AISLC1-MIB DEFINITIONS ::= BEGIN -- Applied Innovation Series 1 Protocol Termination MIB definitions -- @(#) ai $Revision: 1.11 $ $Date: 15 Jan 1999 12:08:58 $ IMPORTS DisplayString FROM RFC1213-MIB MODULE-IDENTITY, OBJECT-TYPE, Counter32, Gauge32, enterprises FROM SNMPv2-SMI; -- group object IDs aii OBJECT IDENTIFIER ::= { enterprises 539 } aiSystemOID OBJECT IDENTIFIER ::= { aii 2 } aiSLC1 MODULE-IDENTITY LAST-UPDATED "980803164411Z" ORGANIZATION "Applied Innovation Incorporated" CONTACT-INFO " Engineering MIB Administrator Postal: Applied Innovation Inc. 5800 Innovation Drive Dublin, OH 43016-3271 Tel: 614/798-2000 Fax: 614/798-1770 E-mail: snmp@aiinet.com" DESCRIPTION " The MIB Module for Series One Smart Line Cards (SLC)." ::= { aii 11 } -- System group for Series One Smart Line Cards aiSLC1System OBJECT IDENTIFIER ::= { aiSLC1 1 } -- sysObjectIDs ai192 OBJECT IDENTIFIER ::= { aiSystemOID 192 } ai192Ver7 OBJECT IDENTIFIER ::= { ai192 7 } ai192Ver70 OBJECT IDENTIFIER ::= { ai192Ver7 0 } ai192Ver708 OBJECT IDENTIFIER ::= { ai192Ver70 8 } ai192Ver709 OBJECT IDENTIFIER ::= { ai192Ver70 9 } ai192Ver71 OBJECT IDENTIFIER ::= { ai192Ver7 1 } ai192Ver710 OBJECT IDENTIFIER ::= { ai192Ver71 0 } ai192Ver711 OBJECT IDENTIFIER ::= { ai192Ver71 1 } ai192Ver72 OBJECT IDENTIFIER ::= { ai192Ver7 2 } ai192Ver720 OBJECT IDENTIFIER ::= { ai192Ver72 0 } ai192Ver77 OBJECT IDENTIFIER ::= { ai192Ver7 7 } ai196 OBJECT IDENTIFIER ::= { aiSystemOID 196 } ai196Ver7 OBJECT IDENTIFIER ::= { ai196 7 } ai196Ver70 OBJECT IDENTIFIER ::= { ai196Ver7 0 } ai196Ver708 OBJECT IDENTIFIER ::= { ai196Ver70 8 } ai196Ver709 OBJECT IDENTIFIER ::= { ai196Ver70 9 } ai196Ver71 OBJECT IDENTIFIER ::= { ai196Ver7 1 } ai196Ver710 OBJECT IDENTIFIER ::= { ai196Ver71 0 } ai196Ver711 OBJECT IDENTIFIER ::= { ai196Ver71 1 } ai196Ver72 OBJECT IDENTIFIER ::= { ai196Ver7 2 } ai196Ver720 OBJECT IDENTIFIER ::= { ai196Ver72 0 } ai196Ver77 OBJECT IDENTIFIER ::= { ai196Ver7 7 } -- System Group -- Implementation of this group is mandatory for all Applied Innovation -- Series 1 Cards (SLC's) that support SNMP management aislc1AdminLogsEnabled OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines whether the SLC sends log messages to the console port of the AISwitch." DEFVAL { on } ::= { aiSLC1System 1 } aislc1AdminTrapsEnabled OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines whether the SLC sends SNMP Trap PDUs. If the active CLC in the AISwitch chassis with the SLC is not SNMP capable, this object cannot be set to the value on(1)." DEFVAL { on } ::= { aiSLC1System 2 } aislc1AdminTrapTimer OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "After a trap is generated, a timer is started. If the event that generated the trap occurs while the timer is running, no trap will be generated for the event. The value of this object is the duration of the timer in seconds." DEFVAL { 300 } ::= { aiSLC1System 3 } aislc1OperLastMsgText OBJECT-TYPE SYNTAX DisplayString (SIZE (0..245)) MAX-ACCESS read-only STATUS current DESCRIPTION "Contains the message text of the last log message that was sent by the SLC (or would have been sent, if log message transmission is disabled." ::= { aiSLC1System 4 } aislc1OperLastMsgNum OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Contains the message number of the last log message that was sent by the SLC (or would have been sent, if log message transmission is disabled." ::= { aiSLC1System 5 } aislc1OperCrashCode OBJECT-TYPE SYNTAX INTEGER{ crashbus(1), crashvector(9), crashx25(160), crashstack(162), crashmain(163), crashchecksum(164), crashinit(165), crashreboot(166), crashtimer(167), crashstopped(168), crashbadzero(169), crashmemfail(170), crashrxfifo(171), crashscc(172) } MAX-ACCESS read-only STATUS current DESCRIPTION "Contains a crash cause code. This object is for use as a varbind in TRAP PDUs only." ::= { aiSLC1System 6 } aislc1OperNumEventsSinceLastTrap OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times this trap was discarded because the aislcAdminTrapTimer had not yet expired since the last time the event which generated the trap occured. This object is for use as a varbind in TRAP PDUs only." ::= { aiSLC1System 7 } aislc1StatAIBfrsInUse OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of AI buffers currently in use." ::= { aiSLC1System 8 } aislc1StatAIBfrsTotal OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of AI buffers." ::= { aiSLC1System 9 } aislc1StatActiveVCs OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Virtual Connections currently in some state other than Idle." ::= { aiSLC1System 10 } aislc1StatTotalVCs OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of Virtual Connection structures allocated on the SLC." ::= { aiSLC1System 11 } aislc1StatMinLoopsPerSecond OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum number of iterations per second of the SLC's main polling loop during the sample period." ::= { aiSLC1System 12 } aislc1StatAvgLoopsPerSecond OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average number of iterations per second of the SLC's main polling loop during the sample period." ::= { aiSLC1System 13 } aislc1StatCurLoopsPerSecond OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of iterations of the SLC's main polling loop during the past second." ::= { aiSLC1System 14 } aislc1StatFErrFifoInIsr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of RxFIFO half-full ISR interrupts which occurred. This is not always an error, but may be indicative of a heavy load on the X.25 software." ::= { aiSLC1System 15 } aislc1StatErrFifoInFull OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of times the input FIFO was detected as full. This means that data has probably been lost, due to the inability of the X.25 software to keep pace with the RxFIFO." ::= { aiSLC1System 16 } aislc1StatErrFifoInPort OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of times a bad port number has been received through the FIFO. This is probably indicative of a hardware failure, or perhaps a software problem in the CLC code." ::= { aiSLC1System 17 } aislc1StatErrFifoInLost OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of characters received from the FIFO which were discarded because of lack of space." ::= { aiSLC1System 18 } aislc1StatErrFifoOutFull OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of times the output FIFO was detected as full. This may be an indication of a hardware fault, or a breakdown in communications between the X.25 software and CLC regarding the status of a connection(i.e., if the CLC breaks a connection while the X.25 software is still using it, a TxFIFO full will definitely result)." ::= { aiSLC1System 19 } aislc1StatErrWinInCode OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of bad transaction codes received from the CLC via the window(i.e., the transaction code is out of range of the expected values)." ::= { aiSLC1System 20 } aislc1StatErrWinInPort OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of bad port numbers received from the CLC via the window(i.e., the relative port number is out of range of the expected values)." ::= { aiSLC1System 21 } aislc1StatErrWinInConn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of bad connection transactions from the CLC via the window." ::= { aiSLC1System 22 } aislc1StatErrWinInDisc OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of bad disconnection transactions from the CLC via the window. Note that this counter will probably be incremented if calls are disconnected following a link outage, it is not necessarily indicative of a serious problem." ::= { aiSLC1System 23 } aislc1StatErrWinInAck OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of unexpected connection ACK's from the CLC via the window." ::= { aiSLC1System 24 } aislc1StatErrWinInNak OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of unexpected connection NAK's from the CLC via the window." ::= { aiSLC1System 25 } aislc1StatErrWinOutLost OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of output window transactions which were lost due to buffer failures." ::= { aiSLC1System 26 } aislc1StatAIBfrsMax OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of AI buffers that have been used." ::= { aiSLC1System 27 } END