CXEthIo-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 cxEthIo, Alias FROM CXProduct-SMI; -- Active Configuration Table -- The table describing: -- active (current) parameters used in the Ethernet SAP and its associated -- hardware port. status and statistics for each hardware port that is -- associated with an Ethernet SAP. ethSapOprTable OBJECT-TYPE SYNTAX SEQUENCE OF EthSapOprEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Provides configuration information for each Ethernet service access point and its associated hardware ports. It also provides statistical information about activity at the interface. Each row of the table (entry) contains information that corresponds to a particular service access point." ::= { cxEthIo 1 } ethSapOprEntry OBJECT-TYPE SYNTAX EthSapOprEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Provides the configuration of a particular Ethernet service access point and its associated hardware port. It also provides statistical information about activity at the interface." INDEX { ethSapOprNumber } ::= { ethSapOprTable 1 } EthSapOprEntry ::= SEQUENCE { ethSapOprNumber INTEGER, ethSapOprAlias Alias, ethSapOprConnectorType INTEGER, ethSapOprDataGenerator INTEGER, ethSapOprGenFrames INTEGER, ethSapOprGenFrameSize INTEGER, ethSapOprLoopbackType INTEGER, ethOprControlStats INTEGER, ethStatOprLinkState INTEGER, ethStatOprInFrames Counter, ethStatOprInOctets Counter, ethStatOprInErrors Counter, ethStatOprInDiscards Counter, ethStatOprInBusyDiscards Counter, ethStatOprOutFrames Counter, ethStatOprOutOctets Counter, ethStatOprOutErrors Counter, ethStatOprOutDiscards Counter, ethStatOprOutCSLostFrames Counter, ethStatOprRxGenErrors Counter } ethSapOprNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the service access point by a numerical value. Each service access point is assigned a unique number. The number is assigned by the system." ::= { ethSapOprEntry 1 } ethSapOprAlias OBJECT-TYPE SYNTAX Alias ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the textual name (Alias) of this service access point. Each service access point must have a unique name. Range of Values: 0-16 alphanumeric characters. (Note that the first character must be a letter and spaces are not allowed). Default Value: None" ::= { ethSapOprEntry 2 } ethSapOprConnectorType OBJECT-TYPE SYNTAX INTEGER { auto (1), aui (2), tbaset (3), baset-100 (4) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the connector type used for the hardware port. Options: auto (1): (connector type detected automatically) aui (2): tbaseT (3): 100baseT (4) 100 Mbs Ethernet Default Value: auto" ::= { ethSapOprEntry 3 } ethSapOprDataGenerator OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2), enabled-verify (3), retrigger (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines whether the Data Generator is enabled. The Data Generator is used for testing purposes. Options: disabled (1) enabled (2) enabled-verify(3): The data generator is enabled and it checks what it receives against what it has sent. The result of the test is displayed in ethStatOprRxGenErrors. If this option is selected ethSapOprLoobackType must be set to remote. retrigger (4): The data generator repeats the transmission as specified in ethSapOprGenFrames and ethSapOprGen. Default Value: disabled Configuration Changed: administrative The change cannot be saved." ::= { ethSapOprEntry 4 } ethSapOprGenFrames OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Determines the number of times a frame will be generated (for testing purposes). Frames are generated every 1 msec. If the value is set to zero, then frames will be generated continuously (every 1 msec). If the Data Generator is disabled (using ethSapOprDataGenerator), then the value is ignored. Range of Values: 0 - 255 Default Value: 1" ::= { ethSapOprEntry 5 } ethSapOprGenFrameSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Determines the size of the frames (in bytes) to be generated (for testing purposes). If the Data Generator is disabled, then this value is ignored. Range of Values: 0-1514 bytes Default Value: 512 bytes Configuration Changed: administrative The change cannot be saved." ::= { ethSapOprEntry 6 } ethSapOprLoopbackType OBJECT-TYPE SYNTAX INTEGER { none (1), local (2), remote (3), both (4) } ACCESS read-only STATUS mandatory DESCRIPTION "Determines whether the port performs remote loopback, local loopback or both. Options: none (1): Loopback is disabled. local (2): The Service Access Point associated with the port returns all frames to the originating layer without transmitting them. remote (3): The port transmists back whatever it receives. (This implies that the Service Access Point associated with the port will not permit communications with any upper layer requesting service.) both (4): Both remote and local loopback enabled. Default Value: none (1) Configuration Changed: administrative The change cannot be saved." ::= { ethSapOprEntry 7 } -- gap (4) for future parameters ethOprControlStats OBJECT-TYPE SYNTAX INTEGER { clearSapStats (1) } ACCESS write-only STATUS mandatory DESCRIPTION "Determines whether the statistics for the hardware port will be cleared. When the clearSapStats option is selected all the counters for the port are cleared. Options: clearSapStats (clears statistics for the hardware port)." ::= { ethSapOprEntry 12 } -- gap (1) for future write-only commands ethStatOprLinkState OBJECT-TYPE SYNTAX INTEGER { up (1), down (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies whether the hardware port is available. If there is a problem with the port (e.g. a faulty connection) the value will be down. Options: up (1) down (2) Default Value: None" ::= { ethSapOprEntry 14 } ethStatOprInFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the total number of frames received by this port. The value indicates the activity at this interface. Range of Values: 0 to 4, 294, 967, 295 Default Value: None" ::= { ethSapOprEntry 15 } ethStatOprInOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the total number of octets received by this port. The value indicates the activity at this interface. Range of Values: 0 to 4, 294, 967, 295 Default Value: None" ::= { ethSapOprEntry 16 } ethStatOprInErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the total number of errors received by this port. Errors include overrun errors, non-octet errors, and CRC errors. A high count may indicate a hardware problem. Range of Values: 0 to 4, 294, 967, 295 Default Value: None" ::= { ethSapOprEntry 17 } ethStatOprInDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the total number of frames received and discarded due to errors or other conditions (i.e. busy, lack of receive buffers, frames received while port not bound to an upper layer.) A high count may indicate that the port is not bound to an upper layer. Range of Values: 0 to 4, 294, 967, 295 Default Value: None" ::= { ethSapOprEntry 18 } ethStatOprInBusyDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the total number of frames received and discarded as a result of a lack of receive buffers. A high count may indicate system resources are low. Range of Values: 0 to 4, 294, 967, 295 Default Value: None" ::= { ethSapOprEntry 19 } ethStatOprOutFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the total number of frames transmitted by this port. Range of Values: 0 to 4, 294, 967, 295 Default Value: None" ::= { ethSapOprEntry 20 } ethStatOprOutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the total number of octets transmitted by this port. Range of Values: 0 to 4, 294, 967, 295 Default Value: None" ::= { ethSapOprEntry 21 } ethStatOprOutErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the total number of errors transmitted by this port. The count includes Transmitter Underrun, Carrier sense Lost During Frame Transmission, Attempts Limits Expires, and Late Collisions. A high count may indicate a hardware problem. Range of Values: 0 to 4, 294, 967, 295 Default Value: None" ::= { ethSapOprEntry 22 } ethStatOprOutDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the total number of frames which were unsuccessfully transmitted due to a lack of transmit buffers. Range of Values: 0 to 4, 294, 967, 295 Default Value: None" ::= { ethSapOprEntry 23 } ethStatOprOutCSLostFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the total number of transmitted frames for which the carrier sense lost condition was encountered during transmission. A high count may indicate that the device was unplugged during transmission. Range of Values: 0 to 4, 294, 967, 295 Default Value: None" ::= { ethSapOprEntry 24 } ethStatOprRxGenErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the total number of frames received that contain errors (for a port that has enable-verify set in ethSapOprDataGenerator.) Range of Values: 0 to 4, 294, 967, 295 Default Value: None" ::= { ethSapOprEntry 25 } -- Planned Configuration Table -- The table describing: -- parameters used to configure each Ethernet SAP and its associated -- hardware port. ethSapAdmTable OBJECT-TYPE SYNTAX SEQUENCE OF EthSapAdmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Provides configuration information for each Ethernet service access point and its associated hardware port. Each row (entry) of the table corresponds to a particular service access point." ::= { cxEthIo 2 } ethSapAdmEntry OBJECT-TYPE SYNTAX EthSapAdmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Provides configuration information for a particular Ethernet service access point and its associated hardware port." INDEX { ethSapAdmNumber } ::= { ethSapAdmTable 1 } EthSapAdmEntry ::= SEQUENCE { ethSapAdmNumber INTEGER, ethSapAdmAlias Alias, ethSapAdmConnectorType INTEGER, ethSapAdmDataGenerator INTEGER, ethSapAdmGenFrames INTEGER, ethSapAdmGenFrameSize INTEGER, ethSapAdmLoopbackType INTEGER } ethSapAdmNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the service access point by a number. Each service access point is assigned a unique number. The number is assigned by the system." ::= { ethSapAdmEntry 1 } ethSapAdmAlias OBJECT-TYPE SYNTAX Alias ACCESS read-write STATUS mandatory DESCRIPTION "Determines the textual name (alias) of this service access point. Each service access point is assigned a unique name. Range of Values: 0-16 alphanumeric characters. (Note that the first character must be a letter; spaces are not allowed). Related Parameters: The alias must be the same as the one used in cxCfgIpxPortSubnetworkSAPAlias and cxCfgIpAdEntSubnetworkSAPAlias." ::= { ethSapAdmEntry 2 } ethSapAdmConnectorType OBJECT-TYPE SYNTAX INTEGER { auto (1), aui (2), tbaseT (3), baset-100 (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Identifies the connector type used for the hardware port. Options: auto (1): connector type detected automatically aui (2) tbaseT (3) 100baseT (4) 100 Mbs Ethernet Default Value: auto (1) Configuration Changed: administrative Further action: to activate changed value, click on Action in EMS menu bar, then click on Reset with Save." DEFVAL { auto } ::= { ethSapAdmEntry 3 } ethSapAdmDataGenerator OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2), enabled-verify (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines whether the Data Generator is enabled. The Data Generator is used for testing purposes. Options: disabled (1) enabled.(2) enabled-verify.(3) The data generator is enabled and it checks what it receives against what it has sent. The result of the test is displayed in ethStatAdmrRxGenErrors. If this option is selected, ethSapOprLoobackType must be set to remote. Default Value: disabled (1) Configuration Changed: administrative" DEFVAL { disabled } ::= { ethSapAdmEntry 4 } ethSapAdmGenFrames OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the number of times a frame will be generated (for testing purposes). Frames are generated every 1 msec. If the value is set to zero, then frames will be generated continuously (every 1 msec). If the Data Generator is disabled (using ethSapAdmDataGenerator), then the value is ignored. Range of Values: 0 - 255 Default Value: 1 Configuration Changed: administrative" DEFVAL { 1 } ::= { ethSapAdmEntry 5 } ethSapAdmGenFrameSize OBJECT-TYPE SYNTAX INTEGER (0..1514) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the size of the frames (in bytes) to be generated (for testing purposes). If the Data Generator is disabled, then this value is ignored. Range of Values: 0 -1514 bytes Default Value:512 bytes Configuration Changed: administrative" DEFVAL { 512 } ::= { ethSapAdmEntry 6 } ethSapAdmLoopbackType OBJECT-TYPE SYNTAX INTEGER { none (1), local (2), remote (3), both (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines whether the port performs remote loopback, local loopback or both. Options: none (1): Loopback is disabled. local (2): The Service Access Point associated with the port returns all frames to the originating layer without transmitting them. remote (3): The port transmists back whatever it receives. (This implies that the Service Access Point associated with the port will not permit communications with any upper layer requesting service.) both (4): Both remote and local loopback enabled. Default Value: none (1) Configuration Changed: administrative." DEFVAL { none } ::= { ethSapAdmEntry 7 } END