-- Ascend mibstaticslot MIB -- -- Ascend Communications, Inc -- 1275 Harbor Bay Pkwy -- Alameda, CA 94502 -- +1 510 769 6001 -- info@ascend.com -- -- Copyright (c) 1993-1999 Ascend Communications, Inc. -- All rights reserved. -- -- Do not edit this file directly. -- It is generated automatically by mibgen for use with -- TAOS version 10.0.1 or newer. -- ASCEND-MIBSTATICSLOT-MIB DEFINITIONS ::= BEGIN IMPORTS configuration FROM ASCEND-MIB IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- If any of the MIB compilers have problems with the DisplayString -- or PhysAddress, uncomment the next two lines. DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING mibmibProfSlotStatic OBJECT IDENTIFIER ::= { configuration 31} -- The mibmibProfSlotStatic table -- -- This table contains parameters for the mibmibProfSlotStatic profile -- mibmibProfSlotStaticTable OBJECT-TYPE SYNTAX SEQUENCE OF MibmibProfSlotStaticEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of mibmibProfSlotStatic profile entries." ::= { mibmibProfSlotStatic 1 } mibmibProfSlotStaticEntry OBJECT-TYPE SYNTAX MibmibProfSlotStaticEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A mibmibProfSlotStatic entry containing objects that maps to the parameters of mibmibProfSlotStatic profile." INDEX { mibProfSlotStatic-Shelf-o, mibProfSlotStatic-Slot-o, mibProfSlotStatic-Item-o } ::= { mibmibProfSlotStaticTable 1 } MibmibProfSlotStaticEntry ::= SEQUENCE { mibProfSlotStatic-Shelf-o INTEGER, mibProfSlotStatic-Slot-o INTEGER, mibProfSlotStatic-Item-o INTEGER, mibProfSlotStatic-Name DisplayString, mibProfSlotStatic-PhysicalAddress-Shelf INTEGER, mibProfSlotStatic-PhysicalAddress-Slot INTEGER, mibProfSlotStatic-PhysicalAddress-ItemNumber INTEGER, mibProfSlotStatic-AtmParameters-IncomingPriority INTEGER, mibProfSlotStatic-InterfaceType INTEGER, mibProfSlotStatic-Action-o INTEGER } mibProfSlotStatic-Shelf-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibmibProfSlotStaticEntry 1 } mibProfSlotStatic-Slot-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibmibProfSlotStaticEntry 2 } mibProfSlotStatic-Item-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibmibProfSlotStaticEntry 3 } mibProfSlotStatic-Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "For future use. The current design does not use this name attribute but instead references a LIM or CM slot by its profile index; we may in the future support referencing a LIM or CM slot by its name as well as by its physical address. This name attribute consists of a null-terminated ASCII string; is read-only; and defaults to the ASCII form of this LIM or CM slot physical address." ::= { mibmibProfSlotStaticEntry 4 } mibProfSlotStatic-PhysicalAddress-Shelf OBJECT-TYPE SYNTAX INTEGER { anyShelf (1), shelf1 (2), shelf2 (3), shelf3 (4), shelf4 (5), shelf5 (6), shelf6 (7), shelf7 (8), shelf8 (9), shelf9 (10) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the shelf that the addressed physical device resides on." ::= { mibmibProfSlotStaticEntry 5 } mibProfSlotStatic-PhysicalAddress-Slot OBJECT-TYPE SYNTAX INTEGER { anySlot (1), slot1 (2), slot2 (3), slot3 (4), slot4 (5), slot5 (6), slot6 (7), slot7 (8), slot8 (9), slot9 (10), slot10 (11), slot11 (12), slot12 (13), slot13 (14), slot14 (15), slot15 (16), slot16 (17), slot17 (18), slot18 (19), slot19 (20), slot20 (21), slot21 (22), slot22 (23), slot23 (24), slot24 (25), slot25 (26), slot26 (27), slot27 (28), slot28 (29), slot29 (30), slot30 (31), slot31 (32), slot32 (33), slot33 (34), slot34 (35), slot35 (36), slot36 (37), slot37 (38), slot38 (39), slot39 (40), slot40 (41), aLim (55), bLim (56), cLim (57), dLim (58), leftController (49), rightController (50), controller (42), firstControlModule (53), secondControlModule (54), trunkModule1 (45), trunkModule2 (46), controlModule (51), slotPrimary (59) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the slot that the addressed physical device resides on." ::= { mibmibProfSlotStaticEntry 6 } mibProfSlotStatic-PhysicalAddress-ItemNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that specifies an addressable entity within the context of shelf and slot." ::= { mibmibProfSlotStaticEntry 7 } mibProfSlotStatic-AtmParameters-IncomingPriority OBJECT-TYPE SYNTAX INTEGER { lowPriority (1), highPriority (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the relative priority of ATM cells incoming from this LIM or CM slot. A slot's incoming-priority is used to select the appropriate outgoing queue that is associated with the outgoing port from the internal ATM cell processing engine. All ports on this slot and all ATM service categories share the same incoming-priority. An outgoing port (from the internal ATM cell processing engine) can have multiple queues associated with a given QoS. The incoming-priority is used to select which queue to use among all the queues associated with the given QoS." ::= { mibmibProfSlotStaticEntry 8 } mibProfSlotStatic-InterfaceType OBJECT-TYPE SYNTAX INTEGER { default (1), gShdsl (2), hdsl2 (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Modifying this field does not effect non-hdsl/shdsl cards. All slots are set to 'default' at initialization. g.shdsl is used as 'default' for slots with hdsl2/g.shdsl cards. non-hdsl/shdsl slots default into their card types. The HDSL2 and SHDSL slot cards support HDSL2 or G.SHDSL modem technologies." ::= { mibmibProfSlotStaticEntry 10 } mibProfSlotStatic-Action-o OBJECT-TYPE SYNTAX INTEGER { noAction (1), createProfile (2), deleteProfile (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibmibProfSlotStaticEntry 9 } END