-- SDSL Enterprise Mib -- -- Ascend Communications, Inc -- 1275 Harbor Bay Pkwy -- Alameda, CA 94502 -- +1 510 769 6001 -- info@ascend.com -- -- Copyright (c) 1993-1995 Ascend Communications, Inc. -- All rights reserved. -- -- CVS ID: $Id: sdsl.mib,v 29.4.66.2 2000/01/28 18:30:16 jjablons Exp $ -- -- 06 Dec 96: Initial release -- Ascend wanTypeSdsl group -- -- This group contains MIB variables used to manage the SDSL -- interface -- SDSL interface status -- -- The below entries contain interface status information. The slot -- number and interface are identified via that sdslSlotIndex and -- sdslLineIndex parameters. -- ASCEND-SDSL-MIB DEFINITIONS ::= BEGIN IMPORTS wanTypeSdsl FROM ASCEND-WAN-MIB OBJECT-TYPE FROM RFC-1212; sdslLineStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SdslLineStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SDSL status parameters." ::= { wanTypeSdsl 1 } sdslLineStatusEntry OBJECT-TYPE SYNTAX SdslLineStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An interface status entry containing objects to describe the interface." INDEX { sdslStatusIfEntryIndex } ::= { sdslLineStatusTable 1 } SdslLineStatusEntry ::= SEQUENCE { sdslStatusIfEntryIndex INTEGER, sdslStatusShelfIndex INTEGER, sdslStatusSlotIndex INTEGER, sdslStatusLineIndex INTEGER, sdslStatusUnitType INTEGER, sdslStatusLineState INTEGER, sdslStatusUpRate INTEGER, sdslStatusDownRate INTEGER, sdslStatusVendorId INTEGER, sdslStatusMajorFirmWareVer INTEGER, sdslStatusMinorFirmWareVer INTEGER, sdslStatusHardWareVer INTEGER, sdslStatusLineRate INTEGER } sdslStatusIfEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Interface group index assigned to this port." ::= { sdslLineStatusEntry 1 } sdslStatusShelfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "TNT's SDSL modules Shelf ID." ::= { sdslLineStatusEntry 2 } sdslStatusSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "TNT's SDSL modules Slot ID." ::= { sdslLineStatusEntry 3 } sdslStatusLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SDSL modules line ID." ::= { sdslLineStatusEntry 4 } sdslStatusUnitType OBJECT-TYPE SYNTAX INTEGER { other( 1 ), -- none of the following coe( 2 ), -- Central Office Equipment. cpe( 3 ) -- Customer Premises -- Equipment. } ACCESS read-only STATUS mandatory DESCRIPTION "Unit type defines if the unit is operating either as a Central Office Equipment (COE) or Customer Premiss equipment (CPE)." ::= { sdslLineStatusEntry 5 } sdslStatusLineState OBJECT-TYPE SYNTAX INTEGER { other( 1 ), -- none of the following configure( 2 ), -- Interface is in -- Configuration state. deactivate( 3 ), -- Port is down. Deactive -- has been issued. deactive-lost( 4 ), -- Waiting for LOS or LOST -- indication. start-up( 5 ), -- Interface is in start-up -- mode. pend-port-up( 6 ), up( 7 ), -- Interface is in UP state, and -- ready to transfer data. pend-deactivate( 8 ),-- Interface may transition -- from UP to DOWN state. out-of-service( 9 ) -- Interface is placed OOS. } ACCESS read-only STATUS mandatory DESCRIPTION "Interface state describes the current ports operating state. States are: Config, Pend Down, Up, Down, Start-up, or N/A." ::= { sdslLineStatusEntry 6 } sdslStatusUpRate OBJECT-TYPE SYNTAX INTEGER{ m2320000(2320000), m1568000(1568000), m1552000(1552000), m1536000(1536000), m1168000(1168000), m1152000(1152000), m1040000(1040000), k784000(784000), k768000(768000), k528000(528000), k416000(416000), k400000(400000), k384000(384000), k272000(272000), k208000(208000), k192000(192000), k160000(160000), k144000(144000) } ACCESS read-write STATUS deprecated -- Deprecated starting from TAOS 8.0 DESCRIPTION "The current up stream (cpe to coe) rate The object dslStatusUpRate is deprecated. To set line rate the object sdslConfigLineRate of the new sdslLineConfigTable should be used." ::= { sdslLineStatusEntry 7 } sdslStatusDownRate OBJECT-TYPE SYNTAX INTEGER{ m2320000(2320000), m1568000(1568000), m1552000(1552000), m1536000(1536000), m1168000(1168000), m1152000(1152000), m1040000(1040000), k784000(784000), k768000(768000), k528000(528000), k416000(416000), k400000(400000), k384000(384000), k272000(272000), k208000(208000), k192000(192000), k160000(160000), k144000(144000) } ACCESS read-write STATUS deprecated -- Deprecated starting from TAOS 8.0 DESCRIPTION "The current down stream (coe to cpe) rate The object dslStatusDownRate is deprecated. To set line rate the object sdslConfigLineRate of the new sdslLineConfigTable should be used." ::= { sdslLineStatusEntry 8 } sdslStatusVendorId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Vendor identification." ::= { sdslLineStatusEntry 9 } sdslStatusMajorFirmWareVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Major firmware version." ::= { sdslLineStatusEntry 10 } sdslStatusMinorFirmWareVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minor firmware version." ::= { sdslLineStatusEntry 11 } sdslStatusHardWareVer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Hardware version." ::= { sdslLineStatusEntry 12 } sdslStatusLineRate OBJECT-TYPE SYNTAX INTEGER{ unknown(1), m2320000(2320000), m1568000(1568000), m1552000(1552000), m1536000(1536000), m1168000(1168000), m1152000(1152000), m1040000(1040000), k784000(784000), k768000(768000), k528000(528000), k416000(416000), k400000(400000), k384000(384000), k272000(272000), k208000(208000), k192000(192000), k160000(160000), k144000(144000) } ACCESS read-only STATUS mandatory DESCRIPTION "The current line rate" ::= { sdslLineStatusEntry 13 } sdslLineStatisticTable OBJECT-TYPE SYNTAX SEQUENCE OF SdslLineStatisticEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SDSL statistical parameters." ::= { wanTypeSdsl 2 } sdslLineStatisticEntry OBJECT-TYPE SYNTAX SdslLineStatisticEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An interface statistical entry containing objects to describe the interface." INDEX { sdslStatIfEntryIndex } ::= { sdslLineStatisticTable 1 } SdslLineStatisticEntry ::= SEQUENCE { sdslStatIfEntryIndex INTEGER, sdslStatShelfIndex INTEGER, sdslStatSlotIndex INTEGER, sdslStatLineIndex INTEGER, sdslStatConnUpDays INTEGER, sdslStatConnUpHours INTEGER, sdslStatConnUpMinutes INTEGER, sdslStatRxSignalPresent INTEGER, sdslStatLineQualityDb INTEGER, sdslStatUpDwnCntr INTEGER, sdslStatLineSelfTest INTEGER, sdslStatBertTimer INTEGER, sdslStatBertEna INTEGER, sdslStatBertState INTEGER, sdslStatBertErrorCounter INTEGER } sdslStatIfEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The interface groups interface index is used to index into this table." ::= { sdslLineStatisticEntry 1 } sdslStatShelfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SDSL modules Shelf ID." ::= { sdslLineStatisticEntry 2 } sdslStatSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SDSL modules Slot ID." ::= { sdslLineStatisticEntry 3 } sdslStatLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SDSL modules interface ID." ::= { sdslLineStatisticEntry 4 } sdslStatConnUpDays OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Connection up day count." ::= { sdslLineStatisticEntry 5 } sdslStatConnUpHours OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Connection Up 24 hour count." ::= { sdslLineStatisticEntry 6 } sdslStatConnUpMinutes OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Connection up minute count." ::= { sdslLineStatisticEntry 7 } sdslStatRxSignalPresent OBJECT-TYPE SYNTAX INTEGER { no( 1 ), -- LOS of signal detected. yes( 2 ) -- Receive signal present. } ACCESS read-only STATUS mandatory DESCRIPTION "Receive signal present detection." ::= { sdslLineStatisticEntry 8 } sdslStatLineQualityDb OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Lines noise margin. Reliable data will transfer with a reading of -5db or greater." ::= { sdslLineStatisticEntry 9 } sdslStatUpDwnCntr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Line Up Down counter value displays the number of times the interface transitions from a down to up state." ::= { sdslLineStatisticEntry 10 } sdslStatLineSelfTest OBJECT-TYPE SYNTAX INTEGER { other( 4 ), selfTestFailed( 1 ), localLoopBackFailed( 2 ), passed( 3 ) } ACCESS read-only STATUS mandatory DESCRIPTION "Line hardware self test results (Passed or Failed)." ::= { sdslLineStatisticEntry 11 } sdslStatBertTimer OBJECT-TYPE SYNTAX INTEGER { one-minute(1), two-minutes(2), three-minutes(3), four-minutes(4), five-minutes(5), ten-minutes(6), fifteen-minutes(7), twenty-minutes(8), thirty-minutes(9) } ACCESS read-write STATUS mandatory DESCRIPTION "BER test duration configuration. The BER test lasts for the duration of this timer." ::= { sdslLineStatisticEntry 12 } sdslStatBertEna OBJECT-TYPE SYNTAX INTEGER { no( 1 ), yes( 2 ) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/disable of the BER test. If nodes are connected, then the BER test is ran between the units. If this node is not connected to a remote node, then the interface is placed into analog loopback and the BER test is started." ::= { sdslLineStatisticEntry 13 } sdslStatBertState OBJECT-TYPE SYNTAX INTEGER { active(1), stopped(2), start-up(3), waiting(4), pend-active(5), bert-los(6) } ACCESS read-only STATUS mandatory DESCRIPTION "BER test states. When this node is not connected to another node, the test is disabled. When two nodes are connected then the BER test waits for the other node to start it's BER test and then starts collecting bit errors immediately." ::= { sdslLineStatisticEntry 14 } sdslStatBertErrorCounter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "BER test bit error counter." ::= { sdslLineStatisticEntry 15 } -- Line Configuration Table -- Supported on MAX20, DSLS15, DSLS50 platforms starting from TAOS 8.0 sdslLineConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SdslLineConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SDSL status parameters." ::= { wanTypeSdsl 3 } sdslLineConfigEntry OBJECT-TYPE SYNTAX SdslLineConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An interface status entry containing objects to describe the interface." INDEX { sdslConfigIfEntryIndex } ::= { sdslLineConfigTable 1 } SdslLineConfigEntry ::= SEQUENCE { sdslConfigIfEntryIndex INTEGER, sdslConfigShelfIndex INTEGER, sdslConfigSlotIndex INTEGER, sdslConfigLineIndex INTEGER, sdslConfigLineRate INTEGER } sdslConfigIfEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Interface group index assigned to this port." ::= { sdslLineConfigEntry 1 } sdslConfigShelfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "TNT's SDSL modules Shelf ID." ::= { sdslLineConfigEntry 2 } sdslConfigSlotIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "TNT's SDSL modules Slot ID." ::= { sdslLineConfigEntry 3 } sdslConfigLineIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SDSL modules line ID." ::= { sdslLineConfigEntry 4 } sdslConfigLineRate OBJECT-TYPE SYNTAX INTEGER{ unknown(1), m2320000(2320000), m1568000(1568000), m1552000(1552000), m1536000(1536000), m1168000(1168000), m1152000(1152000), m1040000(1040000), k784000(784000), k768000(768000), k528000(528000), k416000(416000), k400000(400000), k384000(384000), k272000(272000), k208000(208000), k192000(192000), k160000(160000), k144000(144000) } ACCESS read-write STATUS mandatory DESCRIPTION "The current line rate" ::= { sdslLineConfigEntry 5 } END