-- Ascend mibalarm MIB -- -- Ascend Communications, Inc -- 1275 Harbor Bay Pkwy -- Alameda, CA 94502 -- +1 510 769 6001 -- info@ascend.com -- -- Copyright (c) 1993-1999 Ascend Communications, Inc. -- All rights reserved. -- -- Do not edit this file directly. -- It is generated automatically by mibgen for use with -- TAOS version 10.0.1 or newer. -- ASCEND-MIBALARM-MIB DEFINITIONS ::= BEGIN IMPORTS configuration FROM ASCEND-MIB IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- If any of the MIB compilers have problems with the DisplayString -- or PhysAddress, uncomment the next two lines. DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING mibalarmProfile OBJECT IDENTIFIER ::= { configuration 33} -- The mibalarmProfile table -- -- This table contains parameters for the mibalarmProfile profile -- mibalarmProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF MibalarmProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of mibalarmProfile profile entries." ::= { mibalarmProfile 1 } mibalarmProfileEntry OBJECT-TYPE SYNTAX MibalarmProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A mibalarmProfile entry containing objects that maps to the parameters of mibalarmProfile profile." INDEX { alarmProfile-Name } ::= { mibalarmProfileTable 1 } MibalarmProfileEntry ::= SEQUENCE { alarmProfile-Name DisplayString, alarmProfile-Enabled INTEGER, alarmProfile-Event INTEGER, alarmProfile-PhysicalAddress-Shelf INTEGER, alarmProfile-PhysicalAddress-Slot INTEGER, alarmProfile-PhysicalAddress-ItemNumber INTEGER, alarmProfile-Action-AlarmLedMinor INTEGER, alarmProfile-Action-AlarmLedMajor INTEGER, alarmProfile-Action-AlarmRelayMinor INTEGER, alarmProfile-Action-AlarmRelayMinorDuration INTEGER, alarmProfile-Action-AlarmRelayMajor INTEGER, alarmProfile-Action-AlarmRelayMajorDuration INTEGER, alarmProfile-Action-o INTEGER } alarmProfile-Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The name consists of a null terminated ascii string supplied by the user" ::= { mibalarmProfileEntry 1 } alarmProfile-Enabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if the alarm profile is enabled, otherwise FALSE." ::= { mibalarmProfileEntry 2 } alarmProfile-Event OBJECT-TYPE SYNTAX INTEGER { lineStateChange (1), slotStateChange (2), primarySwitchover (3), powerFailure (4), fanFailure (5), secondaryControllerStateChange (6), inputRelayClosed (7), inputRelayOpen (8), lowTemperatureTrigger (9), highTemperatureTrigger (10), dpramCbusFailure (11) } ACCESS read-write STATUS mandatory DESCRIPTION "Alarm event type" ::= { mibalarmProfileEntry 3 } alarmProfile-PhysicalAddress-Shelf OBJECT-TYPE SYNTAX INTEGER { anyShelf (1), shelf1 (2), shelf2 (3), shelf3 (4), shelf4 (5), shelf5 (6), shelf6 (7), shelf7 (8), shelf8 (9), shelf9 (10) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the shelf that the addressed physical device resides on." ::= { mibalarmProfileEntry 4 } alarmProfile-PhysicalAddress-Slot OBJECT-TYPE SYNTAX INTEGER { anySlot (1), slot1 (2), slot2 (3), slot3 (4), slot4 (5), slot5 (6), slot6 (7), slot7 (8), slot8 (9), slot9 (10), slot10 (11), slot11 (12), slot12 (13), slot13 (14), slot14 (15), slot15 (16), slot16 (17), slot17 (18), slot18 (19), slot19 (20), slot20 (21), slot21 (22), slot22 (23), slot23 (24), slot24 (25), slot25 (26), slot26 (27), slot27 (28), slot28 (29), slot29 (30), slot30 (31), slot31 (32), slot32 (33), slot33 (34), slot34 (35), slot35 (36), slot36 (37), slot37 (38), slot38 (39), slot39 (40), slot40 (41), aLim (55), bLim (56), cLim (57), dLim (58), leftController (49), rightController (50), controller (42), firstControlModule (53), secondControlModule (54), trunkModule1 (45), trunkModule2 (46), controlModule (51), slotPrimary (59) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the slot that the addressed physical device resides on." ::= { mibalarmProfileEntry 5 } alarmProfile-PhysicalAddress-ItemNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that specifies an addressable entity within the context of shelf and slot." ::= { mibalarmProfileEntry 6 } alarmProfile-Action-AlarmLedMinor OBJECT-TYPE SYNTAX INTEGER { off (1), on (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The LED that indicates a minor alarm" ::= { mibalarmProfileEntry 7 } alarmProfile-Action-AlarmLedMajor OBJECT-TYPE SYNTAX INTEGER { off (1), on (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The LED that indicates a major alarm" ::= { mibalarmProfileEntry 8 } alarmProfile-Action-AlarmRelayMinor OBJECT-TYPE SYNTAX INTEGER { off (1), on (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The relay that is set for a minor alarm" ::= { mibalarmProfileEntry 9 } alarmProfile-Action-AlarmRelayMinorDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The duration in seconds for which the minor relay is set" ::= { mibalarmProfileEntry 10 } alarmProfile-Action-AlarmRelayMajor OBJECT-TYPE SYNTAX INTEGER { off (1), on (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The relay that is set for a major alarm" ::= { mibalarmProfileEntry 11 } alarmProfile-Action-AlarmRelayMajorDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The duration in seconds for which the major relay is set" ::= { mibalarmProfileEntry 12 } alarmProfile-Action-o OBJECT-TYPE SYNTAX INTEGER { noAction (1), createProfile (2), deleteProfile (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibalarmProfileEntry 13 } END