BAS-ALIAS-SNMP-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, TimeTicks, Counter32 FROM SNMPv2-SMI DisplayString, TimeStamp FROM SNMPv2-TC basAliasSnmp, BasChassisId, BasSlotId, BasInterfaceId, BasLogicalPortId FROM BAS-MIB; basAliasSnmpMib MODULE-IDENTITY LAST-UPDATED "9810081200Z" ORGANIZATION "Broadband Access Systems" CONTACT-INFO " Tech Support Broadband Access Systems 201 Forest Street Marlboro, MA 01752 U.S.A. 508-485-8200 support@basystems.com" DESCRIPTION "This MIB module defines the Alias SNMP MIB objects for a Broadband Access System Cluster." ::= { basAliasSnmp 1 } basSnmp OBJECT IDENTIFIER ::= { basAliasSnmpMib 1 } basSystem OBJECT IDENTIFIER ::= { basAliasSnmpMib 2 } -- the System group -- -- a collection of objects common to all managed systems. basSysTable OBJECT-TYPE SYNTAX SEQUENCE OF BasSysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Per Chassis Stack MIB-II system objects." ::= { basSystem 1 } basSysEntry OBJECT-TYPE SYNTAX BasSysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "MIB-II system objects for a Chassis Stack." INDEX { basSysChassis, basSysSlot, basSysIf, basSysLPort } ::= { basSysTable 1 } BasSysEntry ::= SEQUENCE { basSysDescr DisplayString, basSysObjectID OBJECT IDENTIFIER, basSysUpTime TimeTicks, basSysContact DisplayString, basSysName DisplayString, basSysLocation DisplayString, basSysServices INTEGER, basSysORLastChange TimeStamp, basSysChassis BasChassisId, basSysSlot BasSlotId, basSysIf BasInterfaceId, basSysLPort BasLogicalPortId } basSysDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software." ::= { basSysEntry 1 } basSysObjectID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining `what kind of box' is being managed. For example, if vendor `Flintstones, Inc.' was assigned the subtree 1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'." ::= { basSysEntry 2 } basSysUpTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The time (in hundredths of a second) since the network management portion of the system was last re-initialized." ::= { basSysEntry 3 } basSysContact OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string." ::= { basSysEntry 4 } basSysName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string." ::= { basSysEntry 5 } basSysLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string." ::= { basSysEntry 6 } basSysServices OBJECT-TYPE SYNTAX INTEGER (0..127) MAX-ACCESS read-only STATUS current DESCRIPTION "A value which indicates the set of services that this entity may potentially offers. The value is a sum. This sum initially takes the value zero, Then, for each layer, L, in the range 1 through 7, that this node performs transactions for, 2 raised to (L - 1) is added to the sum. For example, a node which performs only routing functions would have a value of 4 (2^(3-1)). In contrast, a node which is a host offering application services would have a value of 72 (2^(4-1) + 2^(7-1)). Note that in the context of the Internet suite of protocols, values should be calculated accordingly: layer functionality 1 physical (e.g., repeaters) 2 datalink/subnetwork (e.g., bridges) 3 internet (e.g., supports the IP) 4 end-to-end (e.g., supports the TCP) 7 applications (e.g., supports the SMTP) For systems including OSI protocols, layers 5 and 6 may also be counted." ::= { basSysEntry 7 } basSysORLastChange OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time of the most recent change in state or value of any instance of sysORID." ::= { basSysEntry 8 } basSysChassis OBJECT-TYPE SYNTAX BasChassisId MAX-ACCESS not-accessible STATUS current DESCRIPTION "The BAS Chassis ID of this card." ::= { basSysEntry 9} basSysSlot OBJECT-TYPE SYNTAX BasSlotId MAX-ACCESS not-accessible STATUS current DESCRIPTION "The BAS Slot ID of this card." ::= { basSysEntry 10 } basSysIf OBJECT-TYPE SYNTAX BasInterfaceId MAX-ACCESS not-accessible STATUS current DESCRIPTION "The BAS interface ID of this card." ::= { basSysEntry 11 } basSysLPort OBJECT-TYPE SYNTAX BasLogicalPortId MAX-ACCESS not-accessible STATUS current DESCRIPTION "The BAS logical port ID of this card." ::= { basSysEntry 12 } basSysORTable OBJECT-TYPE SYNTAX SEQUENCE OF BasSysOREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The (conceptual) table listing the capabilities of the local SNMPv2 entity acting in an agent role with respect to various MIB modules. SNMPv2 entities having dynamically- configurable support of MIB modules will have a dynamically-varying number of conceptual rows." ::= { basSystem 2 } basSysOREntry OBJECT-TYPE SYNTAX BasSysOREntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (conceptual row) in the basSysORTable." INDEX { basSysORChassis, basSysORSlot, basSysORIf, basSysORLPort, basSysORIndex } ::= { basSysORTable 1 } BasSysOREntry ::= SEQUENCE { basSysORIndex INTEGER, basSysORID OBJECT IDENTIFIER, basSysORDescr DisplayString, basSysORUpTime TimeStamp, basSysORChassis BasChassisId, basSysORSlot BasSlotId, basSysORIf BasInterfaceId, basSysORLPort BasLogicalPortId } basSysORIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auxiliary variable used for identifying instances of the columnar objects in the basSysORTable." ::= { basSysOREntry 1 } basSysORID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "An authoritative identification of a capabilities statement with respect to various MIB modules supported by the local SNMPv2 entity acting in an agent role." ::= { basSysOREntry 2 } basSysORDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of the capabilities identified by the corresponding instance of basSysORID." ::= { basSysOREntry 3 } basSysORUpTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of basSysUpTime at the time this conceptual row was last instanciated." ::= { basSysOREntry 4 } basSysORChassis OBJECT-TYPE SYNTAX BasChassisId MAX-ACCESS not-accessible STATUS current DESCRIPTION "The BAS Chassis ID of this card." ::= { basSysOREntry 5} basSysORSlot OBJECT-TYPE SYNTAX BasSlotId MAX-ACCESS not-accessible STATUS current DESCRIPTION "The BAS Slot ID of this card." ::= { basSysOREntry 6 } basSysORIf OBJECT-TYPE SYNTAX BasInterfaceId MAX-ACCESS not-accessible STATUS current DESCRIPTION "The BAS interface ID of this card." ::= { basSysOREntry 7 } basSysORLPort OBJECT-TYPE SYNTAX BasLogicalPortId MAX-ACCESS not-accessible STATUS current DESCRIPTION "The BAS logical port ID of this card." ::= { basSysOREntry 8 } -- the SNMP group -- -- a collection of objects providing basic instrumentation and -- control of an SNMP entity. basSnmpTable OBJECT-TYPE SYNTAX SEQUENCE OF BasSnmpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Per Chassis Stack MIB-II system objects." ::= { basSnmp 1 } basSnmpEntry OBJECT-TYPE SYNTAX BasSnmpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "MIB-II system objects for a Chassis Stack." INDEX { basSnmpChassis, basSnmpSlot, basSnmpIf, basSnmpLPort } ::= { basSnmpTable 1 } BasSnmpEntry ::= SEQUENCE { basSnmpInPkts Counter32, basSnmpInBadVersions Counter32, basSnmpInBadCommunityNames Counter32, basSnmpInBadCommunityUses Counter32, basSnmpInASNParseErrs Counter32, basSnmpEnableAuthenTraps INTEGER, basSnmpSilentDrops Counter32, basSnmpProxyDrops Counter32, basSnmpChassis BasChassisId, basSnmpSlot BasSlotId, basSnmpIf BasInterfaceId, basSnmpLPort BasLogicalPortId } basSnmpInPkts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of messages delivered to the SNMP entity from the transport service." ::= { basSnmpEntry 1 } basSnmpInBadVersions OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of SNMP messages which were delivered to the SNMP entity and were for an unsupported SNMP version." ::= { basSnmpEntry 3 } basSnmpInBadCommunityNames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of SNMP messages delivered to the SNMP entity which used a SNMP community name not known to said entity." ::= { basSnmpEntry 4 } basSnmpInBadCommunityUses OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of SNMP messages delivered to the SNMP entity which represented an SNMP operation which was not allowed by the SNMP community named in the message." ::= { basSnmpEntry 5 } basSnmpInASNParseErrs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of ASN.1 or BER errors encountered by the SNMP entity when decoding received SNMP messages." ::= { basSnmpEntry 6 } basSnmpEnableAuthenTraps OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the SNMP entity is permitted to generate authenticationFailure traps. The value of this object overrides any configuration information; as such, it provides a means whereby all authenticationFailure traps may be disabled. Note that it is strongly recommended that this object be stored in non-volatile memory so that it remains constant across re-initializations of the network management system." ::= { basSnmpEntry 30 } basSnmpSilentDrops OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of GetRequest-PDUs, GetNextRequest-PDUs, GetBulkRequest-PDUs, SetRequest-PDUs, and InformRequest-PDUs delivered to the SNMP entity which were silently dropped because the size of a reply containing an alternate Response-PDU with an empty variable-bindings field was greater than either a local constraint or the maximum message size associated with the originator of the request." ::= { basSnmpEntry 31 } basSnmpProxyDrops OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of GetRequest-PDUs, GetNextRequest-PDUs, GetBulkRequest-PDUs, SetRequest-PDUs, and InformRequest-PDUs delivered to the SNMP entity which were silently dropped because the transmission of the (possibly translated) message to a proxy target failed in a manner (other than a time-out) such that no Response-PDU could be returned." ::= { basSnmpEntry 32 } basSnmpChassis OBJECT-TYPE SYNTAX BasChassisId MAX-ACCESS not-accessible STATUS current DESCRIPTION "The BAS Chassis ID of this card." ::= { basSnmpEntry 33 } basSnmpSlot OBJECT-TYPE SYNTAX BasSlotId MAX-ACCESS not-accessible STATUS current DESCRIPTION "The BAS Slot ID of this card." ::= { basSnmpEntry 34 } basSnmpIf OBJECT-TYPE SYNTAX BasInterfaceId MAX-ACCESS not-accessible STATUS current DESCRIPTION "The BAS interface ID of this card." ::= { basSnmpEntry 35 } basSnmpLPort OBJECT-TYPE SYNTAX BasLogicalPortId MAX-ACCESS not-accessible STATUS current DESCRIPTION "The BAS logical port ID of this card." ::= { basSnmpEntry 36 } END