-- Ascend mibstmnet MIB -- -- Ascend Communications, Inc -- 1275 Harbor Bay Pkwy -- Alameda, CA 94502 -- +1 510 769 6001 -- info@ascend.com -- -- Copyright (c) 1993-1999 Ascend Communications, Inc. -- All rights reserved. -- -- Do not edit this file directly. -- It is generated automatically by mibgen for use with -- TAOS version 10.0.1 or newer. -- ASCEND-MIBSTMNET-MIB DEFINITIONS ::= BEGIN IMPORTS configuration FROM ASCEND-MIB IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- If any of the MIB compilers have problems with the DisplayString -- or PhysAddress, uncomment the next two lines. DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING mibsTMNetworkProfile OBJECT IDENTIFIER ::= { configuration 123} -- The mibsTMNetworkProfile table -- -- This table contains parameters for the mibsTMNetworkProfile profile -- mibsTMNetworkProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF MibsTMNetworkProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of mibsTMNetworkProfile profile entries." ::= { mibsTMNetworkProfile 1 } mibsTMNetworkProfileEntry OBJECT-TYPE SYNTAX MibsTMNetworkProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A mibsTMNetworkProfile entry containing objects that maps to the parameters of mibsTMNetworkProfile profile." INDEX { sTMNetworkProfile-Shelf-o, sTMNetworkProfile-Slot-o, sTMNetworkProfile-Item-o } ::= { mibsTMNetworkProfileTable 1 } MibsTMNetworkProfileEntry ::= SEQUENCE { sTMNetworkProfile-Shelf-o INTEGER, sTMNetworkProfile-Slot-o INTEGER, sTMNetworkProfile-Item-o INTEGER, sTMNetworkProfile-Name DisplayString, sTMNetworkProfile-PhysicalAddress-Shelf INTEGER, sTMNetworkProfile-PhysicalAddress-Slot INTEGER, sTMNetworkProfile-PhysicalAddress-ItemNumber INTEGER, sTMNetworkProfile-Enabled INTEGER, sTMNetworkProfile-AuPointer INTEGER, sTMNetworkProfile-Signaling INTEGER, sTMNetworkProfile-LoopTiming INTEGER, sTMNetworkProfile-Loopback INTEGER, sTMNetworkProfile-ApsConfigName DisplayString, sTMNetworkProfile-Action-o INTEGER } sTMNetworkProfile-Shelf-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibsTMNetworkProfileEntry 1 } sTMNetworkProfile-Slot-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibsTMNetworkProfileEntry 2 } sTMNetworkProfile-Item-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibsTMNetworkProfileEntry 3 } sTMNetworkProfile-Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Name of STM network line." ::= { mibsTMNetworkProfileEntry 4 } sTMNetworkProfile-PhysicalAddress-Shelf OBJECT-TYPE SYNTAX INTEGER { anyShelf (1), shelf1 (2), shelf2 (3), shelf3 (4), shelf4 (5), shelf5 (6), shelf6 (7), shelf7 (8), shelf8 (9), shelf9 (10) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the shelf that the addressed physical device resides on." ::= { mibsTMNetworkProfileEntry 5 } sTMNetworkProfile-PhysicalAddress-Slot OBJECT-TYPE SYNTAX INTEGER { anySlot (1), slot1 (2), slot2 (3), slot3 (4), slot4 (5), slot5 (6), slot6 (7), slot7 (8), slot8 (9), slot9 (10), slot10 (11), slot11 (12), slot12 (13), slot13 (14), slot14 (15), slot15 (16), slot16 (17), slot17 (18), slot18 (19), slot19 (20), slot20 (21), slot21 (22), slot22 (23), slot23 (24), slot24 (25), slot25 (26), slot26 (27), slot27 (28), slot28 (29), slot29 (30), slot30 (31), slot31 (32), slot32 (33), slot33 (34), slot34 (35), slot35 (36), slot36 (37), slot37 (38), slot38 (39), slot39 (40), slot40 (41), aLim (55), bLim (56), cLim (57), dLim (58), leftController (49), rightController (50), controller (42), firstControlModule (53), secondControlModule (54), trunkModule1 (45), trunkModule2 (46), controlModule (51), slotPrimary (59) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the slot that the addressed physical device resides on." ::= { mibsTMNetworkProfileEntry 6 } sTMNetworkProfile-PhysicalAddress-ItemNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that specifies an addressable entity within the context of shelf and slot." ::= { mibsTMNetworkProfileEntry 7 } sTMNetworkProfile-Enabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if the link is enabled, otherwise FALSE." ::= { mibsTMNetworkProfileEntry 10 } sTMNetworkProfile-AuPointer OBJECT-TYPE SYNTAX INTEGER { au3Pointer (2), au4Pointer (3) } ACCESS read-write STATUS mandatory DESCRIPTION "The AU pointer used by this STM-1 link." ::= { mibsTMNetworkProfileEntry 11 } sTMNetworkProfile-Signaling OBJECT-TYPE SYNTAX INTEGER { sonet (2), sdh (3), japan (4) } ACCESS read-write STATUS mandatory DESCRIPTION "The STM signaling to use on this STM link." ::= { mibsTMNetworkProfileEntry 14 } sTMNetworkProfile-LoopTiming OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if the line is to use loop timing, otherwise FALSE." ::= { mibsTMNetworkProfileEntry 8 } sTMNetworkProfile-Loopback OBJECT-TYPE SYNTAX INTEGER { noLoopback (1), lineLoopback (2), localLoopback (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Loopback mode" ::= { mibsTMNetworkProfileEntry 12 } sTMNetworkProfile-ApsConfigName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "APS Config Profile name, specifies APS configuration profile that defines a protection group for this line." ::= { mibsTMNetworkProfileEntry 13 } sTMNetworkProfile-Action-o OBJECT-TYPE SYNTAX INTEGER { noAction (1), createProfile (2), deleteProfile (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibsTMNetworkProfileEntry 9 } END