-- Ascend mibcadslnet MIB -- -- Ascend Communications, Inc -- 1275 Harbor Bay Pkwy -- Alameda, CA 94502 -- +1 510 769 6001 -- info@ascend.com -- -- Copyright (c) 1993-1999 Ascend Communications, Inc. -- All rights reserved. -- -- Do not edit this file directly. -- It is generated automatically by mibgen for use with -- TAOS version 10.0.1 or newer. -- ASCEND-MIBCADSLNET-MIB DEFINITIONS ::= BEGIN IMPORTS configuration FROM ASCEND-MIB IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- If any of the MIB compilers have problems with the DisplayString -- or PhysAddress, uncomment the next two lines. DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING mibcadslNetworkProfile OBJECT IDENTIFIER ::= { configuration 6} -- The mibcadslNetworkProfile table -- -- This table contains parameters for the mibcadslNetworkProfile profile -- mibcadslNetworkProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF MibcadslNetworkProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of mibcadslNetworkProfile profile entries." ::= { mibcadslNetworkProfile 1 } mibcadslNetworkProfileEntry OBJECT-TYPE SYNTAX MibcadslNetworkProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A mibcadslNetworkProfile entry containing objects that maps to the parameters of mibcadslNetworkProfile profile." INDEX { cadslNetworkProfile-Shelf-o, cadslNetworkProfile-Slot-o, cadslNetworkProfile-Item-o } ::= { mibcadslNetworkProfileTable 1 } MibcadslNetworkProfileEntry ::= SEQUENCE { cadslNetworkProfile-Shelf-o INTEGER, cadslNetworkProfile-Slot-o INTEGER, cadslNetworkProfile-Item-o INTEGER, cadslNetworkProfile-Name DisplayString, cadslNetworkProfile-PhysicalAddress-Shelf INTEGER, cadslNetworkProfile-PhysicalAddress-Slot INTEGER, cadslNetworkProfile-PhysicalAddress-ItemNumber INTEGER, cadslNetworkProfile-Enabled INTEGER, cadslNetworkProfile-ProfileNumber INTEGER, cadslNetworkProfile-LineConfig-TrunkGroup INTEGER, cadslNetworkProfile-LineConfig-NailedGroup INTEGER, cadslNetworkProfile-LineConfig-RoutePort-SlotNumber-SlotNumber INTEGER, cadslNetworkProfile-LineConfig-RoutePort-SlotNumber-ShelfNumber INTEGER, cadslNetworkProfile-LineConfig-RoutePort-RelativePortNumber-RelativePortNumber INTEGER, cadslNetworkProfile-LineConfig-Activation INTEGER, cadslNetworkProfile-LineConfig-DataRateMode INTEGER, cadslNetworkProfile-LineConfig-MaxUpStreamRate INTEGER, cadslNetworkProfile-LineConfig-MaxDownStreamRate INTEGER, cadslNetworkProfile-LineConfig-LoopBack INTEGER, cadslNetworkProfile-Action-o INTEGER } cadslNetworkProfile-Shelf-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibcadslNetworkProfileEntry 1 } cadslNetworkProfile-Slot-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibcadslNetworkProfileEntry 2 } cadslNetworkProfile-Item-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibcadslNetworkProfileEntry 3 } cadslNetworkProfile-Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "For future use. The current design does not use the name field but instead references Cap adsl lines by the physical address; we may in the future support referencing Cap adsl lines by name as well as by address. The name consists of a null terminated ascii string supplied by the user; it defaults to the ascii form of the Cap adsl line physical address." ::= { mibcadslNetworkProfileEntry 4 } cadslNetworkProfile-PhysicalAddress-Shelf OBJECT-TYPE SYNTAX INTEGER { anyShelf (1), shelf1 (2), shelf2 (3), shelf3 (4), shelf4 (5), shelf5 (6), shelf6 (7), shelf7 (8), shelf8 (9), shelf9 (10) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the shelf that the addressed physical device resides on." ::= { mibcadslNetworkProfileEntry 5 } cadslNetworkProfile-PhysicalAddress-Slot OBJECT-TYPE SYNTAX INTEGER { anySlot (1), slot1 (2), slot2 (3), slot3 (4), slot4 (5), slot5 (6), slot6 (7), slot7 (8), slot8 (9), slot9 (10), slot10 (11), slot11 (12), slot12 (13), slot13 (14), slot14 (15), slot15 (16), slot16 (17), slot17 (18), slot18 (19), slot19 (20), slot20 (21), slot21 (22), slot22 (23), slot23 (24), slot24 (25), slot25 (26), slot26 (27), slot27 (28), slot28 (29), slot29 (30), slot30 (31), slot31 (32), slot32 (33), slot33 (34), slot34 (35), slot35 (36), slot36 (37), slot37 (38), slot38 (39), slot39 (40), slot40 (41), aLim (55), bLim (56), cLim (57), dLim (58), leftController (49), rightController (50), controller (42), firstControlModule (53), secondControlModule (54), trunkModule1 (45), trunkModule2 (46), controlModule (51), slotPrimary (59) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the slot that the addressed physical device resides on." ::= { mibcadslNetworkProfileEntry 6 } cadslNetworkProfile-PhysicalAddress-ItemNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that specifies an addressable entity within the context of shelf and slot." ::= { mibcadslNetworkProfileEntry 7 } cadslNetworkProfile-Enabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if the line is enabled, otherwise FALSE." ::= { mibcadslNetworkProfileEntry 8 } cadslNetworkProfile-ProfileNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "For potential backwards compatibility. The current design consists of one line profile numbered 0." ::= { mibcadslNetworkProfileEntry 9 } cadslNetworkProfile-LineConfig-TrunkGroup OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The trunk group to which this line is assigned. 0 means this line is not part of a trunk group." ::= { mibcadslNetworkProfileEntry 10 } cadslNetworkProfile-LineConfig-NailedGroup OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that identifies the set of lines that makes up a nailed group. 0 means this line is not part of a nailed group." ::= { mibcadslNetworkProfileEntry 11 } cadslNetworkProfile-LineConfig-RoutePort-SlotNumber-SlotNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibcadslNetworkProfileEntry 12 } cadslNetworkProfile-LineConfig-RoutePort-SlotNumber-ShelfNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "TNT is a multi shelf system. To minimise the changes required to existing code the shelf number is added to this structure as it will almost always be needed when a slot number is needed." ::= { mibcadslNetworkProfileEntry 13 } cadslNetworkProfile-LineConfig-RoutePort-RelativePortNumber-RelativePortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibcadslNetworkProfileEntry 14 } cadslNetworkProfile-LineConfig-Activation OBJECT-TYPE SYNTAX INTEGER { static (1), dsrActive (2), dcdDsrActive (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Line activation mode." ::= { mibcadslNetworkProfileEntry 15 } cadslNetworkProfile-LineConfig-DataRateMode OBJECT-TYPE SYNTAX INTEGER { autobaud (2), singlebaud (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The data rate mode define the mode for modem training" ::= { mibcadslNetworkProfileEntry 19 } cadslNetworkProfile-LineConfig-MaxUpStreamRate OBJECT-TYPE SYNTAX INTEGER { n-1088000 (51), n-952000 (52), n-816000 (53), n-680000 (54), n-544000 (55), n-408000 (56), n-272000 (57) } ACCESS read-write STATUS mandatory DESCRIPTION "The up stream max rate defines the maximum rate from the coe to the cpe." ::= { mibcadslNetworkProfileEntry 20 } cadslNetworkProfile-LineConfig-MaxDownStreamRate OBJECT-TYPE SYNTAX INTEGER { n-7168000 (1), n-6272000 (2), n-5120000 (3), n-4480000 (4), n-3200000 (5), n-2688000 (6), n-2560000 (7), n-2240000 (8), n-1920000 (9), n-1600000 (10), n-1280000 (11), n-960000 (12), n-640000 (13) } ACCESS read-write STATUS mandatory DESCRIPTION "The down stream max rate defines the maximum rate from the coe to the cpe." ::= { mibcadslNetworkProfileEntry 21 } cadslNetworkProfile-LineConfig-LoopBack OBJECT-TYPE SYNTAX INTEGER { none (1), analog (2), digital (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Configuration of different modem loopbacks." ::= { mibcadslNetworkProfileEntry 23 } cadslNetworkProfile-Action-o OBJECT-TYPE SYNTAX INTEGER { noAction (1), createProfile (2), deleteProfile (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibcadslNetworkProfileEntry 22 } END