-- Ascend miblinediag MIB -- -- Ascend Communications, Inc -- 1275 Harbor Bay Pkwy -- Alameda, CA 94502 -- +1 510 769 6001 -- info@ascend.com -- -- Copyright (c) 1993-1999 Ascend Communications, Inc. -- All rights reserved. -- -- Do not edit this file directly. -- It is generated automatically by mibgen for use with -- TAOS version 10.0.1 or newer. -- ASCEND-MIBLINEDIAG-MIB DEFINITIONS ::= BEGIN IMPORTS configuration FROM ASCEND-MIB IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- If any of the MIB compilers have problems with the DisplayString -- or PhysAddress, uncomment the next two lines. DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING mibmibProfLineDiag OBJECT IDENTIFIER ::= { configuration 145} -- The mibmibProfLineDiag table -- -- This table contains parameters for the mibmibProfLineDiag profile -- mibmibProfLineDiagTable OBJECT-TYPE SYNTAX SEQUENCE OF MibmibProfLineDiagEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of mibmibProfLineDiag profile entries." ::= { mibmibProfLineDiag 1 } mibmibProfLineDiagEntry OBJECT-TYPE SYNTAX MibmibProfLineDiagEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A mibmibProfLineDiag entry containing objects that maps to the parameters of mibmibProfLineDiag profile." INDEX { mibProfLineDiag-Shelf-o, mibProfLineDiag-Slot-o, mibProfLineDiag-Item-o } ::= { mibmibProfLineDiagTable 1 } MibmibProfLineDiagEntry ::= SEQUENCE { mibProfLineDiag-Shelf-o INTEGER, mibProfLineDiag-Slot-o INTEGER, mibProfLineDiag-Item-o INTEGER, mibProfLineDiag-PhysicalAddress-Shelf INTEGER, mibProfLineDiag-PhysicalAddress-Slot INTEGER, mibProfLineDiag-PhysicalAddress-ItemNumber INTEGER, mibProfLineDiag-BertTimer INTEGER, mibProfLineDiag-BertEnable INTEGER, mibProfLineDiag-IdtEnable INTEGER, mibProfLineDiag-IdtNumOfMsg INTEGER, mibProfLineDiag-Action-o INTEGER } mibProfLineDiag-Shelf-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibmibProfLineDiagEntry 1 } mibProfLineDiag-Slot-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibmibProfLineDiagEntry 2 } mibProfLineDiag-Item-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibmibProfLineDiagEntry 3 } mibProfLineDiag-PhysicalAddress-Shelf OBJECT-TYPE SYNTAX INTEGER { anyShelf (1), shelf1 (2), shelf2 (3), shelf3 (4), shelf4 (5), shelf5 (6), shelf6 (7), shelf7 (8), shelf8 (9), shelf9 (10) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the shelf that the addressed physical device resides on." ::= { mibmibProfLineDiagEntry 4 } mibProfLineDiag-PhysicalAddress-Slot OBJECT-TYPE SYNTAX INTEGER { anySlot (1), slot1 (2), slot2 (3), slot3 (4), slot4 (5), slot5 (6), slot6 (7), slot7 (8), slot8 (9), slot9 (10), slot10 (11), slot11 (12), slot12 (13), slot13 (14), slot14 (15), slot15 (16), slot16 (17), slot17 (18), slot18 (19), slot19 (20), slot20 (21), slot21 (22), slot22 (23), slot23 (24), slot24 (25), slot25 (26), slot26 (27), slot27 (28), slot28 (29), slot29 (30), slot30 (31), slot31 (32), slot32 (33), slot33 (34), slot34 (35), slot35 (36), slot36 (37), slot37 (38), slot38 (39), slot39 (40), slot40 (41), aLim (55), bLim (56), cLim (57), dLim (58), leftController (49), rightController (50), controller (42), firstControlModule (53), secondControlModule (54), trunkModule1 (45), trunkModule2 (46), controlModule (51), slotPrimary (59) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the slot that the addressed physical device resides on." ::= { mibmibProfLineDiagEntry 5 } mibProfLineDiag-PhysicalAddress-ItemNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that specifies an addressable entity within the context of shelf and slot." ::= { mibmibProfLineDiagEntry 6 } mibProfLineDiag-BertTimer OBJECT-TYPE SYNTAX INTEGER { n-1Minute (60001), n-2Minutes (120001), n-3Minutes (180001), n-4Minutes (240001), n-5Minutes (300001), n-10Minutes (600001), n-15Minutes (900001), n-20Minutes (1200001), n-30Minutes (1800001) } ACCESS read-write STATUS mandatory DESCRIPTION "When this time period expires the BER Test is stopped." ::= { mibmibProfLineDiagEntry 7 } mibProfLineDiag-BertEnable OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "To enable the BER test set this parameter to yes." ::= { mibmibProfLineDiagEntry 8 } mibProfLineDiag-IdtEnable OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "To enable the IDT test set this parameter to yes." ::= { mibmibProfLineDiagEntry 9 } mibProfLineDiag-IdtNumOfMsg OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of Messages to be sent for the IDT test." ::= { mibmibProfLineDiagEntry 10 } mibProfLineDiag-Action-o OBJECT-TYPE SYNTAX INTEGER { noAction (1), createProfile (2), deleteProfile (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibmibProfLineDiagEntry 11 } END