ::= { cxMcVoxEventTable 1 } CxMcVoxEventEntry ::= SEQUENCE { cxMcVoxEventCardNumber INTEGER, cxMcVoxEventPortNumber INTEGER, cxMcVoxEventLogIndex INTEGER, cxMcVoxEventDateAndTimeOnLine DisplayString, cxMcVoxEventDateAndTimeOffLine DisplayString, cxMcVoxEventPhoneNumber DisplayString, cxMcVoxEventLnkState INTEGER, cxMcVoxEventPin DisplayString, cxMcVoxEventClrEvts INTEGER } cxMcVoxEventCardNumber OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 4 Default Value: none" ::= { cxMcVoxEventEntry 1 } cxMcVoxEventPortNumber OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the number of the voice I/O port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card only has 1 port. CX1000: 1 or 2 Default Value: none" ::= { cxMcVoxEventEntry 2 } cxMcVoxEventLogIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the index number of the event log. You cannot modify this object. Range of Values: 1 to 4294967295 Default Value: none" ::= { cxMcVoxEventEntry 3 } cxMcVoxEventDateAndTimeOnLine OBJECT-TYPE SYNTAX DisplayString (SIZE (20..20)) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the date and time of the last online event. An online event is any incoming or outgoing call that the voice station generates. The format of the display is as follows: Year/Month/Date-Day-Hours:Minutes:Seconds You cannot modify this object. Range of Values: Year: 0-99 Month: 1-12 Date: 1-31 (day of the month) Day : 0-6 (day of the week - 0 being Sunday) Hours: 0-23 Minutes: 0-59 Seconds: 0-59 Default Value: none" ::= { cxMcVoxEventEntry 4 } cxMcVoxEventDateAndTimeOffLine OBJECT-TYPE SYNTAX DisplayString (SIZE (20..20)) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the date and time of the last offline event. An offline event is any incoming or outgoing call that the voice station terminates. The format of the display is as follows: Year/Month/Date-Day-Hours:Minutes:Seconds You cannot modify this object. Range of Values: Year: 0-99 Month: 1-12 Date: 1-31 (day of the month) Day : 0-6 (day of the week - 0 being Sunday) Hours: 0-23 Minutes: 0-59 Seconds: 0-59 Default Value: none" ::= { cxMcVoxEventEntry 5 } cxMcVoxEventPhoneNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (1..32)) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the phone number (including any voice mail digits) the user enters to reach a remote telephone or fax machine. This object is irrelevant for incoming calls. You cannot modify this object. Range of Values: 1 to 32 numeric digits Default Value: none" ::= { cxMcVoxEventEntry 6 } cxMcVoxEventLnkState OBJECT-TYPE SYNTAX INTEGER { remUnavailable (1), remError (2), busy (3), open (4), errActiveChn (5), errPath (6), errLnk (7), fixedLnkDown (8), fixedLnkUp (9) } ACCESS read-only STATUS deprecated DESCRIPTION "Displays the status of the link to the remote telephone or fax machine. You cannot modify this object. Options: remUnavailable (1): the routing specifies a remote chassis location that does not exist. remError (2): all voice ports at the specified remote are inactive and therefore cannot accept the call. It is possible that the remote ports are disabled or that the I/O card is not installed. busy (3): all voice ports at the specified remote are busy and therefore unavailable to accept the call. open (4): the call was successfully put through to a voice port at the remote location. errActiveChn (5): the end-user has replaced the receiver (on-hook) at the end of a call and then removed the receiver (off-hook) so quickly that the connection has not had sufficient time to completely disconnect. The end-user should wait a few seconds after replacing the receiver before attempting to place another call. errPath (6): the Path ID (dialing code) the user entered is not listed in the routing table. Check that the Path ID and routing are completely configured. errLnk (7): there is an error condition on the line between the local and remote link stations causing the link to be inactive. fixedLnkDown (8): Memotec use only. Contact Memotec service personnel if this value displays. fixedLnkUp (9): Memotec use only. Contact Memotec service personnel if this value displays. Default Value: none" ::= { cxMcVoxEventEntry 7 } cxMcVoxEventPin OBJECT-TYPE SYNTAX DisplayString (SIZE (2..8)) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the Personal Identification Number (PIN) that is validated against the local voice station card PIN number table. Range of Values: 2 to 8 numeric digits, each number from 0 to 9 Default Value: none" --#STARTING-VERSION 4 ::= { cxMcVoxEventEntry 8 } cxMcVoxEventClrEvts OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS deprecated DESCRIPTION "Determines whether to clear ALL logging information from the Event group table. Options: no (1) yes (2) Default Value: no (1) Configuration Change: none" DEFVAL { no } --#STARTING-VERSION 1 ::= { cxMcVoxEventEntry 9 } -- ................................................................... -- cxMcVox STATE GROUP TABLE cxMcVoxStateTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxStateEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Connections table for outgoing calls." --#ENDING-VERSION 5 ::= { cxMcVoxStatAndLog 3 } cxMcVoxStateEntry OBJECT-TYPE SYNTAX CxMcVoxStateEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Outgoing call connection state row definition." INDEX { cxMcVoxStateCardNumber, cxMcVoxStatePortNumber, cxMcVoxStateLogIndex } ::= { cxMcVoxStateTable 1 } CxMcVoxStateEntry ::= SEQUENCE { cxMcVoxStateCardNumber INTEGER, cxMcVoxStatePortNumber INTEGER, cxMcVoxStateLogIndex INTEGER, cxMcVoxStatePathId DisplayString, cxMcVoxStateDateAndTime DisplayString, cxMcVoxStateLnkState INTEGER, cxMcVoxStateRmtExt DisplayString } cxMcVoxStateCardNumber OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the slot number of the voice I/O card. You cannot modify this object. It is a display that the software provides. Range of Values: CX900: 1 to 6 CX1000: 1 to 4 Default Value: none" ::= { cxMcVoxStateEntry 1 } cxMcVoxStatePortNumber OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the number of the voice I/O port. You cannot modify this object. It is a display that the software provides. Options: CX900: 1 is the only acceptable value. Each I/O card on has 1 port. CX1000: 1 or 2 Default Value: none" ::= { cxMcVoxStateEntry 2 } cxMcVoxStateLogIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the number of the table row containing objects used for monitoring the path state. You cannot modify this object. Range of Values: 1 to 4294967295 Default Value: none" ::= { cxMcVoxStateEntry 3 } cxMcVoxStatePathId OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the Path ID or Group ID that the user dials to access the remote telephone or fax machine. Displays the Path ID or Group ID that the user dials to access the remote telephone or fax machine. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxPathAdmPathId of the cxMcVox Administrative Path Group. Range of Values: 1 to 4 numeric digits Default Value: none" --#ENDING-VERSION 1 ::= { cxMcVoxStateEntry 4 } cxMcVoxStateDateAndTime OBJECT-TYPE SYNTAX DisplayString (SIZE (20..20)) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the date and time the link associated with the Path/Group ID changed state (i.e. the call was initiated). The format of the display is as follows: Year/Month/Date-Day-Hours:Minutes:Seconds You cannot modify this object. Range of Values: Year: 0-99 Month: 1-12 Date: 1-31 (day of the month) Day : 0-6 (day of the week, 0 being Sunday) Hours: 0-23 Minutes: 0-59 Seconds: 0-59 Default Value: none" ::= { cxMcVoxStateEntry 5 } cxMcVoxStateLnkState OBJECT-TYPE SYNTAX INTEGER { remUnavailable (1), remError (2), busy (3), open (4), errActiveChn (5), errPath (6), errLnk (7), fixedLnkDown (8), fixedLnkUp (9) } ACCESS read-only STATUS deprecated DESCRIPTION "Displays the status of the link to the remote telephone or fax machine. You cannot modify this object. Options: remUnavailable (1): the routing specifies a remote chassis location that does not exist. remError (2): all voice ports at the specified remote are inactive and therefore cannot accept the call. It is possible that the remote ports are disabled or that the I/O card is not installed. busy (3): all voice ports at the specified remote are busy and therefore unavailable to accept the call. open (4): the call was successfully put through to a voice port at the remote location. errActiveChn (5): the end-user has replaced the receiver (on-hook) at the end of a call and then removed the receiver (off-hook) so quickly that the connection has not had sufficient time to completely disconnect. The end-user should wait a few seconds after replacing the receiver before attempting to place another call. errPath (6): the Path ID (dialing code) the user entered is not listed in the routing table. Check that the Path ID and routing are completely configured. errLnk (7): there is an error condition on the line between the local and remote link stations causing the link to be inactive. fixedLnkDown (8): Memotec use only. Contact Memotec sevice personnel if this value displays. fixedLnkUp (9): Memotec use only. Contact Memotec service personnel if this value displays. Default Value: none" ::= { cxMcVoxStateEntry 6 } cxMcVoxStateRmtExt OBJECT-TYPE SYNTAX DisplayString (SIZE (1..5)) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the Remote Extension or Group ID that the user dials to access the remote telephone or fax machine. You cannot modify this object. Range of Values: 1 to 5 numeric digits Default Value: none" --#STARTING-VERSION 1 ::= { cxMcVoxStateEntry 7 } -- ====================================================================== -- cxMcVox ADMINISTRATIVE PATH GROUP -- note: The path ID table must be defined after the net ID table. cxMcVoxPathAdmTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxPathAdmEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Planned pathID table." --#ENDING-VERSION 1 ::= { cxMcVox 4 } cxMcVoxPathAdmEntry OBJECT-TYPE SYNTAX CxMcVoxPathAdmEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Planned pathID row definition." INDEX { cxMcVoxPathAdmIndex } ::= { cxMcVoxPathAdmTable 1 } CxMcVoxPathAdmEntry ::= SEQUENCE { cxMcVoxPathAdmIndex INTEGER, cxMcVoxPathAdmRowStatus INTEGER, cxMcVoxPathAdmPathId DisplayString, cxMcVoxPathAdmRemStationId DisplayString, cxMcVoxPathAdmHunt INTEGER, cxMcVoxPathAdmLng INTEGER } cxMcVoxPathAdmIndex OBJECT-TYPE SYNTAX INTEGER (1..300) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the index number of the Path ID. You cannot modify this object. Range of Values: 1 to 300 Default Value: none" ::= { cxMcVoxPathAdmEntry 1 } cxMcVoxPathAdmRowStatus OBJECT-TYPE SYNTAX INTEGER { invalid (1), valid (2) } ACCESS read-write STATUS deprecated DESCRIPTION "Determines the status of the objects in a table row. Options: invalid (1): Row is deleted from the table immediately, however values are still in effect until the next reset. valid (2): Use this value to add a new row to the table, or modify an existing row. Default Value: none Configuration Changed: administrative" ::= { cxMcVoxPathAdmEntry 2 } cxMcVoxPathAdmPathId OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS deprecated DESCRIPTION "Determines the administrative numeric dialing code that the user enters to access the remote telephone or fax machine. Note: The length of the ID must match the value you define for the object cxMcVoxPathAdmPathLng (of this table). Range of Values: 1 to 4 numeric digits Default Value: none Configuration Changed: administrative" ::= { cxMcVoxPathAdmEntry 3 } cxMcVoxPathAdmRemStationId OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) ACCESS read-write STATUS deprecated DESCRIPTION "Determines the administrative ID (name) of the remote voice station. Note: The remote voice station must exist in the Network Routing table before its ID can be defined. Range of Values: a maximum of 12 alphanumeric characters. All characters must be in capital letters. You can use any combination of letters and numbers, however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none Configuration Changed: administrative" ::= { cxMcVoxPathAdmEntry 4 } cxMcVoxPathAdmHunt OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-write STATUS deprecated DESCRIPTION "Determines the port numbers included in the administrative Hunt Group. A Hunt Group identifies multiple ports on a single remote voice station (as defined with the object cxMcVoxPathAdmRemStationId of this table). The Path ID (defined using the object cxMcVoxPathAdmId of this table) references this Hunt Group during call establishment. Each port in the Hunt Group is polled until one of the ports accepts the call. A maximum of 32 ports can be in a single hunt group. Range of Values: 1 to 4294967295 Default Value: 65535 Configuration Changed: administrative" DEFVAL { 65535 } ::= { cxMcVoxPathAdmEntry 5 } cxMcVoxPathAdmLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-write STATUS deprecated DESCRIPTION "Determines the length (in digits) of the administrative Path ID. Note: If you modify the current operative value to one that is a lower digit, the current operative Path IDs (using the higher value) will be lost once the administrative setting is initialized. Range of Values: 1 to 4 Default Value: 3 Configuration Changed: administrative" DEFVAL { 3 } ::= { cxMcVoxPathAdmEntry 6 } -- ================================================================== -- cxMcVox OPERATIONAL PATH GROUP cxMcVoxPathOpeTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxPathOpeEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Active pathID table." --#ENDING-VERSION 1 ::= { cxMcVox 5 } cxMcVoxPathOpeEntry OBJECT-TYPE SYNTAX CxMcVoxPathOpeEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Active pathID row definition." INDEX { cxMcVoxPathOpeIndex } ::= { cxMcVoxPathOpeTable 1 } CxMcVoxPathOpeEntry ::= SEQUENCE { cxMcVoxPathOpeIndex INTEGER, cxMcVoxPathOpePathId DisplayString, cxMcVoxPathOpeRemStationId DisplayString, cxMcVoxPathOpeHunt INTEGER, cxMcVoxPathOpeLng INTEGER } cxMcVoxPathOpeIndex OBJECT-TYPE SYNTAX INTEGER (1..300) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the index number of the operational Path ID. You cannot modify this object. Range of Values: 1 to 300 Default Value: none" ::= { cxMcVoxPathOpeEntry 1 } cxMcVoxPathOpePathId OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the operational Path ID. The Path ID is the numeric dialing code the user enters to gain access to the remote telephone or fax machine. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxPathAdmPathId of the cxMcVox Administrative Configuration Group. Range of Values: 1 to 4 digits Default Value: none " ::= { cxMcVoxPathOpeEntry 2 } cxMcVoxPathOpeRemStationId OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) ACCESS read-only STATUS deprecated DESCRIPTION " Displays the operational ID (name) of the remote voice station. Note: The remote voice station must exist in the Network Routing table before its ID can be defined. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxNetAdmRemStationId of the cxMcVox Administrative Net group Range of Values: a maximum of 12 alphanumeric characters. All characters must be in capital letters. You can use any combination of letters and numbers, however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default: none" ::= { cxMcVoxPathOpeEntry 3 } cxMcVoxPathOpeHunt OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the port numbers included in the operational Hunt Group. A Hunt Group identifies multiple ports on a single remote voice station (as defined with the object cxMcVoxPathAdmRemStationId of this table). The Path ID (defined using the object cxMcVoxPathAdmId of this table) references this hunt group during call establishment. Each port in the Hunt Group is polled until one of the ports accepts the call. A maximum of 8 ports can be in a single hunt group. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxPathAdmHunt of the cxMcVox Administrative Path Group. Range of Values: 1 to 4294967295 Default Value: 65535" DEFVAL { 65535 } ::= { cxMcVoxPathOpeEntry 4 } cxMcVoxPathOpeLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the length (in digits) of the operative Path ID. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxPathAdmPathLng of the cxMcVox Administrative Path Group. Range of Values: 1 to 4 Default Value: 3" DEFVAL { 3 } ::= { cxMcVoxPathOpeEntry 5 } -- ==================================================================== -- cxMcVox ADMINISTRATIVE NET GROUP cxMcVoxNetAdmTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxNetAdmEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Planned NET entries." --#ENDING-VERSION 1 ::= { cxMcVox 6 } cxMcVoxNetAdmEntry OBJECT-TYPE SYNTAX CxMcVoxNetAdmEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Planned NET row." INDEX { cxMcVoxNetAdmIndex } ::= { cxMcVoxNetAdmTable 1 } CxMcVoxNetAdmEntry ::= SEQUENCE { cxMcVoxNetAdmIndex INTEGER, cxMcVoxNetAdmRowStatus INTEGER, cxMcVoxNetAdmRemStationId DisplayString, cxMcVoxNetAdmLocalLnkStation INTEGER, cxMcVoxNetAdmRoute INTEGER, cxMcVoxNetAdmRemVoxStation INTEGER } cxMcVoxNetAdmIndex OBJECT-TYPE SYNTAX INTEGER (1..300) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the index number of the administrative network routing entry. You cannot modify this object. Range of Values: 1 to 300 Default Value: none" ::= { cxMcVoxNetAdmEntry 1 } cxMcVoxNetAdmRowStatus OBJECT-TYPE SYNTAX INTEGER { invalid (1), valid (2) } ACCESS read-write STATUS deprecated DESCRIPTION "Determines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values will be disabled and the row will be deleted from the table. valid (2): values are enabled Default Value: none Configuration Changed: administrative" ::= { cxMcVoxNetAdmEntry 2 } cxMcVoxNetAdmRemStationId OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) ACCESS read-write STATUS deprecated DESCRIPTION "Determines the administrative ID (name) of the remote voice station. Range of Values: a maximum of 12 alphanumeric characters. All characters must be in capital letters. You can use any combination of letters and numbers, however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default: none Configuration Changed: administrative" ::= { cxMcVoxNetAdmEntry 3 } cxMcVoxNetAdmLocalLnkStation OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-write STATUS deprecated DESCRIPTION "Determines the slot number holding the local CPU board supporting the GMF software. This value is always '1' if the CPU is in the CX900 architecture. Range of Values: CX900: 1 CX1000: 1 to 16 Default Value: 1 Configuration Changed: administrative" DEFVAL { 1 } ::= { cxMcVoxNetAdmEntry 4 } cxMcVoxNetAdmRoute OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-write STATUS deprecated DESCRIPTION "Determines the number that identifies the administrative link entry in the GMF (Gateway Mux Frame Relay). The network administrator assigns this number in sequential order starting at 1. You then must establish an internal system route from the GMF route number to a Frame Relay circuit alias using the objects gmfSRLink and gmfSRDestCircuitAlias of the GMF System Routing Definition Group. Range of Values: 1 to 1024 Default Value: 1 Configuration Changed: administrative" DEFVAL { 1 } ::= { cxMcVoxNetAdmEntry 5 } cxMcVoxNetAdmRemVoxStation OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-write STATUS deprecated DESCRIPTION "Determines the slot number holding the remote CPU board that supports the voice software. This value is always '1' if the remote CPU is in the CX900 architecture. Range of Values: CX900: 1 CX1000: 1 to 16 Default Value: 1 Configuration Changed: administrative" DEFVAL { 1 } ::= { cxMcVoxNetAdmEntry 6 } -- ==================================================================== -- cxMcVox OPERATIONAL NET GROUP cxMcVoxNetOpeTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxNetOpeEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Active net entries table." --#ENDING-VERSION 1 ::= { cxMcVox 7 } cxMcVoxNetOpeEntry OBJECT-TYPE SYNTAX CxMcVoxNetOpeEntry ACCESS not-accessible STATUS deprecated DESCRIPTION "Active net entry row definition." INDEX { cxMcVoxNetOpeIndex } ::= { cxMcVoxNetOpeTable 1 } CxMcVoxNetOpeEntry ::= SEQUENCE { cxMcVoxNetOpeIndex INTEGER, cxMcVoxNetOpeRemStationId DisplayString, cxMcVoxNetOpeLocalLnkStation INTEGER, cxMcVoxNetOpeRoute INTEGER, cxMcVoxNetOpeRemVoxStation INTEGER } cxMcVoxNetOpeIndex OBJECT-TYPE SYNTAX INTEGER (1..300) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the index number of the operative network routing entry. You cannot modify this object Range of Values: 1 to 300 Default Value: none" ::= { cxMcVoxNetOpeEntry 1 } cxMcVoxNetOpeRemStationId OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the operative ID (name) of the remote voice station. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxNetAdmOpeRemStationId of the cxMcVox Administrative Net Group. Range of Values: a maximum of 12 alphanumeric characters. All characters must be in capital letters. You can use any combination of letters and numbers, however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default: none" ::= { cxMcVoxNetOpeEntry 2 } cxMcVoxNetOpeLocalLnkStation OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the slot number holding the local CPU board supporting the GMF software. This value is always '1' if the CPU is in the CX900 architecture. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxNetAdmOpeLocalLnkStation of the cxMcVox Administrative Net Group. Range of Values: CX900: 1 CX1000: 1 to 16 Default Value: 1" DEFVAL { 1 } ::= { cxMcVoxNetOpeEntry 3 } cxMcVoxNetOpeRoute OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the number that identifies the operative link entry. The network administrator assigns this number to identify the route in the routing table. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxNetAdmOpeRoute of the cxMcVox Administrative Net Group. Range of Values: 1 to 1024 Default Value: 1" DEFVAL { 1 } ::= { cxMcVoxNetOpeEntry 4 } cxMcVoxNetOpeRemVoxStation OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the slot number holding the remote CPU board that supports the voice software. This value is always '1' if the remote CPU is in the CX900 architecture. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxNetAdmRemVoxStation of the cxMcVox Administrative Net Group. Range of Values: CX900: 1 CX1000: 1 to 16 Default Value: 1" DEFVAL { 1 } ::= { cxMcVoxNetOpeEntry 5 } -- ===================================================================== -- cxMcVox DRIVERS -- cxMcVox ADMINISTRATIVE DRIVER GROUP cxMcVoxDriverAdm OBJECT IDENTIFIER ::= {cxMcVox 8 } -- cxMcVox ADMINISTRATIVE E&M DRIVER GROUP cxMcVoxEmAdmTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxEmAdmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Voice station planned E&M Table." ::= { cxMcVoxDriverAdm 1 } cxMcVoxEmAdmEntry OBJECT-TYPE SYNTAX CxMcVoxEmAdmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Voice station planned E&M row definition." INDEX { cxMcVoxEmAdmCardUsed, cxMcVoxEmAdmPortUsed } ::= { cxMcVoxEmAdmTable 1 } CxMcVoxEmAdmEntry ::= SEQUENCE { cxMcVoxEmAdmCardUsed INTEGER, cxMcVoxEmAdmPortUsed INTEGER, cxMcVoxEmAdmPortStatus INTEGER, cxMcVoxEmAdmVocoder INTEGER, cxMcVoxEmAdmFaxBw INTEGER, cxMcVoxEmAdmAutoCnx INTEGER, cxMcVoxEmAdmPathId DisplayString, cxMcVoxEmAdmTxGain INTEGER, cxMcVoxEmAdmRxGain INTEGER, cxMcVoxEmAdmEchoCancel INTEGER, cxMcVoxEmAdmType INTEGER, cxMcVoxEmAdmMode INTEGER, cxMcVoxEmAdmDialType INTEGER, cxMcVoxEmAdmSignalType INTEGER, cxMcVoxEmAdmAc15Type INTEGER, cxMcVoxEmAdmAc15TimeOn INTEGER, cxMcVoxEmAdmAc15TimeOff INTEGER, cxMcVoxEmAdmCnctType INTEGER, cxMcVoxEmAdmRingType INTEGER, cxMcVoxEmAdmRmtExt DisplayString, cxMcVoxEmAdmRmtId DisplayString, cxMcVoxEmAdmTranspMode INTEGER, cxMcVoxEmAdmFaxEnable INTEGER, cxMcVoxEmAdmBroadcast INTEGER, cxMcVoxEmAdmImpedance INTEGER, cxMcVoxEmAdmVoiceConnection INTEGER } -- USER MODE OBJECTS: cxMcVoxEmAdmCardUsed OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default: none" ::= { cxMcVoxEmAdmEntry 1 } cxMcVoxEmAdmPortUsed OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the number of the voice port. You cannot modify this object. It is a display that the software provides. Options: CX900: 1 is the only acceptable value. Each I/O card only has 1 port. CX1000: up to 15 for the DI600 Default Value: none" ::= { cxMcVoxEmAdmEntry 2 } cxMcVoxEmAdmPortStatus OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the functional status of the administrative E&M port. Options: disable (1): port is not functional enable (2): port is up and active Default Value: disable (1) Configuration Changed: administrative" DEFVAL { disable } ::= { cxMcVoxEmAdmEntry 3 } cxMcVoxEmAdmVocoder OBJECT-TYPE SYNTAX INTEGER { bps5800 (1), bps8000 (2), kbps40 (3), kbps32 (4), kbps24 (5), kbps16 (6), opt7 (7), opt8 (8) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the transmission speed (in bits per second) of the compressed voice stream on the administrative E&M port. Defining the speed also sets the ACELP voice compression ratio. Options: bps5800 (1): compresses at a higher rate and uses slightly less bandwidth. bps8000 (2): compresses at approximately an 8:1 ratio (lower rate) with a higher quality voice sound at the receiving end. opt3 (3): ADPCM 40. opt4 (4): ADPCM 32. opt5 (5): ADPCM 24. opt6 (6): ADPCM 16. opt7 (7): Memotec use only. opt8 (8): Memotec use only. Default Value: bps8000 Configuration Changed: administrative" DEFVAL { bps8000 } ::= { cxMcVoxEmAdmEntry 4 } cxMcVoxEmAdmFaxBw OBJECT-TYPE SYNTAX INTEGER { bps2400 (1), bps4800 (2), bps7200 (3), bps9600 (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the speed (in bits per second) of the FAX channel on the administrative E&M port. This value also determines the bandwidth required to pass FAX traffic through the voice software. This value can be set to match the speed of your FAX machine or it can be lowered to reduce bandwidth allocation. Options: bps2400 (1) bps4800 (2) bps7200 (3) bps9600 (4) Default Value: bps7200 (3) Configuration Changed: administrative" DEFVAL { bps7200 } ::= { cxMcVoxEmAdmEntry 5 } -- obsolete object (has been redefined) cxMcVoxEmAdmAutoCnx OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS obsolete DESCRIPTION "Obsolete." DEFVAL { no } ::= { cxMcVoxEmAdmEntry 6 } cxMcVoxEmAdmPathId OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS deprecated DESCRIPTION "Path IDs no longer exist in the new Voice Routing (VR) scheme. Determines the Path ID used for auto-connection on the administrative E&M port. The Path ID is a numeric dialing code the user enters to gain access to the remote telephone or fax machine. Note: The number of digits in the Path ID must match the value of the object cxMcVoxPathAdmPathLng of the cxMcVox Administrative Path Group. Range of Values: 1 to 4 numeric digits Default Value: none Configuration Changed: administrative" --#ENDING-VERSION 1 DEFVAL { "000" } ::= { cxMcVoxEmAdmEntry 7 } cxMcVoxEmAdmTxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the value defining the sound intensity (loudness) of voice transmissions on the administrative E&M port. The transmission gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Transmission gains should be modified during a connection (i.e. dynamically) as changes in the value affect the local listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: administrative" DEFVAL { 960 } ::= { cxMcVoxEmAdmEntry 8 } cxMcVoxEmAdmRxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the value defining the sound intensity (loudness) of voice reception on the administrative E&M port. The reception gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Reception gains should be modified during a connection (i.e. dynamically) as changes in the value affect the remote listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: administrative" DEFVAL { 960 } ::= { cxMcVoxEmAdmEntry 9 } cxMcVoxEmAdmEchoCancel OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the state of echo cancellation on the administrative E&M port. When set to 'enable', at both the local and remote ends, echo cancellation stops echoes from the remote that are heard through the receiver at the local end. Options: disable (1) enable (2) Default Value: enable (2) Configuration Changed: administrative" DEFVAL { enable } ::= { cxMcVoxEmAdmEntry 10 } cxMcVoxEmAdmType OBJECT-TYPE SYNTAX INTEGER { type-1 (1), type-2 (2), type-3 (3), type-4 (4), type-5 (5) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the type of E&M interface on the administrative E&M port. Each of the five interface types has a unique signal-to-wire pattern. Make sure that you select the interface type that matches your PBX. Options: type-1 (1) type-2 (2) type-3 (3) type-4 (4) type-5 (5) Default Value: type-2 (2) Configuration Changed: administrative NOTE: This object is READ-ONLY for the CX800." DEFVAL { type-2 } ::= { cxMcVoxEmAdmEntry 11 } cxMcVoxEmAdmMode OBJECT-TYPE SYNTAX INTEGER { normal (1), reverse (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the signalling mode for the administrative E&M port. The signalling mode refers to the wires of the physical connection and how they are connected. The mode you select must match the type the PBX punch block uses or the port will not be able to communicate with it. Options: normal (1) reverse (2) Default Value: normal Configuration Changed: administrative" DEFVAL { normal } ::= { cxMcVoxEmAdmEntry 12 } cxMcVoxEmAdmDialType OBJECT-TYPE SYNTAX INTEGER { dtmf (1), pulse (2), mfR1 (3), mfR2 (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the dialing method of the administrative E&M port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing code. Options: dtmf (1): (Dual Tone Multifrequence) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -7 plus or minus 3 dBm for the lower frequency groups and -5 plus or minus 3 dBm for the higher frequency group. The power level of the higher frequency tone is intentionally increased to compensate for the higher line loss. pulse (2): uses bursts (10 plus or minus 0.5 pps) of the main tone frequency (2280Hz) to generate the codes the user enters. Tones are generated at a level of -4 to -30 dBm for the 2280Hz frequency. The number of pulses during one second indicates the code the user dials. With the E&M interface, the voice station generates and detects pulses. mfR1 (3): R1 signaling protocol MultiFrequency (MF) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -7 dBm0 +- 1 dB (CCITT Recommendation Q.322). The difference in transmission level between the two frequencies comprises a signal that does not exceed 0.5 dB. mfR2 (4): R2 signaling protocol MultiFrequency (MF) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -8 dBm0 +- 1 dB (CCITT Recommendation Q.454). The difference in transmission level between the two frequencies comprises a signal that does not exceed 1 dB. Default Value: dtmf (1) Configuration Changed: administrative" DEFVAL { dtmf } ::= { cxMcVoxEmAdmEntry 13 } cxMcVoxEmAdmSignalType OBJECT-TYPE SYNTAX INTEGER { normal (1), delay (2), wink (3), ac15 (4), openchn (5), r2 (6), mfcr2 (7), isdn (8) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the type of signalling on the administrative E&M port. The signalling type refers to the line seizure technique Options: normal (1) delay (2) wink (3) ac15 (4) openChn (5) R2 (6) MFCR2 (7) isdn (8) Note: If you select 'ac15' you must define the object cxMcVoxEmAdmDialType of this table. Default Value: normal Configuration Changed: administrative" DEFVAL { normal } ::= { cxMcVoxEmAdmEntry 14 } cxMcVoxEmAdmAc15Type OBJECT-TYPE SYNTAX INTEGER { normal (1), delay (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the type of AC15 signals the administrative E&M port uses to seize the line for transmission. This object is only relevant to E&M ports using the AC15 signalling type (as defined using the object cxMcVoxEmAdmSignalType of this table) Options: normal (1) delay (2) Default Value: normal Configuration Changed: administrative" DEFVAL { normal } ::= { cxMcVoxEmAdmEntry 15 } cxMcVoxEmAdmAc15TimeOn OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the length of time, in milliseconds, the AC15 pulse remains on. This object is only relevant to E&M ports using the AC15 signalling type (as defined using the object cxMcVoxEmAdmSignalType of this table) Range of Values: 0 to 60000 Default Value: 60 Configuration Changed: administrative" DEFVAL { 60 } ::= { cxMcVoxEmAdmEntry 16 } cxMcVoxEmAdmAc15TimeOff OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the length of time, in milliseconds, the AC15 pulse remains off. This object is only relevant to E&M ports using the AC15 signalling type (as defined using the object cxMcVoxEmAdmSignalType of this table) Range of Values: 0 to 60000 Default Value: 40 Configuration Changed: administrative" DEFVAL { 40 } ::= { cxMcVoxEmAdmEntry 17 } cxMcVoxEmAdmCnctType OBJECT-TYPE SYNTAX INTEGER { switched (1), auto-connect (2), fixed (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the method the administrative E&M port uses to make connections. Options: switched (1): the port connects each call according to the dialing code the user enters. auto-connect (2): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Any remote can connect to a port with an auto-connect configuration but when the local user initiates the call it always goes to the same remote. fixed (3): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Only the local and remote destinations of the connection can use this port. No other remote location can gain access to this port. Default Value: switched (1) Configuration Changed: administrative" DEFVAL { switched } ::= { cxMcVoxEmAdmEntry 18 } cxMcVoxEmAdmRingType OBJECT-TYPE SYNTAX INTEGER { north-american (1), international (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the ring type of the administrative E&M port. The ring types provide different ring timing to match the different ring cycles in networks. Options: north-american (1) international (2) Default Value: north-american (1) Configuration Changed: administrative" DEFVAL { north-american } ::= { cxMcVoxEmAdmEntry 19 } cxMcVoxEmAdmRmtExt OBJECT-TYPE SYNTAX DisplayString (SIZE (1..5)) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the Remote Extension or Group Id used for auto-connection on the E&M port. The Remote Extension is a numeric dialing code that the user enters to gain access to the remote telephone or fax machine. Auto-connection is the connection method that this port uses. A particular Remote Extension or Group Id has been assigned to the port so that no dialing is required. Note: The number of digits in the Remote Extension is determined by the object cxMcVoxNetNbDigits of the cxMcVox Global Parameters Group. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: administrative" DEFVAL { "000" } --#STARTING-VERSION 1 ::= { cxMcVoxEmAdmEntry 20 } cxMcVoxEmAdmRmtId OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-write STATUS optional DESCRIPTION "Determines the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection via the fixed connection method. With the fixed connection method, a particular Remote Extension or Group Id is assigned to the port so that no dialing is required. The call to the remote is established as soon as the connection is configured. Range of Values: A maximum of 10 alphanumeric characters in upper-case only. You can use any combination of letters and numbers; however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none Configuration Changed: administrative" DEFVAL { " " } --#STARTING-VERSION 1 ::= { cxMcVoxEmAdmEntry 21 } cxMcVoxEmAdmTranspMode OBJECT-TYPE SYNTAX INTEGER { emulate (1), transparent (2) , local (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party has answered to the party to which the call is finally destinated. The Transparent mode is incompatible with Switched type of connection and is automatically disabled when Switched mode is selected (only applies to autoconnect and fixed connections). The Local mode lets the local port answer right away to a seizure. Options: emulate (1): Emulation mode is on transparent (2): Transparent mode on local (3): Local mode on Default Value: emulate (1) Configuration Changed: administrative" DEFVAL { emulate } --#STARTING-VERSION 3 ::= { cxMcVoxEmAdmEntry 22 } cxMcVoxEmAdmFaxEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the state of the Memotec's FAX relay software on the administrative E&M port. When set to 'enable', at both ends, the Memotec's FAX relay software will be used to transfer FAX messages taking into account the 'cxMcVoxEmAdmFaxBw' object. Otherwise, when set to 'disable', at both ends, no FAX relay support is provided, and the FAX goes through the voice coder if supported. Options: disable (1) enable (2) Default Value: enable (2) Configuration Changed: administrative" DEFVAL { enable } --#STARTING-VERSION 8 ::= { cxMcVoxEmAdmEntry 23 } cxMcVoxEmAdmBroadcast OBJECT-TYPE SYNTAX INTEGER { none (1), master (2) , slave (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Cetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Default Value: none (1) Configuration Changed: administrative" DEFVAL { none } --#STARTING-VERSION 10 ::= { cxMcVoxEmAdmEntry 24 } cxMcVoxEmAdmImpedance OBJECT-TYPE SYNTAX INTEGER { i600-ohms (1), i900-ohms (2), att (3), aus (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Displays the input line impedance of the operative E&M interface. The value of this object can be modified in operational mode. Options: i600-ohms (1) i900-ohms (2) att (3) aus (4) Default Value: i600-ohms (1) NOTE: This object is READ-ONLY for the CX800." DEFVAL { i600-ohms } --#STARTING-VERSION 11 ::= { cxMcVoxEmAdmEntry 25 } cxMcVoxEmAdmVoiceConnection OBJECT-TYPE SYNTAX INTEGER { two-wires (1), four-wires (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates which voice path is provided by the E&M interface. Options: two-wires (1) four-wires (2)" --#STARTING-VERSION 11 ::= { cxMcVoxEmAdmEntry 26 } -- ....................................................................... -- cxMcVox ADMINISTRATIVE FXS DRIVER GROUP cxMcVoxFxsAdmTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxFxsAdmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { cxMcVoxDriverAdm 2 } cxMcVoxFxsAdmEntry OBJECT-TYPE SYNTAX CxMcVoxFxsAdmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { cxMcVoxFxsAdmCardUsed, cxMcVoxFxsAdmPortUsed } ::= { cxMcVoxFxsAdmTable 1 } CxMcVoxFxsAdmEntry ::= SEQUENCE { cxMcVoxFxsAdmCardUsed INTEGER, cxMcVoxFxsAdmPortUsed INTEGER, cxMcVoxFxsAdmPortStatus INTEGER, cxMcVoxFxsAdmVocoder INTEGER, cxMcVoxFxsAdmFaxBw INTEGER, cxMcVoxFxsAdmAutoCnx INTEGER, cxMcVoxFxsAdmPathId DisplayString, cxMcVoxFxsAdmTxGain INTEGER, cxMcVoxFxsAdmRxGain INTEGER, cxMcVoxFxsAdmEchoCancel INTEGER, cxMcVoxFxsAdmSignaling INTEGER, cxMcVoxFxsAdmTimeOn INTEGER, cxMcVoxFxsAdmTimeOff INTEGER, cxMcVoxFxsAdmCnctType INTEGER, cxMcVoxFxsAdmRingType INTEGER, cxMcVoxFxsAdmImpedance INTEGER, cxMcVoxFxsAdmDialType INTEGER, cxMcVoxFxsAdmDidSignalType INTEGER, cxMcVoxFxsAdmRmtExt DisplayString, cxMcVoxFxsAdmRmtId DisplayString, cxMcVoxFxsAdmTranspMode INTEGER, cxMcVoxFxsAdmFaxEnable INTEGER, cxMcVoxFxsAdmBroadcast INTEGER } -- USER MODE OBJECTS: cxMcVoxFxsAdmCardUsed OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default: none" ::= { cxMcVoxFxsAdmEntry 1 } cxMcVoxFxsAdmPortUsed OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the number of the voice port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card only has 1 port CX1000: 1 or 2 Default Value: none" ::= { cxMcVoxFxsAdmEntry 2 } cxMcVoxFxsAdmPortStatus OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the functional status of the administrative port. Options: disable (1): port is not functional enable (2): port is up and active Default Value: disable (1) Configuration Changed: administrative" DEFVAL { disable } ::= { cxMcVoxFxsAdmEntry 3 } cxMcVoxFxsAdmVocoder OBJECT-TYPE SYNTAX INTEGER { bps5800 (1), bps8000 (2), kbps40 (3), kbps32 (4), kbps24 (5), kbps16 (6), opt7 (7), opt8 (8) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the transmission speed (in bits per second) of the compressed voice stream on the administrative FXS port. Defining the speed also sets the ACELP voice compression ratio. Options: bps5800 (1): compresses at a higher rate and uses slightly less bandwidth. bps8000 (2): compresses at approximately an 8:1 ratio (lower rate) with a higher quality voice sound at the receiving end. opt3 (3): ADPCM 40. opt4 (4): ADPCM 32. opt5 (5): ADPCM 24. opt6 (6): ADPCM 16. opt7 (7): Memotec use only. opt8 (8): Memotec use only. Default Value: bps8000 (2) Configuration Changed: administrative" DEFVAL { bps8000 } ::= { cxMcVoxFxsAdmEntry 4 } cxMcVoxFxsAdmFaxBw OBJECT-TYPE SYNTAX INTEGER { bps2400 (1), bps4800 (2), bps7200 (3), bps9600 (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the speed (in bits per second) of the FAX channel on the administrative FXS port. This value also determines the bandwidth required to pass FAX traffic through the voice software.This value can be set to match the speed of your FAX machine or it can be lowered to reduce bandwidth allocation. Options: bps2400 (1) bps4800 (2) bps7200 (3) bps9600 (4) Default Value: bps7200 (3) Configuration Changed: administrative" DEFVAL { bps7200 } ::= { cxMcVoxFxsAdmEntry 5 } -- obsoleted (has been redefined) cxMcVoxFxsAdmAutoCnx OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS obsolete DESCRIPTION "obsolete" DEFVAL { no } ::= { cxMcVoxFxsAdmEntry 6 } cxMcVoxFxsAdmPathId OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS deprecated DESCRIPTION "Path IDs no longer exist with the new Voice Routing (VR) scheme. The Path ID is a numeric dialing code the user enters to gain access to the remote telephone or fax machine. Note: The number of digits in the Path ID must match the value of the object cxMcVoxPathAdmPathLng of the cxMcVox Administrative Path Group Range of Values: 1 to 4 digits Default Value: none" --#ENDING-VERSION 1 DEFVAL { "000" } ::= { cxMcVoxFxsAdmEntry 7 } cxMcVoxFxsAdmTxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the value defining the sound intensity (loudness) of voice transmissions on the administrative FXS port. The transmission gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Transmission gains should be modified during a connection (i.e. dynamically) as changes in the value affect the local listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: administrative" DEFVAL { 960 } ::= { cxMcVoxFxsAdmEntry 8 } cxMcVoxFxsAdmRxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the value defining the sound intensity (loudness) of voice reception on the administrative FXS port. The reception gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Reception gains should be modified during a connection (i.e. dynamically) as changes in the value affect the remote listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: administrative" DEFVAL { 960 } ::= { cxMcVoxFxsAdmEntry 9 } cxMcVoxFxsAdmEchoCancel OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the state of echo cancellation on the administrative FXS port. When set to 'enable' at both the local and remote ends, echo cancellation stops echoes from the remote that are heard through the receiver at the local end. Options: disable (1) enable (2) Default Value: enable (2) Configuration Changed: administrative" DEFVAL { enable } ::= { cxMcVoxFxsAdmEntry 10 } cxMcVoxFxsAdmSignaling OBJECT-TYPE SYNTAX INTEGER { ground-start (1), loop-start (2), did (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the type of signalling the administrative FXS port uses to seize the line. Options: ground-start (1) loop-start (2) did (3) Default Value: loop-start (2) Configuration Changed: administrative" DEFVAL { loop-start } ::= { cxMcVoxFxsAdmEntry 11 } -- obsolete object (has been redefined) cxMcVoxFxsAdmTimeOn OBJECT-TYPE SYNTAX INTEGER (10..10000) ACCESS read-write STATUS obsolete DESCRIPTION "obsolete" DEFVAL { 2000 } ::= { cxMcVoxFxsAdmEntry 12 } -- obsolete object (has been redefined) cxMcVoxFxsAdmTimeOff OBJECT-TYPE SYNTAX INTEGER (10..10000) ACCESS read-write STATUS obsolete DESCRIPTION "obsolete" DEFVAL { 4000 } ::= { cxMcVoxFxsAdmEntry 13 } cxMcVoxFxsAdmCnctType OBJECT-TYPE SYNTAX INTEGER { switched (1), auto-connect (2), fixed (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the method the administrative FXS port uses to make connections. Options: switched (1): the port connects each call according to the dialing code the user enters. auto-connect (2): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Any remote can connect to a port with an auto-connect configuration but when the local user initiates the call it always goes to the same remote. fixed (3): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Only the local and remote destinations of the connection can use this port. No other remote location can gain access to this port. Default Value: switched (1) Configuration Changed: administrative" DEFVAL { switched } ::= { cxMcVoxFxsAdmEntry 14 } cxMcVoxFxsAdmRingType OBJECT-TYPE SYNTAX INTEGER { north-american (1), international (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the ring type of the administrative FXS port. The ring types provide different ring timing to match the different ring cycles in networks. Options: north-american (1) international (2) Default Value: north-american (1) Configuration Changed: administrative" DEFVAL { north-american } ::= { cxMcVoxFxsAdmEntry 15 } cxMcVoxFxsAdmImpedance OBJECT-TYPE SYNTAX INTEGER { i600-ohms (1), i900-ohms (2), att (3), aus (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the input line impedance of the administrative FXS port. Options: i600-ohms (1) i900-ohms (2) att (3) aus (4) Default Value: i600-ohms (1) Configuration Changed: administrative NOTE: The option aus(4) is added only starting at version 11. NOTE: This object is READ-ONLY for the CX800." DEFVAL { i600-ohms } ::= { cxMcVoxFxsAdmEntry 16 } cxMcVoxFxsAdmDialType OBJECT-TYPE SYNTAX INTEGER { dtmf (1), pulse (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the dialing method of the administrative FXS port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing code. Options: dtmf (1): (Dual Tone Multifrequence) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -7 plus or minus 3 dBm for the lower frequency groups and -5 plus or minus 3 dBm for the higher frequency group. The power level of the higher frequency tone is intentionally increased to compensate for the higher line loss. pulse (2): uses bursts (10 plus or minus 0.5 pps) of the main tone frequency (2280Hz) to generate the codes the user enters. Tones are generated at a level of -4 to -30 dBm for the 2280Hz frequency. The number of pulses during one second indicates the code the user dials. With the E&M interface, the voice station generates and detects pulses. Default Value: dtmf (1) Configuration Changed: administrative" DEFVAL { dtmf } ::= { cxMcVoxFxsAdmEntry 17 } cxMcVoxFxsAdmDidSignalType OBJECT-TYPE SYNTAX INTEGER { normal (1), delay (2), wink (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Note: This object only applies to those ports with the object cxMcVoxFxsAdmSignaling set to 'did'. Determines the type of signaling on the administrative FXS port. The signaling type refers to the line seizure technique. Options: normal (1) delay (2) wink (3) Default Value: normal (1) Configuration Changed: administrative" DEFVAL { normal } ::= { cxMcVoxFxsAdmEntry 18 } cxMcVoxFxsAdmRmtExt OBJECT-TYPE SYNTAX DisplayString (SIZE (1..5)) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the Remote Extension or Group Id used for auto-connection on the FXS port. The Remote Extension is a numeric dialing code that the user enters to access the remote telephone or fax machine. Auto-connection is the connection method that this port uses. A particular Remote Extension or Group Id has been assigned to the port so that no dialing is required. Note: The number of digits in the Remote Extension is determined by the object cxMcVoxNetNbDigits of the cxMcVox Global Parameters Group. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: administrative" DEFVAL { "000" } --#STARTING-VERSION 1 ::= { cxMcVoxFxsAdmEntry 19 } cxMcVoxFxsAdmRmtId OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-write STATUS optional DESCRIPTION "Determines the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection with fixed type connection. With the fixed connection method, a particular Remote Extension or Group Id is assigned to the port so that no dialing is required. The call to the remote is established as soon as the connection is configured. Range of Values: a maximum of 10 alphanumeric characters in upper-case only. You can use any combination of letters and numbers; however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none Configuration Changed: administrative" DEFVAL { " " } --#STARTING-VERSION 1 ::= { cxMcVoxFxsAdmEntry 20 } cxMcVoxFxsAdmTranspMode OBJECT-TYPE SYNTAX INTEGER { emulate (1), transparent (2) , local (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party has answered to the party to which the call is finally destinated. The Transparent mode is incompatible with Switched type of connection and is automatically disabled when Switched mode is selected (only applies to autoconnect and fixed connections). The Local mode lets the local port answer right away to a seizure. Options: emulate (1): Emulation mode is on transparent (2): Transparent mode on local (3): Local mode on Default Value: emulate (1) Configuration Changed: administrative" DEFVAL { emulate } --#STARTING-VERSION 3 ::= { cxMcVoxFxsAdmEntry 21 } cxMcVoxFxsAdmFaxEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the state of the Memotec's FAX relay software on the administrative E&M port. When set to 'enable', at both ends, the Memotec's FAX relay software will be used to transfer FAX messages taking into account the 'cxMcVoxFxsAdmFaxBw' object. Otherwise, when set to 'disable', at both ends, no FAX relay support is provided, and the FAX goes through the voice coder if supported. Options: disable (1) enable (2) Default Value: enable (2) Configuration Changed: administrative" DEFVAL { enable } --#STARTING-VERSION 8 ::= { cxMcVoxFxsAdmEntry 22 } cxMcVoxFxsAdmBroadcast OBJECT-TYPE SYNTAX INTEGER { none (1), master (2) , slave (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Cetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Default Value: none (1) Configuration Changed: administrative" DEFVAL { none } --#STARTING-VERSION 10 ::= { cxMcVoxFxsAdmEntry 23 } -- .......................................................................... -- cxMcVox ADMINISTRATIVE FXO DRIVER GROUP cxMcVoxFxoAdmTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxFxoAdmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "cx Voice Station Administrative FXO Table." ::= { cxMcVoxDriverAdm 3 } cxMcVoxFxoAdmEntry OBJECT-TYPE SYNTAX CxMcVoxFxoAdmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "cx Voice Station Administrative FXO Entry " INDEX { cxMcVoxFxoAdmCardUsed, cxMcVoxFxoAdmPortUsed } ::= { cxMcVoxFxoAdmTable 1 } CxMcVoxFxoAdmEntry ::= SEQUENCE { cxMcVoxFxoAdmCardUsed INTEGER, cxMcVoxFxoAdmPortUsed INTEGER, cxMcVoxFxoAdmPortStatus INTEGER, cxMcVoxFxoAdmVocoder INTEGER, cxMcVoxFxoAdmFaxBw INTEGER, cxMcVoxFxoAdmAutoCnx INTEGER, cxMcVoxFxoAdmPathId DisplayString, cxMcVoxFxoAdmTxGain INTEGER, cxMcVoxFxoAdmRxGain INTEGER, cxMcVoxFxoAdmEchoCancel INTEGER, cxMcVoxFxoAdmSignaling INTEGER, cxMcVoxFxoAdmCnctType INTEGER, cxMcVoxFxoAdmRingType INTEGER, cxMcVoxFxoAdmImpedance INTEGER, cxMcVoxFxoAdmDialType INTEGER, cxMcVoxFxoAdmDidSignalType INTEGER, cxMcVoxFxoAdmRmtExt DisplayString, cxMcVoxFxoAdmRmtId DisplayString, cxMcVoxFxoAdmTranspMode INTEGER, cxMcVoxFxoAdmFaxEnable INTEGER, cxMcVoxFxoAdmBroadcast INTEGER } -- USER MODE OBJECTS: cxMcVoxFxoAdmCardUsed OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the slot number of the voice I/O card. You cannot modify this object. It is a display that the software provides. Range of Values CX900: 1 to 6 CX1000: 1 to 8 Default: none" ::= { cxMcVoxFxoAdmEntry 1 } cxMcVoxFxoAdmPortUsed OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the number of the voice I/O port. You cannot modify this object. It is a display that the software provides. Options: CX900: 1 is the only acceptable value. Each I/O card only has 1 port. CX1000: up to 15 for the DI600 Default: none" ::= { cxMcVoxFxoAdmEntry 2 } cxMcVoxFxoAdmPortStatus OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the functional status of the administrative port. Options: disable (1): port is not functional enable (2): port is up and active Default Value: disable (1) Configuration Changed: administrative" DEFVAL { disable } ::= { cxMcVoxFxoAdmEntry 3 } cxMcVoxFxoAdmVocoder OBJECT-TYPE SYNTAX INTEGER { bps5800 (1), bps8000 (2), kbps40 (3), kbps32 (4), kbps24 (5), kbps16 (6), opt7 (7), opt8 (8) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the transmission speed (in bits per second) of the compressed voice stream on the administrative FXO port. Defining the speed also sets the ACELP voice compression ratio. Options: bps5800 (1): compresses at a higher rate and uses slightly less bandwidth. bps8000 (2): compresses at approximately an 8:1 ratio (lower rate) with a higher quality voice sound at the receiving end. opt3 (3): ADPCM 40. opt4 (4): ADPCM 32. opt5 (5): ADPCM 24. opt6 (6): ADPCM 16. opt7 (7): Memotec use only. opt8 (8): Memotec use only. Default Value: bps8000 (2) Configuration Changed: administrative" DEFVAL { bps8000 } ::= { cxMcVoxFxoAdmEntry 4 } cxMcVoxFxoAdmFaxBw OBJECT-TYPE SYNTAX INTEGER { bps2400 (1), bps4800 (2), bps7200 (3), bps9600 (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the speed (in bits per second) of the FAX channel on the administrative FXO port. This value also determines the bandwidth required to pass FAX traffic through the voice software. This value can be set to match the speed of your FAX machine or it can be lowered to reduce bandwidth allocation. Options: bps2400 (1) bps4800 (2) bps7200 (3) bps9600 (4) Default Value: bps7200 (3) Configuration Changed: administrative" DEFVAL { bps7200 } ::= { cxMcVoxFxoAdmEntry 5 } -- obsoleted (has been redefined) cxMcVoxFxoAdmAutoCnx OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS obsolete DESCRIPTION "obsolete" DEFVAL { no } ::= { cxMcVoxFxoAdmEntry 6 } cxMcVoxFxoAdmPathId OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS deprecated DESCRIPTION "Path IDs no longer exist with the new Voice Routing (VR) scheme. The Path ID is a numeric dialing code the user enters to gain access to the remote telephone or fax machine. Note: The number of digits in the Path ID must match the value of the object cxMcVoxPathAdmPathLng of the cxMcVox Administrative Path Group. Range of Values: 1 to 4 numeric digits Default Value: none Configuration Changed: administrative" --#ENDING-VERSION 1 DEFVAL { "000" } ::= { cxMcVoxFxoAdmEntry 7 } cxMcVoxFxoAdmTxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the value defining the sound intensity (loudness) of voice transmission on the administrative FXO port. The transmission gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Transmission gains should be modified during a connection (i.e. dynamically) as changes in the value affect the local listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: administrative" DEFVAL { 960 } ::= { cxMcVoxFxoAdmEntry 8 } cxMcVoxFxoAdmRxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the value defining the sound intensity (loudness) of voice reception on the administrative FXO port. The reception gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Reception gains should be modified during a connection (i.e. dynamically) as changes in the value affect the remote listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: administrative" DEFVAL { 960 } ::= { cxMcVoxFxoAdmEntry 9 } cxMcVoxFxoAdmEchoCancel OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the state of echo cancellation on the administrative FXO port. When set to 'enable' at both the local and remote ends, echo cancellation stops echoes from the remote that are heard through the receiver at the local end. Options: disable (1) enable (2) Default Value: enable (2) Configuration Changed: administrative" DEFVAL { enable } ::= { cxMcVoxFxoAdmEntry 10 } cxMcVoxFxoAdmSignaling OBJECT-TYPE SYNTAX INTEGER { ground-start (1), loop-start (2), did (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the type of signalling the administrative FXO port uses to seize the line. Options: ground-start (1) loop-start (2) did (3) Default Value: loop-start (2) Configuration Changed: administrative" DEFVAL { loop-start } ::= { cxMcVoxFxoAdmEntry 11 } cxMcVoxFxoAdmCnctType OBJECT-TYPE SYNTAX INTEGER { switched (1), auto-connect (2), fixed (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the method the administrative FXO port uses to make connections. Options: switched (1): the port connects each call according to the dialing code the user enters. auto-connect (2): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Any remote can connect to a port with an auto-connect configuration but when the local user initiates the call it always goes to the same remote. fixed (3): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Only the local and remote destinations of the connection can use this port. No other remote location can gain access to this port. Default Value: switched (1) Configuration Changed: administrative" DEFVAL { switched } ::= { cxMcVoxFxoAdmEntry 12 } cxMcVoxFxoAdmRingType OBJECT-TYPE SYNTAX INTEGER { north-american (1), international (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the ring type of the administrative FXO port. The ring types provide different ring timing to match the different ring cycles in networks. Options: north-american (1) international (2) Default Value: north-american (1) Configuration Changed: administrative" DEFVAL { north-american } ::= { cxMcVoxFxoAdmEntry 13 } cxMcVoxFxoAdmImpedance OBJECT-TYPE SYNTAX INTEGER { i600-ohms (1), i900-ohms (2), att (3), aus (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the input line impedance of the administrative FXO interface. Options: i600-ohms (1) i900-ohms (2) att (3) aus (4) Default Value: i600-ohms (1) Configuration Changed: administrative NOTE: The option aus(4) is added only starting at version 11. NOTE: This object is READ-ONLY for the CX800." DEFVAL { i600-ohms } ::= { cxMcVoxFxoAdmEntry 14 } cxMcVoxFxoAdmDialType OBJECT-TYPE SYNTAX INTEGER { dtmf (1), pulse (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the dialing method of the administrative FXO port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing code. Options: dtmf (1): (Dual Tone Multifrequence) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -7 plus or minus 3 dBm for the lower frequency groups and -5 plus or minus 3 dBm for the higher frequency group. The power level of the higher frequency tone is intentionally increased to compensate for the higher line loss. pulse (2): uses bursts (10 plus or minus 0.5 pps) of the main tone frequency (2280Hz) to generate the codes the user enters. Tones are generated at a level of -4 to -30 dBm for the 2280Hz frequency. The number of pulses during one second indicates the code the user dials. With the E&M interface, the voice station generates and detects pulses. Default Value: dtmf 1) Configuration Changed: administrative" DEFVAL { dtmf } ::= { cxMcVoxFxoAdmEntry 15 } cxMcVoxFxoAdmDidSignalType OBJECT-TYPE SYNTAX INTEGER { normal (1), delay (2), wink (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Note: This object only applies to those ports with the object cxMcVoxFxoAdmSignaling set to 'did'. Determines the type of signaling on the administrative FXO port. The signaling type refers to the line seizure technique. Options: normal (1) delay (2) wink (3) Default Value: normal (1) Configuration Changed: administrative" DEFVAL { normal } ::= { cxMcVoxFxoAdmEntry 16 } cxMcVoxFxoAdmRmtExt OBJECT-TYPE SYNTAX DisplayString (SIZE (1..5)) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the Remote Extension or Group Id used for auto-connection on the FXO port. The Remote Extension is a numeric dialing code that the user enters to gain access to the remote telephone or fax machine. Auto-connection is the connection method that this port uses. A particular Remote Extension or Group Id has been assigned to the port so that no dialing is required. Note: The number of digits in the Remote Extension is determined by the object cxMcVoxNetNbDigits of the cxMcVox Global Parameters Group. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: administrative" DEFVAL { "000" } --#STARTING-VERSION 1 ::= { cxMcVoxFxoAdmEntry 17 } cxMcVoxFxoAdmRmtId OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-write STATUS optional DESCRIPTION "Determines the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection with fixed type connection. With the fixed connection method, a particular Remote Extension or Group Id is assigned to the port so that no dialing is required. The call to the remote is established as soon as the connection is configured. Range of Values: a maximum of 10 alphanumeric characters in upper-case only. You can use any combination of letters and numbers; however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none Configuration Changed: administrative" DEFVAL { " " } --#STARTING-VERSION 1 ::= { cxMcVoxFxoAdmEntry 18 } cxMcVoxFxoAdmTranspMode OBJECT-TYPE SYNTAX INTEGER { emulate (1), transparent (2) , local (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party has answered to the party to which the call is finally destinated. The Transparent mode is incompatible with Switched type of connection and is automatically disabled when Switched mode is selected (only applies to autoconnect and fixed connections). The Local mode lets the local port answer right away to a seizure. Options: emulate (1): Emulation mode is on transparent (2): Transparent mode on local (3): Local mode on Default Value: emulate (1) Configuration Changed: administrative" DEFVAL { emulate } --#STARTING-VERSION 3 ::= { cxMcVoxFxoAdmEntry 19 } cxMcVoxFxoAdmFaxEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the state of the Memotec's FAX relay software on the administrative E&M port. When set to 'enable', at both ends, the Memotec's FAX relay software will be used to transfer FAX messages taking into account the 'cxMcVoxFxoAdmFaxBw' object. Otherwise, when set to 'disable', at both ends, no FAX relay support is provided, and the FAX goes through the voice coder if supported. Options: disable (1) enable (2) Default Value: enable (2) Configuration Changed: administrative" DEFVAL { enable } --#STARTING-VERSION 8 ::= { cxMcVoxFxoAdmEntry 20 } cxMcVoxFxoAdmBroadcast OBJECT-TYPE SYNTAX INTEGER { none (1), master (2) , slave (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Cetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Default Value: none (1) Configuration Changed: administrative" DEFVAL { none } --#STARTING-VERSION 10 ::= { cxMcVoxFxoAdmEntry 21 } -- ========================================================================= -- cxMcVox OPERATIONAL DRIVER GROUP cxMcVoxDriverOpe OBJECT IDENTIFIER ::= { cxMcVox 9 } -- cxMcVox OPERATIONAL E&M DRIVER GROUP cxMcVoxEmOpeTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxEmOpeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { cxMcVoxDriverOpe 1 } cxMcVoxEmOpeEntry OBJECT-TYPE SYNTAX CxMcVoxEmOpeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { cxMcVoxEmOpeCardUsed, cxMcVoxEmOpePortUsed } ::= { cxMcVoxEmOpeTable 1 } CxMcVoxEmOpeEntry ::= SEQUENCE { cxMcVoxEmOpeCardUsed INTEGER, cxMcVoxEmOpePortUsed INTEGER, cxMcVoxEmOpePortStatus INTEGER, cxMcVoxEmOpeVocoder INTEGER, cxMcVoxEmOpeFaxBw INTEGER, cxMcVoxEmOpeAutoCnx INTEGER, cxMcVoxEmOpePathId DisplayString, cxMcVoxEmOpeTxGain INTEGER, cxMcVoxEmOpeRxGain INTEGER, cxMcVoxEmOpeEchoCancel INTEGER, cxMcVoxEmOpeType INTEGER, cxMcVoxEmOpeMode INTEGER, cxMcVoxEmOpeDialType INTEGER, cxMcVoxEmOpeSignalType INTEGER, cxMcVoxEmOpeAc15Type INTEGER, cxMcVoxEmOpeAc15TimeOn INTEGER, cxMcVoxEmOpeAc15TimeOff INTEGER, cxMcVoxEmOpeCnctType INTEGER, cxMcVoxEmOpeRingType INTEGER, cxMcVoxEmOpeRmtExt DisplayString, cxMcVoxEmOpeRmtId DisplayString, cxMcVoxEmOpeTranspMode INTEGER, cxMcVoxEmOpeFaxEnable INTEGER, cxMcVoxEmOpeBroadcast INTEGER, cxMcVoxEmOpeImpedance INTEGER, cxMcVoxEmOpeVoiceConnection INTEGER } -- USER MODE OBJECTS: cxMcVoxEmOpeCardUsed OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default: none" ::= { cxMcVoxEmOpeEntry 1 } cxMcVoxEmOpePortUsed OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the number of the voice I/O port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card has only 1 port. CX1000: up to 15 for the DI600 Default: none" ::= { cxMcVoxEmOpeEntry 2 } cxMcVoxEmOpePortStatus OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), no-voice-io (3), boot-err-1 (31), boot-err-2 (32), boot-err-3 (33), boot-err-4 (34), appl-err-1 (41), appl-err-2 (42), appl-err-3 (43), appl-err-4 (44) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the functional status of the operative port. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmportStatus of the cxMcVox Administrative Driver Group. Options: disable (1): port is not functional enable (2): port is up and active no-voice-io (3): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-1 (31): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-2 (32): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-3 (33): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-4 (34): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-1 (41): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-2 (42): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-3 (43): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-4 (44): Memotec use only. Contact Memotec service personnel if this value displays. Default Value: disable (1)" DEFVAL { disable } ::= { cxMcVoxEmOpeEntry 3 } cxMcVoxEmOpeVocoder OBJECT-TYPE SYNTAX INTEGER { bps5800 (1), bps8000 (2), kbps40 (3), kbps32 (4), kbps24 (5), kbps16 (6), opt7 (7), opt8 (8) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the transmission speed (in bits per second) of the compressed voice stream on the operative E&M port. Defining the speed also sets the ACELP voice compression ratio. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmVocoder of the cxMcVox Administrative Driver Group. Options: bps5800 (1): compresses at a higher rate and uses slightly less bandwidth. bps8000 (2): compresses at approximately an 8:1 ratio (lower rate) with a higher quality voice sound at the receiving end. opt3 (3): ADPCM 40. opt4 (4): ADPCM 32. opt5 (5): ADPCM 24. opt6 (6): ADPCM 16. opt7 (7): Memotec use only. opt8 (8): Memotec use only. Default Value: bps8000" DEFVAL { bps8000 } ::= { cxMcVoxEmOpeEntry 4 } cxMcVoxEmOpeFaxBw OBJECT-TYPE SYNTAX INTEGER { bps2400 (1), bps4800 (2), bps7200 (3), bps9600 (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the speed (in bits per second) of the FAX channel on the operative E&M port. This value also determines the bandwidth required to pass FAX traffic through the voice software. This value can be set to match the speed of your FAX machine or it can be lowered to reduce bandwidth allocation. Options: bps2400 (1) bps4800 (2) bps7200 (3) bps9600 (4) Default Value: bps7200 (3) Configuration Changed: operative" DEFVAL { bps7200 } ::= { cxMcVoxEmOpeEntry 5 } -- obsoleted object (has been redefined) cxMcVoxEmOpeAutoCnx OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-only STATUS obsolete DESCRIPTION "obsolete" DEFVAL { no } ::= { cxMcVoxEmOpeEntry 6 } cxMcVoxEmOpePathId OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only STATUS deprecated DESCRIPTION "Path IDs no longer exist in the new Voice Routing (VR) scheme. The Path ID is a numeric dialing code the user enters to gain access to the remote telephone or fax machine. Note: The number of digits in the Path ID must match the value of the object cxMcVoxPathOpePathLng of the cxMcVox Operative Path Group. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmPathId of the cxMcVox Administrative Driver Group. Range of Values: 1 to 4 numeric digits Default Value: none" --#ENDING-VERSION 1 ::= { cxMcVoxEmOpeEntry 7 } cxMcVoxEmOpeTxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the value defining the sound intensity (loudness) of voice transmissions on the operative E&M port. The transmission gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Transmission gains should be modified during a connection (i.e. dynamically) as changes in the value affect the local listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: operative" DEFVAL { 960 } ::= { cxMcVoxEmOpeEntry 8 } cxMcVoxEmOpeRxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the value defining the sound intensity (loudness) of voice reception on the operative E&M port. The reception gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Reception gains should be modified during a connection (i.e. dynamically) as changes in the value affect the remote listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: operative" DEFVAL { 960 } ::= { cxMcVoxEmOpeEntry 9 } cxMcVoxEmOpeEchoCancel OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the state of echo cancellation on the operative E&M port. When set to 'enable' at both the local and remote ends, echo cancellation stops echoes from the remote that are heard through the receiver at the local end. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmEchoCancel of the cxMcVox Administrative Driver Group. Options: disable (1) enable (2) Default Value: enable (2)" DEFVAL { enable } ::= { cxMcVoxEmOpeEntry 10 } cxMcVoxEmOpeType OBJECT-TYPE SYNTAX INTEGER { type-1 (1), type-2 (2), type-3 (3), type-4 (4), type-5 (5) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the type of E&M interface of the operative E&M port. Each of the five interface types has a unique signal-to-wire pattern. Be sure to select the interface type that matches your PBX. You cannot modify this object. If you want to change thevalue you must modify the object cxMcVoxEmAdmType of the cxMcVox Administrative Driver Group. Options: type-1 (1) type-2 (2) type-3 (3) type-4 (4) type-5 (5) Default Value: type-2 (2)" DEFVAL { type-2 } ::= { cxMcVoxEmOpeEntry 11 } cxMcVoxEmOpeMode OBJECT-TYPE SYNTAX INTEGER { normal (1), reverse (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the signalling mode for the operative E&M port. The signalling mode refers to the wires of the physical connection and how they are connected. The mode you select must match the type the PBX punch block uses or the port will not be able to communicate with it. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmMode of the cxMcVox Administrative Driver Group. Options: normal (1) reverse (2) Default Value: normal (1)" DEFVAL { normal } ::= { cxMcVoxEmOpeEntry 12 } cxMcVoxEmOpeDialType OBJECT-TYPE SYNTAX INTEGER { dtmf (1), pulse (2), mfR1 (3), mfR2 (4) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the dialing method of the operative E&M port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing code. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmDialType of the cxMcVox Administrative Driver Group Options: dtmf (1): Dual Tone MultiFrequency uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -7 plus or minus 3 dBm for the lower frequency groups and -5 plus or minus 3 dBm for the higher frequency group. The power level of the higher frequency tone is intentionally increased to compensate for the higher line loss. pulse (2): uses bursts (10 plus or minus 0.5 pps) of the main tone frequency (2280Hz) to generate the codes the user enters. Tones are generated at a level of -4 to -30 dBm for the 2280Hz frequency. The number of pulses during one second indicates the code the user dials. With the E&M interface, the voice station generates and detects pulses. mfR1 (3): R1 signaling protocol MultiFrequency (MF) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -7 dBm0 +- 1 dB (CCITT Recommendation Q.322). The difference in transmission level between the two frequencies comprises a signal that does not exceed 0.5 dB. mfR2 (4): R2 signaling protocol MultiFrequency (MF) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -8 dBm0 +- 1 dB (CCITT Recommendation Q.454). The difference in transmission level between the two frequencies comprises a signal that does not exceed 1 dB. Default Value: dtmf (1)" DEFVAL { dtmf } ::= { cxMcVoxEmOpeEntry 13 } cxMcVoxEmOpeSignalType OBJECT-TYPE SYNTAX INTEGER { normal (1), delay (2), wink (3), ac15 (4), openchn (5), r2 (6), mfcr2 (7), isdn (8) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the type of signalling the operative E&M port uses to seize the line. You cannot modify this object. If you want to change the value you must modify thee object cxMcVoxEmAdmSignalType of the cxMcVox Administrative Driver Group. Options: normal (1) delay (2) wink (3) ac15 (4) openChn (5) R2 (6) MFCR2 (7) isdn (8) Default Value: normal (1)" DEFVAL { normal } ::= { cxMcVoxEmOpeEntry 14 } cxMcVoxEmOpeAc15Type OBJECT-TYPE SYNTAX INTEGER { normal (1), delay (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the type of AC15 signals the operative E&M port uses to seize the line for transmission. This object is only relevant to E&M ports using the AC15 signalling type (as defined using the object cxMcVoxEmAdmSignalType of the cxMcVox Administrative Driver Group). You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmAcType of the cxMcVox Administrative Driver Group. Options: normal (1) delay (2) Default Value: normal" DEFVAL { normal } ::= { cxMcVoxEmOpeEntry 15 } cxMcVoxEmOpeAc15TimeOn OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the length of time, in milliseconds, the AC15 pulse remains on. This object is only relevant to E&M ports using the AC15 signalling type (as defined using the object cxMcVoxEmOpeSignalType of this table). Range of Values: 0 to 60000 Default Value: 60 Configuration Changed: operative" DEFVAL { 60 } ::= { cxMcVoxEmOpeEntry 16 } cxMcVoxEmOpeAc15TimeOff OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the length of time, in milliseconds, the AC15 pulse remains off. This object is only relevant to E&M ports using the AC15 signalling type (as defined using the object cxMcVoxEmOpeSignalType of this table). Range of Values: 0 to 60000 Default Value: 40 Configuration Changed: operative" DEFVAL { 40 } ::= { cxMcVoxEmOpeEntry 17 } cxMcVoxEmOpeCnctType OBJECT-TYPE SYNTAX INTEGER { switched (1), auto-connect (2), fixed (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the method the operative E&M port uses to make connections. This object is only relevant to E&M ports using the AC15 signalling type (as defined using the object cxMcVoxEmOpeSignalType of this table). You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmCnctType of the cxMcVox Administrative Driver Group. Options: switched (1): the port connects each call according to the dialing code the user enters. auto-connect (2): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Any remote can connect to a port with an auto-connect configuration but when the local user initiates the call it always goes to the same remote. fixed (3): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Only the local and remote destinations of the connection can use this port. No other remote location can gain access to this port. Default Value: switched (1)" DEFVAL { switched } ::= { cxMcVoxEmOpeEntry 18 } cxMcVoxEmOpeRingType OBJECT-TYPE SYNTAX INTEGER { north-american (1), international (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the ring type of the operative E&M port. The ring types provide different ring timing to match the different ring cycles in networks. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmRingType of the cxMcVox Administrative Driver Group. Options: north-american (1) international (2) Default Value: north-american (1)" DEFVAL { north-american } ::= { cxMcVoxEmOpeEntry 19 } cxMcVoxEmOpeRmtExt OBJECT-TYPE SYNTAX DisplayString (SIZE (1..5)) ACCESS read-only STATUS mandatory DESCRIPTION "Determines the Remote Extension or Group Id used for auto-connection on the E&M port. The Remote Extension is a numeric dialing code that the user enters to access to the remote telephone or fax machine. Auto-connection is the connection method that this port uses. A particular Remote Extension or Group Id has been assigned to the port so that no dialing is required. Note: The number of digits in the Remote Extension is determined by the object cxMcVoxNetNbDigits of the cxMcVox Global Parameters Group. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: operative" --#STARTING-VERSION 1 ::= { cxMcVoxEmOpeEntry 20 } cxMcVoxEmOpeRmtId OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only STATUS optional DESCRIPTION "Displays the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection via the fixed connection method. You cannot modify this object. If you want to change the ID you must modify the object cxMcVoxEmAdmRmtId (of this table). With the fixed connection method, a particular Remote Extension or Group Id is assigned to the port so that no dialing is required. The call to the remote is established as soon as the connection is configured. Range of Values: a maximum of 10 alphanumeric characters in upper-case only. You can use any combination of letters and numbers; however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none" --#STARTING-VERSION 1 ::= { cxMcVoxEmOpeEntry 21 } cxMcVoxEmOpeTranspMode OBJECT-TYPE SYNTAX INTEGER { emulate (1), transparent (2) , local (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Determines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party has answered to the party to which the call is finally destinated. The Transparent mode is incompatible with Switched type of connection and is automatically disabled when Switched mode is selected (only applies to autoconnect and fixed connections). The Local mode lets the local port answer right away to a seizure. Options: emulate (1): Emulation mode is on transparent (2): Transparent mode on local (3): Local mode on Default Value: emulate (1) Configuration Changed: operational" DEFVAL { emulate } --#STARTING-VERSION 3 ::= { cxMcVoxEmOpeEntry 22 } cxMcVoxEmOpeFaxEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the state of the FAX on the operative E&M port. When set to 'enable' at both the local and remote ends, the FAX will be enabled. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmFaxEnable of the cxMcVox Administrative Driver Group. Options: disable (1) enable (2) Default Value: enable (2)" DEFVAL { enable } --#STARTING-VERSION 8 ::= { cxMcVoxEmOpeEntry 23 } cxMcVoxEmOpeBroadcast OBJECT-TYPE SYNTAX INTEGER { none (1), master (2) , slave (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Cetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Default Value: none (1)" DEFVAL { none } --#STARTING-VERSION 10 ::= { cxMcVoxEmOpeEntry 24 } cxMcVoxEmOpeImpedance OBJECT-TYPE SYNTAX INTEGER { i600-ohms (1), i900-ohms (2), att (3), aus (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Displays the input line impedance of the operative E&M interface. The value of this object can be modified in operational mode. Options: i600-ohms (1) i900-ohms (2) att (3) aus (4) Default Value: i600-ohms (1) NOTE: This object is READ-ONLY for the CX800." DEFVAL { i600-ohms } --#STARTING-VERSION 11 ::= { cxMcVoxEmOpeEntry 25 } cxMcVoxEmOpeVoiceConnection OBJECT-TYPE SYNTAX INTEGER { two-wires (1), four-wires (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates which voice path is provided by the E&M interface. Options: two-wires (1) four-wires (2)" --#STARTING-VERSION 11 ::= { cxMcVoxEmOpeEntry 26 } -- .......................................................................... -- cxMcVox OPERATIONAL FXS DRIVER GROUP cxMcVoxFxsOpeTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxFxsOpeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "cx Voice Station active FXS Table." ::= { cxMcVoxDriverOpe 2 } cxMcVoxFxsOpeEntry OBJECT-TYPE SYNTAX CxMcVoxFxsOpeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "cx Voice Station active FXS Entry " INDEX { cxMcVoxFxsOpeCardUsed, cxMcVoxFxsOpePortUsed } ::= { cxMcVoxFxsOpeTable 1 } CxMcVoxFxsOpeEntry ::= SEQUENCE { cxMcVoxFxsOpeCardUsed INTEGER, cxMcVoxFxsOpePortUsed INTEGER, cxMcVoxFxsOpePortStatus INTEGER, cxMcVoxFxsOpeVocoder INTEGER, cxMcVoxFxsOpeFaxBw INTEGER, cxMcVoxFxsOpeAutoCnx INTEGER, cxMcVoxFxsOpePathId DisplayString, cxMcVoxFxsOpeTxGain INTEGER, cxMcVoxFxsOpeRxGain INTEGER, cxMcVoxFxsOpeEchoCancel INTEGER, cxMcVoxFxsOpeSignaling INTEGER, cxMcVoxFxsOpeTimeOn INTEGER, cxMcVoxFxsOpeTimeOff INTEGER, cxMcVoxFxsOpeCnctType INTEGER, cxMcVoxFxsOpeRingType INTEGER, cxMcVoxFxsOpeImpedance INTEGER, cxMcVoxFxsOpeDialType INTEGER, cxMcVoxFxsOpeDidSignalType INTEGER, cxMcVoxFxsOpeRmtExt DisplayString, cxMcVoxFxsOpeRmtId DisplayString, cxMcVoxFxsOpeTranspMode INTEGER, cxMcVoxFxsOpeFaxEnable INTEGER, cxMcVoxFxsOpeBroadcast INTEGER } -- USER MODE OBJECTS: cxMcVoxFxsOpeCardUsed OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default: none" ::= { cxMcVoxFxsOpeEntry 1 } cxMcVoxFxsOpePortUsed OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the number of the voice I/O port. You cannot modify this object Options: CX900: 1 is the only acceptable value. Each I/O card has only 1 port. CX1000: up to 15 for the DI600 Default: none" ::= { cxMcVoxFxsOpeEntry 2 } cxMcVoxFxsOpePortStatus OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), no-voice-io (3), boot-err-1 (31), boot-err-2 (32), boot-err-3 (33), boot-err-4 (34), appl-err-1 (41), appl-err-2 (42), appl-err-3 (43), appl-err-4 (44) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the functional status of the operative port. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmportStatus of the cxMcVox Administrative FXS Driver Group. Options: disable (1): port is not functional enabled (2): port is up and active no-voice-io (3): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-1 (31): = Memotec use only. Contact Memotec service personnel if this value displays. boot-err-2 (32): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-3 (33): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-4 (34): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-1 (41): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-2 (42): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-3 (43): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-4 (44): Memotec use only. Contact Memotec service personnel if this value displays. Default Value: disable (1)" DEFVAL { disable } ::= { cxMcVoxFxsOpeEntry 3 } cxMcVoxFxsOpeVocoder OBJECT-TYPE SYNTAX INTEGER { bps5800 (1), bps8000 (2), kbps40 (3), kbps32 (4), kbps24 (5), kbps16 (6), opt7 (7), opt8 (8) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the transmission speed (in bits per second) of the compressed voice stream on the operative FXS port. Defining the speed also sets the ACELP voice compression ratio. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmVocoder of the cxMcVox Administrative FXS Driver Group. Options: bps5800 (1): compresses at a higher rate and uses slightly less bandwidth. bps8000 (2): compresses at approximately an 8:1 ratio (lower rate) with a higher quality voice sound at the receiving end. opt3 (3): ADPCM 40. opt4 (4): ADPCM 32. opt5 (5): ADPCM 24. opt6 (6): ADPCM 16. opt7 (7): Memotec use only. opt8 (8): Memotec use only. Default Value: bps8000 (2)" DEFVAL { bps8000 } ::= { cxMcVoxFxsOpeEntry 4 } cxMcVoxFxsOpeFaxBw OBJECT-TYPE SYNTAX INTEGER { bps2400 (1), bps4800 (2), bps7200 (3), bps9600 (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the speed (in bits per second) of the FAX channel on the operative FXS port. This value also determines the bandwidth required to pass FAX traffic through the voice software. This value can be set to match the speed of your FAX machine or it can be lowered to reduce bandwidth allocation. Options: bps2400 (1) bps4800 (2) bps7200 (3) bps9600 (4) Default Value: bps7200 (3) Configuration Changed: operative" DEFVAL { bps7200 } ::= { cxMcVoxFxsOpeEntry 5 } -- obsoleted (has been redefined) cxMcVoxFxsOpeAutoCnx OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-only STATUS obsolete DESCRIPTION "Obsolete" DEFVAL { no } ::= { cxMcVoxFxsOpeEntry 6 } cxMcVoxFxsOpePathId OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only STATUS deprecated DESCRIPTION "Path IDs no longer exist in the new Voice Routing (VR) scheme. The PathID was formerly used for auto-connection on the operative FXS port. The Path ID is a numeric dialing code the user enters to gain access to the remote telephone or fax machine. Note: The number of digits in the Path ID must match the value of the object cxMcVoxPathOpePathLng of the cxMcVox Operative Path Group. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmPathId of the cxMcVox Administrative FXS Driver Group. Range of Values: 1 to 4 numeric digits Default Value: none " --#ENDING-VERSION 1 ::= { cxMcVoxFxsOpeEntry 7 } cxMcVoxFxsOpeTxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the value defining the sound intensity (loudness) of voice transmissions on the operative FXS port. The transmission gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Transmission gains should be modified during a connection (i.e. dynamically) as changes in the value affect the local listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: operative" DEFVAL { 960 } ::= { cxMcVoxFxsOpeEntry 8 } cxMcVoxFxsOpeRxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the value defining the sound intensity (loudness) of voice reception on the operative FXS port. The reception gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Reception gains should be modified during a connection (i.e. dynamically) as changes in the value affect the remote listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: operative" DEFVAL { 960 } ::= { cxMcVoxFxsOpeEntry 9 } cxMcVoxFxsOpeEchoCancel OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the state of echo cancellation on the operative FXS port. When set to 'enable' at both the local and remote ends, echo cancellation stops echoes from the remote that are heard through the receiver at the local end. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmEchoCancel of the cxMcVox Administrative FXS Driver Group. Options: disable (1) enable (2) Default Value: enable (2)" DEFVAL { enable } ::= { cxMcVoxFxsOpeEntry 10 } cxMcVoxFxsOpeSignaling OBJECT-TYPE SYNTAX INTEGER { ground-start (1), loop-start (2), did (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the type of signalling the operative FXS port uses to seize the line. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxfxsAdmSignaling of the cxMcVox Administrative FXS Driver Group. Options: ground-start (1) loop-start (2) did (3) Default Value: loop-start" DEFVAL { loop-start } ::= { cxMcVoxFxsOpeEntry 11 } -- obsoleted object (has been redefined) cxMcVoxFxsOpeTimeOn OBJECT-TYPE SYNTAX INTEGER (10..10000) ACCESS read-only STATUS obsolete DESCRIPTION "Obsolete" DEFVAL { 2000 } ::= { cxMcVoxFxsOpeEntry 12 } -- obsoleted object (has been redefined) cxMcVoxFxsOpeTimeOff OBJECT-TYPE SYNTAX INTEGER (10..10000) ACCESS read-only STATUS obsolete DESCRIPTION "Obsoleted" DEFVAL { 4000 } ::= { cxMcVoxFxsOpeEntry 13 } cxMcVoxFxsOpeCnctType OBJECT-TYPE SYNTAX INTEGER { switched (1), auto-connect (2), fixed (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the method the operative FXS port uses to make connections. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmCnctType of the cxMcVox Administrative FXS Driver Group. Options: switched (1): the port connects each call according to the dialing code the user enters. auto-connect (2): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Any remote can connect to a port with an auto-connect configuration but when the local user initiates the call it always goes to the same remote. fixed (3): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Only the local and remote destinations of the connection can use this port. No other remote location can gain access to this port. Default Value: switched (1)" DEFVAL { switched } ::= { cxMcVoxFxsOpeEntry 14 } cxMcVoxFxsOpeRingType OBJECT-TYPE SYNTAX INTEGER { north-american (1), international (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the ring type of the operative FXS port. The ring types provide different ring timing to match the different ring cycles in networks. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmRingType of the cxMcVox Administrative FXS Driver Group. Options: north-american (1) international (2) Default Value: north-american (1)" DEFVAL { north-american } ::= { cxMcVoxFxsOpeEntry 15 } cxMcVoxFxsOpeImpedance OBJECT-TYPE SYNTAX INTEGER { i600-ohms (1), i900-ohms (2), att (3), aus (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Displays the input line impedance of the operative FXS interface. The value of this object can be modified in operational mode. Options: i600-ohms (1) i900-ohms (2) att (3) aus (4) Default Value: i600-ohms NOTE: The option aus(4) is added only starting at version 11. NOTE: This object is READ-ONLY for the CX800." DEFVAL { i600-ohms } ::= { cxMcVoxFxsOpeEntry 16 } cxMcVoxFxsOpeDialType OBJECT-TYPE SYNTAX INTEGER { dtmf (1), pulse (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the dialing method of the operative FXS port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing code. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmDialType of the cxMcVox Administrative FXS Driver Group table. Options: dtmf (1): (Dual Tone Multifrequence) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -7 plus or minus 3 dBm for the lower frequency groups and -5 plus or minus 3 dBm for the higher frequency group. The power level of the higher frequency tone is intentionally increased to compensate for the higher line loss. pulse (2): uses bursts (10 plus or minus 0.5 pps) of the main tone frequency (2280Hz) to generate the codes the user enters. Tones are generated at a level of -4 to -30 dBm for the 2280Hz frequency. The number of pulses during one second indicates the code the user dials. With the E&M interface, the voice station generates and detects pulses. Default Value: dtmf (1)" ::= { cxMcVoxFxsOpeEntry 17 } cxMcVoxFxsOpeDidSignalType OBJECT-TYPE SYNTAX INTEGER { normal (1), delay (2), wink (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the type of signaling on the operative FXS port. The signaling type refers to the line seizure technique. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmDidSignalType of the cxMcVox Administrative FXS Driver Group table. Options normal (1) delay (2) wink (3) Default Value: normal (1)" ::= { cxMcVoxFxsOpeEntry 18 } cxMcVoxFxsOpeRmtExt OBJECT-TYPE SYNTAX DisplayString (SIZE (1..5)) ACCESS read-only STATUS mandatory DESCRIPTION "Determines the Remote Extension or Group Id used for auto-connection on the FXS port. The Remote Extension is a numeric dialing code that the user enters to gain access to the remote telephone or fax machine. Auto-connection is the connection method that this port uses. A particular Remote Extension or Group Id has been assigned to the port so that no dialing is required. Note: The number of digits in the Remote Extension is determined by the object cxMcVoxNetNbDigits of the cxMcVox Global Parameters Group. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: operative" --#STARTING-VERSION 1 ::= { cxMcVoxFxsOpeEntry 19 } cxMcVoxFxsOpeRmtId OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only STATUS optional DESCRIPTION "Displays the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection via the fixed connection method. With the fixed connection method, a particular Remote Extension or Group Id is assigned to the port so that no dialing is required. The call to the remote is established as soon as the connection is configured. You cannot modify this object. If you want to change the ID you must modify the object cxMcVoxFxsAdmRmtId (of this table). Range of Values: a maximum of 10 alphanumeric characters in upper-case only. You can use any combination of letters and numbers; however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none" --#STARTING-VERSION 1 ::= { cxMcVoxFxsOpeEntry 20 } cxMcVoxFxsOpeTranspMode OBJECT-TYPE SYNTAX INTEGER { emulate (1), transparent (2) , local (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Determines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party has answered to the party to which the call is finally destinated. The Transparent mode is incompatible with Switched type of connection and is automatically disabled when Switched mode is selected (only applies to autoconnect and fixed connections). The Local mode lets the local port answer right away to a seizure. Options: emulate (1): Emulation mode is on transparent (2): Transparent mode on local (3): Local mode on Default Value: emulate (1) Configuration Changed: operational" DEFVAL { emulate } --#STARTING-VERSION 3 ::= { cxMcVoxFxsOpeEntry 21 } cxMcVoxFxsOpeFaxEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the state of the FAX on the operative FXS port. When set to 'enable' at both the local and remote ends, the FAX will be enabled. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxsAdmFaxEnable of the cxMcVox Administrative FXS Driver Group. Options: disable (1) enable (2) Default Value: enable (2)" DEFVAL { enable } --#STARTING-VERSION 8 ::= { cxMcVoxFxsOpeEntry 22 } cxMcVoxFxsOpeBroadcast OBJECT-TYPE SYNTAX INTEGER { none (1), master (2) , slave (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Cetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Default Value: none (1)" DEFVAL { none } --#STARTING-VERSION 10 ::= { cxMcVoxFxsOpeEntry 23 } -- .......................................................................... -- cxMcVox OPERATIONAL FXO DRIVER GROUP cxMcVoxFxoOpeTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxFxoOpeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "cx Voice Station active FXO Table." ::= { cxMcVoxDriverOpe 3 } cxMcVoxFxoOpeEntry OBJECT-TYPE SYNTAX CxMcVoxFxoOpeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "cx Voice Station active FXO Entry " INDEX { cxMcVoxFxoOpeCardUsed, cxMcVoxFxoOpePortUsed } ::= { cxMcVoxFxoOpeTable 1 } CxMcVoxFxoOpeEntry ::= SEQUENCE { cxMcVoxFxoOpeCardUsed INTEGER, cxMcVoxFxoOpePortUsed INTEGER, cxMcVoxFxoOpePortStatus INTEGER, cxMcVoxFxoOpeVocoder INTEGER, cxMcVoxFxoOpeFaxBw INTEGER, cxMcVoxFxoOpeAutoCnx INTEGER, cxMcVoxFxoOpePathId DisplayString, cxMcVoxFxoOpeTxGain INTEGER, cxMcVoxFxoOpeRxGain INTEGER, cxMcVoxFxoOpeEchoCancel INTEGER, cxMcVoxFxoOpeSignaling INTEGER, cxMcVoxFxoOpeCnctType INTEGER, cxMcVoxFxoOpeRingType INTEGER, cxMcVoxFxoOpeImpedance INTEGER, cxMcVoxFxoOpeDialType INTEGER, cxMcVoxFxoOpeDidSignalType INTEGER, cxMcVoxFxoOpeRmtExt DisplayString, cxMcVoxFxoOpeRmtId DisplayString, cxMcVoxFxoOpeTranspMode INTEGER, cxMcVoxFxoOpeFaxEnable INTEGER, cxMcVoxFxoOpeBroadcast INTEGER } -- USER MODE OBJECTS: cxMcVoxFxoOpeCardUsed OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000 1 to 8 Default: none" ::= { cxMcVoxFxoOpeEntry 1 } cxMcVoxFxoOpePortUsed OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the number of the voice I/O port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card has only 1 port. CX1000: up to 15 for the DI600 Default: none" ::= { cxMcVoxFxoOpeEntry 2 } cxMcVoxFxoOpePortStatus OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), no-voice-io (3), boot-err-1 (31), boot-err-2 (32), boot-err-3 (33), boot-err-4 (34), appl-err-1 (41), appl-err-2 (42), appl-err-3 (43), appl-err-4 (44) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the functional status of the port. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmportStatus of the cxMcVox Administrative FXO Driver Group. Options: disable (1): port is not functional enable (2): port is up and active no-voice-io (3): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-1 (31): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-2 (32): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-3 (33): Memotec use only. Contact Memotec service personnel if this value displays. boot-err-4 (34): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-1 (41): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-2 (42): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-3 (43): Memotec use only. Contact Memotec service personnel if this value displays. appl-err-4 (44): Memotec use only. Contact Memotec service personnel if this value displays. Default Value: disable (1)" DEFVAL { disable } ::= { cxMcVoxFxoOpeEntry 3 } cxMcVoxFxoOpeVocoder OBJECT-TYPE SYNTAX INTEGER { bps5800 (1), bps8000 (2), kbps40 (3), kbps32 (4), kbps24 (5), kbps16 (6), opt7 (7), opt8 (8) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the transmission speed (in bits per second) of the compressed voice stream on the operative FXO port. Defining the speed also sets the ACELP voice compression ratio. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmVocoder of the cxMcVox Administrative FXO Driver Group. Options: bps5800 (1): compresses at a higher rate and uses slightly less bandwidth. bps8000 (2): compresses at approximately an 8:1 ratio (lower rate) with a higher quality voice sound at the receiving end. opt3 (3): ADPCM 40. opt4 (4): ADPCM 32. opt5 (5): ADPCM 24. opt6 (6): ADPCM 16. opt7 (7): Memotec use only. opt8 (8): Memotec use only. Default Value: bps8000 (2)" DEFVAL { bps8000 } ::= { cxMcVoxFxoOpeEntry 4 } cxMcVoxFxoOpeFaxBw OBJECT-TYPE SYNTAX INTEGER { bps2400 (1), bps4800 (2), bps7200 (3), bps9600 (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the speed (in bits per second) of the FAX channel on the operative FXO port. This value also determines the bandwidth required to pass FAX traffic through the voice software. This value can be set to match the speed of your FAX machine or it can be lowered to reduce bandwidth allocation. Options: bps2400 (1) bps4800 (2) bps7200 (3) bps9600 (4) Default Value: bps7200 (3) Configuration Changed: operative" DEFVAL { bps7200 } ::= { cxMcVoxFxoOpeEntry 5 } -- obsoleted (has been redefined) cxMcVoxFxoOpeAutoCnx OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-only STATUS obsolete DESCRIPTION "Obsolete" DEFVAL { no } ::= { cxMcVoxFxoOpeEntry 6 } cxMcVoxFxoOpePathId OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only STATUS deprecated DESCRIPTION "Path IDs no longer exist in the new Voice Routing (VR) scheme. The PathID was formerly used for auto-connection on the operative FXO port. The Path ID is a numeric dialing code that the user enters to gain access to the remote telephone or fax machine. Note: The number of digits in the Path ID must match the value of the object cxMcVoxPathOpePathLng of the cxMcVox Operative Path Group. You cannot modify this object. If you want to change the value you modify the object cxMcVoxFxoAdmPathId of the cxMcVox Administrative FXO Driver Group. Range of Values: 1 to 4 digits Default Value: none" --#ENDING-VERSION 1 ::= { cxMcVoxFxoOpeEntry 7 } cxMcVoxFxoOpeTxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the value defining the sound intensity (loudness) of voice transmissions on the operative FXO port. The transmission gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Transmission gains should be modified during a connection (i.e. dynamically) as changes in the value affect the local listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: operative" DEFVAL { 960 } ::= { cxMcVoxFxoOpeEntry 8 } cxMcVoxFxoOpeRxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the value defining the sound intensity (loudness) of voice reception on the operative FXO port. The reception gain can be modified in the administrative configuration or be fine-tuned dynamically. Note: Reception gains should be modified during a connection (i.e. dynamically) as changes in the value affect the remote listener. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 960 Configuration Changed: operative" DEFVAL { 960 } ::= { cxMcVoxFxoOpeEntry 9 } cxMcVoxFxoOpeEchoCancel OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the state of echo cancellation on the operative FXO port. When set to 'enable' at both the local and remote ends, echo cancellation stops echoes from the remote that are heard through the receiver at the local end. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmEchoCancel of the cxMcVox Administrative FXO Driver Group. Options: disable (1) enable (2) Default Value: enable (2)" DEFVAL { enable } ::= { cxMcVoxFxoOpeEntry 10 } cxMcVoxFxoOpeSignaling OBJECT-TYPE SYNTAX INTEGER { ground-start (1), loop-start (2), did (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the type of signalling the operative FXO port uses to seize the line. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmSignaling of the cxMcVox Administrative FXO Driver Group. Options: ground-start (1) loop-start (2) did (3) Default Value: loop-start" DEFVAL { loop-start } ::= { cxMcVoxFxoOpeEntry 11 } cxMcVoxFxoOpeCnctType OBJECT-TYPE SYNTAX INTEGER { switched (1), auto-connect (2), fixed (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the method the operative FXO port uses to make connections. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmCnctType of the cxMcVox Administrative FXO Driver Group. Options: switched (1): the port connects each call according to the dialing code the user enters. auto-connect (2): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Any remote can connect to a port with an auto-connect configuration but when the local user initiates the call it always goes to the same remote. fixed (3): calls passing through this port always terminate at the same remote destination. The port connects to the remote as soon as the local receiver enters the off-hook state. Only the local and remote destinations of the connection can use this port. No other remote location can gain access to this port. Default Value: switched (1)" DEFVAL { switched } ::= { cxMcVoxFxoOpeEntry 12 } cxMcVoxFxoOpeRingType OBJECT-TYPE SYNTAX INTEGER { north-american (1), international (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the ring type of the operative FXO port. The ring types provide different ring timing to match the different ring cycles in networks. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmRingType of the cxMcVox Administrative FXO Driver Group. Options: north-american (1) international (2) Default Value: north-american (1)" DEFVAL { north-american } ::= { cxMcVoxFxoOpeEntry 13 } cxMcVoxFxoOpeImpedance OBJECT-TYPE SYNTAX INTEGER { i600-ohms (1), i900-ohms (2), att (3), aus (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Displays the input line impedance of the operative FXO interface. The value of this object can be modified in operational mode. Options: i600-ohms (1) i900-ohms (2) att (3) aus (4) Default Value: i600-ohms (1) NOTE: The option aus(4) is added only starting at version 11. NOTE: This object is READ-ONLY for the CX800." DEFVAL { i600-ohms } ::= { cxMcVoxFxoOpeEntry 14 } cxMcVoxFxoOpeDialType OBJECT-TYPE SYNTAX INTEGER { dtmf (1), pulse (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the dialing method of the operative FXO port. The dialing method refers to the sound that occurs when the user enters each digit of the dialing code. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmDialType of the cxMcVox Administrative FXO Driver Group table. Options: dtmf (1): (Dual Tone Multifrequence) uses bursts of frequency pairs to identify the code the user dials. Tones are generated at a level of -7 plus or minus 3 dBm for the lower frequency groups and -5 plus or minus 3 dBm for the higher frequency group. The power level of the higher frequency tone is intentionally increased to compensate for the higher line loss. pulse (2): uses bursts (10 plus or minus 0.5 pps) of the main tone frequency (2280Hz) to generate the codes the user enters. Tones are generated at a level of -4 to -30 dBm for the 2280Hz frequency. The number of pulses during one second indicates the code the user dials. With the E&M interface, the voice station generates and detects pulses. Default Value: dtmf (1)" ::= { cxMcVoxFxoOpeEntry 15 } cxMcVoxFxoOpeDidSignalType OBJECT-TYPE SYNTAX INTEGER { normal (1), delay (2), wink (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the type of signaling on the operative FXO port. The signaling type refers to the line seizure technique. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmDidSignalType of the cxMcVox Administrative FXO Driver Group table. Options normal (1) delay (2) wink (3) Default Value: normal (1)" ::= { cxMcVoxFxoOpeEntry 16 } cxMcVoxFxoOpeRmtExt OBJECT-TYPE SYNTAX DisplayString (SIZE (1..5)) ACCESS read-only STATUS mandatory DESCRIPTION "Determines the Remote Extension or Group Id used for auto-connection on the FXO port. The Remote Extension is a numeric dialing code that the user enters to gain access to the remote telephone or fax machine. Auto-connection is the connection method that this port uses. A particular Remote Extension or Group Id has been assigned to the port so that no dialing is required. Note: The number of digits in the Remote Extension is determined by the object cxMcVoxNetNbDigits of the cxMcVox Global Parameters Group. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: operative" --#STARTING-VERSION 1 ::= { cxMcVoxFxoOpeEntry 17 } cxMcVoxFxoOpeRmtId OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only STATUS optional DESCRIPTION "Displays the ID (name) for the remote voice station. Note: This object must be defined in order to obtain a successful voice connection via the fixed connection method. With the fixed connection method, a particular Remote Extension or Group Id is assigned to the port so that no dialing is required. The call to the remote is established as soon as the connection is configured. You cannot modify this object. If you want to change the ID you must modify the object cxMcVoxFxoAdmRmtId (of this table). Range of Values: a maximum of 10 alphanumeric characters in upper-case only. You can use any combination of letters and numbers; however you cannot use blank spaces. Use a dash or underscore as a delimiter. Default Value: none" --#STARTING-VERSION 1 ::= { cxMcVoxFxoOpeEntry 18 } cxMcVoxFxoOpeTranspMode OBJECT-TYPE SYNTAX INTEGER { emulate (1), transparent (2) , local (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Determines the whether to use the Transparent mode on the administrative port. In the transparent mode, the local port will answer only after the called party has answered to the party to which the call is finally destinated. The Transparent mode is incompatible with Switched type of connection and is automatically disabled when Switched mode is selected (only applies to autoconnect and fixed connections). The Local mode lets the local port answer right away to a seizure. Options: emulate (1): Emulation mode is on transparent (2): Transparent mode on local (3): Local mode on Default Value: emulate (1) Configuration Changed: operational" DEFVAL { emulate } --#STARTING-VERSION 3 ::= { cxMcVoxFxoOpeEntry 19 } cxMcVoxFxoOpeFaxEnable OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the state of the FAX on the operative FXO port. When set to 'enable' at both the local and remote ends, the FAX will be enabled. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmFaxEnable of the cxMcVox Administrative FXO Driver Group. Options: disable (1) enable (2) Default Value: enable (2)" DEFVAL { enable } --#STARTING-VERSION 8 ::= { cxMcVoxFxoOpeEntry 20 } cxMcVoxFxoOpeBroadcast OBJECT-TYPE SYNTAX INTEGER { none (1), master (2) , slave (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Cetermines the state of the voice broadcast feature. When set to none, no broadcast is used. When set to master, ... Options: none (1) master (2) slave (3) Default Value: none (1)" DEFVAL { none } --#STARTING-VERSION 10 ::= { cxMcVoxFxoOpeEntry 21 } -- ============================================================ cxMcVoxDriverAdmPriv OBJECT IDENTIFIER ::= {cxMcVox 20 } -- cxMcVox ADMINISTRATIVE PORTS PRIVATE GROUP -- (!!! new group) cxMcVoxAdmPortPrivTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxAdmPortPrivEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Voice station planned Table." ::= { cxMcVoxDriverAdmPriv 1 } cxMcVoxAdmPortPrivEntry OBJECT-TYPE SYNTAX CxMcVoxAdmPortPrivEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Voice station planned row definition." INDEX { cxMcVoxAdmCardUsed, cxMcVoxAdmPortUsed } ::= { cxMcVoxAdmPortPrivTable 1 } CxMcVoxAdmPortPrivEntry ::= SEQUENCE { cxMcVoxAdmCardUsed INTEGER, cxMcVoxAdmPortUsed INTEGER, cxMcVoxAdmRingTimeOn INTEGER, cxMcVoxAdmRingTimeOff1 INTEGER, cxMcVoxAdmRingTimeOff2 INTEGER, cxMcVoxAdmEchoCancelLevel INTEGER, cxMcVoxAdmToneDelayAfterCnct INTEGER, cxMcVoxAdmToneDelayAfterFlash INTEGER, cxMcVoxAdmToneOffsetTxGain INTEGER, cxMcVoxAdmVoiceOffsetTxGain INTEGER, cxMcVoxAdmAc15InterDigit INTEGER, cxMcVoxAdmMfToneThold INTEGER, cxMcVoxAdmPulseTmin INTEGER, cxMcVoxAdmPulseTmax INTEGER, cxMcVoxAdmPulseInterDigit INTEGER, cxMcVoxAdmDtmfGuard INTEGER, cxMcVoxAdmDtmfOpeLevel INTEGER, cxMcVoxAdmDtmfTxTimeOn INTEGER, cxMcVoxAdmDtmfTxTimeOff INTEGER, cxMcVoxAdmFlashTmin INTEGER, cxMcVoxAdmFlashTmax INTEGER, cxMcVoxAdmFlashTgen INTEGER, cxMcVoxAdmAfterToneSilences INTEGER, cxMcVoxAdmFaxTxGain INTEGER, cxMcVoxAdmFaxRxGain INTEGER, cxMcVoxAdmFaxHdlcFlags INTEGER, cxMcVoxAdmFaxPreambleDuration INTEGER, cxMcVoxAdmFaxPreambleDelay INTEGER, cxMcVoxAdmFaxCedToneDuration INTEGER, cxMcVoxAdmFaxInterProtoGap INTEGER, cxMcVoxAdmFaxTimerDetectSync INTEGER, cxMcVoxAdmFaxTimerWaitId INTEGER, cxMcVoxAdmFaxMinPreambleDur INTEGER, cxMcVoxAdmFaxMaxPreambleDur INTEGER, cxMcVoxAdmFaxMinPreambleDly INTEGER, cxMcVoxAdmFaxMaxPreambleDly INTEGER, cxMcVoxAdmFaxCedToneDetection INTEGER, cxMcVoxAdmFaxCedMinToneDur INTEGER, cxMcVoxAdmFaxCedMaxToneDur INTEGER, cxMcVoxAdmFaxMaxHdlcFlags INTEGER } cxMcVoxAdmCardUsed OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the slot number of the voice I/O card. You cannot modify this object Range of Values: CX900: 1 to 6 CX1000: 1 to 4 Default: none" ::= { cxMcVoxAdmPortPrivEntry 1 } cxMcVoxAdmPortUsed OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the number of the voice I/O port. You cannot modify this object. It is a display that the software provides. Options: CX900: 1 is the only acceptable value. Each I/O card has only 1 port. CX1000: up to 15 for the DI600 Default: none" ::= { cxMcVoxAdmPortPrivEntry 2 } cxMcVoxAdmRingTimeOn OBJECT-TYPE SYNTAX INTEGER (10..10000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 2000" DEFVAL { 2000 } ::= { cxMcVoxAdmPortPrivEntry 3 } cxMcVoxAdmRingTimeOff1 OBJECT-TYPE SYNTAX INTEGER (10..10000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 4000" DEFVAL { 4000 } ::= { cxMcVoxAdmPortPrivEntry 4 } cxMcVoxAdmRingTimeOff2 OBJECT-TYPE SYNTAX INTEGER (10..10000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 2000" DEFVAL { 2000 } ::= { cxMcVoxAdmPortPrivEntry 5 } cxMcVoxAdmEchoCancelLevel OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65535 Default Value: 100" DEFVAL { 100 } ::= { cxMcVoxAdmPortPrivEntry 6 } cxMcVoxAdmToneDelayAfterCnct OBJECT-TYPE SYNTAX INTEGER (0..6000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 6000 Default Value: 1000" DEFVAL { 1000 } ::= { cxMcVoxAdmPortPrivEntry 7 } cxMcVoxAdmToneDelayAfterFlash OBJECT-TYPE SYNTAX INTEGER (0..6000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 6000 Default Value: 400" DEFVAL { 400 } ::= { cxMcVoxAdmPortPrivEntry 8 } cxMcVoxAdmToneOffsetTxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000" DEFVAL { 1000 } ::= { cxMcVoxAdmPortPrivEntry 9 } cxMcVoxAdmVoiceOffsetTxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000" DEFVAL { 1000 } ::= { cxMcVoxAdmPortPrivEntry 10 } cxMcVoxAdmAc15InterDigit OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 800" DEFVAL { 800 } ::= { cxMcVoxAdmPortPrivEntry 11 } cxMcVoxAdmMfToneThold OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 255 Default Value: 60" DEFVAL { 60 } ::= { cxMcVoxAdmPortPrivEntry 12 } cxMcVoxAdmPulseTmin OBJECT-TYPE SYNTAX INTEGER (0..3000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 15" DEFVAL { 15 } ::= { cxMcVoxAdmPortPrivEntry 13 } cxMcVoxAdmPulseTmax OBJECT-TYPE SYNTAX INTEGER (0..3000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 125" DEFVAL { 125 } ::= { cxMcVoxAdmPortPrivEntry 14 } cxMcVoxAdmPulseInterDigit OBJECT-TYPE SYNTAX INTEGER (0..3000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 275" DEFVAL { 275 } ::= { cxMcVoxAdmPortPrivEntry 15 } cxMcVoxAdmDtmfGuard OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 255 Default Value: 40" DEFVAL { 40 } ::= { cxMcVoxAdmPortPrivEntry 16 } cxMcVoxAdmDtmfOpeLevel OBJECT-TYPE SYNTAX INTEGER { minus-25 (1), minus-28 (2), minus-31 (3), minus-34 (4) } ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Options: minus-25 (1) minus-28 (2) minus-31 (3) minus-34 (4) Default Value: minus-25 (1)" DEFVAL { minus-25 } ::= { cxMcVoxAdmPortPrivEntry 17 } cxMcVoxAdmDtmfTxTimeOn OBJECT-TYPE SYNTAX INTEGER (0..500) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 500 Default Value: 75" DEFVAL { 75 } ::= { cxMcVoxAdmPortPrivEntry 18 } cxMcVoxAdmDtmfTxTimeOff OBJECT-TYPE SYNTAX INTEGER (0..500) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 500 Default Value: 75" DEFVAL { 75 } ::= { cxMcVoxAdmPortPrivEntry 19 } cxMcVoxAdmFlashTmin OBJECT-TYPE SYNTAX INTEGER (50..10000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 200" DEFVAL { 200 } ::= { cxMcVoxAdmPortPrivEntry 20 } cxMcVoxAdmFlashTmax OBJECT-TYPE SYNTAX INTEGER (50..10000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 800" DEFVAL { 800 } ::= { cxMcVoxAdmPortPrivEntry 21 } cxMcVoxAdmFlashTgen OBJECT-TYPE SYNTAX INTEGER (50..10000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 500" DEFVAL { 500 } ::= { cxMcVoxAdmPortPrivEntry 22 } cxMcVoxAdmAfterToneSilences OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 127 Default Value: 64" DEFVAL { 64 } ::= { cxMcVoxAdmPortPrivEntry 23 } cxMcVoxAdmFaxTxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000" DEFVAL { 1000 } ::= { cxMcVoxAdmPortPrivEntry 24 } cxMcVoxAdmFaxRxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000" DEFVAL { 1000 } ::= { cxMcVoxAdmPortPrivEntry 25 } cxMcVoxAdmFaxHdlcFlags OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 127 Default Value: 2" DEFVAL { 2 } ::= { cxMcVoxAdmPortPrivEntry 26 } cxMcVoxAdmFaxPreambleDuration OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS deprecated DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1000" DEFVAL { 1000 } --#ENDING-VERSION 1 ::= { cxMcVoxAdmPortPrivEntry 27 } cxMcVoxAdmFaxPreambleDelay OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS deprecated DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 900" DEFVAL { 900 } --#ENDING-VERSION 1 ::= { cxMcVoxAdmPortPrivEntry 28 } cxMcVoxAdmFaxCedToneDuration OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS deprecated DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 500" DEFVAL { 500 } --#ENDING-VERSION 1 ::= { cxMcVoxAdmPortPrivEntry 29 } cxMcVoxAdmFaxInterProtoGap OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 75" DEFVAL { 75 } ::= { cxMcVoxAdmPortPrivEntry 30 } cxMcVoxAdmFaxTimerDetectSync OBJECT-TYPE SYNTAX INTEGER (0..65000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65000 Default Value: 7500" DEFVAL { 7500 } ::= { cxMcVoxAdmPortPrivEntry 31 } cxMcVoxAdmFaxTimerWaitId OBJECT-TYPE SYNTAX INTEGER (0..65000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65000 Default Value: 40000" DEFVAL { 40000 } ::= { cxMcVoxAdmPortPrivEntry 32 } cxMcVoxAdmFaxMinPreambleDur OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1000" DEFVAL { 1000 } --#STARTING-VERSION 2 ::= { cxMcVoxAdmPortPrivEntry 33 } cxMcVoxAdmFaxMaxPreambleDur OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1200" DEFVAL { 1200 } --#STARTING-VERSION 2 ::= { cxMcVoxAdmPortPrivEntry 34 } cxMcVoxAdmFaxMinPreambleDly OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 400" DEFVAL { 400 } --#STARTING-VERSION 2 ::= { cxMcVoxAdmPortPrivEntry 35 } cxMcVoxAdmFaxMaxPreambleDly OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 900" DEFVAL { 900 } --#STARTING-VERSION 2 ::= { cxMcVoxAdmPortPrivEntry 36 } cxMcVoxAdmFaxCedToneDetection OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 500" DEFVAL { 500 } --#STARTING-VERSION 2 ::= { cxMcVoxAdmPortPrivEntry 37 } cxMcVoxAdmFaxCedMinToneDur OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 2600" DEFVAL { 2600 } --#STARTING-VERSION 2 ::= { cxMcVoxAdmPortPrivEntry 38 } cxMcVoxAdmFaxCedMaxToneDur OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 4000" DEFVAL { 4000 } --#STARTING-VERSION 2 ::= { cxMcVoxAdmPortPrivEntry 39 } cxMcVoxAdmFaxMaxHdlcFlags OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 127 Default Value: 32" DEFVAL { 32 } --#STARTING-VERSION 3 ::= { cxMcVoxAdmPortPrivEntry 40 } -- ============================================================ cxMcVoxDriverOpePriv OBJECT IDENTIFIER ::= {cxMcVox 21 } -- cxMcVox OPERATIONAL PORTS PRIVATE GROUP -- (!!! new group) cxMcVoxOpePortPrivTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxOpePortPrivEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Voice station planned Table." ::= { cxMcVoxDriverOpePriv 1 } cxMcVoxOpePortPrivEntry OBJECT-TYPE SYNTAX CxMcVoxOpePortPrivEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Voice station planned row definition." INDEX { cxMcVoxOpeCardUsed, cxMcVoxOpePortUsed } ::= { cxMcVoxOpePortPrivTable 1 } CxMcVoxOpePortPrivEntry ::= SEQUENCE { cxMcVoxOpeCardUsed INTEGER, cxMcVoxOpePortUsed INTEGER, cxMcVoxOpeRingTimeOn INTEGER, cxMcVoxOpeRingTimeOff1 INTEGER, cxMcVoxOpeRingTimeOff2 INTEGER, cxMcVoxOpeEchoCancelLevel INTEGER, cxMcVoxOpeToneDelayAfterCnct INTEGER, cxMcVoxOpeToneDelayAfterFlash INTEGER, cxMcVoxOpeToneOffsetTxGain INTEGER, cxMcVoxOpeVoiceOffsetTxGain INTEGER, cxMcVoxOpeAc15InterDigit INTEGER, cxMcVoxOpeMfToneThold INTEGER, cxMcVoxOpePulseTmin INTEGER, cxMcVoxOpePulseTmax INTEGER, cxMcVoxOpePulseInterDigit INTEGER, cxMcVoxOpeDtmfGuard INTEGER, cxMcVoxOpeDtmfOpeLevel INTEGER, cxMcVoxOpeDtmfTxTimeOn INTEGER, cxMcVoxOpeDtmfTxTimeOff INTEGER, cxMcVoxOpeFlashTmin INTEGER, cxMcVoxOpeFlashTmax INTEGER, cxMcVoxOpeFlashTgen INTEGER, cxMcVoxOpeAfterToneSilences INTEGER, cxMcVoxOpeFaxTxGain INTEGER, cxMcVoxOpeFaxRxGain INTEGER, cxMcVoxOpeFaxHdlcFlags INTEGER, cxMcVoxOpeFaxPreambleDuration INTEGER, cxMcVoxOpeFaxPreambleDelay INTEGER, cxMcVoxOpeFaxCedToneDuration INTEGER, cxMcVoxOpeFaxInterProtoGap INTEGER, cxMcVoxOpeFaxTimerDetectSync INTEGER, cxMcVoxOpeFaxTimerWaitId INTEGER, cxMcVoxOpeFaxMinPreambleDur INTEGER, cxMcVoxOpeFaxMaxPreambleDur INTEGER, cxMcVoxOpeFaxMinPreambleDly INTEGER, cxMcVoxOpeFaxMaxPreambleDly INTEGER, cxMcVoxOpeFaxCedToneDetection INTEGER, cxMcVoxOpeFaxCedMinToneDur INTEGER, cxMcVoxOpeFaxCedMaxToneDur INTEGER, cxMcVoxOpeFaxMaxHdlcFlags INTEGER } cxMcVoxOpeCardUsed OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the slot number of the voice I/O card. You cannot modify this object. Range of Values: CX900: 1 to 6 CX1000: 1 to 8 Default: none" ::= { cxMcVoxOpePortPrivEntry 1 } cxMcVoxOpePortUsed OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the number of the voice I/O port. You cannot modify this object. Options: CX900: 1 is the only acceptable value. Each I/O card has only 1 port. CX1000: up to 15 for the DI600 Default: none" ::= { cxMcVoxOpePortPrivEntry 2 } cxMcVoxOpeRingTimeOn OBJECT-TYPE SYNTAX INTEGER (10..10000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 2000" DEFVAL { 2000 } ::= { cxMcVoxOpePortPrivEntry 3 } cxMcVoxOpeRingTimeOff1 OBJECT-TYPE SYNTAX INTEGER (10..10000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 4000" DEFVAL { 4000 } ::= { cxMcVoxOpePortPrivEntry 4 } cxMcVoxOpeRingTimeOff2 OBJECT-TYPE SYNTAX INTEGER (10..10000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 10 to 10000 Default Value: 2000" DEFVAL { 2000 } ::= { cxMcVoxOpePortPrivEntry 5 } cxMcVoxOpeEchoCancelLevel OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65535 Default Value: 100" DEFVAL { 100 } ::= { cxMcVoxOpePortPrivEntry 6 } cxMcVoxOpeToneDelayAfterCnct OBJECT-TYPE SYNTAX INTEGER (0..6000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 6000 Default Value: 1000" DEFVAL { 1000 } ::= { cxMcVoxOpePortPrivEntry 7 } cxMcVoxOpeToneDelayAfterFlash OBJECT-TYPE SYNTAX INTEGER (0..6000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 6000 Default Value: 400" DEFVAL { 400 } ::= { cxMcVoxOpePortPrivEntry 8 } cxMcVoxOpeToneOffsetTxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000" DEFVAL { 1000 } ::= { cxMcVoxOpePortPrivEntry 9 } cxMcVoxOpeVoiceOffsetTxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000" DEFVAL { 1000 } ::= { cxMcVoxOpePortPrivEntry 10 } cxMcVoxOpeAc15InterDigit OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 800" DEFVAL { 800 } ::= { cxMcVoxOpePortPrivEntry 11 } cxMcVoxOpeMfToneThold OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 255 Default Value: 60" DEFVAL { 60 } ::= { cxMcVoxOpePortPrivEntry 12 } cxMcVoxOpePulseTmin OBJECT-TYPE SYNTAX INTEGER (0..3000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 15" DEFVAL { 15 } ::= { cxMcVoxOpePortPrivEntry 13 } cxMcVoxOpePulseTmax OBJECT-TYPE SYNTAX INTEGER (0..3000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 125" DEFVAL { 125 } ::= { cxMcVoxOpePortPrivEntry 14 } cxMcVoxOpePulseInterDigit OBJECT-TYPE SYNTAX INTEGER (0..3000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 3000 Default Value: 275" DEFVAL { 275 } ::= { cxMcVoxOpePortPrivEntry 15 } cxMcVoxOpeDtmfGuard OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 255 Default Value: 40" DEFVAL { 40 } ::= { cxMcVoxOpePortPrivEntry 16 } cxMcVoxOpeDtmfOpeLevel OBJECT-TYPE SYNTAX INTEGER { minus-25 (1), minus-28 (2), minus-31 (3), minus-34 (4) } ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Options: minus-25 (1) minus-28 (2) minus-31 (3) minus-34 (4) Default Value: minus-25 (1)" DEFVAL { minus-25 } ::= { cxMcVoxOpePortPrivEntry 17 } cxMcVoxOpeDtmfTxTimeOn OBJECT-TYPE SYNTAX INTEGER (0..500) ACCESS read-only STATUS mandatory DESCRIPTION "This object is read-only. Range of Values: 0 to 500" DEFVAL { 75 } ::= { cxMcVoxOpePortPrivEntry 18 } cxMcVoxOpeDtmfTxTimeOff OBJECT-TYPE SYNTAX INTEGER (0..500) ACCESS read-only STATUS mandatory DESCRIPTION "This object is read-only. Range of Values: 0 to 500" DEFVAL { 75 } ::= { cxMcVoxOpePortPrivEntry 19 } cxMcVoxOpeFlashTmin OBJECT-TYPE SYNTAX INTEGER (50..10000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 200" DEFVAL { 200 } ::= { cxMcVoxOpePortPrivEntry 20 } cxMcVoxOpeFlashTmax OBJECT-TYPE SYNTAX INTEGER (50..10000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 800" DEFVAL { 800 } ::= { cxMcVoxOpePortPrivEntry 21 } cxMcVoxOpeFlashTgen OBJECT-TYPE SYNTAX INTEGER (50..10000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 50 to 10000 Default Value: 500" DEFVAL { 500 } ::= { cxMcVoxOpePortPrivEntry 22 } cxMcVoxOpeAfterToneSilences OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "This object is read-only. Range of Values: 0 to 127" DEFVAL { 64 } ::= { cxMcVoxOpePortPrivEntry 23 } cxMcVoxOpeFaxTxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000" DEFVAL { 1000 } ::= { cxMcVoxOpePortPrivEntry 24 } cxMcVoxOpeFaxRxGain OBJECT-TYPE SYNTAX INTEGER (820..1180) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 820 to 1180 (-18.0dB to 18.0dB) Default Value: 1000" DEFVAL { 1000 } ::= { cxMcVoxOpePortPrivEntry 25 } cxMcVoxOpeFaxHdlcFlags OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 127 Default Value: 2" DEFVAL { 2 } ::= { cxMcVoxOpePortPrivEntry 26 } cxMcVoxOpeFaxPreambleDuration OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS deprecated DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1000" DEFVAL { 1000 } --#ENDING-VERSION 1 ::= { cxMcVoxOpePortPrivEntry 27 } cxMcVoxOpeFaxPreambleDelay OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS deprecated DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 900" DEFVAL { 900 } --#ENDING-VERSION 1 ::= { cxMcVoxOpePortPrivEntry 28 } cxMcVoxOpeFaxCedToneDuration OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS deprecated DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 500" DEFVAL { 500 } --#ENDING-VERSION 1 ::= { cxMcVoxOpePortPrivEntry 29 } cxMcVoxOpeFaxInterProtoGap OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 75" DEFVAL { 75 } ::= { cxMcVoxOpePortPrivEntry 30 } cxMcVoxOpeFaxTimerDetectSync OBJECT-TYPE SYNTAX INTEGER (0..65000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65000 Default Value: 7500" DEFVAL { 7500 } ::= { cxMcVoxOpePortPrivEntry 31 } cxMcVoxOpeFaxTimerWaitId OBJECT-TYPE SYNTAX INTEGER (0..65000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 65000 Default Value: 40000" DEFVAL { 40000 } ::= { cxMcVoxOpePortPrivEntry 32 } cxMcVoxOpeFaxMinPreambleDur OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1000" DEFVAL { 1000 } --#STARTING-VERSION 2 ::= { cxMcVoxOpePortPrivEntry 33 } cxMcVoxOpeFaxMaxPreambleDur OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 1200" DEFVAL { 1200 } --#STARTING-VERSION 2 ::= { cxMcVoxOpePortPrivEntry 34 } cxMcVoxOpeFaxMinPreambleDly OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 400" DEFVAL { 400 } --#STARTING-VERSION 2 ::= { cxMcVoxOpePortPrivEntry 35 } cxMcVoxOpeFaxMaxPreambleDly OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 900" DEFVAL { 900 } --#STARTING-VERSION 2 ::= { cxMcVoxOpePortPrivEntry 36 } cxMcVoxOpeFaxCedToneDetection OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 500" DEFVAL { 500 } --#STARTING-VERSION 2 ::= { cxMcVoxOpePortPrivEntry 37 } cxMcVoxOpeFaxCedMinToneDur OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 2600" DEFVAL { 2600 } --#STARTING-VERSION 2 ::= { cxMcVoxOpePortPrivEntry 38 } cxMcVoxOpeFaxCedMaxToneDur OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 4000" DEFVAL { 4000 } --#STARTING-VERSION 2 ::= { cxMcVoxOpePortPrivEntry 39 } cxMcVoxOpeFaxMaxHdlcFlags OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 127 Default Value: 32" DEFVAL { 32 } --#STARTING-VERSION 3 ::= { cxMcVoxOpePortPrivEntry 40 } -- ============================================================ cxMcVoxTimerOpePriv OBJECT IDENTIFIER ::= {cxMcVox 23 } -- (!!! new group) -- cxMcVox OPERATIONAL TIMERS PRIVATE GROUP cxMcVoxOpeTimerPrivTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxOpeTimerPrivEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Voice station planned Table." ::= { cxMcVoxTimerOpePriv 1 } cxMcVoxOpeTimerPrivEntry OBJECT-TYPE SYNTAX CxMcVoxOpeTimerPrivEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Voice station planned row definition." INDEX { cxMcVoxOpeInterfaceType } ::= { cxMcVoxOpeTimerPrivTable 1 } CxMcVoxOpeTimerPrivEntry ::= SEQUENCE { cxMcVoxOpeInterfaceType INTEGER, cxMcVoxOpeTimeSeizeIn INTEGER, cxMcVoxOpeTimeWaitDialOut INTEGER, cxMcVoxOpeTimeWaitDialIn INTEGER, cxMcVoxOpeTimeDialOut INTEGER, cxMcVoxOpeTimeDialIn INTEGER, cxMcVoxOpeTimeSiOff INTEGER, cxMcVoxOpeTimeProceed INTEGER, cxMcVoxOpeTimeAnswer INTEGER, cxMcVoxOpeTimeBeforeToneOff INTEGER, cxMcVoxOpeTimeWinkStartIn INTEGER, cxMcVoxOpeTimeWinkStartOut INTEGER, cxMcVoxOpeTimeWinkMin INTEGER, cxMcVoxOpeTimeWinkMax INTEGER, cxMcVoxOpeTimeSeize INTEGER, cxMcVoxOpeTimeDial INTEGER, cxMcVoxOpeTimeOffIn INTEGER, cxMcVoxOpeTimeSiOn INTEGER, cxMcVoxOpeTimeOffOut INTEGER, cxMcVoxOpeTimeDiscIn INTEGER, cxMcVoxOpeTimeDiscOut INTEGER, cxMcVoxOpeTimeToneOut INTEGER } cxMcVoxOpeInterfaceType OBJECT-TYPE SYNTAX INTEGER { em (1), fxs (2), fxo (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Displays the interface type of the voice I/O port. You cannot modify this object Options: em (1) fxs (2) fxo (3) Default: none" ::= { cxMcVoxOpeTimerPrivEntry 1 } -- scv timers cxMcVoxOpeTimeSeizeIn OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 50" DEFVAL { 50 } ::= { cxMcVoxOpeTimerPrivEntry 2 } cxMcVoxOpeTimeWaitDialOut OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 100" DEFVAL { 100 } ::= { cxMcVoxOpeTimerPrivEntry 3 } cxMcVoxOpeTimeWaitDialIn OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 200" DEFVAL { 200 } ::= { cxMcVoxOpeTimerPrivEntry 4 } cxMcVoxOpeTimeDialOut OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 50" DEFVAL { 50 } ::= { cxMcVoxOpeTimerPrivEntry 5 } cxMcVoxOpeTimeDialIn OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 30" DEFVAL { 30 } ::= { cxMcVoxOpeTimerPrivEntry 6 } cxMcVoxOpeTimeSiOff OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 300" DEFVAL { 300 } ::= { cxMcVoxOpeTimerPrivEntry 7 } cxMcVoxOpeTimeProceed OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 30000" DEFVAL { 30000 } ::= { cxMcVoxOpeTimerPrivEntry 8 } cxMcVoxOpeTimeAnswer OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 60000" DEFVAL { 60000 } ::= { cxMcVoxOpeTimerPrivEntry 9 } cxMcVoxOpeTimeBeforeToneOff OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 4000" DEFVAL { 4000 } ::= { cxMcVoxOpeTimerPrivEntry 10 } cxMcVoxOpeTimeWinkStartIn OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 220" DEFVAL { 220 } ::= { cxMcVoxOpeTimerPrivEntry 11 } cxMcVoxOpeTimeWinkStartOut OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 125" DEFVAL { 125 } ::= { cxMcVoxOpeTimerPrivEntry 12 } cxMcVoxOpeTimeWinkMin OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 140" DEFVAL { 140 } ::= { cxMcVoxOpeTimerPrivEntry 13 } cxMcVoxOpeTimeWinkMax OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 290" DEFVAL { 290 } ::= { cxMcVoxOpeTimerPrivEntry 14 } cxMcVoxOpeTimeSeize OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 250" DEFVAL { 250 } ::= { cxMcVoxOpeTimerPrivEntry 15 } cxMcVoxOpeTimeDial OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 210" DEFVAL { 210 } ::= { cxMcVoxOpeTimerPrivEntry 16 } cxMcVoxOpeTimeOffIn OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 900" DEFVAL { 900 } ::= { cxMcVoxOpeTimerPrivEntry 17 } cxMcVoxOpeTimeSiOn OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 100" DEFVAL { 100 } ::= { cxMcVoxOpeTimerPrivEntry 18 } cxMcVoxOpeTimeOffOut OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 150" DEFVAL { 150 } ::= { cxMcVoxOpeTimerPrivEntry 19 } cxMcVoxOpeTimeDiscIn OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 250" DEFVAL { 250 } ::= { cxMcVoxOpeTimerPrivEntry 20 } cxMcVoxOpeTimeDiscOut OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 650" DEFVAL { 650 } ::= { cxMcVoxOpeTimerPrivEntry 21 } cxMcVoxOpeTimeToneOut OBJECT-TYPE SYNTAX INTEGER (0..60000) ACCESS read-write STATUS mandatory DESCRIPTION "WARNING: YOU SHOULD NOT MODIFY THIS OBJECT WITHOUT THE SUPERVISION OF MEMOTEC PERSONNEL. Range of Values: 0 to 60000 Default Value: 15000" DEFVAL { 15000 } ::= { cxMcVoxOpeTimerPrivEntry 22 } -- ========================================================================= -- cxMcVox administrative GROUPID identification group cxMcVoxGrpIdAdmTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxGrpIdAdmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Voice Station Group Id identification Table." ::= { cxMcVox 10 } cxMcVoxGrpIdAdmEntry OBJECT-TYPE SYNTAX CxMcVoxGrpIdAdmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Associates an entry in the GroupId table with a pathId-like identifier for that groupId." INDEX { cxMcVoxGrpIdAdmIndex } ::= { cxMcVoxGrpIdAdmTable 1 } CxMcVoxGrpIdAdmEntry ::= SEQUENCE { cxMcVoxGrpIdAdmIndex INTEGER, cxMcVoxGrpIdAdm DisplayString, cxMcVoxGrpIdLenAdm INTEGER, cxMcVoxGrpIdAdmRowStatus INTEGER, cxMcVoxGrpIdAdmNbPoll INTEGER } cxMcVoxGrpIdAdmIndex OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the index number of the administrative Group ID. You cannot modify this object. It is a display that the software provides. Range of Values: 1 to 32 Default Value: none" ::= { cxMcVoxGrpIdAdmEntry 1 } cxMcVoxGrpIdAdm OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the administrative Group ID. The Group ID is a dialing code that the user enters to gain access to a remote telephone or FAX machine. The group contains up to 48 different Path IDs. Each of these Path IDs (i.e. specific routes to a destination) are polled until one of them is available to handle the call. Each of the Path IDs in the group must be on a separate CPU at the destination. Range of Values: 1 to 4 numeric digits Default Value: none Configuration Changed: administrative" ::= { cxMcVoxGrpIdAdmEntry 2 } cxMcVoxGrpIdLenAdm OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Determines the length (in digits) of the administrative Group ID. Range of Values: 1 to 4 Default Value: 3 Configuration Changed: administrative" DEFVAL { 3 } --#STARTING-VERSION 3 ::= { cxMcVoxGrpIdAdmEntry 3 } cxMcVoxGrpIdAdmRowStatus OBJECT-TYPE SYNTAX INTEGER { invalid (1), valid (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values will be disabled and the row will be deleted from the table. valid (2): values are enabled. Default Value: valid (2) Configuration Changed: administrative" ::= { cxMcVoxGrpIdAdmEntry 4 } cxMcVoxGrpIdAdmNbPoll OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-write STATUS optional DESCRIPTION "Determines the maximum number of remote voice stations in an Extension Group that the local voice station polls with a single call request. Note: This object is only relevant if at least one Remote Extension Group ID has been defined using the objects in the cxMcVox Administrative Grp Group. Range of Values: 1 to 20 Default Value: 4 Configuration Changed: administrative" DEFVAL { 4 } --#STARTING-VERSION 1 ::= { cxMcVoxGrpIdAdmEntry 5 } -- ==================================================================== -- cxMcVox operational GROUPID identification group cxMcVoxGrpIdOpeTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxGrpIdOpeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "cx Voice Station Group Id identification Table." ::= { cxMcVox 11 } cxMcVoxGrpIdOpeEntry OBJECT-TYPE SYNTAX CxMcVoxGrpIdOpeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Associates an entry in the GroupId table with a pathId-like identifier for that groupId." INDEX { cxMcVoxGrpIdOpeIndex } ::= { cxMcVoxGrpIdOpeTable 1 } CxMcVoxGrpIdOpeEntry ::= SEQUENCE { cxMcVoxGrpIdOpeIndex INTEGER, cxMcVoxGrpIdOpe DisplayString, cxMcVoxGrpIdLenOpe INTEGER, cxMcVoxGrpIdOpeNbPoll INTEGER } cxMcVoxGrpIdOpeIndex OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the index number of the operative Group ID. You cannot modify this object. Range of Values: 1 to 32 Default Value: none" ::= { cxMcVoxGrpIdOpeEntry 1 } cxMcVoxGrpIdOpe OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the operative Group ID. The Group ID is a dialing code the user enters to gain access to the remote telephone or FAX machine. The Group ID contains up to 48 different Path IDs. Each of these Path IDs (i.e. specific routes to a destination) are polled until one of them is available to handle the call. Each of the Path IDs in the group must be on a separate CPU at the destination. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxGrpIdAdm of the cxMcVox Administrative Group ID Identificastion Group. Range of Values: 1 to 4 numeric digits Default Value: none" ::= { cxMcVoxGrpIdOpeEntry 2 } cxMcVoxGrpIdLenOpe OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Determines the length (in digits) of the operative Group ID. You cannot moify this object. If you want to change the value you must modify the object cxMcVoxGrpIdLenAdm of the cxMcVox Administrative GROUPID identification group Range of Values: 1 to 4 Default Value: 3" DEFVAL { 3 } --#STARTING-VERSION 3 ::= { cxMcVoxGrpIdOpeEntry 3 } cxMcVoxGrpIdOpeNbPoll OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-only STATUS optional DESCRIPTION "Determines the maximum number of remote voice stations in an Extension Group that the local voice station polls with a single call request. Note: This object is only relevant if at least one Remote Extension Group ID has been defined using the objects in the cxMcVox Operative Grp Group. Range of Values: 1 to 20 Default Value: 4 Configuration Changed: operative" DEFVAL { 4 } --#STARTING-VERSION 1 ::= { cxMcVoxGrpIdOpeEntry 4 } -- ======================================================================== -- cxMcVox ADMINISTRATIVE GRP GROUP -- note: The group ID definition table must be defined after the path ID -- table. -- Also, a new group ID must be first identified in the group ID -- identification table. cxMcVoxGrpDefAdmTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxGrpDefAdmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Planned GroupID definition table." ::= { cxMcVox 12 } cxMcVoxGrpDefAdmEntry OBJECT-TYPE SYNTAX CxMcVoxGrpDefAdmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Planned GroupID row definition." INDEX { cxMcVoxGrpDefAdmIndex, cxMcVoxGrpDefAdmPriority } ::= { cxMcVoxGrpDefAdmTable 1 } CxMcVoxGrpDefAdmEntry ::= SEQUENCE { cxMcVoxGrpDefAdmIndex INTEGER, cxMcVoxGrpDefAdmPriority INTEGER, cxMcVoxGrpDefAdmRowStatus INTEGER, cxMcVoxGrpDefAdmPathId DisplayString, cxMcVoxGrpDefAdmRmtExt DisplayString } cxMcVoxGrpDefAdmIndex OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the index number of the administrative Group ID. You cannot modify this object. Range of Values: 1 to 32 Default Value: none" ::= { cxMcVoxGrpDefAdmEntry 1 } cxMcVoxGrpDefAdmPriority OBJECT-TYPE SYNTAX INTEGER (1..48) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the polling priority level of the administrative Path ID. When the user places a call by entering the Group ID, all Path IDs that you include in the group will be polled according to their priority until one is available to handle the call. You add a Path ID to a Group ID using the object cxMcVoxGrpDefAdmPathId of this table. You cannot modify this object. Range of Values: 1 to 48. A value of 1 assigns the highest priority to the Path ID. Default Value: none" ::= { cxMcVoxGrpDefAdmEntry 2 } cxMcVoxGrpDefAdmRowStatus OBJECT-TYPE SYNTAX INTEGER { invalid (1), valid (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values will be disabled and the row will be deleted from the table. valid (2): values are enabled. Default: valid (2) Configuration Changed: administrative" DEFVAL { valid } ::= { cxMcVoxGrpDefAdmEntry 3 } cxMcVoxGrpDefAdmPathId OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS deprecated DESCRIPTION "Determines the Path ID you want to include in the administrative Group ID. When you include a Path ID in the Group ID, the software automatically assigns a polling priority to it (see the object cxMcVoxGrpDefAdmPriority of this table). When the user places a call by entering the Group ID, all Path IDs that you include in the group will be polled according to their priority until one is available to handle the call. Range of Values: 1 to 4 numeric digits Default Value: none Configuration Changed: administrative" --#ENDING-VERSION 1 ::= { cxMcVoxGrpDefAdmEntry 4 } cxMcVoxGrpDefAdmRmtExt OBJECT-TYPE SYNTAX DisplayString (SIZE (1..5)) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the Remote Extension that you want to include in the Group ID. When you include a Remote Extension in the Group ID, the software automatically assigns a polling priority to it (see the object cxMcVoxGrpDefAdmPriority of this table). When the user places a call by entering the Group ID, all Remote Extensions that you include in the group will be polled according to their priority until one is available to handle the call. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: administrative" --#STARTING-VERSION 1 ::= { cxMcVoxGrpDefAdmEntry 5 } -- ========================================================================= -- cxMcVox OPERATIONAL GRP GROUP cxMcVoxGrpDefOpeTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxGrpDefOpeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Active GroupID definition table." ::= { cxMcVox 13 } cxMcVoxGrpDefOpeEntry OBJECT-TYPE SYNTAX CxMcVoxGrpDefOpeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Active GroupID row definition." INDEX { cxMcVoxGrpDefOpeIndex, cxMcVoxGrpDefOpePriority } ::= { cxMcVoxGrpDefOpeTable 1 } CxMcVoxGrpDefOpeEntry ::= SEQUENCE { cxMcVoxGrpDefOpeIndex INTEGER, cxMcVoxGrpDefOpePriority INTEGER, cxMcVoxGrpDefOpePathId DisplayString, cxMcVoxGrpDefOpeRmtExt DisplayString } cxMcVoxGrpDefOpeIndex OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the index number of the operative Group ID. You cannot modify this object. Range of Values: 1 to 32 Default Value: none" ::= { cxMcVoxGrpDefOpeEntry 1 } cxMcVoxGrpDefOpePriority OBJECT-TYPE SYNTAX INTEGER (1..48) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the polling priority level of the operative Path ID. When the user places a call by entering the Group ID, all Path IDs that you include in the group will be polled according to their priority until one is available to handle the call. You add a Path ID to a Group ID using the object cxMcVoxGrpDefAdmPathId of the cxMcVox Administrative Grp Group. You cannot modify this object Range of Values: 1 to 48. A value of 1 assigns the highest priority to the Path ID. Default Value: none" ::= { cxMcVoxGrpDefOpeEntry 2 } cxMcVoxGrpDefOpePathId OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only STATUS deprecated DESCRIPTION "Displays the Path ID included in the operative Group ID. When you include a Path ID in the Group ID, the software automatically assigns a polling priority to it (see the object cxMcVoxGrpDefAdmPriority of this table). When the user places a call by entering the Group ID, all Path IDs that you include in the group will be polled according to their priority until one is available to handle the call. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxGrpDefAdmPathId of the cxMcVox Administrative GRP Group Range of Values: 1 to 4 numeric digits Default Value: none" --#ENDING-VERSION 1 ::= { cxMcVoxGrpDefOpeEntry 3 } cxMcVoxGrpDefOpeRmtExt OBJECT-TYPE SYNTAX DisplayString (SIZE (1..5)) ACCESS read-only STATUS mandatory DESCRIPTION "Determines the Remote Extension that you want to include in the Group ID. When you include a Remote Extension in the Group ID, the software automatically assigns a polling priority to it (see the object cxMcVoxGrpDefOpePriority of this table). When the user places a call by entering the Group ID, all Remote Extensions that you include in the group will be polled according to their priority, until one is available to handle the call. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: operative" --#STARTING-VERSION 1 ::= { cxMcVoxGrpDefOpeEntry 4 } -- ========================================================================= -- cxMcVox ADMINISTRATION PERSONAL IDENTIFICATION NUMBER GROUP cxMcVoxAdmPinTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxAdmPinEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Personal identification number Table." --#STARTING-VERSION 4 ::= { cxMcVox 14 } cxMcVoxAdmPinEntry OBJECT-TYPE SYNTAX CxMcVoxAdmPinEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Personal identification number row definition." INDEX { cxMcVoxAdmPinIndex } ::= { cxMcVoxAdmPinTable 1 } CxMcVoxAdmPinEntry ::= SEQUENCE { cxMcVoxAdmPinIndex INTEGER, cxMcVoxAdmPinCode DisplayString, cxMcVoxAdmPinRowStatus INTEGER } cxMcVoxAdmPinIndex OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the index number of the Personal Identification Number (PIN). You cannot modify this object. Range of Values: 1 to 256 Default Value: none" ::= { cxMcVoxAdmPinEntry 1 } cxMcVoxAdmPinCode OBJECT-TYPE SYNTAX DisplayString (SIZE (2..8)) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the Personal Identification Number (PIN) that is validated by the local voice station prior to a call being established. The local voice station verifies that the PIN included in the call request packet is listed in its PIN table. If it is not,the call will not be established and the user will hear a fast busy signal. Range of Values: 2 to 8 digits from 0 to 9 Default Value: none" ::= { cxMcVoxAdmPinEntry 2 } cxMcVoxAdmPinRowStatus OBJECT-TYPE SYNTAX INTEGER { invalid (1), valid (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values will be disabled and the row will be deleted from the table. valid (2): values are enabled Default Value: none" ::= { cxMcVoxAdmPinEntry 3 } -- ========================================================================= -- cxMcVox OPERATIONAL PERSONAL IDENTIFICATION NUMBER GROUP cxMcVoxOpePinTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxOpePinEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Personal identification number Table." --#STARTING-VERSION 4 ::= { cxMcVox 15 } cxMcVoxOpePinEntry OBJECT-TYPE SYNTAX CxMcVoxOpePinEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Personal identification number row definition." INDEX { cxMcVoxOpePinIndex } ::= { cxMcVoxOpePinTable 1 } CxMcVoxOpePinEntry ::= SEQUENCE { cxMcVoxOpePinIndex INTEGER, cxMcVoxOpePinCode DisplayString } cxMcVoxOpePinIndex OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the index number of the Personal identification Number (PIN). You cannot modify this object. Range of Values: 1 to 256. Default Value: none" ::= { cxMcVoxOpePinEntry 1 } cxMcVoxOpePinCode OBJECT-TYPE SYNTAX DisplayString (SIZE (2..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the Personal Identification Number (PIN) that is validated by the local voice station prior to a call being established. The local voice station verifies that the PIN included in the call request packet is listed in its PIN table. If it is not,the call will not be established and the user will hear a fast busy signal. Range of Values: 2 to 8 digits from 0 to 9 Default Value: none" ::= { cxMcVoxOpePinEntry 2 } -- ======================================================================= -- cxMcVox ADMINISTRATIVE LOCAL ZONE CODES GROUP -- cxMcVoxAdmLclZoneTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxAdmLclZoneEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Local Zone Codes Table." ::= { cxMcVox 16 } cxMcVoxAdmLclZoneEntry OBJECT-TYPE SYNTAX CxMcVoxAdmLclZoneEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Local Zones codes row definition." INDEX { cxMcVoxAdmLclZoneIndex } ::= { cxMcVoxAdmLclZoneTable 1 } CxMcVoxAdmLclZoneEntry ::= SEQUENCE { cxMcVoxAdmLclZoneIndex INTEGER, cxMcVoxAdmLclZoneCode DisplayString, cxMcVoxAdmLclZoneLng INTEGER, cxMcVoxAdmLclZoneRowStatus INTEGER } cxMcVoxAdmLclZoneIndex OBJECT-TYPE SYNTAX INTEGER (1..128) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the index number of the administrative local zone code. Range of Values: 1 to 128. Default Value: none" --#STARTING-VERSION 3 ::= { cxMcVoxAdmLclZoneEntry 1 } cxMcVoxAdmLclZoneCode OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the number of the administrative local zone code which will serve in the verification of the phone number to be dialed depending on where the remote site is installed. Range of Values: 1 to 4 digits from 0 to 9 Note: The * character is used as a wildcard character. Only one wildcard character can be used per zone code. Default Value: none" --#STARTING-VERSION 3 ::= { cxMcVoxAdmLclZoneEntry 2 } cxMcVoxAdmLclZoneLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Determines the length (in digits) of the administrative local zone code. Range of Values: 1 to 4 Default Value: none" --#STARTING-VERSION 3 ::= { cxMcVoxAdmLclZoneEntry 3 } cxMcVoxAdmLclZoneRowStatus OBJECT-TYPE SYNTAX INTEGER { invalid (1), valid (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values will be disabled and the row will be deleted from the table. valid (2): values are enabled Default Value: none" --#STARTING-VERSION 3 ::= { cxMcVoxAdmLclZoneEntry 4 } -- ====================================================================== -- cxMcVox OPERATIONAL LOCAL ZONE CODE GROUP -- cxMcVoxOpeLclZoneTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxOpeLclZoneEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Local Zones Codes Table." ::= { cxMcVox 17 } cxMcVoxOpeLclZoneEntry OBJECT-TYPE SYNTAX CxMcVoxOpeLclZoneEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Local Zones codes row definition." INDEX { cxMcVoxOpeLclZoneIndex } ::= { cxMcVoxOpeLclZoneTable 1 } CxMcVoxOpeLclZoneEntry ::= SEQUENCE { cxMcVoxOpeLclZoneIndex INTEGER, cxMcVoxOpeLclZoneCode DisplayString, cxMcVoxOpeLclZoneLng INTEGER } cxMcVoxOpeLclZoneIndex OBJECT-TYPE SYNTAX INTEGER (1..128) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the index number of the operational local zone code. Range of Values: 1 to 128. Default Value: none" --#STARTING-VERSION 3 ::= { cxMcVoxOpeLclZoneEntry 1 } cxMcVoxOpeLclZoneCode OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the number of the operational local zone code which will serve in the verification of the phone number to be dialed depending on where the remote CX1000 is installed. You cannot modify this object. If you want to change the code you must change the setting of the cxMcVoxAdmLclZoneCode object in the cxMcVox Administrative Zone Codes Group. Range of Values: 1 to 4 digits from 0 to 9 Note: The * character is used as a wildcard character. Only one wildcard character can be used per zone code. Default Value: none" --#STARTING-VERSION 3 ::= { cxMcVoxOpeLclZoneEntry 2 } cxMcVoxOpeLclZoneLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the length (in digits) of the operational local zone code. You cannot modify this object. If you want to change the length you must change the setting of the object cxMcVoxAdmLclZoneLng of the cxMccVox Administrative Local Zone Codes Group. Range of Values: 1 to 4 Default Value: none" --#STARTING-VERSION 3 ::= { cxMcVoxOpeLclZoneEntry 3 } -- ====================================================================== -- cxMcVox ADMINISTRATION REMOTE TRANSLATIONS CODES GROUP -- DEPRECATED cxMcVoxAdmRTC OBJECT IDENTIFIER ::= {cxMcVox 18 } cxMcVoxAdmRTCCountry OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Determines the number of the administrative local country code which will serve in the verification of the phone number to be dialed depending on where the remote CX1000 is installed. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxAdmRTC 1 } cxMcVoxAdmRTCCountryLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-write STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Determines the length (in digits) of the administrative local country code. Range of Values: 1 to 4 Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxAdmRTC 2 } cxMcVoxAdmRTCNonLclCountry OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Determines the number of the administrative local country code which will be inserted in front of the Country Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxAdmRTC 3 } cxMcVoxAdmRTCNonLclCountryLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-write STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Determines the length (in digits) of the administrative non local country code. Range of Values: 1 to 4. Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxAdmRTC 4 } cxMcVoxAdmRTCArea OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Determines the number of the administrative local area code which will serve in the verification of the phone number to be dialed depending on where the remote CX1000 is installed. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxAdmRTC 5 } cxMcVoxAdmRTCAreaLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-write STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Determines the length (in digits) of the administrative local area code. Range of Values: 1 to 4 Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxAdmRTC 6 } cxMcVoxAdmRTCNonLclArea OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Determines the number of the administrative local area code which will be inserted in front of the Area Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxAdmRTC 7 } cxMcVoxAdmRTCNonLclAreaLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-write STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Determines the length (in digits) of the administrative non local area code. Range of Values: 1 to 4. Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxAdmRTC 8 } cxMcVoxAdmRTCNonLclZone OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Determines the number of the administrative local zone code which will be inserted in front of the Zone Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxAdmRTC 9 } cxMcVoxAdmRTCNonLclZoneLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-write STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Determines the length (in digits) of the administrative non local zone code. Range of Values: 1 to 4 Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxAdmRTC 10 } -- ====================================================================== -- cxMcVox OPERATIONAL REMOTE TRANSLATIONS CODES GROUP -- DEPRECATED cxMcVoxOpeRTC OBJECT IDENTIFIER ::= {cxMcVox 19 } cxMcVoxOpeRTCCountry OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Displays the number of the operative local country code which will serve in the verification of the phone number to be dialed depending on where the remote CX1000 is installed. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none." --#ENDING-VERSION 3 ::= { cxMcVoxOpeRTC 1 } cxMcVoxOpeRTCCountryLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Displays the length (in digits) of the operative local country code. Range of Values: 1 to 4. Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxOpeRTC 2 } cxMcVoxOpeRTCNonLclCountry OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Displays the number of the operative local country code which will be inserted in front of the Country Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxOpeRTC 3 } cxMcVoxOpeRTCNonLclCountryLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Displays the length (in digits) of the operative non local country code. Range of Values: 1 to 4. Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxOpeRTC 4 } cxMcVoxOpeRTCArea OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Displays the number of the operative local area code which will serve in the verification of the phone number to be dialed depending on where the remote CX1000 is installed. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxOpeRTC 5 } cxMcVoxOpeRTCAreaLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Displays the length (in digits) of the operative local area code. Range of Values: 1 to 4. Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxOpeRTC 6 } cxMcVoxOpeRTCNonLclArea OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Displays the number of the operative local area code which will be inserted in front of the Area Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxOpeRTC 7 } cxMcVoxOpeRTCNonLclAreaLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Displays the length (in digits) of the operative non local area code. Range of Values: 1 to 4 Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxOpeRTC 8 } cxMcVoxOpeRTCNonLclZone OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Displays the number of the operative local zone code which will be inserted in front of the Zone Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxOpeRTC 9 } cxMcVoxOpeRTCNonLclZoneLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS deprecated DESCRIPTION "The CX900 does not currently support this object. Displays the length (in digits) of the operative non local zone code. Range of Values: 1 to 4 Default Value: none" --#ENDING-VERSION 3 ::= { cxMcVoxOpeRTC 10 } -- ====================================================================== -- cxMcVox DIAGNOSTIC GROUP cxMcVoxDiagTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxDiagEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Voice station diagnostics and events Table." ::= { cxMcVox 24 } cxMcVoxDiagEntry OBJECT-TYPE SYNTAX CxMcVoxDiagEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { cxMcVoxDiagCardIndex, cxMcVoxDiagPortIndex } ::= { cxMcVoxDiagTable 1 } CxMcVoxDiagEntry ::= SEQUENCE { cxMcVoxDiagCardIndex INTEGER, cxMcVoxDiagPortIndex INTEGER, cxMcVoxDiagScvEvents INTEGER, cxMcVoxDiagGsdEvents INTEGER, cxMcVoxDiagToneInEvents INTEGER, cxMcVoxDiagToneOutEvents INTEGER, cxMcVoxDiagFaxInEvents INTEGER, cxMcVoxDiagFaxOutEvents INTEGER, cxMcVoxDiagGlmEvents INTEGER, cxMcVoxDiagIbvDiags INTEGER, cxMcVoxDiagPcvDiags INTEGER, cxMcVoxDiagGcvDiags INTEGER, cxMcVoxDiagFaxDiags INTEGER, cxMcVoxDiagLseDiags INTEGER, cxMcVoxDiagScvDiags INTEGER, cxMcVoxDiagGlmDiags INTEGER } cxMcVoxDiagCardIndex OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cxMcVoxDiagEntry 1 } cxMcVoxDiagPortIndex OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { cxMcVoxDiagEntry 2 } cxMcVoxDiagScvEvents OBJECT-TYPE SYNTAX INTEGER { no-action (1), trigger (2), reset (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" DEFVAL { no-action } ::= { cxMcVoxDiagEntry 3 } cxMcVoxDiagGsdEvents OBJECT-TYPE SYNTAX INTEGER { no-action (1), trigger (2), reset (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" DEFVAL { no-action } ::= { cxMcVoxDiagEntry 4 } cxMcVoxDiagToneInEvents OBJECT-TYPE SYNTAX INTEGER { no-action (1), trigger (2), reset (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" DEFVAL { no-action } ::= { cxMcVoxDiagEntry 5 } cxMcVoxDiagToneOutEvents OBJECT-TYPE SYNTAX INTEGER { no-action (1), trigger (2), reset (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" DEFVAL { no-action } ::= { cxMcVoxDiagEntry 6 } cxMcVoxDiagFaxInEvents OBJECT-TYPE SYNTAX INTEGER { no-action (1), trigger (2), reset (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" DEFVAL { no-action } ::= { cxMcVoxDiagEntry 7 } cxMcVoxDiagFaxOutEvents OBJECT-TYPE SYNTAX INTEGER { no-action (1), trigger (2), reset (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" DEFVAL { no-action } ::= { cxMcVoxDiagEntry 8 } cxMcVoxDiagGlmEvents OBJECT-TYPE SYNTAX INTEGER { no-action (1), trigger (2), reset (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" DEFVAL { no-action } ::= { cxMcVoxDiagEntry 9 } cxMcVoxDiagIbvDiags OBJECT-TYPE SYNTAX INTEGER { no-action (1), trigger (2), reset (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" DEFVAL { no-action } ::= { cxMcVoxDiagEntry 10 } cxMcVoxDiagPcvDiags OBJECT-TYPE SYNTAX INTEGER { no-action (1), trigger (2), reset (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" DEFVAL { no-action } ::= { cxMcVoxDiagEntry 11 } cxMcVoxDiagGcvDiags OBJECT-TYPE SYNTAX INTEGER { no-action (1), trigger (2), reset (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" DEFVAL { no-action } ::= { cxMcVoxDiagEntry 12 } cxMcVoxDiagFaxDiags OBJECT-TYPE SYNTAX INTEGER { no-action (1), trigger (2), reset (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" DEFVAL { no-action } ::= { cxMcVoxDiagEntry 13 } cxMcVoxDiagLseDiags OBJECT-TYPE SYNTAX INTEGER { no-action (1), trigger (2), reset (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" DEFVAL { no-action } ::= { cxMcVoxDiagEntry 14 } cxMcVoxDiagScvDiags OBJECT-TYPE SYNTAX INTEGER { no-action (1), trigger (2), reset (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" DEFVAL { no-action } ::= { cxMcVoxDiagEntry 15 } cxMcVoxDiagGlmDiags OBJECT-TYPE SYNTAX INTEGER { no-action (1), trigger (2), reset (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" DEFVAL { no-action } ::= { cxMcVoxDiagEntry 16 } -- ====================================================================== -- cxMcVox Download GROUP. cxMcVoxDownload OBJECT IDENTIFIER ::= {cxMcVox 25 } -- ====================================================================== -- cxMcVox ADMINISTRATIVE LOCAL EXTENSION GROUP cxMcVoxLclExtAdmTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxLclExtAdmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Planned Local Extensions table." --#STARTING-VERSION 1 ::= { cxMcVox 26 } cxMcVoxLclExtAdmEntry OBJECT-TYPE SYNTAX CxMcVoxLclExtAdmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Planned Local Extensions row definition." INDEX { cxMcVoxLclExtAdmIndex } ::= { cxMcVoxLclExtAdmTable 1 } CxMcVoxLclExtAdmEntry ::= SEQUENCE { cxMcVoxLclExtAdmIndex INTEGER, cxMcVoxLclExtAdmRowStatus INTEGER, cxMcVoxLclExtAdmExt DisplayString, cxMcVoxLclExtAdmHuntChnl INTEGER } cxMcVoxLclExtAdmIndex OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the index number of the Remote Extension. You cannot modify this object. Range of Values: 1 to 64 Default Value: none" ::= { cxMcVoxLclExtAdmEntry 1 } cxMcVoxLclExtAdmRowStatus OBJECT-TYPE SYNTAX INTEGER { invalid (1), valid (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the status of the objects in a table row. Options: invalid (1): row is flagged; after the next reset the values are disabled and the row is deleted from the table. valid (2): values are enabled. Default Value: none Configuration Changed: administrative" ::= { cxMcVoxLclExtAdmEntry 2 } cxMcVoxLclExtAdmExt OBJECT-TYPE SYNTAX DisplayString (SIZE (1..5)) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the numeric dialing code to be dialed by remote located parties to access the local telephone or fax machine. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: administrative" ::= { cxMcVoxLclExtAdmEntry 3 } cxMcVoxLclExtAdmHuntChnl OBJECT-TYPE SYNTAX INTEGER (1..1073741823) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the local voice channels to be polled (hunted) during call establishment with the Local Extension (specified by object cxMcVoxLclExtAdmExt). This value acts as a mask so that all specified channels are polled until the call is accepted. This hunt channel mask includes a maximum of 30 voice channels. The default value includes all local voice channels. If you want to exclude specific channels, calculate the value by following these steps: 1. Decide which ports to include, for example, 1,5,8,29. 2. Convert the list of ports to a series of bits. Start with a list of 30 zeros. 00 0000 0000 0000 0000 0000 0000 0000 To include ports 1, 5, 8, and 29, place 1s in these positions. Numbering starts at 1 at the extreme right. 01 0000 0000 0000 0000 0000 1001 0001 3. Convert this number to hexadecimal. 10000091 4. Convert this number to decimal. 268 435 601 Range of Values: 1 to 1073741823 Default Value: 1073741823 Configuration Changed: administrative" DEFVAL { 1073741823 } ::= { cxMcVoxLclExtAdmEntry 4 } -- ================================================================== -- cxMcVox OPERATIONAL LOCAL EXTENSION GROUP cxMcVoxLclExtOpeTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxLclExtOpeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Active Local Extensions table." --#STARTING-VERSION 1 ::= { cxMcVox 27 } cxMcVoxLclExtOpeEntry OBJECT-TYPE SYNTAX CxMcVoxLclExtOpeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Active Local Extensions row definition." INDEX { cxMcVoxLclExtOpeIndex } ::= { cxMcVoxLclExtOpeTable 1 } CxMcVoxLclExtOpeEntry ::= SEQUENCE { cxMcVoxLclExtOpeIndex INTEGER, cxMcVoxLclExtOpeExt DisplayString, cxMcVoxLclExtOpeHuntChnl INTEGER } cxMcVoxLclExtOpeIndex OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the index number of the Remote Extension. You cannot modify this object. Range of Values: 1 to 64 Default Value: none" ::= { cxMcVoxLclExtOpeEntry 1 } cxMcVoxLclExtOpeExt OBJECT-TYPE SYNTAX DisplayString (SIZE (1..5)) ACCESS read-only STATUS mandatory DESCRIPTION "Determines the numeric dialing code to be dialed by remote located parties to access the local telephone or fax machine. Range of Values: 1 to 5 numeric digits Default Value: none Configuration Changed: operational" ::= { cxMcVoxLclExtOpeEntry 2 } cxMcVoxLclExtOpeHuntChnl OBJECT-TYPE SYNTAX INTEGER (1..1073741823) ACCESS read-only STATUS mandatory DESCRIPTION "Defines the local voice channels to be polled (hunted) during call establishment with the Local Extension (specified by object cxMcVoxLclExtAdmExt). This value acts as a mask so that all specified channels are polled until the call is accepted. This hunt channel mask includes a maximum of 30 voice channels. The default value includes all local voice channels. If you want to exclude specific channels, calculate the value by following these steps: 1. Decide which ports to include, for example, 1,5,8,29. 2. Convert the list of ports to a series of bits. Start with a list of 30 zeros. 00 0000 0000 0000 0000 0000 0000 0000 To include ports 1, 5, 8, and 29, place 1s in these positions. Numbering starts at 1 at the extreme right. 01 0000 0000 0000 0000 0000 1001 0001 3. Convert this number to hexadecimal. 10000091 4. Convert this number to decimal. 268 435 601 Range of Values: 1 to 1073741823 Default Value: 1073741823 Configuration Changed: operational" DEFVAL { 1073741823 } ::= { cxMcVoxLclExtOpeEntry 3 } -- ====================================================================== -- cxMcVox Regeneration Operational GROUP. cxMcVoxRegenOpe OBJECT IDENTIFIER ::= { cxMcVox 28 } cxMcVoxRegenOpeExt OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The RegenOpeExt is used to specify if the local extension tones are to be regenerated." DEFVAL { disabled } --#STARTING-VERSION 3 ::= { cxMcVoxRegenOpe 1 } cxMcVoxRegenOpeGid OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The RegenOpeGid is used to specify if the group ids tones are to be regenerated." DEFVAL { disabled } --#STARTING-VERSION 3 ::= { cxMcVoxRegenOpe 2 } cxMcVoxRegenOpeNbDigits OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-write STATUS mandatory DESCRIPTION "The number of digits to be regenerated." DEFVAL { 3 } --#STARTING-VERSION 3 ::= { cxMcVoxRegenOpe 3 } cxMcVoxRegenOpeExtBitMask OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This object is a bitmap that selects up to cxMcVoxRegenOpeNbDigits, which can be set up to 8 digits, corresponding to a bit that is set. The default value corresponds to 7 (or 00000111 in binary). Range of Values: 0 to 255 Default Value: 7" DEFVAL { 7 } --#STARTING-VERSION 11 ::= { cxMcVoxRegenOpe 4 } -- ====================================================================== -- cxMcVox OPERATIONAL CODE TRANSLATION GROUP -- cxMcVoxTranslOpe OBJECT IDENTIFIER ::= {cxMcVox 29 } cxMcVoxTranslOpeCntryCodeEnable OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This specifies whether to translate the local country code." DEFVAL { disabled } --#STARTING-VERSION 3 ::= { cxMcVoxTranslOpe 1 } cxMcVoxTranslOpeCntryCode OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS mandatory DESCRIPTION "Displays the number of the operational local country code which will serve in the verification of the phone number to be dialed depending on where the remote site is installed. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none." DEFVAL { "1" } --#STARTING-VERSION 3 ::= { cxMcVoxTranslOpe 2 } cxMcVoxTranslOpeCntryCodeLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the length (in digits) of the operational local country code. Range of Values: 1 to 4. Default Value: none" DEFVAL { 1 } --#STARTING-VERSION 3 ::= { cxMcVoxTranslOpe 3 } cxMcVoxTranslOpeCCPrefix OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS mandatory DESCRIPTION "Displays the number of the operational local country code which will be inserted in front of the Country Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none" DEFVAL { "2" } --#STARTING-VERSION 3 ::= { cxMcVoxTranslOpe 4 } cxMcVoxTranslOpeCCPrefixLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the length (in digits) of the operational non local country code. Range of Values: 1 to 4. Default Value: none" DEFVAL { 1 } --#STARTING-VERSION 3 ::= { cxMcVoxTranslOpe 5 } cxMcVoxTranslOpeAreaCodeEnable OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This specifies whether to translate the local area code." DEFVAL { disabled } --#STARTING-VERSION 3 ::= { cxMcVoxTranslOpe 6 } cxMcVoxTranslOpeAreaCode OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS mandatory DESCRIPTION "Displays the number of the operational local area code which will serve in the verification of the phone number to be dialed depending on where the remote site is installed. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none" DEFVAL { "514" } --#STARTING-VERSION 3 ::= { cxMcVoxTranslOpe 7 } cxMcVoxTranslOpeAreaCodeLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the length (in digits) of the operational local area code. Range of Values: 1 to 4. Default Value: none" DEFVAL { 3 } --#STARTING-VERSION 3 ::= { cxMcVoxTranslOpe 8 } cxMcVoxTranslOpeACPrefix OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS mandatory DESCRIPTION "Displays the number of the operational local area code which will be inserted in front of the Area Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none" DEFVAL { "1" } --#STARTING-VERSION 3 ::= { cxMcVoxTranslOpe 9 } cxMcVoxTranslOpeACPrefixLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the length (in digits) of the operational non local area code. Range of Values: 1 to 4 Default Value: none" DEFVAL { 1 } --#STARTING-VERSION 3 ::= { cxMcVoxTranslOpe 10 } cxMcVoxTranslOpeZoneCodeEnable OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This specifies whether to translate the local zone code." DEFVAL { disabled } --#STARTING-VERSION 3 ::= { cxMcVoxTranslOpe 11 } cxMcVoxTranslOpeZCPrefix OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-write STATUS mandatory DESCRIPTION "Displays the number of the operational local zone code which will be inserted in front of the Zone Code if the latter does not correspond to the local country code parameter. Range of Values: 1 to 4 digits from 0 to 9 Default Value: none" DEFVAL { "7" } --#STARTING-VERSION 3 ::= { cxMcVoxTranslOpe 12 } cxMcVoxTranslOpeZCPrefixLng OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the length (in digits) of the operational non local zone code. Range of Values: 1 to 4 Default Value: none" DEFVAL { 1 } --#STARTING-VERSION 3 ::= { cxMcVoxTranslOpe 13 } -- ====================================================================== -- cxMcVox CALL HISTORY GROUP -- cxMcVoxHistoryTable OBJECT-TYPE SYNTAX SEQUENCE OF CxMcVoxHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "OnLine/OffLine history table for incoming/outgoing calls." --#STARTING-VERSION 5 ::= { cxMcVox 30 } cxMcVoxHistoryEntry OBJECT-TYPE SYNTAX CxMcVoxHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Online/Offline history row definition." INDEX { cxMcVoxHistoryIndex } ::= { cxMcVoxHistoryTable 1 } CxMcVoxHistoryEntry ::= SEQUENCE { cxMcVoxHistoryIndex INTEGER, cxMcVoxHistoryLclCardNumber INTEGER, cxMcVoxHistoryLclPortNumber INTEGER, cxMcVoxHistoryRmtCardNumber INTEGER, cxMcVoxHistoryRmtPortNumber INTEGER, cxMcVoxHistoryTimeStampOnLine INTEGER, cxMcVoxHistoryTimeStampOffLine INTEGER, cxMcVoxHistoryLnkState DisplayString, cxMcVoxHistoryPin DisplayString, cxMcVoxHistoryExtensionOrGrpId DisplayString, cxMcVoxHistoryPhoneNumber DisplayString } cxMcVoxHistoryIndex OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-only STATUS mandatory DESCRIPTION "The index number of the history log." ::= { cxMcVoxHistoryEntry 1 } cxMcVoxHistoryLclCardNumber OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the voice I/O card slot displacement from the CPU card slot. As an example on the CX1000, card number 1 is directly behind the CPU card and card number 2 is one slot up. In the case of the CX900 product, this card number represents the logical slot corresponding to its physical slot as mapped in the 'voxcard' table. You cannot modify this object. Range of Values: 1 to 4 Default Value: none" ::= { cxMcVoxHistoryEntry 2 } cxMcVoxHistoryLclPortNumber OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the number of the voice I/O port. You cannot modify this object. Range of Values: 1 to 15 Default Value: none" ::= { cxMcVoxHistoryEntry 3 } cxMcVoxHistoryRmtCardNumber OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the remote voice I/O card slot displacement from the CPU card slot. As an example on the CX1000, card number 1 is directly behind th You cannot modify this object. Range of Values: 1 to 4 Default Value: none" ::= { cxMcVoxHistoryEntry 4 } cxMcVoxHistoryRmtPortNumber OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the number of the voice I/O port that was reached at the remote location. You cannot modify this object. Range of Values: 1 to 15 Default Value: none" ::= { cxMcVoxHistoryEntry 5 } cxMcVoxHistoryTimeStampOnLine OBJECT-TYPE SYNTAX INTEGER(1.. 4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the time stamp of the last on-line event. An on-line event is any incoming or outgoing call that is started. The time stamp indicates the number of seconds elapsed since the last power up. You cannot modify this object. Range of Values: 1 to 4294967295 Default Value: none" ::= { cxMcVoxHistoryEntry 6 } cxMcVoxHistoryTimeStampOffLine OBJECT-TYPE SYNTAX INTEGER(1.. 4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the time stamp of the last off-line event. An off-line event is any incoming or outgoing call that the voice station terminates. The time stamp indicates the number of seconds elapsed since the last power up. You cannot modify this object. Range of Values: 1 to 4294967295 Default Value: none" ::= { cxMcVoxHistoryEntry 7 } cxMcVoxHistoryLnkState OBJECT-TYPE SYNTAX DisplayString (SIZE(1..16)) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the status of the link to the remote user. When the call is successful the status is either 'Incoming' or 'Outgoing'. Else the error type is displayed. You cannot modify this object. Options: Connection established: either 'Incoming' or 'Outgoing' Local port unavailable: 'LclPortUnavail' Remote extension unavailable: 'RmtExtUnavail' Remote ports busy: 'RmtPortsBusy' Invalid PIN: 'InvalidPIN' Call aborted: 'CallAborted' Default Value: 'CallAborted'" DEFVAL { "CallAborted" } ::= { cxMcVoxHistoryEntry 8 } cxMcVoxHistoryPin OBJECT-TYPE SYNTAX DisplayString (SIZE (2..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the Personal Identification Number (PIN) that is validated against the local voice station card PIN number table. Range of Values: 2 to 8 numeric digits, each number from 0 to 9 Default Value: none" ::= { cxMcVoxHistoryEntry 9 } cxMcVoxHistoryExtensionOrGrpId OBJECT-TYPE SYNTAX DisplayString (SIZE (1..4)) ACCESS read-only STATUS mandatory DESCRIPTION "Displays the extension or group ID the remote user has dialed to reach the local user. This object is irrelevant for outgoing calls. You cannot modify this object. Range of Values: 1 to 4 numeric digits Default Value: none" ::= { cxMcVoxHistoryEntry 10 } cxMcVoxHistoryPhoneNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (1..24)) ACCESS read-only STATUS mandatory DESCRIPTION "For outgoing calls, this object displays the complete phone number (including any voice mail digits) the user entered to reach the remote user. This can include access code, country code, area code and zone code but excludes PIN number. For incoming calls, this object displays either the regenerated code or the translated code (or both). Codes that are dialed after the extension or group ID are also logged in this object both for outgoing and incoming calls. You cannot modify this object. Range of Values: 1 to 24 numeric digits Default Value: none" ::= { cxMcVoxHistoryEntry 11 } -- TRAPS cxMcVoxTrapStatus TRAP-TYPE ENTERPRISE cxMcVox VARIABLES { cxModuleHwPhysSlot, cxMcVoxStatusCardNumber, cxMcVoxStatusPortNumber, cxMcVoxStatusPortStatus } DESCRIPTION "Reports that there is a change in the functional state of the voice channel. cxMcVoxTrapStatus = 1 if the port is disabled cxMcVoxTrapStatus = 2 if the port is enabled cxMcVoxTrapStatus = 3 if there is no I/O hardware" ::= 1 cxMcVoxTrapRing TRAP-TYPE ENTERPRISE cxMcVox VARIABLES { cxModuleHwPhysSlot, cxMcVoxGlobalTensionRing } DESCRIPTION "Reports that there is a change in the functional state of the ring generator power supply. cxMcVoxTrapRing = 2 if the ringing generator is good cxMcVoxTrapRing = 1 otherwise" ::= 2 cxMcVoxTrapDc TRAP-TYPE ENTERPRISE cxMcVox VARIABLES { cxModuleHwPhysSlot, cxMcVoxGlobalTensionDc } DESCRIPTION "Reports that there is a change in the functional state of the DC power supply. cxMcVoxGlobalTensionDc = 2 if the DC power supply is good cxMcVoxGlobalTensionDc = 1 otherwise" ::= 3 cxMcVoxHistoryTrap TRAP-TYPE ENTERPRISE cxMcVox VARIABLES { cxModuleHwPhysSlot, cxMcVoxHistoryIndex, cxMcVoxGlobalHistoryMaxNumberOfEntries } DESCRIPTION "Informs the management station of the fact that the history table needs servicing." ::= 4 END