-- Ascend mibshdslnet MIB -- -- Ascend Communications, Inc -- 1275 Harbor Bay Pkwy -- Alameda, CA 94502 -- +1 510 769 6001 -- info@ascend.com -- -- Copyright (c) 1993-1999 Ascend Communications, Inc. -- All rights reserved. -- -- Do not edit this file directly. -- It is generated automatically by mibgen for use with -- TAOS version 10.0.1 or newer. -- ASCEND-MIBSHDSLNET-MIB DEFINITIONS ::= BEGIN IMPORTS configuration FROM ASCEND-MIB IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- If any of the MIB compilers have problems with the DisplayString -- or PhysAddress, uncomment the next two lines. DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING mibshdslNetworkProfile OBJECT IDENTIFIER ::= { configuration 147} -- The mibshdslNetworkProfile table -- -- This table contains parameters for the mibshdslNetworkProfile profile -- mibshdslNetworkProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF MibshdslNetworkProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of mibshdslNetworkProfile profile entries." ::= { mibshdslNetworkProfile 1 } mibshdslNetworkProfileEntry OBJECT-TYPE SYNTAX MibshdslNetworkProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A mibshdslNetworkProfile entry containing objects that maps to the parameters of mibshdslNetworkProfile profile." INDEX { shdslNetworkProfile-Shelf-o, shdslNetworkProfile-Slot-o, shdslNetworkProfile-Item-o } ::= { mibshdslNetworkProfileTable 1 } MibshdslNetworkProfileEntry ::= SEQUENCE { shdslNetworkProfile-Shelf-o INTEGER, shdslNetworkProfile-Slot-o INTEGER, shdslNetworkProfile-Item-o INTEGER, shdslNetworkProfile-Name DisplayString, shdslNetworkProfile-PhysicalAddress-Shelf INTEGER, shdslNetworkProfile-PhysicalAddress-Slot INTEGER, shdslNetworkProfile-PhysicalAddress-ItemNumber INTEGER, shdslNetworkProfile-Enabled INTEGER, shdslNetworkProfile-SparingMode INTEGER, shdslNetworkProfile-IgnoreLineup INTEGER, shdslNetworkProfile-ProfileNumber INTEGER, shdslNetworkProfile-LineConfig-TrunkGroup INTEGER, shdslNetworkProfile-LineConfig-NailedGroup INTEGER, shdslNetworkProfile-LineConfig-VpSwitchingVpi INTEGER, shdslNetworkProfile-LineConfig-RoutePort-SlotNumber-SlotNumber INTEGER, shdslNetworkProfile-LineConfig-RoutePort-SlotNumber-ShelfNumber INTEGER, shdslNetworkProfile-LineConfig-RoutePort-RelativePortNumber-RelativePortNumber INTEGER, shdslNetworkProfile-LineConfig-Activation INTEGER, shdslNetworkProfile-LineConfig-CallRouteInfo-Shelf INTEGER, shdslNetworkProfile-LineConfig-CallRouteInfo-Slot INTEGER, shdslNetworkProfile-LineConfig-CallRouteInfo-ItemNumber INTEGER, shdslNetworkProfile-LineConfig-UnitType INTEGER, shdslNetworkProfile-LineConfig-NtrEnabled INTEGER, shdslNetworkProfile-LineConfig-ClockSource INTEGER, shdslNetworkProfile-LineConfig-ClockPriority INTEGER, shdslNetworkProfile-LineConfig-LoopBack INTEGER, shdslNetworkProfile-LineConfig-Margin INTEGER, shdslNetworkProfile-LineConfig-SnextMargin INTEGER, shdslNetworkProfile-LineConfig-RateMode INTEGER, shdslNetworkProfile-LineConfig-MinRate INTEGER, shdslNetworkProfile-LineConfig-MaxRate INTEGER, shdslNetworkProfile-LineConfig-GshdslStandardNetworkType INTEGER, shdslNetworkProfile-LineConfig-AnnexbAnfpEnabled INTEGER, shdslNetworkProfile-LineConfig-GshdslPsdType INTEGER, shdslNetworkProfile-LineConfig-MasterBindingPort INTEGER, shdslNetworkProfile-Action-o INTEGER } shdslNetworkProfile-Shelf-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibshdslNetworkProfileEntry 1 } shdslNetworkProfile-Slot-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibshdslNetworkProfileEntry 2 } shdslNetworkProfile-Item-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibshdslNetworkProfileEntry 3 } shdslNetworkProfile-Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "For future use. The current design does not use the name field but instead references Shdsl lines by the physical address; we may in the future support referencing Shdsl lines by name as well as by address. The name consists of a null terminated ascii string supplied by the user; it defaults to the ascii form of the Shdsl line physical address." ::= { mibshdslNetworkProfileEntry 4 } shdslNetworkProfile-PhysicalAddress-Shelf OBJECT-TYPE SYNTAX INTEGER { anyShelf (1), shelf1 (2), shelf2 (3), shelf3 (4), shelf4 (5), shelf5 (6), shelf6 (7), shelf7 (8), shelf8 (9), shelf9 (10) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the shelf that the addressed physical device resides on." ::= { mibshdslNetworkProfileEntry 5 } shdslNetworkProfile-PhysicalAddress-Slot OBJECT-TYPE SYNTAX INTEGER { anySlot (1), slot1 (2), slot2 (3), slot3 (4), slot4 (5), slot5 (6), slot6 (7), slot7 (8), slot8 (9), slot9 (10), slot10 (11), slot11 (12), slot12 (13), slot13 (14), slot14 (15), slot15 (16), slot16 (17), slot17 (18), slot18 (19), slot19 (20), slot20 (21), slot21 (22), slot22 (23), slot23 (24), slot24 (25), slot25 (26), slot26 (27), slot27 (28), slot28 (29), slot29 (30), slot30 (31), slot31 (32), slot32 (33), slot33 (34), slot34 (35), slot35 (36), slot36 (37), slot37 (38), slot38 (39), slot39 (40), slot40 (41), aLim (55), bLim (56), cLim (57), dLim (58), leftController (49), rightController (50), controller (42), firstControlModule (53), secondControlModule (54), trunkModule1 (45), trunkModule2 (46), controlModule (51), slotPrimary (59) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the slot that the addressed physical device resides on." ::= { mibshdslNetworkProfileEntry 6 } shdslNetworkProfile-PhysicalAddress-ItemNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that specifies an addressable entity within the context of shelf and slot." ::= { mibshdslNetworkProfileEntry 7 } shdslNetworkProfile-Enabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if the line is enabled, otherwise FALSE." ::= { mibshdslNetworkProfileEntry 8 } shdslNetworkProfile-SparingMode OBJECT-TYPE SYNTAX INTEGER { inactive (1), manual (2), automatic (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Port sparing operational mode for this port." ::= { mibshdslNetworkProfileEntry 9 } shdslNetworkProfile-IgnoreLineup OBJECT-TYPE SYNTAX INTEGER { systemDefined (1), no (2), yes (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Ignore line up value for this port." ::= { mibshdslNetworkProfileEntry 10 } shdslNetworkProfile-ProfileNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "For potential backwards compatibility. The current design consists of one line profile numbered 0." ::= { mibshdslNetworkProfileEntry 11 } shdslNetworkProfile-LineConfig-TrunkGroup OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The trunk group to which this line is assigned. 0 means this line is not part of a trunk group." ::= { mibshdslNetworkProfileEntry 12 } shdslNetworkProfile-LineConfig-NailedGroup OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that identifies the set of lines that makes up a nailed group. 0 means this line is not part of a nailed group." ::= { mibshdslNetworkProfileEntry 13 } shdslNetworkProfile-LineConfig-VpSwitchingVpi OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Vpi to be used for the VP switching. Rest of the valid VPIs in valid vpi-vci-range will be used for the VC switching. Changes in this range will take effect immediately. THE USER SHOULD BE VERY CAREFUL WHILE CHANGING THIS VALUE BECAUSE ALL CONNECTIONS ON THE LIM WHERE THIS PORT BELONGS WILL BE DROPPED IN ORDER TO MAKE THIS NEW VALUE EFFECTIVE IMMEDIATELY." ::= { mibshdslNetworkProfileEntry 14 } shdslNetworkProfile-LineConfig-RoutePort-SlotNumber-SlotNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibshdslNetworkProfileEntry 15 } shdslNetworkProfile-LineConfig-RoutePort-SlotNumber-ShelfNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "TNT is a multi shelf system. To minimise the changes required to existing code the shelf number is added to this structure as it will almost always be needed when a slot number is needed." ::= { mibshdslNetworkProfileEntry 16 } shdslNetworkProfile-LineConfig-RoutePort-RelativePortNumber-RelativePortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibshdslNetworkProfileEntry 17 } shdslNetworkProfile-LineConfig-Activation OBJECT-TYPE SYNTAX INTEGER { static (1), dsrActive (2), dcdDsrActive (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Line activation mode." ::= { mibshdslNetworkProfileEntry 18 } shdslNetworkProfile-LineConfig-CallRouteInfo-Shelf OBJECT-TYPE SYNTAX INTEGER { anyShelf (1), shelf1 (2), shelf2 (3), shelf3 (4), shelf4 (5), shelf5 (6), shelf6 (7), shelf7 (8), shelf8 (9), shelf9 (10) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the shelf that the addressed physical device resides on." ::= { mibshdslNetworkProfileEntry 19 } shdslNetworkProfile-LineConfig-CallRouteInfo-Slot OBJECT-TYPE SYNTAX INTEGER { anySlot (1), slot1 (2), slot2 (3), slot3 (4), slot4 (5), slot5 (6), slot6 (7), slot7 (8), slot8 (9), slot9 (10), slot10 (11), slot11 (12), slot12 (13), slot13 (14), slot14 (15), slot15 (16), slot16 (17), slot17 (18), slot18 (19), slot19 (20), slot20 (21), slot21 (22), slot22 (23), slot23 (24), slot24 (25), slot25 (26), slot26 (27), slot27 (28), slot28 (29), slot29 (30), slot30 (31), slot31 (32), slot32 (33), slot33 (34), slot34 (35), slot35 (36), slot36 (37), slot37 (38), slot38 (39), slot39 (40), slot40 (41), aLim (55), bLim (56), cLim (57), dLim (58), leftController (49), rightController (50), controller (42), firstControlModule (53), secondControlModule (54), trunkModule1 (45), trunkModule2 (46), controlModule (51), slotPrimary (59) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the slot that the addressed physical device resides on." ::= { mibshdslNetworkProfileEntry 20 } shdslNetworkProfile-LineConfig-CallRouteInfo-ItemNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that specifies an addressable entity within the context of shelf and slot." ::= { mibshdslNetworkProfileEntry 21 } shdslNetworkProfile-LineConfig-UnitType OBJECT-TYPE SYNTAX INTEGER { coe (1), cpe (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The Unit Type defines if a line is acting as either a Central Office (COE) or Customer Premise Equipment (CPE). Note that the remote unit needs to be configured opposite to this configureation." ::= { mibshdslNetworkProfileEntry 22 } shdslNetworkProfile-LineConfig-NtrEnabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if NTR functionality is enabled, otherwise FALSE. If the unit-type is COE, it will take the system clock as the input when NTR is enabled and allow the remote CPE port to recover the clock. If the unit-type is CPE, it will allow the port to possibly output the recovered clock as the system clock (if elected, see clock-source and clock-priority fields) when NTR is enabled." ::= { mibshdslNetworkProfileEntry 23 } shdslNetworkProfile-LineConfig-ClockSource OBJECT-TYPE SYNTAX INTEGER { eligible (1), notEligible (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Determine whether the 8KHz clock from the SHDSL line (unit-type has to be CPE and ntr-enabled has to be yes) is eligible to be used as the 8KHz system clock source." ::= { mibshdslNetworkProfileEntry 24 } shdslNetworkProfile-LineConfig-ClockPriority OBJECT-TYPE SYNTAX INTEGER { highPriority (2), middlePriority (3), lowPriority (4) } ACCESS read-write STATUS mandatory DESCRIPTION "Clock priority assigned to the SHDSL line. Used to select a particular SHDSL line as the 8KHz system clock source." ::= { mibshdslNetworkProfileEntry 25 } shdslNetworkProfile-LineConfig-LoopBack OBJECT-TYPE SYNTAX INTEGER { none (1), analog (2), digital (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Configuration of different modem loopbacks." ::= { mibshdslNetworkProfileEntry 26 } shdslNetworkProfile-LineConfig-Margin OBJECT-TYPE SYNTAX INTEGER { n-0db (1), n-1db (2), n-2db (3), n-3db (4), n-4db (5), n-5db (6), n-6db (7), n-7db (8), n-8db (9), n-9db (10), n-10db (11), disable (17) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects a margin range between the signal to noise floor." ::= { mibshdslNetworkProfileEntry 27 } shdslNetworkProfile-LineConfig-SnextMargin OBJECT-TYPE SYNTAX INTEGER { n-0db (1), n-1db (2), n-2db (3), n-3db (4), n-4db (5), n-5db (6), n-6db (7), n-7db (8), n-8db (9), n-9db (10), n-10db (11), n-plus-10db (12), n-plus-9db (13), n-plus-8db (14), n-plus-7db (15), n-plus-6db (16), n-plus-5db (17), n-plus-4db (18), n-plus-3db (19), n-plus-2db (20), n-plus-1db (21), disable (22) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects a Snext margin range with a worst-case self next noise model given current loop insertion loss." ::= { mibshdslNetworkProfileEntry 34 } shdslNetworkProfile-LineConfig-RateMode OBJECT-TYPE SYNTAX INTEGER { fixed (1), auto (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Used for G.SHDSL technology. Selects if the modem operates in Fixed or Auto rate mode." ::= { mibshdslNetworkProfileEntry 28 } shdslNetworkProfile-LineConfig-MinRate OBJECT-TYPE SYNTAX INTEGER { n-72000 (72001), n-136000 (136001), n-200000 (200001), n-264000 (264001), n-328000 (328001), n-392000 (392001), n-520000 (520001), n-776000 (776001), n-1032000 (1032001), n-1160000 (1160001), n-1288000 (1288001), n-1544000 (1544001), n-2056000 (2056001), n-2312000 (2312001) } ACCESS read-write STATUS mandatory DESCRIPTION "Used for G.SHDSL technology. When the rate-mode is set to Auto, this is the minimum rate the modem will train to." ::= { mibshdslNetworkProfileEntry 29 } shdslNetworkProfile-LineConfig-MaxRate OBJECT-TYPE SYNTAX INTEGER { n-72000 (72001), n-136000 (136001), n-200000 (200001), n-264000 (264001), n-328000 (328001), n-392000 (392001), n-520000 (520001), n-776000 (776001), n-1032000 (1032001), n-1160000 (1160001), n-1288000 (1288001), n-1544000 (1544001), n-2056000 (2056001), n-2312000 (2312001) } ACCESS read-write STATUS mandatory DESCRIPTION "Used for G.SHDSL technology. When the rate-mode is set to Auto, this is the maximum rate the modem will train to. When the rate-mode is set to Fixed, this is the only rate the mode trains to." ::= { mibshdslNetworkProfileEntry 30 } shdslNetworkProfile-LineConfig-GshdslStandardNetworkType OBJECT-TYPE SYNTAX INTEGER { northAmericanAnnexA (1), europeanAnnexB (2), autoDetect (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Per the G.SHDSL Standard G.991.2. This parameter allows selection for the modem to operate either the North American Annex 'A' or European Annex 'B' standard network types. The setting of auto-detect is only valid for CPE to train off of COE Standard Network settings." ::= { mibshdslNetworkProfileEntry 31 } shdslNetworkProfile-LineConfig-AnnexbAnfpEnabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if Annex B ANFP functionality is enabled, otherwise FALSE. The gshdsl-standard-network-type must be set to European Annex B, and the port cannot be CPE. This field makes the modem perform in Annex B mode, but slightly differently. This is to comply with the UK ANFP requirements and pass the BTexact Technologies PSD measurement technique to meet BT approval. Only enable this field for that test specifically." ::= { mibshdslNetworkProfileEntry 35 } shdslNetworkProfile-LineConfig-GshdslPsdType OBJECT-TYPE SYNTAX INTEGER { symmetric (1), asymmetric776kPsdAnnexA (4), asymmetric1544kPsdAnnexA (5), asymmetric2056kPsdAnnexB (6), asymmetric2312kPsdAnnexB (7), autoDetect (8) } ACCESS read-write STATUS mandatory DESCRIPTION "Per the G.SHDSL Standard G.911.2. This parameter allows selection for the modem to output a symmetric PSD at all rates or asymmetric PSD's at fixed rates of 776kbps or 1544kbps, for Annex A networks. Annex B networks support fixed rates of 2056kbps or 2304kbps. The setting of auto-detect is only valid for CPE to train off of COE PSD settings." ::= { mibshdslNetworkProfileEntry 32 } shdslNetworkProfile-LineConfig-MasterBindingPort OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter defines if a port is used as a master or slave for port binding purposes. Only odd ports are configured masters for the binding feature. When the master is enabled, the master port will be bound with the next even port number. Binding two SHDSL ports together will aggregate their bandwidths together. This does not apply to HDSL2 modem technology. Other line configuration rules: 1) Port rate mode needs to be Fixed. 2) The master ports max-rate and rate-mode are used for both ports. 3) Both ports need to be enabled." ::= { mibshdslNetworkProfileEntry 36 } shdslNetworkProfile-Action-o OBJECT-TYPE SYNTAX INTEGER { noAction (1), createProfile (2), deleteProfile (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibshdslNetworkProfileEntry 33 } END