-- Ascend mibswannet MIB -- -- Ascend Communications, Inc -- 1275 Harbor Bay Pkwy -- Alameda, CA 94502 -- +1 510 769 6001 -- info@ascend.com -- -- Copyright (c) 1993-1999 Ascend Communications, Inc. -- All rights reserved. -- -- Do not edit this file directly. -- It is generated automatically by mibgen for use with -- TAOS version 10.0.1 or newer. -- ASCEND-MIBSWANNET-MIB DEFINITIONS ::= BEGIN IMPORTS configuration FROM ASCEND-MIB IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- If any of the MIB compilers have problems with the DisplayString -- or PhysAddress, uncomment the next two lines. DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING mibswanNetworkProfile OBJECT IDENTIFIER ::= { configuration 124} -- The mibswanNetworkProfile table -- -- This table contains parameters for the mibswanNetworkProfile profile -- mibswanNetworkProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF MibswanNetworkProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of mibswanNetworkProfile profile entries." ::= { mibswanNetworkProfile 1 } mibswanNetworkProfileEntry OBJECT-TYPE SYNTAX MibswanNetworkProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A mibswanNetworkProfile entry containing objects that maps to the parameters of mibswanNetworkProfile profile." INDEX { swanNetworkProfile-Shelf-o, swanNetworkProfile-Slot-o, swanNetworkProfile-Item-o } ::= { mibswanNetworkProfileTable 1 } MibswanNetworkProfileEntry ::= SEQUENCE { swanNetworkProfile-Shelf-o INTEGER, swanNetworkProfile-Slot-o INTEGER, swanNetworkProfile-Item-o INTEGER, swanNetworkProfile-Name DisplayString, swanNetworkProfile-PhysicalAddress-Shelf INTEGER, swanNetworkProfile-PhysicalAddress-Slot INTEGER, swanNetworkProfile-PhysicalAddress-ItemNumber INTEGER, swanNetworkProfile-Enabled INTEGER, swanNetworkProfile-LineConfig-TrunkGroup INTEGER, swanNetworkProfile-LineConfig-NailedGroup INTEGER, swanNetworkProfile-LineConfig-RoutePort-SlotNumber-SlotNumber INTEGER, swanNetworkProfile-LineConfig-RoutePort-SlotNumber-ShelfNumber INTEGER, swanNetworkProfile-LineConfig-RoutePort-RelativePortNumber-RelativePortNumber INTEGER, swanNetworkProfile-LineConfig-Activation INTEGER, swanNetworkProfile-LineConfig-Clocking-ClockMode INTEGER, swanNetworkProfile-LineConfig-Clocking-Divider INTEGER, swanNetworkProfile-LineConfig-Clocking-Exp INTEGER, swanNetworkProfile-LineConfig-Clocking-LineRate INTEGER, swanNetworkProfile-Action-o INTEGER } swanNetworkProfile-Shelf-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibswanNetworkProfileEntry 1 } swanNetworkProfile-Slot-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibswanNetworkProfileEntry 2 } swanNetworkProfile-Item-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibswanNetworkProfileEntry 3 } swanNetworkProfile-Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Swan line for display purposes." ::= { mibswanNetworkProfileEntry 4 } swanNetworkProfile-PhysicalAddress-Shelf OBJECT-TYPE SYNTAX INTEGER { anyShelf (1), shelf1 (2), shelf2 (3), shelf3 (4), shelf4 (5), shelf5 (6), shelf6 (7), shelf7 (8), shelf8 (9), shelf9 (10) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the shelf that the addressed physical device resides on." ::= { mibswanNetworkProfileEntry 5 } swanNetworkProfile-PhysicalAddress-Slot OBJECT-TYPE SYNTAX INTEGER { anySlot (1), slot1 (2), slot2 (3), slot3 (4), slot4 (5), slot5 (6), slot6 (7), slot7 (8), slot8 (9), slot9 (10), slot10 (11), slot11 (12), slot12 (13), slot13 (14), slot14 (15), slot15 (16), slot16 (17), slot17 (18), slot18 (19), slot19 (20), slot20 (21), slot21 (22), slot22 (23), slot23 (24), slot24 (25), slot25 (26), slot26 (27), slot27 (28), slot28 (29), slot29 (30), slot30 (31), slot31 (32), slot32 (33), slot33 (34), slot34 (35), slot35 (36), slot36 (37), slot37 (38), slot38 (39), slot39 (40), slot40 (41), aLim (55), bLim (56), cLim (57), dLim (58), leftController (49), rightController (50), controller (42), firstControlModule (53), secondControlModule (54), trunkModule1 (45), trunkModule2 (46), controlModule (51), slotPrimary (59) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the slot that the addressed physical device resides on." ::= { mibswanNetworkProfileEntry 6 } swanNetworkProfile-PhysicalAddress-ItemNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that specifies an addressable entity within the context of shelf and slot." ::= { mibswanNetworkProfileEntry 7 } swanNetworkProfile-Enabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if the line is enabled, otherwise FALSE." ::= { mibswanNetworkProfileEntry 8 } swanNetworkProfile-LineConfig-TrunkGroup OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The trunk group to which this line is assigned. 0 means this line is not part of a trunk group." ::= { mibswanNetworkProfileEntry 9 } swanNetworkProfile-LineConfig-NailedGroup OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that identifies the set of lines that makes up a nailed group." ::= { mibswanNetworkProfileEntry 10 } swanNetworkProfile-LineConfig-RoutePort-SlotNumber-SlotNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibswanNetworkProfileEntry 11 } swanNetworkProfile-LineConfig-RoutePort-SlotNumber-ShelfNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "TNT is a multi shelf system. To minimise the changes required to existing code the shelf number is added to this structure as it will almost always be needed when a slot number is needed." ::= { mibswanNetworkProfileEntry 12 } swanNetworkProfile-LineConfig-RoutePort-RelativePortNumber-RelativePortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibswanNetworkProfileEntry 13 } swanNetworkProfile-LineConfig-Activation OBJECT-TYPE SYNTAX INTEGER { static (1), dsrActive (2), dcdDsrActive (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Line activation mode (port control lead usage)." ::= { mibswanNetworkProfileEntry 14 } swanNetworkProfile-LineConfig-Clocking-ClockMode OBJECT-TYPE SYNTAX INTEGER { externalClock (1), internalClock (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Line clocking mode, internal/external." ::= { mibswanNetworkProfileEntry 18 } swanNetworkProfile-LineConfig-Clocking-Divider OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The divider may be 1-256 and divides the 16.667 MHz source clock." ::= { mibswanNetworkProfileEntry 19 } swanNetworkProfile-LineConfig-Clocking-Exp OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The exp may be 0-9, the internal clock is further modified by dividing by 2 raised to the 'exp' power." ::= { mibswanNetworkProfileEntry 20 } swanNetworkProfile-LineConfig-Clocking-LineRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Line rate in bit-per-second." ::= { mibswanNetworkProfileEntry 21 } swanNetworkProfile-Action-o OBJECT-TYPE SYNTAX INTEGER { noAction (1), createProfile (2), deleteProfile (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibswanNetworkProfileEntry 22 } END