CXBRI-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 cxBri FROM CXProduct-SMI; -- ISDN Basic Rate Interface Built-In Self Test Configuration Table -- The table describing: -- statistics available for monitoring test results of an ISDN U or -- S/T-Interface daughter card briTable OBJECT-TYPE SYNTAX SEQUENCE OF BriEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing test results of an ISDN U or S/T-Interface daughter card." ::= { cxBri 10 } briEntry OBJECT-TYPE SYNTAX BriEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The parameters for a specific ISDN U or S/T-Interface daughter card." INDEX { briSlotNumberIndex } ::= { briTable 1 } BriEntry ::= SEQUENCE { -- Parameters briSlotNumberIndex INTEGER, -- Control -- Status briIoRegTest INTEGER, briIoLedsTest INTEGER, briImpRegTest INTEGER, briImpComTestPollResult INTEGER, briTxcvrRegTest INTEGER, briTxcvrComTestPollResult INTEGER -- Statistics } briSlotNumberIndex OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the row containing objects for monitoring an I/O card in the CX900 or CX950. Range of Values: 1-6 for CX900 (slot) 1-8 for CX950 (slot) Default Value: none" ::= { briEntry 1 } briIoRegTest OBJECT-TYPE SYNTAX INTEGER { failed (1), passed (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the result of the ISDN U or S/T-interface I/O register test. Options: failed (1): register test failed passed (2): register test passed Default Value: passed (2)" ::= { briEntry 20 } briIoLedsTest OBJECT-TYPE SYNTAX INTEGER { initializationFailed (1), initializationPassed (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the result of the ISDN U or S/T-interface Integrated Multiprotocol Processor (IMP) LEDs test. Options: initializationFailed (1): IMP initialization failed initializationPassed (2): IMP initialization passed Default Value: initializationPassed" ::= { briEntry 21 } briImpRegTest OBJECT-TYPE SYNTAX INTEGER { initializationFailed (1), failed (2), passed (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the result of the ISDN U or S/T-interface Integrated Multiprotocol Processor (IMP) register test. Options: initializationFailed (1): IMP initialization failed failed (2): IMP register test failed passed (3): IMP register test passed Default Value: passed (3)" ::= { briEntry 22 } briImpComTestPollResult OBJECT-TYPE SYNTAX INTEGER { initializationFailed (1), failed (2), passed (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the result of the ISDN U or S/T-interface IMP internal communication test while in polling mode. Options: initializationFailed (1): IMP initialization failed failed (2): IMP communication test failed in polling mode passed (3): IMP communication test passed in polling mode Default Value: passed (3)" ::= { briEntry 23 } briTxcvrRegTest OBJECT-TYPE SYNTAX INTEGER { initializationFailed (1), failed (2), passed (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the result of the ISDN U or S/T-interface transceiver register test. Options: initializationFailed (1): IMP initialization test failed failed (2): transceiver register test failed passed (3): transceiver register test passed Default Value: passed (3)" ::= { briEntry 24 } briTxcvrComTestPollResult OBJECT-TYPE SYNTAX INTEGER { initializationFailed (1), failed (2), passed (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the result of the ISDN U or S/T-interface transceiver internal communication test while in polling mode. Options: initializationFailed (1): IMP initialization failed failed (2): transceiver communication test failed in polling mode passed (3): transceiver communication test passed in polling mode Default Value: passed (3)" ::= { briEntry 25 } END