CXDDS-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString FROM RFC1213-MIB cxDds, SapIndex, Alias FROM CXProduct-SMI; -- Configuration Table -- The table describing: -- parameters used to configure each DDS slot and its associated -- hardware port. ddsSlotTable OBJECT-TYPE SYNTAX SEQUENCE OF DdsSlotEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Identifies the configuration information for a specific DDS access point and its associated hardware port." ::= { cxDds 1 } ddsSlotEntry OBJECT-TYPE SYNTAX DdsSlotEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Identifies the configuration information for a specific DDS access point and its associated hardware port." INDEX { ddsSlotNumber } ::= { ddsSlotTable 1 } DdsSlotEntry ::= SEQUENCE { ddsSlotNumber SapIndex, ddsSlotAlias Alias, ddsSlotRowStatus INTEGER, ddsSlotStatus INTEGER, ddsSlotConfigLineType INTEGER, ddsSlotConfigLineService INTEGER, ddsSlotConfigRemLoop2LocalAddress INTEGER, ddsSlotConfigRemLoop2RemoteAddress INTEGER, ddsSlotConfigLoopback INTEGER, ddsSlotConfigPatternGen INTEGER, ddsSlotDialNumber DisplayString, ddsSlotSoftwareRevision INTEGER, ddsSlotStuffingOption INTEGER, ddsSlotLineQuality INTEGER, ddsSlotLineRelativeReceiveLevelMin INTEGER, ddsSlotLineRelativeReceiveLevelMax INTEGER, ddsSlotLineLoopback INTEGER, ddsSlotResultErtPatternDetect INTEGER, ddsSlotResultPatternGen INTEGER, ddsSlotResultDialing INTEGER, ddsSlotModel INTEGER, ddsSlotRevision INTEGER, ddsSlotEco INTEGER, ddsSlotLineTrap INTEGER, ddsSlotLoopTrap INTEGER } ddsSlotNumber OBJECT-TYPE SYNTAX SapIndex ACCESS read-only STATUS mandatory DESCRIPTION "Identifies a DDS access point by a numerical value. Each DDS access point has a unique value." ::= { ddsSlotEntry 1 } ddsSlotAlias OBJECT-TYPE SYNTAX Alias ACCESS read-write STATUS mandatory DESCRIPTION "Assigns a textual name to the DDS access point. Each access point requires a unique name. You may not assign the same name twice. Default Value: none Range of Values: up to 12 alphanumeric characters, the first must be a letter. Configuration Changed: operative" ::= { ddsSlotEntry 2 } ddsSlotRowStatus OBJECT-TYPE SYNTAX INTEGER { invalid (1), valid (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the status of the objects in a row. Default Value: valid Options: invalid (1): row is flagged, after next reset the values will be disabled and the row will be deleted from the table valid (2): values are enabled Configuration Changed: administrative" ::= { ddsSlotEntry 3 } ddsSlotStatus OBJECT-TYPE SYNTAX INTEGER { dds-not-present (1), dds-present (2), dds-present-failed (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the status of the DDS option card as present, not present or present but failed. Default Value: none Options: dds-not-present (1) dds-present (2) dds-present-failed (3)" ::= { ddsSlotEntry 4 } ddsSlotConfigLineType OBJECT-TYPE SYNTAX INTEGER { telco-point-to-point (1), telco-multipt (2), ldm-timing-slave (3), ldm-timing-master (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Assigns the DDS line configuration. Default Value: telco-point-to-point (1) Options: telco-point-to-point (1) telco-multipoint (2) idm-timing-slave (3) idm-timing-master (4) Configuration Changed: operative" DEFVAL { telco-point-to-point } ::= { ddsSlotEntry 5 } ddsSlotConfigLineService OBJECT-TYPE SYNTAX INTEGER { clear-channel-64K (1), switched-56K (2), dds-56K (3), dds-19200 (4), dds-9600 (5), dds-4800 (6), dds-2400 (7) } ACCESS read-write STATUS mandatory DESCRIPTION "Assigns the DDS line service type. Default Value: dds-56K (2) Range of Values: clear-channel-64K (1) switched-56K (2) dds-56K (3) dds-19200 (4) dds-9600 (5) dds-4800 (6) dds-2400 (7) dds-1200 (8) Configuration Changed: operative" DEFVAL { dds-56K } ::= { ddsSlotEntry 6 } ddsSlotConfigLoopback OBJECT-TYPE SYNTAX INTEGER { no-loopback (1), dte-loopback (2), loop2 (3), loop3 (4), loop4 (5), remote-loop2 (6) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the DDS loopback type. Default Value: no-loopback (1) Range of Values: no-loopback (1) dte-loopback (2) loop2 (3), loop3 (4), loop4 (5) remote-loop2 (6) Configuration Changed: operative" DEFVAL { no-loopback } ::= { ddsSlotEntry 7 } ddsSlotConfigRemLoop2LocalAddress OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the local address for V.54 remote loop2. Default Value: none Range of Values: 0 to 255 The 34 valid V.54 hex addresses include: 0x01, 0x03, 0x05, 0x07, 0x09, 0x0B, 0x0D, 0x0F, 0x11, 0x13, 0x15, 0x17, 0x19, 0x1B, 0x1D, 0x1F, 0x25, 0x27, 0x2B, 0x2D, 0x2F, 0x33, 0x35, 0x37, 0x3B, 0x3D, 0x3F, 0x55, 0x57, 0x5B, 0x5F, 0x6F, 0x77, 0x7F Configuration Changed: operative" ::= { ddsSlotEntry 8 } ddsSlotConfigRemLoop2RemoteAddress OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the remote address for V.54 remote loop2. Range of Values: 0 to 255 Default Value: none Configuration Changed: operative" ::= { ddsSlotEntry 9 } ddsSlotConfigPatternGen OBJECT-TYPE SYNTAX INTEGER { no-pattern (1), pattern-511 (2), pattern-511-with-errors (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the type of pattern generated. Range of Values: no-pattern (1) pattern-511 (2) pattern-511-with-errors (3) Default Value: no-pattern (1) Configuration Changed: operative" DEFVAL { no-pattern } ::= { ddsSlotEntry 10 } ddsSlotDialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..11)) ACCESS read-write STATUS mandatory DESCRIPTION "Assigns the dial number for switched56 applications. Default Value: none Range of Values: 12 character octet string Configuration Changed: operative" ::= { ddsSlotEntry 11 } ddsSlotSoftwareRevision OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the DDS firmware revision as an integer value from 0 to 255. Default Value: none Range of Values: 0-255" ::= { ddsSlotEntry 12 } ddsSlotStuffingOption OBJECT-TYPE SYNTAX INTEGER { ccc-installed (1), ccc-not-installed (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies whether the clear channel chip (ccc) option (for 64K clear channel) is installed. Default Value: none Options: ccc-installed (1) ccc-not-installed (2)" ::= { ddsSlotEntry 13 } ddsSlotLineQuality OBJECT-TYPE SYNTAX INTEGER { link (1), no-link (2), network-error-oos (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies whether the link is up, if no link exists or if a network error (OOS - out of service) has occurred. Default Value: none Options: link (1) no-link (2) network-error-oos (3)" ::= { ddsSlotEntry 14 } ddsSlotLineRelativeReceiveLevelMin OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the minimum relative receive line level. Default Value: none Range of Values: 0-255" ::= { ddsSlotEntry 15 } ddsSlotLineRelativeReceiveLevelMax OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the maximum relative receive line level. Default Value: none Range of Values: 0-255" ::= { ddsSlotEntry 16 } ddsSlotLineLoopback OBJECT-TYPE SYNTAX INTEGER { none (1), csu-loopback (2), dsu-loopback (3), dte-loopback (4), loop2 (5), loop3 (6), loop4 (7), remote-loop2 (8) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the loopback status of the line. Options: none (1) csu-loopback (2) dsu-loopback (3) dte-loopback (4) loop2 (5) loop3 (6) loop4 (7) remote-loop2 (8) Default Value: none (1) " ::= { ddsSlotEntry 17 } ddsSlotResultErtPatternDetect OBJECT-TYPE SYNTAX INTEGER { not-receiving-pattern (1), receiving-pattern (2), receiving-patt-with-errors (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the reception of the 511 bit pattern or not. Options: not-receiving-pattern (1) receiving-pattern (2) receiving-patt-with-errors (3) Default Value: none " ::= { ddsSlotEntry 18 } ddsSlotResultPatternGen OBJECT-TYPE SYNTAX INTEGER { no-pattern (1), ert-pattern (2), ert-with-errors (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Identifies what type of pattern the DDS is generating on the line. Options: no-pattern (1) ert-pattern (2) ert-with-errors (3) Default: none " ::= { ddsSlotEntry 19 } ddsSlotResultDialing OBJECT-TYPE SYNTAX INTEGER { dialing-idle (1), dialing-now (2), connection-made (3), err-no-num-from-host (4), err-no-link (5), err-no-rx-idle (6), err-no-wink (7), err-invalid-wink (8), err-no-answer (9) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the dialing result codes for switched56 service as: dialing, connection made, the connection is not switched56, that a number has not been supplied by the host, no link available, no wink available, wink invalid or no answer. Options: dialing-idle (1) dialing-now (2) connection-made (3) err-no-num-from-host (4) err-no-link (5) err-no-rx-idle (6) err-no-wink (7) err-invalid-wink (8) err-no-answer (9) Default Value: none " ::= { ddsSlotEntry 20 } ddsSlotModel OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the Printed Circuit Board (PCB) model number . Range of Values: 0-7 Default: none" ::= { ddsSlotEntry 21 } ddsSlotRevision OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the PCB revision level. Range of Values: 0-15 Default Value: none" ::= { ddsSlotEntry 22 } ddsSlotEco OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the PCB Engineering Change Order (ECO) level. Range of Values: 0-15 Default Value: none " ::= { ddsSlotEntry 23 } ddsSlotLineTrap OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the status of the line trap. Options: disabled (1) enabled (2) Default Value: disabled (1) Configuration Changed: operative" DEFVAL { disabled } ::= { ddsSlotEntry 24 } ddsSlotLoopTrap OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the status of the loopback change trap. Range of Values: disabled (1) enabled (2) Default Value: disabled (1) Configuration Changed: operative" DEFVAL { disabled } ::= { ddsSlotEntry 25 } -- Service access point related traps ddsSlotLineStatusChange TRAP-TYPE ENTERPRISE cxDds VARIABLES { ddsSlotNumber, ddsSlotLineQuality } DESCRIPTION "Indicates that an alarm has occurred. The line quality currently in use at the DDS access point has changed state to any of the states defined in object ddsSlotLineQuality." ::= 1 ddsSlotLoopStatusChange TRAP-TYPE ENTERPRISE cxDds VARIABLES { ddsSlotNumber, ddsSlotLineLoopback } DESCRIPTION "Indicates an alarm status has occurred. The loopback status currently in use at the DDS access point has changed state to any of the states defined in object ddsSlotLineLoopback." ::= 2 END