-- Ascend mibuser MIB -- -- Ascend Communications, Inc -- 1275 Harbor Bay Pkwy -- Alameda, CA 94502 -- +1 510 769 6001 -- info@ascend.com -- -- Copyright (c) 1993-1999 Ascend Communications, Inc. -- All rights reserved. -- -- Do not edit this file directly. -- It is generated automatically by mibgen for use with -- TAOS version 10.0.1 or newer. -- ASCEND-MIBUSER-MIB DEFINITIONS ::= BEGIN IMPORTS configuration FROM ASCEND-MIB IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- If any of the MIB compilers have problems with the DisplayString -- or PhysAddress, uncomment the next two lines. DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING mibuserProfile OBJECT IDENTIFIER ::= { configuration 134} -- The mibuserProfile table -- -- This table contains parameters for the mibuserProfile profile -- mibuserProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF MibuserProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of mibuserProfile profile entries." ::= { mibuserProfile 1 } mibuserProfileEntry OBJECT-TYPE SYNTAX MibuserProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A mibuserProfile entry containing objects that maps to the parameters of mibuserProfile profile." INDEX { userProfile-Name } ::= { mibuserProfileTable 1 } MibuserProfileEntry ::= SEQUENCE { userProfile-Name DisplayString, userProfile-Password DisplayString, userProfile-ActiveEnabled INTEGER, userProfile-AllowTermserv INTEGER, userProfile-AllowSystem INTEGER, userProfile-AllowDiagnostic INTEGER, userProfile-AllowUpdate INTEGER, userProfile-AllowPassword INTEGER, userProfile-AllowCode INTEGER, userProfile-IdleLogout INTEGER, userProfile-Prompt DisplayString, userProfile-DefaultStatus INTEGER, userProfile-TopStatus INTEGER, userProfile-BottomStatus INTEGER, userProfile-LeftStatus INTEGER, userProfile-ScreenWidth INTEGER, userProfile-ScreenLength INTEGER, userProfile-StatusLength INTEGER, userProfile-UseScrollRegions INTEGER, userProfile-LogDisplayLevel INTEGER, userProfile-Action-o INTEGER } userProfile-Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The name of the host that is asking for validation." ::= { mibuserProfileEntry 1 } userProfile-Password OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The password of the host that is asking for validation." ::= { mibuserProfileEntry 2 } userProfile-ActiveEnabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if this user account is enabled for use." ::= { mibuserProfileEntry 3 } userProfile-AllowTermserv OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if this user may use teminal server commands." ::= { mibuserProfileEntry 4 } userProfile-AllowSystem OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if this user may use system commands." ::= { mibuserProfileEntry 5 } userProfile-AllowDiagnostic OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if this user may use diagnostic commands." ::= { mibuserProfileEntry 6 } userProfile-AllowUpdate OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if this user may use update commands." ::= { mibuserProfileEntry 7 } userProfile-AllowPassword OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if this user may user may view password fields." ::= { mibuserProfileEntry 8 } userProfile-AllowCode OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if this user may upload code the the unit." ::= { mibuserProfileEntry 9 } userProfile-IdleLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "When non-zero, the user will be logged out after this many minutes with no keyboard activity." ::= { mibuserProfileEntry 10 } userProfile-Prompt OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The prompt displayed to the user. The value '*' is substituted with the user's name." ::= { mibuserProfileEntry 11 } userProfile-DefaultStatus OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "When TRUE, the status screen is displayed by default." ::= { mibuserProfileEntry 12 } userProfile-TopStatus OBJECT-TYPE SYNTAX INTEGER { generalInfo (1), logWindow (2), lineStatus (3), atmvccStatus (4) } ACCESS read-write STATUS mandatory DESCRIPTION "The default content of the upper configurable status window." ::= { mibuserProfileEntry 13 } userProfile-BottomStatus OBJECT-TYPE SYNTAX INTEGER { generalInfo (1), logWindow (2), lineStatus (3), atmvccStatus (4) } ACCESS read-write STATUS mandatory DESCRIPTION "The default content of the lower configurable status window." ::= { mibuserProfileEntry 14 } userProfile-LeftStatus OBJECT-TYPE SYNTAX INTEGER { sessionList (1), connectionList (2), callstatsList (3) } ACCESS read-write STATUS mandatory DESCRIPTION "The default content of the left configurable status window." ::= { mibuserProfileEntry 15 } userProfile-ScreenWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The total width of the user's terminal window (default = 80 chars)." ::= { mibuserProfileEntry 16 } userProfile-ScreenLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The total height of the user's terminal window (default = 24 lines)." ::= { mibuserProfileEntry 17 } userProfile-StatusLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The number of lines of screen-length used by status (default = 18 lines, counting dividers)." ::= { mibuserProfileEntry 18 } userProfile-UseScrollRegions OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "If TRUE, VT100 scroll region commands will be used to reduce screen redraws when the status screen is being displayed." ::= { mibuserProfileEntry 19 } userProfile-LogDisplayLevel OBJECT-TYPE SYNTAX INTEGER { none (1), emergency (2), alert (3), critical (4), error (5), warning (6), notice (7), info (8), debug (9) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the level of log message to display immediately to the user." ::= { mibuserProfileEntry 20 } userProfile-Action-o OBJECT-TYPE SYNTAX INTEGER { noAction (1), createProfile (2), deleteProfile (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibuserProfileEntry 21 } END